| 1 | Finishing wall with weather proof exterior grade emulsion of approved design Apexultima Protek ) or its equarlied on undecorated wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter etc including sand paper smooth including carriage of materials in all leads as per directions of the Engineer-in-Charge. |
| 2 | Removing dry or oil bound distemper, water proofing cement paint and the like by scraping and sand papering the wall surface smooth including necessary repairs to scratches complete including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. |
| 3 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of materials in all leads and lifts as per the directions of the Engineer-in-Charge. |
| 4 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade including carriage of materials in all leads as per directions of the Engineer-in-Charge. (i) One or more coats on old work |
| 5 | Repair to plaster in patches of 2.50 square meter under and upto 10 to 15mm thick including cutting the patch in proper shape and re-plastering the surface of wall including disposal to the dumping ground with a lead of 20 metres with including carriage of mateirals in all leads and lifts as per directions of the Engineer-in-Charge. (i) Cement Mortar 1:5(One cement: Five sand). |
| 6 | Providing and Fixing Scaffolding in building side including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. (i) One or more coats on old work. |
| 7 | Providing and applying base coat for Apex Ultima Protek including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. |
| 8 | Lettering with black Japan paint of approved brand and manufacturing carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. |
| 9 | Removing dry or oil bound distemper, water proofing cement paint and the like by scraping and sand papering the wall surface smooth including necessary repairs to scratches complete including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. |
| 10 | Disposal of muck /denris/ excavated earth upto site approved by Municipal Corporation surrounding Shimla upto all leads and lifts as per directions of the Engineer-in-Charge. |
| 11 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. (i) 0.63 mm thick sheet. |
| 12 | Providing ridges or hips of width 60 cm(sixty centimetre)overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm(eight milimetre) dia G.I. limpet and bitumen washers complete including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. (i) 0.63 mm thick with zinc coating not less than 350 gm/m2 |
| 13 | Providing valleys of width 90 cm(ninty centimetre)overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts G.I. limpet and bitumen washers complete including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. (i) 1.69 mm thick with zinc coating not less than 350 gm/m2 |
| 14 | Providing and fixing of width 40 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, G.I. limpet and bitumen washers complete , bent shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand ) including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge.(i) 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 15 | Providing and fixing M.S. BP Sheet 1.66mm to 2mm thick in eaves board. Facia/ soffits/ ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-Charge (Base members of steel work shall be measured & paid separately) |
| 16 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 meteial lead of including carriage of mateirals in all leads and lifts as per directions of the Engineer-in-Charge. (i) G.S Sheet |
| 17 | Steel work welded in built up sections, trusses and framed work including cutting hoisting fixing in position and applying a priming coat of red lead paint including carriage of materials in all leads and lifts as per directions of the Engineer-in-Charge. (a) In gratings, framed guards bars ladders, railing, brackets and similar work. Please Enable Macros to View BoQ information |