| 1 | Part A: Internal Electrification |
| 2 | Wiring for Light point/Exhaust fan/Fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Anchor/Eq Make) in PVC Conduits (including Cost of PVC Conduits ) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified of Anchor Roma plus/SSK NV/ Legrand Mylinc/ABB Tvisha/ eq. Make & shall be approved before execution of work by EIC at site including 2.5 Sqmm Circuit wire. |
| 3 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/ Eq.Make) including cost of conduit |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified of Anchor Roma plus/SSK NV/ Legrand Mylinc/ABB Tvisha/ eq. make. The make shall be approved by EIC at Site. |
| 5 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq Make to be approved by EIC) including cost of conduit |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 6 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Anchor Roma plus/SSK NV/ Legrand Mylinc/ABB Tvisha/ eq. make. The make shall be approved by EIC at Site |
| 7 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly. |
| 8 | 2 X 10SQ.MM + 1 X 6 SQ.MM [Phase +N+E) For Lighting Submain in one run from Main Panel to Distribution board(Anchor/Havells/eqt make) |
| 9 | 2 X 6SQ.MM + 1 X 6SQ.MM [Phase +N+E) For Inverter/ups Sub main in one run from Main Panel to Distribution board(Anchor/Havells/eqt make) |
| 10 | 2 X 4SQ.MM + 1 X 4SQ.MM [Phase +N+E) For Inverter/ups Sub main in one run from Main Panel to Distribution board(Anchor/Havells/eqt make) |
| 11 | SINGLE POLE (6-32Amp) Legrand /Havells or L&T /Schneider/ABB/Siemens/Eq make |
| 12 | Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. |
| 13 | 32 Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/Eq make ( For inverter/ups circuit) |
| 14 | 40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/Eq make |
| 15 | 63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens/Eq make |
| 16 | Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK/ABB/eq. make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/ RCCB/ Isolator) |
| 17 | 4(4+12) way Double door |
| 18 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider/ eq. Make to be approved EIC(1) Normal Incomer:a) 125 Amp-4-Pole ,35kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider/ eq. Make to be approved by EIC as approved=01 No. b) 200 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set. 100 Amp 4-pole Change-over (3) Outgoing:(1) Normal outgoing for Heating/Lighting etc load Havells/L&T/Legrand/Schneider/ABB/ eq. Make to be approved by EIC(a) 63-Amp DP MCB = 03 No. for heating load Havells/L&T/Legrand/Schneider/ABB / eq. Make to be approved by EIC (b )40-Amp DP MCB = 03 No. for lighting and Machine load Havells/L&T/Legrand/Schneider/ABB / eq. Make to be approved by EIC (c) 32-Amp DP MCB = 03 No. for inverter circuit in Havells/L&T/Legrand/Schneider/ABB / eq. Make to be approved by EIC |
| 19 | Supply installation testing and commissioning of 9/12 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havel's or Wipro or Eq make to be approved by EIC |
| 20 | Supply installation testing and commissioning of decorative type Hanging Ligh having 3 jars in each light with 2-3 metre chain length as per site requirement and as directed by SDO.It also includes 15 Watt LED warm lamps of havells/philips/wipro/equivalent make as required |
| 21 | Supply, installation, testing & Commissioning of Bulk Head Fittings of Havel's RUGBY Model HAVEL'S /Panasonic BULK HEAD Fittings with 12watt LED Bulb of Philips or Havels |
| 22 | S/L , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Polycab/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 23 | d) 35 sq.mm 3.5 core ( armoured) |
| 24 | Supply and fixing of wooden channel/ casing made from Kashmiri budloowood having 2.6\\"-3\\" width suitable for carrying out wiring for different circuits. |
| 25 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Wipro/Philips/Eq Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 26 | Providing , Laying of 25 mm dia./32mm dia 2mm thick PVC Unbreakable conduits dully laid in slabs and to be recessed in wall including cost of other accessories like ,bends ,DEEP Junctions in First floor slab& Fan Boxes for F/F Slab, Surface junctions etc and cutting of Walls for recessing of pipes including cost of resurfacing of walls with cement plaster and making good with wall putty if required at site during execution of work . 25mmdia./32 mm dia as required |
| 27 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) feeder outdoor type Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens / eq. Make to be approved by EIC and change over switch should be of Havells/ L&T/Legrand/ Schneider / eq. Make to be approved by EIC.a) 125 Amp-4-Pole ,35kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider/ABB Make as approved=01 No. b) 200 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector.The legs of the panel should be grouted in the concrete of 1:2:4 mixture |
| 28 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job |
| 29 | Part B: Street Lighting |
| 30 | LAMP POST Supply, installation and fixing of heritage architectural ornamental decorative cast iron pole having provision to fix decorative Light fixture. Installation of same with foundation bolts of suitable size to grout it into specially designed RCC foundation, as shown in the enclosed drawing. The decorative light fixture shall be fixed on the top of the pole. The details of pole & light are given below: -A, The pole with light fixture shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing/picture. The Cast Iron Pole of nearly 2700mm length. The pole has ornamental base (Approx.overall dimension-height 1175 mm, bottom dia 360mm) shall have a provision of inbuilt junction box for fixing MCB’s or cutouts with detachable window cover. The part above ornamental base design consists of decorative chinar leaves bamboo sections of circular shapes in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%) (The poles should be dully painted as per specifications and latest IS ammended upto date)B. Light Fixture: The Cast Aluminium Light fittings best suitable for the Lamp Post shall be exactly similar as shown in the enclosed drawing/picture, which is of nearly 360mm width, 820mm height. The fixtures have aluminium casted parts & spinning parts welded with decorative cast aluminium designs for better look. It shall have provision of LED 30watt designed to illuminate large areas with its wide dispersion without affecting the environment. It shall have extra clear transparent acrylic sheet light cover with stainless-steel fastening elements. The fixture having provision to fix complete with required power supply. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%) However the light fixture design may be got fabricated slight changes to tolerate the snow load accordingly which may discussed/approved before its installation. |
| 31 | Cement concreeting of foundation for installation of decorative lamp posts (pole) in the ratio of 1:2:4 mix as per Standards/as per dimention of enclosed drawing including digging of earth pit and RCC work complete job. |
| 32 | Supply and Installation of 2.7 Mtr lamp post (cast iron pole) strictly as per the above mentioned specifications and as per enclosed drawing of Dwarika/crompton/equivalent make |
| 33 | Supply, installation, Testing and commissioning of decorative post top light fixture of Dwarika/crompton/vipin/ Equavilent make strictly as per the specifications mentioned above and as per enclosed drawing including LED lamp 25-30W |
| 34 | Supplying and laying of required/suitable size of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (30-40 cm below ground level depending upon site conditions) for carrying out cables including excavation and refilling the trench and bringing back the surface level properly. The job includes the removal of excivated surplus earth |
| 35 | Providing of an Earthing using 3ft Long Gi electrode to be driven into earth pit bottom and extending through 10 swg GI wire. The Gi wire should be welded poperly with electrode and fitted with the bollard foundation bolt. |
| 36 | S/L , testing and commissioning of LT copper wire FRLSH multistrand Cable,650 V/1100 V Grade as per IS standard.Havell/Paraflex/Eq. standard make as directed by the engineer incharge and making end termination with copper lugs of required size. The cable shall be carried through HDPE existing pipe (item no 34) |
| 37 | a) 3x4 sq.mm |
| 38 | b) 3x6 sq.mm |
| 39 | Providing power connection to the Luminaries from Junction box(gear box) using 1.5sq mm x3 multistrand copper wire FRLSH of havells/Polycab/Equivalent make |
| 40 | Providing and Fixing with crimping,taping of thimbles of required sizes |
| 41 | SINGLE POLE (6-32Amp) Legrand /Havells or L&T /Schneider/ABB/Siemens/Eq make Please Enable Macros to View BoQ information |