| Sl. No. | Item Description |
| 1 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 15 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 2 | Removing ventilators and small windows with frame and stacking the materials with all leads lifts excetra complete.Item / Page No : 16 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 3 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 19 / 297Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 4 | Removing urinal pans or wash hand basin with frame including disconnecting the sanitary and water supply connections. removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials out side excetra complete.Item / Page No : 40 / 298Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 5 | Removing water closet pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed concrete around pan removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials out side excetra complete.carefully and throwing out the refusal outside excetra complete.Item / Page No : 41 / 298Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 6 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : Bd.E.1Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 7 | Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 24 / 215Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 8 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 27 / 215Specification No : Bd.M.13Spec. Page No : 386Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 9 | Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 milimetre thick and 75 centimetre high vertical support for Kadappa at one metre center to center of 25 milimetre thick both side polished Kadappa middle shelf and bottom of 20 milimetre thick one side polished Kadappa with facia patti of 20 milimetre X 50 milimetre Kadappa including all material, labour, cutting, fixing with cement mortar and araldite, all material labour cutting fixing with cement mortar and araldite curing polished and cleaning excetra complete. (For Ground Floor)Item / Page No : 38 / 217Specification No : Bd.M.35CSpec. Page No : 393 |
| 10 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 9 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 11 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 42 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 12 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 34 / 216Specification No : Bd.M.3 BSpec. Page No : 380Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 13 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 31 / 250Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 14 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)Item / Page No : 9 / 246Specification No : Bd.T.34Spec. Page No : 499 |
| 15 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor)Item / Page No : 44 / 254Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 16 | Providing and fixing white european type wall-hung pan, of size 350 milimetre X 355 milimetre X 570 milimetre concealed flush tank with floor mounting frame installing kit and drain pipe connection set for wall hung W.C., with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre diameter cast iron plug bend inlet pipe all fittings,cutting and making good walls, floors, excetra complete. (For Ground Floor)Item / Page No : 41 / 316Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge. |
| 17 | Providing and fixing coloured glazed earthenware wash hand basin of 55 centimetre X 40 centimetre size including cold water piller tap / cold and hot water piller tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including poly vinyl chloride waste pipe and trap upto the outside face of the wall.Making good thedamaged surface, testing excetra complete. (For Ground Floor)Item / Page No : 66 / 272Specification No : Bd.V.30Spec. Page No : 565 |
| 18 | Providing and fixing 75 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps excetra complete. (For Ground Floor)Item / Page No : 51 / 279Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 19 | Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor)Item / Page No : 52 / 279Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 20 | Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)Item / Page No : 55 / 280Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 21 | Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)Item / Page No : 57 / 280Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 22 | Providing and fixing 10 centimetre poly vinyl chloride nahani trap with grating, excetra complete. (For Ground Floor)Item / Page No : 67 / 281Specification No : Bd.V.32ASpec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 23 | Providing and fixing stainless steel sink 600 milimetre X 510 milimetre X 200 milimetre of approved make including coupling, outlet pipe, elbo and other necessary fitting, finishing excetra complete. (For Ground Floor)Item / Page No : 78 / 282Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 24 | Providing and fixing chromium plated pillar cock long neck with aerator of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)Item / Page No : 82 / 282Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 25 | Providing and fixing chromium plated bib cock with wall flange of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)Item / Page No : 83 / 283Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 26 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For Ground Floor)Item / Page No : 23 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 27 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor)Item / Page No : 26 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 28 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 29 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:5 with neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 6 / 209Specification No : Bd.L.4, Bd.L.10Spec. Page No : 368, 370Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 30 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor)Item / Page No : 68 / 259Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 31 | Providing and fixing 30 milimetre thick solid panel polyvinyl chloride internal door shutter consisting of frame made out of mild steel tubes of 19 gauge thickness and size of 40 milimetre X 20 milimetre for stiles, top, lock and bottom rails. Mild steel frame shall have a coat of steel primers of approved make and manufacture. Mild steel frame shall be covered with 5 milimetre thick heat moulded Rajshri polyvinyl chloride 'C' channel of size 30 milimetre X 100 milimetre forming stiles, and 5 milimetre thick, 125 milimetre wide poly vinyl chloride sheets for top rail, lock rail and bottom rail on either side, and 15 milimetre (5 milimetre X 3) thick, 20 milimetre wide cross poly vinyl chloride sheet as gap insert for top rail and bottom rail. Paneling of 10 milimetre thick prelam poly vinyl chloride sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with 30 milimetre wide X 5 milimetre thick poly vinyl chloride sheet beading on either side, and joined together with solvent cement adhesive, excetra An additional 5 milimetre thick poly vinyl chloride strip of 20 milimetre width is to be stuck on the interior side of the 'C' Channel using polyvinyl chloride solvent cement adhesive, including stainless steel fixtures and fastening Complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing. (For Ground Floor)Item / Page No : 81 / 261Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 32 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 33 | Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for reinforced cement concrete / cementitious surface for terrace waterproofing on burnt brick coba / reinforced cement concrete, after application of TP-42 primer on perfectly clean surface (free from loose dust and foreign matter) application of first coat of Polydee-LM at the rate of 700 grams per square metre, applying second coat of Polydee-LM at the rate of 700 grams per square metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25 milimetre cement plaster for protection with fibrillated 6 milimetre Plyplast fibre at the rate of 125 grams per square metre to be paid in separate item.) covering seven years gaurantee on court fee stamp paper of Rs. 100/- excetra complete. (For Ground Floor)Item / Page No : 10 / 206Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 34 | Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor)Item / Page No : 54 / 280Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 35 | Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for steps including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 4 / 175Specification No : Bd.E.2, B-7Spec. Page No : 288, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 36 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor)Item / Page No : 4 / 173Specification No : Bd.C.8Spec. Page No : 278 |
| 37 | Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor)Item / Page No : 34 / 236Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 38 | Providing and fixing 45 centimetre wide mild steel ladder of 40 milimetre X 6 milimetre mild steel flat stringers and steps of 18 milimetre diameter mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder with anticorossive paint complete. (For Ground Floor)Item / Page No : 56 / 271Specification No : Bd.V.19Spec. Page No : 559 |
| 39 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Compressive Strength of Cement Concrete Cube1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre |
| 40 | Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles1 Test per 2000.00 Number |
| 41 | Compressive Strength of Cement Mortar1 Test per Day |
| 42 | Thickness, Mass per Running Metre of Aluminium Section1 Test per Square Metre |
| 43 | Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks1 Test per 50000.00 Number |
| 44 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Manual MeansItem / Page No : 1 / 153Specification No : Bd.A.1Spec. Page No : 259 |
| 45 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : Bd.F.3, B-7Spec. Page No : 298, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 46 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 31 / 179Specification No : Bd.F.5, B-7Spec. Page No : 300, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 47 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 50 / 181Specification No : Bd.F.6, B-7Spec. Page No : 300-301, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 48 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306 |
| 49 | Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 milimetre to 15 milimetre thick in cement mortar 1:4 and routh cast treatment 12 milimetre thick in proportion 1:1.1/2:3 including scaffolding and fourteen days curing complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 12 / 209Specification No : Bd.L.8Spec. Page No : 370Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 50 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 1 / 264Specification No : Bd.U.1Spec. Page No : 537 |
| 51 | Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade, excetra complete. Weight 18 to 20 kilogram per Square metre. (For Ground Floor)Item / Page No : 9 / 174Specification No : Bd.W.6Spec. Page No : 585-586 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail