Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SITC of Audio Power Amplifier (Professional) |
| 2 | No. of channels : 2Sensitivity : 1.4 V at Full Rated PowerRated power output per channel : 3000W 2Ohm, 2100W 4Ohm, 1200W 8OhmSignal to noise ratio (below rated 1 kHz power at 8 Ohm) : 100-105 dB (Weighted)THD : < 0.5%Frequency response ± 1 dB IEC power connector : 20AInput supply : 230V AC ± 10V, 50 Hz IEC Power ConnectorMaximum input signal + 22 dBuInput impedience : 20KOhm balanaced, 10K Ohm unbalancedOutput Impedance Low Channle Crosstalk : > 70 dBGain 35-40 dB (Aprox) |
| 3 | SITC of Audio Mixer Digital with control interface touch screen (Professional) |
| 4 | Audio mixer type : Analog Mixer, Control Interface : Motorized Faders, No. of fader : 16, Availability of master fader : yes, DSP (Digital Signal Processing) : Yes, In built effect : yes, No. of effects : 10-12, Frequency Response : 20 Hz to 20 Khz ± 1dB, Total Harmonic Distortion <=0.1%, Signal to Noice Ratio (DB) : 70-80 dB, Gain control (for each input channel) : Yes, Equalizer (for each input channel) : 3 Step, No. of Mic input channel with XLR (Balanced) : 12, Phantom power supply (for each mic channel) : 48V, No. of line input (Mono) 1/4\\" TRS : 12, No. of line input (Stereo) 1/4\\" TRS : 4, No. of main mix output XLR Mono : 1, No. of main mix output stereo XLR : 2, No. of AUX sends XLR :10-12, No. of AUX input channel 1/4\\" TRS : 2,No. of MIC/LINE (Stereo) input channel XLR : 2, No. of USB Type B : 2, No. of main mix output 1/4\\" TRS Stereo : 2, No. of monitor output 1/4\\" TRS : 1, Headphone output 1/4\\" TRS :1,No. of speaker output channel RCA Pin jack : 1, Digital Signal Processing with an Accoustic Echo Cancellation up to 60 dB or betterNoise Cancellation Digital Signal Processor should perform Noise Cancellation upto 20 dB for Podium and Cordless Microphones.Equalisation Required 3-5 StepsControl- Should have RS 232/Ethernet control through 3rd Party Control SystemFrequency Response 20 Hz to 20 KHz ± 1 dBDynamic Range 100dB or Better, Compliance BIS, ROHS and ISO 9001 |
| 5 | Mounting type : Portable Mixer, Fader mechanism : Sliding, Master output control : Yes, Salient Feature : Channel MUTE Switch provided (for each input channel), channel fader control, Peak LED for signal clipping.Accessories : As required including USB cable, Power supply : 230+- 10V, 50Hz, Warranty : 3 years onsite, OEM test report is required. |
| 6 | Hnadheld/Cordless Cardioid Microphone with Compatible Receiver operating in approved BW (Frequency)Signal Type Digital, Connector- XLR, Interface XLR, Operating Range 60mBattery Lithium-Ion rechargeable Batteries, Frequency Response 50 Hz to 15 KHzTHDN at 1 KHz <0.5%, Operating Temp 0 to 50 ° C, Gain Adjustment Range 10dBRF Transmitter Output 10mW,Housing Molded ABS, Power 12-15V DC,Output Impedance 200 Ohm, O/P Level -27 dBV across 100 KOhm loadRF Sensitivity -105 dBmDynamic Range 120 dBA, Max SPL 146dB, Sensitivity 1.85 mV/Pa, H≈25 cm,Weight≈250-300 gram |
| 7 | Wall Mount Speakers (600Watt) |
| 8 | System Type Passive 15\\", Two way,Bass-Reflex |
| 9 | Maximum SPL Output ≈ 124dB (Continuous), 130 dB Peak |
| 10 | Frequency Range 40Hz to 20 KHz ≈-10dB |
| 11 | Frequency Response 55 Hz to 20 KHz ≈-3 dB |
| 12 | Sensitivity 95dB |
| 13 | System Power Rating 3200W Peak, 1600 W Program, 800 W Continuous |
| 14 | Nominal Impedance 8 Ohm |
| 15 | Inputs NL4 Input and NL 4 Loop thru |
| 16 | Operational Modes Passive/Bi-Amp |
| 17 | Stage Monitor Speaker |
| 18 | LF Driver Required |
| 19 | HF Driver Required |
| 20 | Coverage Pattern 90X50 |
| 21 | Crossover Frequency 1.9 KHz |
| 22 | Enclosure Duraflex coated Plywood |
| 23 | Monitor Angle 50° |
| 24 | Suspension/Mounting Wall mounting according to supplied model |
| 25 | Handles 2-3 |
| 26 | Finish Duraflex finish |
| 27 | Grille Powder Coated, 14 Guage performated steel |
| 28 | Dimensions (H x W x D) ≈480 mm X 460 mm X 700 mm |
| 29 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil |
| 30 | Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in :All kinds of soil |
| 31 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kinds of soil Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia |
| 32 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 33 | CARRIAGE OF MATERIALS Earth, Sand, Lime, Morrum manure or sludge For 10 Km. |
| 34 | Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of earth |
| 35 | Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. |
| 36 | Granular Sub-Base with Close Graded Material (Table:- 400-1) Plant Mix Method Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means. For Grading-I Material |
| 37 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 38 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . |
| 39 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 40 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 41 | Random rubble dry stone Kharanja under floor. |
| 42 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 43 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix |
| 44 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 45 | Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. |
| 46 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 47 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 48 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. |
| 49 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 50 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand) |
| 51 | Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 52 | Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 53 | Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry . |
| 54 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Kota stone minimum 30mm thick. |
| 55 | Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification : |
| 56 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Good quality South Black :Above 3601 Cm2 Slabs |
| 57 | South (Red) ::Above 3601 Cm2 Slabs |
| 58 | South Zed Black :Above 3601 Cm2 Slabs |
| 59 | Extra for providing edge moulding to 15-18 mm thick marble/Granite stone counters, vantities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work (Full Edge moulding) |
| 60 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete |
| 61 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete |
| 62 | Making of hole in R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EI.:From diameter 100mm to 150mm |
| 63 | Crazy marble stone flooring 20mm thick marble stone with black or of specified colour topping including filling the gaps with cement marble chips mix in proportion of 4 : 7 (4cement : 7 white black or white or black marble chips) size from 1mm to 4mm by volume and under layer of 25mm thick cement concrete [1:2:4, graded stone aggregate 12.5mm nominal size] rubbing and polishing and cement slurry etc. complete :In ordinary cement. |
| 64 | Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. |
| 65 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 66 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement |
| 67 | Fine grinded Gangsaw cut 30-35 mm thick stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI.Red sand stone (Karauli stone) |
| 68 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 69 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab from 2001 to 5000 Sqcm |
| 70 | Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.: Rajnagar 1st quality/Ageria with light spots. Above 3601 Cm2 Slabs |
| 71 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 72 | Extra for Mirror polishing on terrazzo/Kota stone work where ever required to give high gloss finish complete. |
| 73 | P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. 600*600 mm |
| 74 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 75 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 76 | Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles. |
| 77 | Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size. |
| 78 | M-50 100mm thick to be used in heavy-traffic ( Heavy traffic is defined as a daily traffic of 450-1500 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 2.0 to 5.0 MSA for a design life of 20 years.) like Bus terminals, industrial complexes, mandi houses roads on expansive soils, factory floor , service station, industrial pavements.etc. |
| 79 | Providing and fixing designer cement concrete polished tiles over 20mm average thick base of CM 1 :4 (1 Cement : 4 sand) jointing with cement mortar 1 :2 ( 1cement : 2 sand) with pigment to match the shade of the tiles having minimum thickness of 25mm complete with all respect. ( as per IS 1237:2012) Category ‘C’not denated on any it’s faces like Hexagon, Rectangular, square shape as per IRC SP 63:2004 |
| 80 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 25 mm thick. |
| 81 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 12 mm thick. |
| 82 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 20 mm thick. |
| 83 | 6mm cement plaster to ceiling of mix 1:3 (1 Cement : 3 fine sand) |
| 84 | Finishing with neat cement (punning). |
| 85 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 86 | Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as per approved design |
| 87 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 88 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 89 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including prime coat and protecting coat including scaffolding and safety provision.Trowel Finish av. thickness 1000 to 1200 microns. |
| 90 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision :New Work |
| 91 | Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. |
| 92 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners, junction with polymer mixed slurry. |
| 93 | Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:2:4 light concrete , using brick bats complete leveling and dressing the surface by 50 mm thick cement concrete 1:2:4 as per specification |
| 94 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 95 | Grading roof for water proofing treatment with water proffing compound. Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 96 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A': 35 mm thick .Decorative teak veneer One side |
| 97 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 98 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 99 | Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter to be measured). |
| 100 | Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm |
| 101 | Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 102 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 103 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 104 | Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. |
| 105 | Extra for providing D type pipe head as top of hand railing |
| 106 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 107 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 108 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).:Grade 304 |
| 109 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge |
| 110 | Window openable. |
| 111 | Window fixed. |
| 112 | Extra for additional shutter in pipe section windows with wire gauge 14 mesh x 24 gauge |
| 113 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 114 | Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge |
| 115 | Providing and fixing Almirah lock (50 to 70 mm size )of approved make without pair of handles for door with necessary screws etc complete as per direction of Engineer-in-charge. |
| 116 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. |
| 117 | Providing and fixing to existing door frames. : 30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter). |
| 118 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). |
| 119 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion :Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 120 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 121 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 122 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.):With float glass panes of 8 mm thickness |
| 123 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.:With stainless steel cover plate |
| 124 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 125 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.: Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 126 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 127 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. |
