| Sl. No. | Item Description |
| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil |
| 3 | Ordinary Rock . |
| 4 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material All kind soil. |
| 5 | Ordinary Rock |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 7 | Carriage of excated earth by mechinacal transport upto 5kms (upto permissible limits) including loading & unloading |
| 8 | Dumping stone including cost of stones. in Horizontal on level |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs havingslope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : |
| 14 | Centring and shuttering including strutting, propping etc and removal of form work |
| 15 | Walls any thickness including attached buttresses, plinth and string courses etc. |
| 16 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Columns, pillars, piers, abutments, posts and struts. |
| 18 | Suspended floor roof landing etc. |
| 19 | Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete |
| 21 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 22 | Providing & fixing upto floor five level compressed stabilized earth blocks (CEB) made an appropriate mix of dry inorganic subsoil, non-expansive clay, sand, and aggregate with 5% cement as stabilizer, in Cement / mud mortar 1:6, including cost of materials complete. |
| 23 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 24 | Providing and Fixing factory made UPVC door frame, made of UPVC extruded sections , of size 65 mm x 55 mm with wall thickness 2.0 mm ( ± 0.2 mm) ,corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners, all complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class Kail wood |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 27 | Providing and fixing factory made uPVC white colour casement/casement Cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). |
| 28 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-7 mm insulated glass (double glazed) vision panel units of size and shape as required and specified,comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade withreflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear floatglass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal(structural silicone sealant) etc. all complete for the required performances, as per the Architecturaldrawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- Charge.The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 29 | Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorptions <1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTMD 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire rtardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer- in-Charge |
| 30 | 15mm cement plaster on rough side of single or half brick wall in 1:4(1 cement : 4 fine sand mortar) |
| 31 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 32 | 12mm Cement plaster of mix. 13.1.2 1 : 6 ( 1 cement : 6 fine sand) |
| 33 | Providing and applying white cement based wall putty of avg.2mm of approved brand and manifuture |
| 34 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. (Interior Finish) |
| 35 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Two or more coats applied @ 1.25 liter/10Sqm over and including one coat of special primer applied @ 0.75liter /10Sqm |
| 36 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10Sqm) over and including base coat of exterior primer applied @2.20kg/10Sqm |
| 37 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate 40MM |
| 38 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab upto 0.5 Sqm) 18mm |
| 39 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/Sqm mixed with water proofing cement compound@ 0.253 kg/Sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/Sqm mixed with water proofing cement compound @ 0.670 kg./Sqm. and coarse sand @1.289 kg/Sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured. |
| 40 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railingwith necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 41 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 42 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm |
| 43 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/Sqm mixed with with water proofing cement compound @ 0.253kg/ Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 44 | Providing and fixing 12mm thick pre laminated flooring of approved brand as per direction of engineer incharge complete job AC-4 including carriage. |
| 45 | Providing and fixing 12mm thick commercial ply conforming to IS : 1328 BWR type in base for wall panelling |
| 46 | Providing and fixing 100mm pine wood plain lining tongued and grooved, including wooden plugs complete with necessary secrew and priming coat on unexposed surface. 10mm thick |
| 47 | French spirit polishing, Two or more coats on new works including a coat of wood filler |
| 48 | Painting with oil type wood preservative of approved brand and manufacture on New work (two or more coats) |
| 49 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 50 | Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge, complete with; Budloo Wood |
| 51 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 52 | Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on wood |
| 54 | Providing and fixing of bright finished brass hardware fittings 200 mm Handle |
| 55 | 250x10mm Tower bolts |
| 56 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 57 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.103.2 Twin rubber stopper |
| 58 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 59 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Fixed Portion |
| 60 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness |
| 61 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade 1 Type II in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. |
| 62 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Including 1mm thick MS Sheets for sofits and eves boarding. Welded |
| 63 | Providing colour coated Hi-rib profile sheet roofing of approved brand & manufacture, fixed with polymer coated steel screws bolts 100 mm long 8 mm dia with washers & plc. cap (upon a pitch of 60 degrees) excluding the cost of purloins, rafters and trusses (0.50mm thick) |
| 64 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required lengthand of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electrostatically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece |
| 65 | Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats(50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. |
| 66 | Carriage of materials Stone agg. Below 40mm size Avg. 25K.m |
| 67 | Sand Avg. 20K.m |
| 68 | Cement Avg. 20 K.m |
| 69 | Steel Avg. 20 K.m |
| 70 | Stone Avg. 20 K.m |
| 71 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the 25mm OD (SDR-7.4 ) wall etc |
| 72 | 40mm OD(SDR-7.4) |
| 73 | 50 mm OD(SDR-7.4) Ground to roof tanks |
| 74 | External work including trenching, refilling etc. Main supply line. 63 mm OD (SDR-7.4) |
| 75 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 65 mm nominal bore |
| 76 | Providing and fixing ball valve PPR of approved quality completea) 25mm dia OD |
| 77 | b) 40 mm dia |
| 78 | c) 50 mm dia |
| 79 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 80 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer incharge. |
| 81 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P/H.P.H.D plastic balls.25mm nominal bore, 152mm long, weighing not less than440gms. |
| 82 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 83 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 84 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 85 | P/F CP long brass single long swing type lever wall sink mixer of approved quality and make as approved by engineeh-in-charge 15mm dia |
| 86 | P/F CP brass Double lever wall mixer with concealed shower of approved quality and make as approved by engineeh-in-charge 15mm dia |
| 87 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. |
| 88 | Providing and fixing white vitreous china wash Basin with C.I brackets, single hole basin mixer, 32mm CP brass waste of standard pattern , incl. painting of fittings and brackets, cutting and making good the walls where ever required. Wash basin 550x400mm with a pair of 15mm CP brass taps |
| 89 | P/F white vitreous china pedestal for wash basin complete rested at back for the reception of pipe and fittings |
| 90 | Kitchen Sink 610x510x200mm , Incl all fitting CP waste. PVC waste pipe . making PVC connections. |
| 91 | P/F PVC waste 32mm |
| 92 | P/F 8mm dia C.P/S.S jet with flexible tube up to 1mter long with S.S triangular plate to European type W.C of approved quality and make. |
| 93 | P/F 600x450mm bevelled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground glass to wooden cleats with C.P brass screws and washers complete. |
| 94 | P/F 600x120x5mm glass shelf with edges off. Supported on anodised angle frame with CP brass brackets and guard rail complete fixed with 40mm screws, rawl plugs etc. |
| 95 | P/F toilet paper holder (CP) |
| 96 | P/F in position PVC P or S traps |
| 97 | P/F in position PVC floor trapsa) 100mm dia |
| 98 | b) 75mm |
| 99 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External work) .150mm dia |
| 100 | 100mm dia |
| 101 | 65mm dia |
| 102 | 50mm dia |
| 103 | PVC Cowell 50mm dia |
| 104 | P/F PVC stay and clamps for PVC pipesa) 100mm |
| 105 | b) 75mm |
| 106 | c)50mm |
| 107 | P/F bend of required degree with door, inspection rubber washer 3mm thick, bolts and nuts complete PVC S&S pipesa) 100mm |
| 108 | b) 75mm |
| 109 | P/F plain bendsa) 100mm |
| 110 | a) 75 mm |
| 111 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 a) 100mm |
| 112 | b) 75 mm |
| 113 | P/F Tee-junction of required degree with access door, inserted rubber washer 3mm thick, bolts and nuts complete.100x100x100 PVC 1mm a) 100mm |
| 114 | b) 75mm |
| 115 | P/F PVC Reducer 100-50mm dia |
| 116 | Providing and fixing liquid PTMT soap container 109mm wide 125mm high and of approved quality weighing not less than 105 grms |
| 117 | P/F PTMT towel rails with brackets fixed to wooden cleats with CP brass with concealed fittings arrangement of approved quality (600mm long total length 645mm ,`78mm wide and effective hight 88mm weighing not less than 190gms |
| 118 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 119 | Providing and fixing uplasticized PVC connection pipe with brass unions. 45 cm long |
| 120 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominalsize),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line- |
| 121 | P/F master trap |
| 122 | Providing and fixing 5 H.P C.G Motar, including all fitting 2no ball value, non return value vertical/ horizontal, shelter, base, electric pannel switch board with DP MCB 20amph |
| 123 | Providing and fixing of material for the insulation of water storage tank of with nitrile sheet taping with cello tape, rockwool 6 inch per side, wire mesh, polythene, alluminium sheet 26 gage cladding with dia of, complete job 19mm thick nitrile sheet. |
| 124 | Providing and Fixing of heat tape 33 watt on PPR Pipes made of denforced or Chromelox or equalent make as per approved by engineer incharge complete job. |
| 125 | Providing and fixing Urinal basin with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. |
| 126 | Providing and fixing of material for the insulation of pipe with netrile tube, tapping with cello tape for inner walls fitting complete job including carriage 19mm thick, 50mm dia (OD) (PPR 25mm) |
| 127 | Providing and fixing of material for the insulation of Pipe with nitrile tube taping with cello tape, rockwool 6 inch per side, wire mesh, polythene, alluminium sheet 26 gage cladding with dia of, complete job 19mm thick, 50mm dia (OD)(PPR 40MM) |
| 128 | 19mm thick, 50mm dia (OD)(PPR 50MM) |
| 129 | Providing and fixing Gysers (Venus, Recold)a) 50 Litre for Wash Room |
| 130 | b) 35 Litre for Kitchen |
| 131 | Main LT PanelSupply, installation, testing and commissioning ofLT. cubicle type totally enclosed In door, double door type, free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB & MCB's complete as required.INCOMER:2 nos.250A 4P microprocessor based MCCB of 36kA with Rotary Handle, shunt trip coil, adjustable O/L, S/C, E/F release. (Main MCCB to Servo and Servo to ATS)1 no. 250A 4P Auto Transfer Switch 2 nos. Digital type multifunction meter with following parametersDigital multifunctional meter 1 set of CT's of 200/5 Amp.2 Set of R,Y,B LED phase indicating lamp with MCB protection.2 Set of ON,OFF & TRIP LED indicating lamp with MCB protection.BUSBARS:400 Amp & 200 Amp TPN (25kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium OUTGOING:2 nos. 160A 4P thermal magnetic based MCCB of 25kA with Rotary Handle.6 nos. 125A 4P thermal magnetic based MCCB of 25kA with Rotary Handle. 4nos. 63A MCB DP C curveMLTP PANEL described above and specifications complete. |
| 132 | Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade.i/c excavtion, backfill, clamping as required185 sqmm 3.5 core |
| 133 | Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 3½ X 185 sq. mm (35mm) |
| 134 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 135 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 136 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB (UPS I/P) |
| 137 | Supplying, fixing of MCCB MS door type Enclosure suitable for 100 - 160 Amp 4 P MCCB |
| 138 | Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 139 | Double pole |
| 140 | triple pole |
| 141 | Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. {With enclosure (at AC points Power supply)} Double pole |
| 142 | Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40-63 A |
| 143 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way , Double door |
| 144 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door |
| 145 | Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 146 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 147 | 2 x 4 sq.mm + 1 x 4 sq.mm earth wire |
| 148 | 2 x 6 sq.mm + 1 x 6 sq.mm earth wire |
| 149 | 2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring |
| 150 | 4 x 6 sq.mm + 2 x 6 sq.mm earth wire for Sub main wiring |
| 151 | 4 x 10 sq.mm + 2 x 10 sq.mm earth wire for Sub main wiring |
| 152 | 4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring |
| 153 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 154 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 155 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(with Anti bacteria series) 4 Module (125mmX75mm)(230 Volt out lets) |
| 156 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(with Anti bacterial Switches/ sockets)(heating) 15/16 A switch |
| 157 | 3 pin 5/6 A socket outlet |
| 158 | Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular Switch, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects (with Anti bacterial Switches/ sockets)note: all items included like Conduit, wire, MS box, switches etc. |
| 159 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (with Anti bacterial Switches/ sockets)note: all items included like Conduit, wire, box, switches etc |
| 160 | Providing and fixing of UPS power pointpower point (in loop .) with 1.5 sq. mm PVC insulated copper wire , through midium classPVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 2 nos. recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 1.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned (with Anti bacterial Switches/ sockets)note: all items included like Conduit, wire, box, switches etc. |
| 161 | Installation, testing and commissioning of pre-wired, (LED) fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 162 | Supply of 4 ft LED slim 40 watt 125lm/w 230V Batten Aluminium body type lights(T5 Type) , complete in all respects. 110 LM/W LM79-80, L70, 2.5 KV Surge Protection (with five years OEM warrenty) Wipro/ Philips/ LT |
| 163 | Supply ofof 12 watt surface LED type slim 230V , complete in all respects commertial type120 LM/W LM79-80, L70, 2.5KV Surge Protection (with five years OEM warrenty) Wipro/ Philips/ LT |
| 164 | Supply ofof 18 watt surface LED type slim 230V , complete in all respects commertial type120 LM/W LM79-80, L70, 2.5KV Surge Protection (with five years OEM warrenty) Wipro/ Philips/ LT |
| 165 | Supply o f36 watt surface mount LED type slim 230V , complete in all respects commertial type .120 LM/W LM79-80, L70, 2.5KV Surge Protection (with five years OEM warrenty) Wipro/ Philips/ LT |
| 166 | Supply & fixing of 100 Watt Flood light LED type slim 230V , complete in all respects commertial type 110 LM/W LM79-80, L70, 2KV Surge Protection |
| 167 | Supply of 2 ft LED slim 20 watt 100lm/w 230V Batten type lights(T5 Type) , complete in all respects. 100 LM/W. |
| 168 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 169 | Suppyly, testing of 12”x12” flap window type exhaust fan complete with all accessories. etc . |
| 170 | Suppyly,fixing, testing of 380mm 240V, 150 Watts dia. Industrial duty metalic type exhaust fan incl. Grill safety complete with all accessories. etc . (kitchen area) |
| 171 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 172 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) (with Anti bacteria series) |
| 173 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections and modular plate etc. as required.(with Anti bacterial Switches/ sockets)TV antenna socket outlet |
| 174 | 5/6 A switch |
| 175 | 3 pin 5/6 A socket outlet |
| 176 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) (TV/tel) |
| 177 | 4 Module (125mmX75mm) |
| 178 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (UTP CAT 6 and Telephone lines) 20 mm |
| 179 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 180 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in heavy duty PVC conduit (conduit included) as required.1 run of cable |
| 181 | Supply and installation of flush mounted Enhanced Category 6 outlet. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover / blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover shall be provided to protect jack wiring. D-link Single outlet faceplate with RJ-45 jack |
| 182 | Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged & lockable door including supply & fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 20Pair |
| 183 | Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged & lockable door including supply & fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 20Pair |
| 184 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 185 | Supply, installation, testing & commissioning of advance maintenance free Chemical Gel Earthing of Single Pipe Technology (GI) of 3mtrs length 60-63 mm dia CHEMRODE filled with highly conducting metallic compounds with the permanent sealings at the both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connected the strip/wire to the load. including the weather proof chamber |
| 186 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 187 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 188 | sypplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels / |
| 189 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 190 | supplying , fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) |
| 191 | Supply, installation, testing and commissioning of main control M.V. cubicle type totally enclosed, double door, out door type standing type (stand height 1 meter), dust, damp and vermin proof M.V. danger notice plate, connection of incoming and out going cables with thimbles, stove enameled painted and having following incoming/ outgoing MCCB , meters, indicators and bus bar arrangements complete as required including bottom concreated etc in all respects as per site requirements.wwith:-a) 1 no. 80 Amp MCCB 25 KA TPNb) 1 set 100 Amp busbar 4 strip heavy duty aluminum basbar.c) 0-500volt volt meter (digital)d) selector switches.e)4no x 32 Amp DP C- curve MCB 240 /415 V, 10 kA, “C”-curve, MCB. f) 1 no.16 Amp SS combineg) Panel light with door switch arrangements. h) 1 no Astronomical Timmer with 3 P 40 Amp Contactors |
| 192 | Providing errecting Fixing of 7 meter octaganal hot dipped galvanizes 3mm thick poles with in built MCB arrangements with base template drilled plates/ top cap, Anchoring bolts of standard size etc the pole should have two arm arrangements at different levels (at 5 meter and 7 meter). and should beerrected on proper( Steel Rainforced) RCC base foundation not less than 0.75CUM in RCC (including) and should be provided with 1.5 inch HDPE conduits IN and OUT . as per site requirement complete. |
| 193 | Providing, fixing of GI cross Arms suitable for 120 watt cool out door luminaries |
| 194 | Providing, fixing of GI cross Arms suitable for 70 watt warm out door luminaries |
| 195 | Wiring for lighting out side throgh GI poles circuit submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, two core cables 2 core 1.5 sq. mm |
| 196 | Supply , fixing of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 35 sqmm 3 1/2 core |
| 197 | 16 sqmm 2 core |
| 198 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 35 sq mm to 95 sqmm |
| 199 | up to 35 sqmm |
| 200 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 201 | Supplying and fixing 3A A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 202 | Supplying and fixing 32 Amp 4p connectors in the in built MCB Segment of the GI pole complete in all respects |
| 203 | Supplying,Fixing, Testing and Commissioning of outdoor LED street light luminaries IP 66 (Arm type) 120 Watt. Havells, Wipro, LT, Philps |
| 204 | Supplying,Fixing, Testing and Commissioning of outdoor LED street light luminaries IP 66 (Arm type)70 Watt. Watt. Havells, Wipro, LT, Philps |
| 205 | Providing, fixing, testing and commissioning of Complete LT switch gear unit consisting of 400 Amp. MCCB TPN 50KA ADJUSTABLE, with 630 A busbar 3-phase of good quality make as per approval of engineering wing, housed properly in cubical MS Painted SWG-16 (double door and outdoor type). Including cost of concreting/ Bottoming/finishing as required. (sevo Input) |
| 206 | Supply, Installation, Testing and Commissioning of 125 KVA Servo Voltage Stabilizer Linear type out-door type with fresh dehydrated oil.3 Phase Servo Stabilizer: Un-Balanced 4 wire system(Linear type un-balanced Transformer), Method of Cooling : ONAN, Phase : 3 Phase, 4 wire, Frequency : 50 Hz Input Voltage : (P-P) 270-470 (P-P), Output Voltage : 415 V +-1%, Efficiency : 98% + at full loadControls : Auto/Manual Selector Switch, Increase Decrease Toggle Switch for Manual Operation, Output SwitchSystem construction : As per IS 9815 /IS2026Independent Phase Control : Maintain each phase voltage stable irrespective of unbalanced loadTransformer Winding : Copper 99.9% Pure, Duty Cycle : 100%, Container: 14 SWG with Stove enamelled paint, Cable Box and Busses : BAR suitable size of cable box with 6 aluminium busbars (3+1 for input, 3+1 for output ), Oil capacity : As requiredPaint : Powder Coated, Color : RAL 7035 (Polyester Powder Coating)System Construction : AS per IS-9815 with minimum two OEM years warrenty period. |
| 207 | FoundationConstruction of Foundation for125 KVA servo transformer (as required at site) of 600mm high and 600mm deep below ground level, size (1500mmx1500mm) with roofin in CGI sheets along with supports etc in all respects . Excavating/ steel bars/ Reinforced cement concrete work in well-staining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse Sand (zone-III): 3 graded stone aggregate 20 mm nominal size). and including top selter roofing in CGI sheets with suitable 6mm/35mm angle iron As required as per site, complete in all respects. |
| 208 | sypplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels / |
| 209 | supplying , fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sqM) |
| 210 | First Aid Kit as per Red Cross Standards, complete with Medicines for Burns, Cut Vomiting , Swelling , Cotton Wool, Cotton Bandage , Surgical Sprit etc placed in a wall mounting box with 6mm thick front hinged glass cover, with the sign \\" +\\" and the inscription \\"FIRST AID\\" in Red Paint - Overall size not less than 450mm x 300mm x 200mm deep in two tier shelf pattern. |
| 211 | Supply, installation, testing & commissioning of 3 kVA 1 phase Inverter with 3x200AH 12V tubuler Batteries including suitable rack, input/output leads/ Switch sockets etc. to make the system operational.Note: Item Should have minimum of two years Warrenty and free service. |
| 212 | Providing and fixing modular PVC Modulebox with 32 A MCB and 6 pin 32 A socket outlet combine of reputed make/ as per approval (INV i/p &o/p) |
| 213 | Providing and fixing 63 MCB type Change over switch with Enclosure |
| 214 | Supplying, Installation Testing & Commissioning of ISI marked CO2 gas type Fire Extinguisher of 4.5 kg capacity conforming to IS: 15683:2018 made from Seamless Cylinder conforming to IS 7285, fitted with ISI marked Control Valve Conforming to IS:3224 discharge adopter complete with initial gas charged with carrying handle and wall mounting bracket etc. as reqd. |
| 215 | Supplying, installation, testing and commissioning of ISI marked ABC stored pressure type fire extinguisher of 6 kg capacity consisting of welded cylinder, squeeze lever discharge valve fitting with pressure indicating gauge with internal discharge tube, discharge nozzle, suspension bracket conforming to IS:15683:2018 duly charged, with ISI marked mono Ammonium Phosphate base ABC powder conforming to IS:4308 and pressurized with nitrogen gas etc. as required. |
| 216 | Supplying & fixing of fire extinguisher/refills as per IS specification 4 buckets set with sand, self-supported M.S. stand i/c shed duly painted with redcolour as per IS. |
| 217 | Supplying & fixing of 25 Kg Trolley ABC Type Fire Extinguisher, wheeled duly painted with redcolour as per IS. |
| 218 | 4 buckets set with sand, self-supported M.S. stand i/c shed duly painted with redcolour as per IS. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail