| 1 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each, complete all as specified and as directed. |
| 2 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm thick MS square tube of 19 gauge mitre cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mmx15mm MS square tube inside the 19mm MS square tube and suitably screwed complete all as specified and as directed. |
| 3 | S&F factory made solid panel PVC door shutter of 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip 20 mm wide stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame, welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and as directed. |
| 4 | S&F 75 mm size type C21 butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, complete all as specified and directed. |
| 5 | S&F aluminium handle 100 mm cast type, anodised, complete all as specified and directed. |
| 6 | S&F aluminium anodized tower bolt 100 mm size complete all as specified and directed. |
| 7 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.5 Sqm and not exceeding 4 sqm each, complete all as specified and as directed. |
| 8 | M&L for 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue and pinned at joints, etc., complete all as specified and directed. |
| 9 | S&F 35 mm thick, 2nd class hardwood panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board, medium density wood particle board with commercial face veneers, complete all as specified and as directed. |
| 10 | S&F 30 mm thick 2nd class hardwood glazed and skeleton shutters (partly panelled and partly glazed), open rebated and prepared to receive glass/wire cloth gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. Size of members of shutters as specified in SSR Part I, Section 8, Clause 8.20(a), all as specified and directed. |
| 11 | S&F MS Butt hinges, medium weight, cold rolled mild steel of 100mm size fixed with screws all as specified and directed. |
| 12 | S&F aluminium handle 150 mm cast type anodized all as specified and directed. |
| 13 | S&F aluminium anodized barrel tower bolt 150 mm size complete all as specified and directed. |
| 14 | S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed with screws complete all as specified and directed |
| 15 | S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 16 | S&F in repair galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed . |
| 17 | M&L for preparation of new wooden surfaces of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer, all as specified and directed. |
| 18 | Taking down cement plaster on brick or concrete walls/ ceiling surfaces in patches etc. of any description including racking out joints, hacking for key, scrubbing down with water; rubbish off the premises etc., complete all as specified and as directed. |
| 19 | Material and labour for rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces as in ceilings, finished even and smooth without using extra cement etc complete all as specified and as directed. |
| 20 | Material and labour for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces as on walls, finished even and smooth without using extra cement etc complete all as specified and as directed. |
| 21 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer, all as specified and as directed. |
| 22 | M&L for preparation of newly plastered surfaces of ceilings and applying three coats of white wash, all as specified and as directed. |
| 23 | M&L for Preparation of old plastered or unplastered surfaces of walls including brooming down, steel wire brushing; scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash all as specified and as directed |
| 24 | M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash as in ceiling complete all as specified and directed. |
| 25 | M&L for Preparation of old plastered or unplastered surfaces of walls including brooming down, steel wire brushing; scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots, washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper all as specified and as directed. |
| 26 | M&L for complete removal of existing treatment including preparation of wall surfaces and applying two coats of oil emulsion distemper over a coat of alkali resistant primer all as specified and as directed. |
| 27 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed. |
| 28 | M&L for preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed. |
| 29 | S&F in repair bib tap, standard of PTMT, any colour, high pressure, screwed for iron pipe and fixed, complete all as specified and directed. (Minimum weight: 15 mm - 90 gms / 20 mm - 125 gms). |
| 30 | S&F in repairs 15 mm dia pillar tap, standard of PTMT, any colour, screwed for iron pipe (minimum weight 15 mm - 110 gm), complete all as specified and directed. |
| 31 | S&F in repairs 15 mm dia stop valve of PTMT, any colour, screwed for iron pipe and fixed (minimum weight 15 mm - 90 gm), complete all as specified and directed. |
| 32 | S&F in repairs 15 mm dia angle valve of PTMT, any colour, screwed for iron pipe and fixed (minimum weight 15 mm - 90 gm), complete all as specified and directed. |
| 33 | S&F in repairs swivel shower of PTMT, any colour, for fixing with 15 mm pipe (minimum weight 40 gm), complete all as specified and as directed. |
| 34 | S&F in repair PVC grating 140 mm round PTMT (minimum weight 100 gms) with or without dome, complete all as specified and directed. |
| 35 | S&F 32 mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors all as specified and directed. |
| 36 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm all as specified and as directed. |
| 37 | S&F in repairs PVC flushing cistern, siphonic action type, low level, 10 litre capacity including flush pipe and all accessories, all as specified and as directed. |
| 38 | S&F in repairs for vitreous china wash basin, white, flat back, size 580 x 450 mm, including brackets, cutting for and pinning in ends of brackets, all as specified and as directed. |
| 39 | S&F in repairs 20 mm bore ball cock, high pressure, of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minimum weight 455 gms), all as specified and as directed. |
| 40 | S&F in repairs bib tap, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for union pipe or brass ferrule and fixed to 15 mm dia pipe, all as directed. |
| 41 | S&F in repairs pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with or without lettered hot or cold, with long screwed shanks and fly nuts, screwed for union pipe and fixed to 15 mm dia pipe, all as specified and as directed. |
| 42 | S&F in repairs tubular towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, complete all as specified and directed. |
| 43 | S&F in repairs vitreous china water closet pan (pedestal pattern), white, including fixing bolts, etc., including plastic water closet seat, black/white, closed pattern with flat bottom and cover, and mild steel chromium plated hinging device, all as specified and as directed. |
| 44 | S&F in repairs vitreous china squatting pan of 'Orissa' pattern, size 580 x 440 mm, white, with integral foot rests, complete including trap, set in concrete and provision of lime concrete bedding, all as specified and directed. |
| 45 | S&F in repairs stainless steel sink with drainage board made of 1 mm thick stainless steel, with plug, washer, waste pipe, cast iron cantilever brackets, connecting union to pipe; overall size 915 mm x 460 mm, bowl size 410 x 330 x 160 mm, including bedding in cement mortar to dwarf wall, fixing cantilever brackets and connecting unions to pipe, all as specified and as directed. |
| 46 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes for the tanks of capacity exceeding 250 litres and not exceeding 500 litres and writing date of cleaning in synthetic enamel paint all as specified and as directed. |
| 47 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed. |
| 48 | M&L non-skid light coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors, etc., conforming to IS: 15622:2006, Grade B II (a), matt superior finish flooring, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15 mm thick in CM 1:4 as bedding layer for floor finishes, complete all as specified and as directed. |
| 49 | M&L glazed ceramic coloured tiles size 350 x 250 x 7 mm / 450 x 300 mm / 450 x 350 x 7 mm thick, set as in vertical surfaces such as risers of steps, skirting, dado, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM 1:4, finished even and rough, complete all as specified and directed. |
| 50 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 51 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting, dado etc. set and jointed in neat cement slurry and including 10 mm thick rendering in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 52 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 53 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting, dado etc. set and jointed in neat cement slurry and including 10 mm thick rendering in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 54 | Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc. including making good breakages in taking out and removing from site, all as specified and as directed. |
| 55 | S&F 3 mm thick plain sheet glass, ordinary quality, and glazing with oil putty in squares not exceeding 0.5 sqm in each pane, all as specified and as directed. |
| 56 | S&F 4 mm thick figured glass pin headed type and glazing with oil putty in squares not exc 0.5 sqm in each pane all as specified and as directed. |
| 57 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with bead complete all as specified and directed. |
| 58 | S&F in repair 300 mm MS ordinary rail rod pattern springs including roller and roller plate, complete all as specified and directed. |
| 59 | M&L in repair for 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber framework including teakwood lipping 6 mm thick fixed with nails for cupboard shutters, etc., all as specified and as directed. |
| 60 | M&L for external teak wood lipping, 6mm thick fixed with nails for 19 mm thick Prelaminated particle board faces all as specified and directed. |
| 61 | S&F in repairs particle boards 18/19 mm thick, interior grade, BWR type adhesive, fixed with screws to timber frame in shelves, drawers, etc., all as specified and as directed. |
| 62 | S&F in repair Harrison curtain rails, mild steel, chromium plated, with fixing brackets, stops, rollers, etc., complete all as specified and as directed. |
| 63 | S&F in repair 600 x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood, PVC moulded beading all round, and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed . |
| 64 | Dismantling water tanks of capacity exceeding 500 litres but not exceeding 1000 litres complete all as directed. |
| 65 | S&F 1000 litre capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, all as specified and directed. |
| 66 | S&F ball valves, high pressure, of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of 25 mm bore (minimum weight 455 gms) and fixed complete all as specified and directed. |
| 67 | Dismantling water tanks of capacity exceeding 250 but not exceeding 500 litres, complete all as specified and directed. |
| 68 | S&F 500 litre capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, all as specified and directed. |
| 69 | S&F ball valves, high pressure, of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of 20 mm bore (minimum weight 210 gms) and fixed complete all as specified and directed. |
| 70 | Taking up or down steel tubing and connections, including removal to store, etc., all as directed, for 15 mm bore, all as specified and directed. |
| 71 | All as in above item No. 70.00 but 20 mm bore, all as specified and directed. |
| 72 | All as in above item No. 70.00 but 25 mm bore, all as specified and directed. |
| 73 | S&F Unplasticised PVC pipes and fittings of 15 mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 74 | S&F Unplasticised PVC pipes and fittings of 20 mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 75 | S&F Unplasticised PVC pipes and fittings of 25 mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 76 | M&L for cutting chases or making holes in brick walls for concealed water tubing, making good to facings where required, cutting not exceeding 10 cm girth, all as directed. |
| 77 | Dismantling plain or corrugated steel sheeting of any gauge thickness including Nainital or similar pattern roof covering, all as specified and directed. |
| 78 | Fixing only pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed. |
| 79 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed. |
| 80 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed. |
| 81 | Supply and fix 06 mm thick plain, multicavity polycarbonate sheet (coloured) in roof covering, fixed with self-drilling screws, complete all as specified and as per manufacturer's instructions. |
| 82 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets in ceiling, all as specified and as directed. |
| 83 | S&F false ceiling of non-asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using autoclaving process conforming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid framework of T section (main and cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600 mm x 600 mm. The aluminium framework will be supported on side wall with the use of aluminium 'L' section of size 25 mm x 25 mm x 1.5 mm angles, etc. Snap grid shall be supported with hangers of 4 mm dia galvanised iron wire, adjusting level, fixed to roof slabs/truss, etc. by means of ceiling cleats made out of galvanised iron flat of size 40 x 3 mm, size 60 mm long, and expansion holdfast fasteners 12.5 mm dia x 40 mm long, complete all as specified and directed. |
| 84 | M&L for Green Mexican Grass Lawn: supply, stacking and development of Green Mexican Grass lawn by carrying out the following operations: (a) uprooting vegetation and weeds by digging the area to a depth of 60 cm in any type of soil, removing all weeds, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days and then fine dressing for planting new Mexican grass, including disposal of all rubbish with all leads and lifts. (b) Supply and stacking of approved good quality earth and well composted, dried, well screened natural farmyard manure free of weeds and debris and suitable for horticulture. (c) Developing the area by spreading mixture of approved good earth and farm manure in required proportion in the ratio of 8:1 (08 parts by volume of good quality earth and 01 part by volume of natural farmyard manure). It should be ensured that the soil mixture spreading should not be less than 100 mm above the existing ground level. Approval of Engineer-in-Charge should be obtained towards spreading of garden soil before laying Mexican grass. (d) Providing and laying Mexican grass turf over developed surface of ground prepared with proper level and ramming with wooden tools (Dhumos) and then rolling the surface with light roller and making the surface smooth and lightly watering. A sample of one sqm of turf shall be submitted to the Engineer-in-Charge for approval of GE before the turf is brought into use on site. (e) During maintenance period, watering the lawn daily by providing required pipes and adjustable sprinklers. (f) Weekly weeding, cleaning and removing dry leaves from the lawn. (g) Protection against and control of insects, pests and diseases by spraying fungicides, etc. once in every month. (h) Weeding and mowing of lawn by using mechanical lawn mower with half-capacity collection bags regularly (not exceeding 15 days) to maintain the grass height not exceeding 50 mm from ground level so as not to allow grass to grow wild. Note: The contractor shall be responsible for replacing any grass which fails to survive as a result of inadequate maintenance operations, poor workmanship, poor quality or defective grass during the maintenance period at his own expense. |
| 85 | M&L for 5 mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed. |
| 86 | Demolition of unreinforced cement concrete as in sunken floor of bath, WC and kitchen of any description and in any position not otherwise specifically provided, complete all as directed. |
| 87 | M&L for 15 mm rendering in CM (1:3) with WPC as in sunken floor, finished the surface even and smooth without using extra cement, all as specified and directed. Note: WPC shall be measured and paid separately. |
| 88 | M&L for applying evenly a coat of industrial bitumen 85/25 grade @ 1.2 kg/sqm over a coat of bitumen primer @ 0.30 litre/sqm including cleaning surfaces, etc., complete all as specified and directed including water tightness testing. |
| 89 | M&L plain cement concrete Type F2 1:7:12 ( 40 mm graded aggregate) as in sunken floor filling etc complete all as specified and directed. |
| 90 | M&L for plain cement concrete 25 mm thick type B-1, 1:2:4 (20 mm graded aggregate) as in floor, all as specified and as directed. |
| 91 | Supply only liquid waterproofing compound all as specified and directed. |
| 92 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded aggregate), 100 mm thick as in sub-base to receive floor finishes, etc., complete all as specified and directed. |
| 93 | M&L chequered tiles 20 cm x 20 cm x 25 mm thick set and jointed and pointed in neat cement slurry with grey cement and no pigment in floors over 20 mm thick screed bed in CM 1:4, bedded and jointed in grey cement slurry with pigment, complete all as specified and directed. |
| 94 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), all as all as specified and directed. |
| 95 | M&L for 50 mm thick sand filling and levelling under 60 mm thick interlocking paver block, all as specified and directed. |
| 96 | M&L for machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape and size, conforming to IS 15658-2006, of 60 mm thickness, M-35 Grade, complete all as specified and directed. Please Enable Macros to View BoQ information |