| 128 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with (Bevelled Tegular) EDGE TILES WITH 15 mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99% NRC 0.5, Light Reflectance _>85%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600 x 600 x 16 mm, suitable for Green Building application, with Recycled content of 32 %. The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/Sqm minimum pull out strength of 100 kgs. Silhouette, Main Runners & Cross Tees to have mitred ends & \\"birdsmouth\\" notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per sqm and need to be installed with suspension system of make. The Tile & Grid system used together should carry a 30 year warranty. INSTALLATION :- To comprise main runner spaced at 1200 mm centres securely fixed to the structural soffit using suspension system (Specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450 mm from the adjacent wall. Flush fitting 1200 mm long cross tees to be interlocked between main runners at 600 mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600 mm module to be formed by fitting 600 mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000 x 19 x 19mm, secured to walls at 450 mm maximum centers. SUSPENSION SYSTEM consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26x 25x1.2 mm with a Galvanised Thickness of 80 gsm, A pre Straightened Hanger wire of dia-2.5 mm of 1.8 m length., thickness of 80 gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8 mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner. |
| 129 | Providing and laying wooden flooring with a direct laminated surface treated with aluminum oxide on top of a high-density fiber board with a density of 850 Kg./per Mtr. having a click system tongue and groove joint to secure a long lasting joint. The planks are or termite resistant and water protected with both side lamination Wooden flooring Planks of size 1208 x 194 x 8 mm / 1215x294x8 mm (8mm thick laminated floor class of use 23/31 having a wear resistance level of AC-3 , impact resistance > 9mm, moisture resistance 3-10% as per (EN-424, EN – 438 EN – 425 EN – 417 – 2)or PREN 3329 complete in all respect as per direction of EI |
| 130 | Providing and laying of skirting 89 mm wide having both side laminations with moulding in upper side with matching of floor fixing with nails and screws & fevicol complete in all respect as per direction of EI. |
| 131 | Providing and laying transaction/adaptation profile with fixing of nails, screws & fevicol complete in all respect as per direction of EI. |
| 132 | Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. |
| 133 | Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : 12mm thick Acoustical Board |
| 134 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. |
| 135 | P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 136 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge |
| 137 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: WVC with C.P. brass bend. |
| 138 | P & F water closet Seat Covers with brass hinges complete : -do-white |
| 139 | P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make : (-do-) concealed 25mm nominal bore. |
| 140 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610x400x80mm.. |
| 141 | P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make. For 1 Urinal |
| 142 | P & F C.P. brass Urinal Spreader for stall urinal of approved make. |
| 143 | P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. Makrana `Albeta` Marble having light streaks. |
| 144 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm dia for counter top |
| 145 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. Overall size 45 x 20 x 8 Bowl size 20x16x8 (with drain board) |
| 146 | P & F Bottle Trap of approved make :C.P Brass 32 mm |
| 147 | P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm |
| 148 | P & F Acrylic Toilet accessories set consisting of Towel rail, shelf, towel ring, soap dish, paste & brush holder & twin peg of approved quality/make. |
| 149 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 150 | 15 mm nominal size |
| 151 | 20mm nominal size |
| 152 | 25 mm nominal size |
| 153 | 32mm nominal size |
| 154 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) |
| 155 | 15 mm nominal size |
| 156 | 25 mm nominal size |
| 157 | 40 mm nominal size |
| 158 | 50 mm nominal size |
| 159 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). 20mm nominal size |
| 160 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).:50 mm nominal size |
| 161 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: |
| 162 | C.P. Brass bib cock,15mm nominal bore. |
| 163 | (-do-) Long body, 15mm nominal bore weight not less than 690 gm |
| 164 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. :---do--- with 37 cm long pipe and nut. |
| 165 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make:(-do-) 1350gm. 25 mm nominal bore. |
| 166 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 167 | Gun-metal 15mm nominal bore. |
| 168 | (-do-) 25mm nominal bore. |
| 169 | (-do-) 50mm nominal bore. |
| 170 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :(-do-) wt.Not less than 1200 gm 50mm. |
| 171 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 172 | 75 mm dia |
| 173 | 110 mm dia |
| 174 | 160 mm dia |
| 175 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 176 | Coupler (socket) 75mm dia |
| 177 | Coupler (Socket):110 mm dia |
| 178 | Plain Tee 75mm dia |
| 179 | Plain Tee 110 mm dia |
| 180 | Bend 87 .5 75mm dia |
| 181 | Bend 87 .5 110 mm dia |
| 182 | Door Bend (Top Side) 75mm dia |
| 183 | Door Bend (Top Side) 110 mm dia |
| 184 | Pipe Clip 75mm dia |
| 185 | Pipe Clip 110 mm dia |
| 186 | Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc.:PVC pipe 160 mm dia |
| 187 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 188 | 75 mm dia |
| 189 | 110 mm dia |
| 190 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 191 | Coupler |
| 192 | 75mm dia |
| 193 | 110mm dia |
| 194 | Bend 87.5 Dg. |
| 195 | 75mm dia |
| 196 | 110mm dia |
| 197 | Pipe Clip |
| 198 | 75mm dia |
| 199 | 110mm dia |
| 200 | Single Tee with Door |
| 201 | 75mm dia |
| 202 | 110mm dia |
| 203 | Nahni Trap without Jali 4” :110mm dia |
| 204 | Vent Cowel :75 mm |
| 205 | Vent Cowel :110mm dia |
| 206 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete (Width W= Diameter of pipe in Cm+30 Cm.)( Excluding cost of pipe) :150mm dia S.W. pipe |
| 207 | Construction of Cement Concrete Chamber 125mm dia on depressed floor upto 45cm height from floor with :C.P. Brass grating |
| 208 | Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. |
| 209 | Depth up to 0.5 M |
| 210 | Add extra over item 3.19.1 for every additional 0.10m depth above 0.5 m depth. |
| 211 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. |
| 212 | Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame. |
| 213 | -do- size 600 x 450mm depth upto 0.5 M Cement cover with frame. |
| 214 | P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.:Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm. |
| 215 | Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- |
| 216 | Size 230 x110 x150 cm.(for 20 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. |
| 217 | Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. |
| 218 | Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia 90 Cm & 10 to 12 Mtr deep. |
| 219 | Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete : 300mm dia Internal |
| 220 | Supplying and fixing Ferro- cement cover with C.I. frame for chambers & man holes of size.: Rectangular shape 600 x 450 mm, to withstand 3 MT center point load & minimum unfractured load of 1 MT. (Light duty). |
| 221 | P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete. |
| 222 | Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost: in rows 7.5 cm apart in either direction |
| 223 | Digging pits in ordinary soil and refilling the same with the excavated earth mixed with manure in the ratio of 2:1 by volume ( 2parts of stacked volume of earth after reduction by 20% 1 part of stacked volume of manure after reduction by 8%) flooding wit |
| 224 | Supply of different varieties of bougainvillea in ply bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete .Local variety of bougainvillea 600mm to 900mm |
| 225 | Supply of different varieties of rose plants in poly bag/ earthen pot according to height growth and age of the plant at site including loading unloading and transportation etc. complete .Desi rose / root stock plant |
| 226 | Tube well |
| 227 | Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion/ rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I -& II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir-rope, wherever necessary, for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water). 200 mm Nominal bore. |
| 228 | Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. |
| 229 | Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work. 200 mm Nominal bore of pipe |
| 230 | Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200mm Nominal Bore. |
| 231 | S & F tube well cover of M.S.sheet (6mm thick) with nuts and bolts complete for casing size: 200mm dia |
| 232 | S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 233 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 234 | Short point (up to 3 mtr.) |
| 235 | Medium point (up to 6 mtr.) |
| 236 | Long point (up to 10 mtr.) |
| 237 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copper earthconductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P- III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, roundtiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceilingrose / holder / 3 way connector ,Modular face plate with grid plate,screws, making connections, testing etc. as required. For specificationof copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiringaccessories refer Chapter E - 04, E - 05 & E - 07 For additional technicalparameters of product / work refer Annexure 'A' attached with this BSR |
| 238 | Long point (up to 10 mtr.) |
| 239 | Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 240 | On board |
| 241 | Medium point (up to 6 mtr.) |
| 242 | Long point (up to 10 mtr..) |
| 243 | Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR |
| 244 | Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Lightfixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity /transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , withShort & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) ,maximum power consumption should not more than the specified rating and Fixture shall be of BISstandard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LEDfixtures. (LM79 &LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer incharge. All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \\"A\\" attached with this BSR . |
| 245 | Surface Moutning |
| 246 | Minimum lumen output 4200 lm |
| 247 | Recessed Moutning |
| 248 | Minimum lumen output 4200 lm |
| 249 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 250 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 251 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR |
| 252 | 9 Watt |
| 253 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD MidPower LED Downlight with power coated die-cast aluminum housing with UV Stabilizednon yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, withShort & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with ,70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures.(LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approvedby Engineer in charge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR . |
| 254 | Recessed Mounting |
| 255 | Minimum lumen output 650 lm |
| 256 | Minimum lumen output 1950 lm |
| 257 | P & F 1.00mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 258 | Providing & Fixing of BEE Star rated copper wounded double ballbearing capacitor start, aluminium body & Metallic blade ceiling fanConforming to all the performance requirements laid down in IS374:2019 including all amendments, as applicable ; & Carry BIS licensing(i.e. ISI marking) with down rod up to 80 cm with secondary supportsafety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulatedflexible copper conductor making connection testing etc. as required. Allas per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with thisBSR . |
| 259 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 260 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm lengthextended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A'attached with this BSR |
| 261 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISImarked (IS 11037:1984 ) with CM/L no. printed made out of unbreakableand fire retardant vergin poly carbonate with brass terminals and captivescrews & silver alloy contact tip with IP-20 rating , including all as per preapproved by Engineer in charge,making connections, testing etc. asrequired. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR |
| 262 | 5 step fan regulator 2 Module 360 dgree rotating |
| 263 | Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR |
| 264 | 300 mm sweep |
| 265 | Providing & Fixing of Heavy duty capacitor start, copper wound Doubleball bearing 900/1400 RPM single phase Exhaust fan conforming toIS:2312 ISI marked in existing opening including making connectionstesting etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . |
| 266 | 380 mm sweep(900/1400 RPM) |
| 267 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 268 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 269 | 4 Way |
| 270 | 12 Way |
| 271 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 272 | 6 Way (6+2) |
| 273 | 12 Way (12+2) |
| 274 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 275 | Double pole MCB(With B/C curve tripping Characteristics) |
| 276 | 6 A to 32 A rating |
| 277 | Single pole MCB (With B/C curve tripping Characteristics) |
| 278 | 6 A to 32 A rating |
| 279 | Triple pole MCB (With B/C curve trippingCharacteristics) |
| 280 | 50/63 A rating |
| 281 | Four pole MCB (With B/C curve tripping Characteristics) |
| 282 | 6 A to 32 A rating |
| 283 | 50/63 A rating |
| 284 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L &S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face andcentralised adjustable, trip free mechanisum, true contact positionindicator, line load interchangeability, designed for both horizontal &vertical mounting without any adverse effect on electrical performance,suitable for operation upto 55 degree and without derating upto 40degree, pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breakingcapacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock &rotary handle , including making connections etc. as required.OEM shallhave submit NABL / CPRI / ERDA accrediated lab type test certificatebefore execution All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR |
| 285 | 4 pole MCCB With Thermal Magnetic release |
| 286 | Upto 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 287 | 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 288 | 400 Amp , 50 kA |
| 289 | Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR |
| 290 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 291 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 292 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 293 | 3x 1.5 sq.mm |
| 294 | 1 x 4.0 sq.mm |
| 295 | 1 x 1.5 sq.mm |
| 296 | 4 x 6 sq.mm |
| 297 | 4 x 10.0 sq.mm |
| 298 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure 'A' attached with this BSR |
| 299 | 20 mm |
| 300 | 25 mm |
| 301 | 32 mm |
| 302 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %,Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware /PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testingetc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additionaltechnical parameters of product / work refer Annexure 'A' attached with this BSR |
| 303 | 4.0 Sq. mm |
| 304 | 3 core |
| 305 | 6.0 Sq. mm |
| 306 | 3 core |
| 307 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 308 | 35.0 Sq. mm |
| 309 | 3.5 core |
| 310 | 50.0 Sq. mm |
| 311 | 3.5 core |
| 312 | 10.0 Sq. mm |
| 313 | 4 core |
| 314 | 95.0 Sq. mm |
| 315 | 3.5 core |
| 316 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 317 | 4.0 Sq.mm |
| 318 | 6.0 Sq.mm |
| 319 | 10.0 Sq.mm |
| 320 | 35.0 Sq.mm |
| 321 | 10.0 Sq.mm |
| 322 | 50.0 Sq.mm |
| 323 | 95.0 Sq.mm |
| 324 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 325 | 50 mm |
| 326 | 63 mm |
| 327 | 90 mm |
| 328 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 329 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 330 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 331 | 8 SWG G.I. ( Hot Dipped ) Wire |
| 332 | 10 SWG copper. Wire |
| 333 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 334 | 32mm x6mm G.I. ( Hot Dipped ) Strip |
| 335 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 336 | LED Street Light fixture with Minimum lumen output 8700 lm |
| 337 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 338 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 339 | 32 mm Dia. |
| 340 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 341 | RJ-11 telephone jack single line |
| 342 | RJ-11 telephone jack Double line |
| 343 | Modular MCB 6 A to 32 A SP |
| 344 | P & F Krone module with base frame in the recess / surface made out of1.2 mm thick sheet steel box, front openable, having locking arrangementsduly powder painted,including dressing, ferruling and punching oftelephone cable with krone tool etc. as required. For additional technicalparameters of product / work refer Annexure 'A' attached with this BSR |
| 345 | 10 Pairs |
| 346 | Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 347 | RG - 6 |
| 348 | Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic gradebare Copper Conductor as per IS: 8130/84 &confirming to TECspecification GR / WIR/06-03 March 2002 in existing surface orrecessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR |
| 349 | 10 pair |
| 350 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 351 | Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 352 | Cat 6, Un-sheilded Information Outlet |
| 353 | Cat 6A, Sheilded Information Outlet |
| 354 | Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 355 | Single Aperture |
| 356 | Dual Aperture |
| 357 | Supply, Installation, Testing and Comissioning of Rack mounted 19\\" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 358 | Modular Patch Panel Loaded with Cat -6 I/O |
| 359 | Supply, Installation, Testing and Commissioning of L2 managed Switch; 24X 10/100/1000 BASE-T port and with min 4x 1000/10000 BASE-X SFP (With 2 SFP module for Fiber Giga Connectivity); Total power budget: Minimum 350 W. Switching Capacity 56 GBPS or better; MAC Table 8K or better. Rack mounting; flow Control; QoS; 802.l Q Standard VLAN, Network Management; Wide working temperature: -05-55°C; Lightning Protection Common mode 4KV; Certificate of compliance: CE/FCC, including making connections etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with P.W.D. Electrical B.S.R. 2022. |
| 360 | Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patchcords should be constructed of minimum 23/24 AWG, stranded bare Copper cable withFRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectorswith strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A applicationcomplying to latest ammendments Category 6/6A Standards, According. to TIA568C.2,ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirementfor 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cablecompatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af /IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts forlong durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digitalvideo and broadband/baseband analog video, Voice over internet protocal (VOIP).All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR . |
| 361 | Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord |
| 362 | 1 Mtr |
| 363 | Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 364 | 6 fiber |
| 365 | SITC of IR IP Based 5 MP Dome camera : 1/2.8\\" Progressive CMOS, ICR, IR, 2560(H)xl920(V):25fps(P) , 2.8/3.6 mm lens (As per site requirement) H 264,H265/MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: minimum 30 Mtr, Provision for Support on-board storage up to 256 GB (SD card not included), intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G}, Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : 20°C - 50°C or better. Model should be: CE, BIS,/UL,FCC,ROHS compliance. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR. |
| 366 | SITC of IR IP based 5 MP Bullet Camera 5 MP, Video Resolution: 2592(H)x1944(V) Pixels , 1 to @25 fps; Image Sensor: 1/2.8-inch CMOS; Built in Infra-Red: 40 to 50 Mtr; High Dynamic Range- 120 dB WDR; Lense- 2.8/3.6 mm, ;H264,H265/MJPEG, provision for Support on-board storage up to 256 GB (SD card not included) , intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : -30°C to + 70 °C or better. Onvif Profile S, G, Confirmant; Model should be: CE, BIS,/UL, FCC, ROHS compliance The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \\"A\\" attached with this BSR. |
| 367 | Supply, Installation, Testing & Commissioning of 16 Ch NVR Pre-licensed, NVR supports up to 40 TB HOD Support, 16 Ch IP inputs; Support ANR technology; 320mbps incoming bandwidth, supports up to 12MP full channel recording; support H.265 compression; 16ch synchronized playback @1080p; support 3rd party cameras ONVlF type; 4K output; minimum 04 SATA HDD Slots; each slot should support up to 10 TB HDD; Dual gigabit self-adaptive Ethernet interface; serial interface; USB interface; (all cameras and Storage-NVR should be of same make for the smooth functioning of the system) complete with mounting accessories & junction box (to be provided by OEM) for cable management. Model should be: Certificates of Compliance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan. All as per pre approved by Engineer in charge. For additional technical parameters of products/work refer Annexure \\"A\\" attached with this BSR. |
| 368 | Supply, Installation, Testing & Commissioning of 3.5\\" 6 TB SATA, USB 3.0 Surveillance Hard Disk. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attachedwith this BSR |
| 369 | Supply, Installation, testing and commissioning of BIS compliance Professional series Diagonal Screen size 43\\" LED with Resolution 3,840 x 2,160 (4K UHD) along with Static (Panel) Contrast Ratio (1300:1) or better with viewing angle of 178/178 degree with response time of 8rns along with HDMI In 2.0 - 2 nos., USB 2.0 2 nos., RS 232- 1 nos., RJ 45- 1 Nos. with Built in Speaker (10W + 10W), with high speed processor and android or other reputated operating system along with 4 GB RAM along with all audio and video decoder, Stand-by/ sleep/ off mode power 0.5 watt. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR. |
| 370 | SITC of 8 port Giga PoE Switch with dual uplink : unmanaged PoE switch; 8Xl0/100/1000 mbps Base-T PoE; 2*10/100/1000 Base-T(Uplink) or 2*1000 Base-X (uplink); PoE Power Consumption per Port: <=30W; power budget: minimum 96 W; PoE Protocols: IEEE 802.3af, IEEE 802.3 at ;Switch Capacity: 20 Gbps or better; MAC Table Size 2K or better; Working Temperature: -5°C-55°C; Power supply:DC48-57V Certificate of compliance: CF/FCC. A11 as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with P.W.D. Electrical B.S.R. 2022. |
| 371 | Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 372 | 1.5 TR ISEER not less then 3.8 |
| 373 | Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 374 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 375 | 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 376 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 377 | 20 mm |
| 378 | 25 mm |
| 379 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 380 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 381 | Poles with Octagonal Cross Section |
| 382 | 3 Mtr. |
| 383 | 5 Mtr. |
| 384 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 385 | Single arm overhang |
| 386 | Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability, including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 387 | Capicity 4.5 KG |
| 388 | Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 389 | Providing & Fixing of ISO Certified company made lightning conductor finial as per PWD specification for electrical Works as per IS 2309-1989 made out of 25 mm dia.,300 mm long G.I. solid Rod having single prong at top with 85 mm dia., 3 m thick G.I. base plate including holes etc. complete as required. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 390 | Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 391 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 392 | (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts |
| 393 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 394 | (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. |
| 395 | (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. |
| 396 | (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 397 | 25 mm thick and 3 Mtr. Long |
| 398 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 399 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 400 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box |
| 401 | 4 Way |
| 402 | Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,front sturdy sheet steel frame folded from one piece and welded with minimum 5mmtoughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All roundprotective channel on the door aperture, lock integrated on front door, top and bottomcover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angleswith wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cablemanager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long powerchord for supplying power to switches, fans etc along with earth continuity kit, indicator,moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.Allas per pre approved by Engineer in charge. For additional technical parametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR . |
| 403 | 9 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 404 | 6 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 405 | 15 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 406 | Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 407 | Minimum lumen output 4500 lm Post top Luminarie |
| 408 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 409 | (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided |
| 410 | (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 411 | [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 412 | (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 413 | (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. |
| 414 | (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) |
| 415 | (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 416 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 417 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 418 | Electrolytic grade Aluminium bus bar 6010 grade |
| 419 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 420 | Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS |
| 421 | Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 422 | Ring type tape wound CT |
| 423 | C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA |
| 424 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 425 | Red/yellow/Green colour |
| 426 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 427 | 3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 428 | P & F of Automatic Transfer Switch (ATS) confirming to IEC60947-6-1, Utilization cateogory AC-33B in Existing panel for automatic on load transfer between two source power supply of 415V through Solenoid/Motorised mechanism and integrated with three positions realize fast transfer within 100 ms. ATS shall have three postions (S1-OFF-S2) , Manual / Auto Override feature, The two sources can be isolated in the off position with a padlock. capability to expand with RS 485 communication module, which can ensure real-time transmission of communication data. ATS shall have automatic generator start & stop control function; Auxillary contacts to indicate mechanical positions. Minimum Electrical operations 6000, of following Current ratings, including making connections etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 429 | 125 Amps |
| 430 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 431 | Four pole 100/300 mA sensitivity |
| 432 | 100 A rating |
| 433 | Providing & Fixing of IP20, 1100-1200 mm x 50-60 mm x 70-85 mm size Suspended mounting Mid power SMD type LED linear Light fixture made from Extruded Aluminium housing, PMMI diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 100 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 434 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 435 | Minimum lumen output 2000 lm |
| 436 | Supply , Installation, Testing and Comissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, +/- 10% 50 Hz ,1 /3 phase AC supply, apable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll /rotary/twin rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 437 | Inverter Type |
| 438 | 2.0 TR ISEER not less then 3.5 |
| 439 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 440 | 50 mm dia per running inch length |
| 441 | BSR 2025 |
| 442 | SITC of 3 Phase input, 3 Phase output online Double conversion VFI-SS-111 IGBT based Rectifier and Inverter UPS with 0.99 input PF & unity outputpower factor (KVA=KW), having inbuilt Isolation Transformer aty Input, Phase Balance of 120° ± 1° (100 % unbalanced load), input voltage & frequency range of 320-480 V & 45-55 Hz and out put voltage 415 V(± 1% for balanced & ± 2% for unbalanced load) and out put frequency of 50 Hz± 0.1 Hz.UPS should have inbuilt phase sequence corrector & protector both (UPS should correct the Input Phase Reversal Condition & shall not go to Battery Mode) and input, output & bypass breaker, UPS should have inbuilt static & maintenance bypass, Parallel kit, EPO, dust filter & conformal coated boards, Overall efficiency without transformer loss (93% for 10KVA, 94% for 20KVA & 30KVA, 95%) for 40KVA& 60KVA) Overloading on mains mode 110% for 60 mins, = 125% for 10 mins, =150% for 1 min, THDi < 4%. UPS should have LED Panel with minimum 5-inch Intuitive Touch Screen LCD Display showing UPS status with other parameters like Input, Output, Bypass Voltage/ Frequency, load%, Battery%. UPS should have protection from Input High/Low; Over Load; Short Circuit; Over Temperature and give audible alarms on Battery Mode; Low Battery; Fault; Over Load & Bypass Mode. UPS communication through RS485. SMF Batteries of 12V VRLA for 30 min back up with MS Rack having battery breaker with enclosure and necessary cable for UPS to Batteries Installation of 20 Mtrs. UPS should have feature to connect similar model & capacity with common battery bank. Operating Temperature of UPS 40-degree, relative humidity 0-95% (Non condensing), Noise level of 65dBA @1 mtr. UPS should have CE, ROHS, IEC62040-1,2&3 compliance and should have QR code which should contain drawing, test report OEM manual, Geo-Tag of manufacturing location Etc. as required. BSR 2025 |
| 443 | 10 KVA UPS with 10080 VAH 12 V SMF Battery Bank |
| 444 | SITC of following diagonal size professional Display, 4k Resolution, Brightness(Typ.) 440 nit and above Contrast Ratio-2000:1 and above, Viewing Angle(H/V)-178/178, Response Time(G-to-G) 8ms, Input: RGB- Analog D-SUB, Video- HDMI 2.0 (2), HDCP- HDCP 2.2, Audio- Stereo mini Jack, USB- Only F/W upgrade, Outputs: DP1.2(Loop- out), Audio Stereo mini RGB-Jack, External Control- RS232C(in/out), RJ45, External Sensor Detachable type(IR Ambient). Operation Hour 24x7, mounting bracket etc. as required. |
| 445 | 65 \\" LED Display |
| 446 | Supply, Installation, Testing Commissioning of Chairman Unit with fixed microphone and flexible stem priority button for chairman microphone optional chime tone facility for proceeding chairman announcement with two headphone socket built in loudspeaker is automatically muted when the microphone is on/off button chairman mike unit should have a frequency response 400hz to10hz, length of microphone from base to steam should not be less than 488 mm in size ;nominal acoustic input 85 db SPL, dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg; operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets; including make connection testing etc. complete as required. |
| 447 | Supply& laying of 8 core shielded cable for extension cable for contribution unit /control unit interconnection making connection testing etc. complete as required. |
| 448 | SITC of 30 Watt speaker with taping facility having frequency range of 65Hz-20KHz@(-10db) with power handing of 200Watt continuous and more than 350 Watt @peak etc. complete as required. OEM test certificate to be attached. |
| 449 | supply, Installation, Testing Commissioning of Delegate mike Unit with fixed microphone and flexible stem priority button for Delegate mike microphone, optional chime tone facility proceeding Delegate for mike announcement with two headphone socket built in loudspeaker is when the automatically muted microphone is on/off button Delegate mike unit should have a frequency response 400hz to10hz length of microphone from base to steam should not be less than 488 mm in size;nominal acoustic input 85 db SPL, dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets: including make connection testing etc. complete as required. |
| 450 | Supply and laying speaker cable of following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/above false ceiling including cost of Gl spacers, saddles etc. as required. |
| 451 | 1.5 sq mm |
| 452 | SITC of highperformance 15 mtr. HDMI cable male to HDMI male cable wall plate for the interoperability in all respect etc. complete as required. |
| 453 | Supply, Installation, Testing & Commissioning of Control Unit for giving power to chairman unit and delegate unit with inbuilt 3 band equalizer unit comprising of knobs at 250hz, 2khz and 8khz volume control for 1 mic input 8 pin din connector for loop through should also consists microphone input with xlr connector with rated output impedance of 1000ohm and systems should have capability to control up 50 discussion unit, unit dimensions should not be less then (85mm x 360mm x 250 mm) in size; including make connection testing etc. complete as required. |
| 454 | SITC of 240 Watt Mixer Amplifier Unit- for providing a crisp call or clear music with 4 microphone / line inputs, plus music source input, announcement only output, 3 wire volume override, with Mains power supply 230 VAC ±10%, 50 Hz (reduced power at lower mains), Inrush current 20 A Power consumption 120W, Frequency response (Line) 80 Hz to 18 kHz (+1/-3 dB @-10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/-3 dB @-10 dB ref. rated output) Distortion <1%@ rated output power, 1 kHz Bass Control Max. ± 8 dB Treble Control Max. ± 8 dB, including making connection etc. complete as required. |
| 455 | SITC of Grid interactive Solar Photovoltaic |
| 456 | Power Plant of required capacity having specifications as per A, B, C, D, E, F and G |
| 457 | (a) Solar Photovoltaic module: MNRE approved and ALMM listed, SPV module of capacity 580 Wp or above, Anodized Aluminium Alloy Framed Topcon N- type Bifacial, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. , 2 |
| 458 | mm Low Iron ARC semi-tempered glass, IP-68 PPL Junction box, 4.0 sq.mm cable with MC4 solar connector, conversion efficiency shall not be less than 21.0 % on STC, performance warranty for their output peak watt capacity > 90 % at the end of 10 years and > 80% at the end of 25 years. |
| 459 | (b) Inverter / PCU MPPT integrated, IGBT/MOSFET based and microprocessor/ DSP controlled Power Conditioning Unit (PCU) of AC nominal power output rating equal or greater than the required KWp of the module in IP-65 Enclosure, of 250-1500 V DC Input voltage range and 400 V AC, TPN, 50Hz +/- 2.5 Hz, Efficiency > 97%, THD < 3%, Overloading capacity > / = 10%, remote monitoring facility and PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. |
| 460 | (c) Module mounting structure : MMS Steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759, All bolts, nuts, fasteners shall be hot dip galvaniz ed, MMS shall be designed and installed to withstand the speed for the wind zone of the location with factor of safety >1.5, STAAD report of Structure to be Submitted. |
| 461 | (d) Array Junction Box / DCDB IP 65 AJB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. DC fuses with SPD type- II/MOV type surge arrester to be provided.(e) ACDB IP 65 ACDB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. MCB/MCCB with SPD type- II/MOV type surge arrester to be provided.(f) Earthing and Lightning protection: The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors (LAs). as per NFC17-102:2011/IEC 62305 standard and three no. of Earthing with suitable size earth conductor(g) Solar meter and Cable : Laying of array cables to PCU/ DCDB unit along with supplying & fixing of necessary GI raceways/MS conduit lugs and suitable size aluminium armoured. BSR 2025 |
| 462 | 50 KWp Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail