| 1 | Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 3 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. |
| 9 | With commercial grade white 15X15cm Tiles. |
| 10 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 14 | Foundations, footings, bases of columns, etc. for mass concrete |
| 15 | Suspended floors, roofs, landings, balconies and access platform |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 20 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 21 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 22 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:8) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 23 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 25 | Providing and applying plaster of paris putty of 2 mmthickness over plastered surface to prepare the surfaceeven and smooth complete. |
| 26 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 27 | Providing and applying white cement based putty ofaverage thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface toprepare the surface even and smooth complete |
| 28 | Finishing walls with textured exterior paint of requiredshade : |
| 29 | New work (Two or more coats applied @ 3.28 ltr/10sqm) over and including priming coat of exterior primerapplied @2.20kg/10 sqm. |
| 30 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 31 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 32 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 33 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 34 | Providing and fixing pressed steel door framesconforming to IS: 4351, manufactured from commercialmild steel sheet of 1.60 mm thickness, including hinges,jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of1.60 mm, pressed mild steel welded or rigidly fixedtogether by mechanical means, including M.S. pressedbutt hinges 2.5 mm thick with mortar guards, lockstrike-plate and shock absorbers as specified andapplying a coat of approved steel primer after pretreatmentof the surface |
| 35 | Fixing with carbon steel galvanised dash fastener ofrequired dia and size (to be paid for separately). |
| 36 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 37 | Providing and fixing factory made P.V.C. door frame ofsize 50x47 mm with a wall thickness of 5 mm, made outof extruded 5mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos of 150 mm long bracketsof 15x15 mm M.S. square tube, the vertical door frameprofiles to be reinforced with 19x19 mm M.S. squaretube of 19 gauge, EPDM rubber gasket weather seal tobe provided through out the frame. The door frame tobe fixed to the wall using M.S. screws of 65/100 mmsize, complete as per manufacturer’s specification anddirection of Engineer-in-Charge |
| 38 | Providing and fixing factory made panel PVC doorshutter consisting of frame made out of M.S. tubes of19 gauge thickness and size of 19 mm x 19 mm forstyles and 15x15 mm for top & bottom rails. M.S. frameshall have a coat of steel primers of approved make andmanufacture. M.S. frame covered with 5 mm thick heatmoulded PVC ‘C’ channel of size 30mm thickness, 70mm width out of which 50 mm shall be flat and 20 mmshall be tapered in 45 degree angle on both sideforming styles and 5 mm thick, 95 mm wide PVC sheetout of which 75 mm shall be flat and 20 mm shall betapered in 45 degree on the inner side to form top andbottom rail and 115 mm wide PVC sheet out of which75 mm shall be flat and 20 mm shall be tapered on bothsides to form lock rail. Top, bottom and lock rails shallbe provided both side of the panel. 10 mm (5 mm x 2 )thick, 20 mm wide cross PVC sheet be provided as gapinsert for top rail & bottom rail, paneling of 5 mm thickboth side PVC sheet to be fitted in the M.S. framewelded/ sealed to the styles & rails with 7 mm (5 mm+2mm) thick x 15 mm wide PVC sheet beading on innerside, and joined together with solvent cement adhesive.An additional 5 mm thick PVC strip of 20 mm width is tobe stuck on the interior side of the ‘C’ Channel usingPVC solvent adhesive etc. complete as per direction ofEngineer-in-charge, manufacturer’s |
| 39 | 30 mm thick pre laminated PVC door shutters |
| 40 | Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded builtup standard tubular sections/appropriate Z sections andother sections of approved make conforming to IS: 733and IS: 1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with requiredEPDM rubber/neoprene gasket etc. Aluminium sectionsshall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle,Aluminium snap beading for glazing / paneling, C.P.brass/ stainless steel screws, all complete as perarchitectural drawings and the directions of Engineerin-charge. (Glazing, paneling and dash fasteners to bepaid for separately |
| 41 | For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and makingprovision for fixing of fittings wherever requiredincluding the cost of EPDM rubber / neoprene gasketrequired (Fittings shall |
| 42 | Providing and fixing glazing in aluminium door, window,ventilator shutters and partitions etc. with EPDMrubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of engineerin-charge . (Cost of aluminium snap beading shall bepaid in basic item): |
| 43 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 44 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 45 | 10 mm dia |
| 46 | 12 mm dia |
| 47 | 16 mm dia |
| 48 | providing Tor steel reinforcement of 20mm,25mm, 28mm & 32mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 49 | 20 mm dia |
| 50 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 51 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 52 | Supplying and fixing C.I. cover without frame formanholes : |
| 53 | 500 mm diameter C.I. cover (medium duty) the weightof the cover to be not less than 58 kg. |
| 54 | Making soak pit 2.5 m diameter 3.0 metre deep with 45x 45 cm dry brick honey comb shaft with bricks andS.W. drain pipe 100 mm diameter, 1.8 m long completeas per standard design.With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 55 | Carriage of materials |
| 56 | chips |
| 57 | bricks |
| 58 | fly ash bricks |
| 59 | Point wiring in PVC conduit, with piano type switch :- Wiring for light point/fan point/exhaust fan point/call bell point, with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, piano type switch, phenolic laminated sheet with suitable size PVC/MS box etc as required |
| 60 | Group B |
| 61 | Power plug wiring in PVC conduit (2 x 4 sq. mm) :- Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required. |
| 62 | Circuit/submain wiring in PVC conduit :- Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required |
| 63 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 64 | 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire |
| 65 | 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire |
| 66 | S/F PVC/G.I. boxes :- Supplying and fixing of following sizes of PVC/G.I box on surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 67 | 72 mm x 146 mm x 48 mm deep/(4” x 7”) |
| 68 | 210 mm x 206 mm x 48 mm deep/(10” x 12”) |
| 69 | S/F light plug point with piano type accessories :- Supplying and fixing suitable size GI/PVC box of 75 mm x 75 mm x 50 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 70 | S/F power plug point with piano type accessories :- Supplying and fixing suitable size GI/PVC box of 121 mm x 173 mm x 48 mm/(6” x 8”) (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required |
| 71 | S/F ceiling rose :- Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/wood block including connection etc. as required. |
| 72 | S/F Batten holder :- Supplying and fixing Batten/Angle holder including connection etc as required. |
| 73 | ITC ceiling fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 74 | 1200 mm (48\\") Ceiling Fan |
| 75 | ITC exhaust fan upto 450 mm. sweep :- Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required |
| 76 | 9\\"(230MM) METAL EXHUST FAN |
| 77 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 78 | mv cable laying upto 35sq mm in ground |
| 79 | S/F rewireable double pole/TP&N switch disconnector :- Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc. as required. |
| 80 | 32 amps, double pole |
| 81 | S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 82 | 8 way, Single door |
| 83 | 4 way, Double door |
| 84 | S/F 'B' series, S.P. MCB :- Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 85 | 6/32 amps, single Pole, \\"B\\" series |
| 86 | S/F 'C' series, S.P. MCB :- Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, \\"C\\" curve, miniature circuit breaker suitable for lighting and motor loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Assumed continuation from 2.12) |
| 87 | 6/32 amps, Single Pole |
| 88 | 6/32 amps, SPN |
| 89 | 16/25 amps |
| 90 | P/F M.V. danger notice plate :- Providing and fixing M.V. danger notice plate of 200 mm × 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 91 | Earthing with copper earth plate 600 mm × 600 mm × 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 92 | Providing and fixing 25 mm × 5 mm copper strip on surface or in recess for connection etc. as required. |
| 93 | Supply and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. |
| 94 | Supply 15/16W LED BULB |
| 95 | 1×28watt T5 Tube light with fitting |
| 96 | Supply and installation of water tank…… |
| 97 | Supply of G.I Pipe of tata or any other……. |
| 98 | i)15 mm dia |
| 99 | ii)20 mm dia |
| 100 | iii)25 mm dia |
| 101 | iv)32 mm dia |
| 102 | v)65 mm dia |
| 103 | Earth work in excavation…….. |
| 104 | (a)for classification of oil item-B Rs,34.40/cum |
| 105 | Earth work in back filling…... |
| 106 | providing and fixing male ended 15 mm dia bras bib cock…. |
| 107 | prov. And fixing c.i stop cock of approved |
| 108 | 15 mm dia |
| 109 | Prov. And fixing G.M Full way valve…… |
| 110 | (c)25 mm dia weight not less than 1.5 kg |
| 111 | © 32 mm dia weight not less than 1.5 kg |
| 112 | (c)50 mm dia weight not less than 1.5 kg |
| 113 | cutting chajja or cornice for laying……. |
| 114 | making holes in wall for laying G.I |
| 115 | Supplying fitting and fixing the following….. |
| 116 | (b) 600×450mm mirror of 6 mm thick |
| 117 | © C.P Brass soa dise containers |
| 118 | supply material labour fo construction of 600×600×90mm stop cock member… |
| 119 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32 m C.I. brass waste 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32 mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 120 | S/F/F 40 mm high viterous white glazed earthen I.W.C. with P-trap of parry Hindustan or any other approved I.S.S. make including S/F 15 L C.I. mosquito proof low down flushing cistern .do… |
| 121 | Supplying, fitting and fixing vitreous white glazed earthen ware indian squating type 600x350mm urinal plate of parry, Hindustan or any other I.S.S. approved make with internal flushing rim, 100mm white glazed earthen ware channel about 1m. long 5 litre capacity C.I. automatic flushing cistern of reliance or any other approved make with fittings R.S. or C.I. brackets 15mm and 45 cm long PVC / Alkathene pipe standard G.I. flush pipe for backand front with spreader fittings and brass coupling etc. 15 mm C.I. Body 'brass spindle stop cock weight not less than 450 grams. all complete including painting of exposed parts with 2 coats of approved paint over a coat of red oxide primer and cutting the wall and floor and making good the same as per specification and direction of E/I. |
| 122 | (a) 600 mm x 350 mm size (large) |
| 123 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well asfule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 124 | (a) From 0.00 M to 50.00 M below G.L. |
| 125 | (b) From 51.0 M to125.00 M |
| 126 | (c) From126.0 M to150.00 M |
| 127 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 128 | 200 mm nominal size dia |
| 129 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineerin-charge |
| 130 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 131 | 200 mm dia |
| 132 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 133 | 200 mm clamp |
| 134 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages1.5 HP |
| 135 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 136 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX/ HEVELS make including all taxes, royalty etc all complete job as per direction of E/I. |
| 137 | S/F/F 40 mm Lowering 40mm dia G.L COLUMN PIPE |
| 138 | Add 18 % GST (in Basic Rate must fill 12) |
| 139 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |