| 1 | Item No 1 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Liftupto 1.5 m.) By Mechanical Means |
| 2 | Item No 2 :- Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim bored pile of 300 mm dia. each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by concrete prepared in reversible drum type concrete mixer by tremie arrangement, compaction of concrete including chipping and dressing etc.complete. (Excluding steel reinforcement) |
| 3 | Item No 3 :- Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. |
| 4 | Item No 4:- Providing bentonite slurry process for various diameter of piles vide Item Nos1 (i to xxiv) above. Spec : (As directed by Engineer in Charge) |
| 5 | Item No5:- Chiseling through pile shells in hard strata like boulders, soft and hard rocks Upto and inclusive of 550 mm diameter including removing and stacking the loose materials etc. complete and disposing of the unserviceablematerials outside complete. |
| 6 | Item No 6 :- Carrying out low strain pile integrity test on 300mm diameter pile including all arrangements for test, equipments/accessories, materials, labour, submission of test report etc but excluding the cost of installation of job pile (installation of pile shall be paid seperately as per releventitems)all complete as perspecification and as directed by the engineer-in-charge. |
| 7 | Item No 7:- Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 8 | Item No 8:- Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | Item No 9 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for R.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) complete (Excluding steel reinforcement) |
| 10 | Item No 10 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 11 | Item No 11 :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 12 | Item No 12 :- Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fineaggregate (Crushed sand VSI Grade) |
| 13 | Item No 13 :- Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding andsupporting as required complete. |
| 14 | item No 14:- Royalty Charges of materials |
| 15 | Item No.15 : - Testing Charges of construction Concrete : Concrete Mix Design (With all Tests on basic materials) |
| 16 | Compressive Strength OF C.C. Cube (Set of 3 cubes). |
| 17 | Crushing Value/Compressive Strength, Water Absorption &Specific Gravity, |
| 18 | Upto 16mm Dia |
| 19 | Item No 16 :- Providing and fixing 90 cm x 60 cm Marble plate engraving 10 cm. height letter,figures including painting the lefters/figures with approved colour and shade complete |
| 20 | Item No.17 - Add 1 %Labour Insurance |
| 21 | Item No. 18 - Add 18 % GST |
| 22 | Item No. 19 - Add SQM 1% Please Enable Macros to View BoQ information |