Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule-A Civil Works |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | Excavation |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil. |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift |
| 8 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 9 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 10 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 11 | Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. With rapid setting bitumen emulsion On W.M.M. @ 0.4kg/sqm |
| 12 | 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately).With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering M15 grade PCC design mix |
| 14 | Providing and laying cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) M15 grade equivalent including cement slurry complete.(40 mm thick with 10 mm nominal size stone aggregate). Note: Panels shall be 3.3*3.3 m(10 ft*10 ft) with necessary expansion materials by any means preferably by metal strip in between panels and suitably placed in scattered manner and gap of laying time shall be ensured and as per EIC instruction |
| 15 | Concrete of M25 grade with minimum cement content of 330 kg /cum, All works up to plinth level. No extra payment for additional cement content if design mix requires higher cement content |
| 16 | Concrete of M25 grade with minimum cement content of 330 kg /cum, All works up to floor V levelNo extra payment for higher cement content as per design mix |
| 17 | Steel reinforcement( Thermo-Mechanically Treated bars of grade Fe-500D )or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 18 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 19 | Providing and laying double charge Vitrified tiles in floor in sizes 600*1200mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 20 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles MatVAntiskid finish of size |
| 21 | Providing and fixing cramps of required size & shape in RCC/ CC backing with cement mortar 1 :2 ( 1 cement :2 coarse sand) including drilling necessary hole in stones and embedding the clamp in the hole (fastener to be paid separately).Stainless steel clamps. |
| 22 | Providing and fixing SS - 304 expansion hold fasteners on C.C. /R.C.C. surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type Fastener with threaded dia 10 mm. |
| 23 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 24 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 25 | Cement plaster |
| 26 | Providing and laying 12 mm cement plaster on the rough side of brick wall or block masonary wall of mix : 1 (1 cement : 4 fine sand) including scafolding , curing etc. complete as per drawing, specifications and direction of engineer. |
| 27 | Providing and laying 15 mm cement plaster on the rough side of brick wall or block masonary wall of mix : 1 (1 cement : 4 fine sand) including scafolding , curing etc. complete as per drawing, specifications and direction of engineer. |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete. |
| 29 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour in two coat. |
| 30 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm |
| 31 | Excavating, supplying, stacking and filling of good earth (including royalty) by mechanical transport upto a lead and carriage of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) and as per EIC Instruction. |
| 32 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure & Sub Structure at all level in Cement mortar 1 :4 (1 cement: 4 coarse sand) |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 34 | Foundations, footings, bases of columns, etc. for mass concrete |
| 35 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 36 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 37 | Weather shed, Chajjas, corbels etc., including edges |
| 38 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per specification and as per direction of Engineering charge. Note: All necessary testing certificates shall be submitted to EIC and as per latest IS 15658. |
| 39 | Providing and laying 50mm thick PUF(Polyurethane Foam) Roofing panel consisting of a 0.5-0.6 mm thick hot dipped high tensile galvanized steel/galvalume sheets which is colour coated with Architectural Polyester, Silicon Modified Polyester, Fluoropolymer or Plastisol whereas the other side of sheet be plain with colour coating. Polyols and Isocyanates are injected between two colour coated metallic sheets kept apart for maintaining the desired thickness. The chemicals shall essentially be free from chlorofluorocarbons. The Polyurethane foam thus formed shall be closed cell. Each panel is to be completed with tongue and groove joint and to be provided with or without camlocks or as per EIC instruction to ensure rigid interlocking between two panels. Panel material should conform to specification as mentioned in IS 16203:2016 |
| 40 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance of 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized 46 @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) |
| 41 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including filling 56 necessary up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 42 | For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 43 | For shutters windows of doors & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket (Required fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 44 | Providing and fixing glazing in aluminium door, window, ventilator, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in charge With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 45 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of charge. : engineer-in- Pre-laminated particle board with decorative lamination on both sides |
| 46 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 47 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. |
| 48 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen Sink without drain board 610x510 mm bowl depth 200 mm |
| 49 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 50 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 51 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, waste pipe, etc. all complete including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 52 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. : 15 mm nominal bore |
| 53 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 54 | Providing Chlorinated Chloride 78 and fixing Polyvinyl (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls |
| 55 | 15 mm dia nominal bore |
| 56 | 20 mm dia nominal bore |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, metre refilling & testing of joints complete as per direction of Engineer in External work |
| 58 | 25 mm dia nominal bore |
| 59 | 32 mm dia nominal bore |
| 60 | 40 mm dia nominal bore |
| 61 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore |
| 62 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 |
| 63 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes 110 mm diameter |
| 64 | Providing and fixing square mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With fly ash bricks of class 10 (non modular)100x100 mm size P typeWith Sewer bricks conforming to IS : 4885 |
| 65 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 66 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 67 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 68 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 69 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 70 | Providing Float glass panes 4 mm thick glass pane (weight not less than10 kg/sqm). |
| 71 | Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weightnot less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebateshall be measured). |
| 72 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 25 mm thick |
| 73 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter |
| 74 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter |
| 75 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia |
| 76 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 77 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 78 | Providing and laying damp-proof course 50 mm thick with cement concrete 1 :2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 79 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 80 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 81 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 82 | Providing and fixing toilet paper holder : Vitreous china |
| 83 | Supply of detailed design & architectural, structural, mechanical, electrical and plumbing drawing viz. collection of all required data, including its approval from concerned and statutory authorities, providing technical assistance during execution etc complete in all respect for Gym Hall of 450 sqm area approx. Note: contractor should initially submit Drawings of Structural design with clear details of reinforcement, Concrete grade, cover and all relevant details , Plumbing layout with clear details of Pipe size & path and other relevant detail needed , Electrical Layout with clear details regarding conduit path, wire size with their recommended specifications and other relevant detail needed and Architectural drawing , (In soft copy Auto CAD as well as PDF format). complete all as per technical specifications and as directed by Engineer-in-charge. These drawings shall be pre-approved by structural Engineer before taking final approval from ASHVINI |
| 84 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, |
| 85 | All types of Soil: 300 mm dia |
| 86 | Rocky strata including boulders: 300 mm dia |
| 87 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia |
| 88 | Schedule-B Electrical WorksWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 89 | Group A (upto 10 m) |
| 90 | Group B (upto 10 to 20 m) |
| 91 | Group C (upto more than 20) |
| 92 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable etc. as required. |
| 93 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 94 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 95 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 96 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 97 | 25 mm |
| 98 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 99 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 100 | 5A switch |
| 101 | 3 pin 5A socket |
| 102 | 15/16 A switch |
| 103 | 6 pin 15/16 A socket outlet |
| 104 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 105 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 106 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 107 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 108 | 100 A,30KA,FPMCCB |
| 109 | 200 A,36KA,FPMCCB |
| 110 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. As required. |
| 111 | For 14 way, Double door SPN MCBDB |
| 112 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB/Isolator). |
| 113 | 12 way (4 + 36), Double door |
| 114 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 115 | Single pole and neutral |
| 116 | Double pole |
| 117 | Triple pole and neutral |
| 118 | Supply and installation of 2 hp submersible pump (kirsolkar /crompton/ havelles /vguard/CRI pump ) |
| 119 | supply and installation of fully automatic starter with digital display |
| 120 | supply and installation of 3 core, 2.5 sqmm submersible cable |
| 121 | 45 watt LED Panel /ceiling light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 122 | 100 W LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, 54 DELHI SCHEDULE OF RATES (E&M)-2025 EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 123 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 124 | 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 125 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 126 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 127 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 128 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 129 | Supply, Installation, Testing and Commissioning of 3-Phase, 433 V, 100 kW LT Distribution Panel with 250 A, 4-pole MCCB incomer and 6 Nos. 100 A, 4-pole MCCB outgoing feeders, complete with electrolytic grade copper busbars, conforming to IS 8623 / IEC 61439, having IP-52 protection, fabricated from CRCA sheet steel of minimum 2.0 mm thickness for load-bearing members and 1.6 mm for doors and covers, duly epoxy powder coated, complete in all respects. |
| 130 | Supply, Installation, Testing and Commissioning of 3-Phase, 433 V, 25 kW wall mounted LT Distribution Panel with Incomer 63 A, 4-pole MCCB incomer & 63A 100mA, 4 Pole RCCB and 12 Nos. 6 A 2P MCB, 9 Nos. 10 A 2P MCB and 3 Nos. 16 A 2P MCB outgoing feeders, complete with electrolytic grade copper busbars, conforming to IS 8623 / IEC 61439, having IP-52 protection, fabricated from CRCA sheet steel of minimum 2.0 mm thickness for load-bearing members and 1.6 mm for doors and covers, duly epoxy powder coated, complete in all respects. |
| 131 | Supplying and drawing of 4 Core Aluminium Cable Wire for pole to meter & Meter to DB or existing setup to our DB. Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Unarmoured/ Armoured aluminium cable of 1.1KV grade as per PWD specification for electrical Works in existing RCC/ Hume/ Stoneware/ PVCpipe/ openduct/ cable trench with filling of excavated earth in trench, on existing cabletrays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a)Material:-H4-Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS8130, IS3975-1999 for armouring of cables in armoured cable items, IS5831for sheath, IS10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO9001 &14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables. Appropriate type test certificate / OEM test repor tshall be submitted. All above as per pre approved by Engineer incharge. |
| 132 | Fire Detection and Alarm System |
| 133 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 134 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 135 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 136 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set. |
| 137 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 138 | Supplying, installation, testing & commissioning of Electronic Hooter / Sounder Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy