| 1 | Taking down carefully unserviceable point wiring of any description/ type/ size of light/ fan / tube/ power / two way/ bell etc. on TW batten/ conduit/casing caping including removal of batten/ conduit/ casing caping/ gutties/ wooden boards/ switches/ sockets/ regulators/ holders/ ceiling roses/ call bells/ etc and making good the disturbed surfaces of wall/ ceiling so as to match with the existing finishes complete all as directed. |
| 2 | M&L for point wiring with PVC insulated and PVC unsheathed single core multistranded FRLSH copper conductor cable of size 1.5 Sqmm (nominal area) using approved colour coding, 1100 volts grade, ISI marked, including PVC conduit heavy grade, 20 mm or higher dia with fittings concealed in wall/ on surface for ceiling with continuous earth wire of PVC insulated and PVC unsheathed single core multistranded FRLSH copper conductor cable of size 1.5 Sqmm (nominal area) 1100 volts grade, ISI marked and connecting to the common earth dolly including provn of 3mm thick plastic laminated sheet of appropriate size and sunken CI/ pressed steel terminal boxes for mounting switches, sockets and regulators etc including cutting chases and making good to the disturbed surfaces as per existing specifications for One light point/fan point/ bell point controlled by one, one way switch complete all as specified and directed. |
| 3 | All as per Srl item No 2 here-in-before but in existing PVC conduit. |
| 4 | All as per Srl item No 2 here-in-before but for one 5 pin socket outlet 5 Amp on independent board |
| 5 | All as per Srl item No 4 here-in-before but in existing PVC conduit. |
| 6 | All as per item Srl No 2 here-in-before but for one 5 pin socket outlet, 5 amps on the same board with other switch. |
| 7 | All as per Srl item No 2 here-in-before but for one light point controlled by two, 2 way switches. |
| 8 | All as per serial item No. 02 here-in-before but with PVC insulated and PVC sheathed single core multistranded FRLSH copper conductor cable of size 2.5 Sqmm (nominal area), using approved colour coding, 1100 Volt grade ISI marked including PVC insulated and PVC sheathed single core multistranded FRLSH copper conductor cable of size 2.5 Sqmm (nominal area) 1100 Volt grade ISI marked as earth continuity conductor and connecting to the common earth dolly for 3 pin 15/16 Amps socket outlet on independent board. |
| 9 | All as per item Srl No 8.00 here-in-before but in existing PVC conduit. |
| 10 | M&L for point wiring with PVC insulated and PVC unsheathed single core multistranded FRLSH copper conductor cable of size 1.5 Sqmm (nominal area) using approved colour coding, 1100 volts grade, ISI marked, including PVC conduit heavy grade, 20 mm or higher dia with fittings concealed in wall/ on surface for ceiling with continuous earth wire of PVC insulated and PVC unsheathed single core multistranded FRLSH copper conductor cable of size 1.5 Sqmm (nominal area) 1100 volts grade, ISI marked and connecting to the common earth dolly including sunken factory made 16 SWG thick pressed steel terminal box of suitable size covered with and including modular white cover plate with inner frame suitable for housing modular switches, sockets, regulators etc including cutting chases and making good to the disturbed surfaces as per existing for One light point/ fan point/ bell point controlled by one, one way switchy complete all as specified and directed. |
| 11 | All as per Srl item No 10 here-in-before but in existing PVC conduit. |
| 12 | All as per Srl item No 10 here-in-before but for one 5 pin socket outlet 5 Amp on independent board |
| 13 | All as per Srl item No 12 here-in-before but in existing PVC conduit. |
| 14 | All as per item Srl No 10 here-in-before but for one 5 pin socket outlet, 5 amps on the same board with other switch. |
| 15 | All as per serial item No. 10 here-in-before but with PVC insulated and PVC sheathed single core multistranded FRLSH copper conductor cable of size 2.5 Sqmm (nominal area), using approved colour coding, 1100 Volt grade ISI marked including PVC insulated and PVC sheathed single core multistranded FRLSH copper conductor cable of size 2.5 Sqmm (nominal area) 1100 Volt grade ISI marked as earth continuity conductor and connecting to the common earth dolly for 3 pin 15/16 Amps socket outlet on independent board. |
| 16 | All as per item Srl No 15.00 here-in-before but in existing PVC conduit. |
| 17 | M&L for sub main wiring with two runs of single core multi stranded PVC insulated, copper conductor, grade 1100 Volt , FRLSH cable of size 6 sqmm including 6 sqmm multistranded copper conductor FRLSH cable PVC insulated for earthing duly connected with earth dolly, with approved colour coding including PVC conduit heavy grade of appropriate dia concealed in wall with accessories including cutting chases and making good to the disturbed surfaces as per existing and taking down old unserviceable wiring complete all as specified and directed. (Note :- Three run of cable alongwith PVC conduit together shall be measured as One RM). |
| 18 | M&L for sub main wiring with two runs of single core multi stranded PVC insulated, copper conductor, grade 1100 Volt , FRLSH cable of size 4 sqmm including 4 sqmm multistranded copper conductor FRLSH cable PVC insulated for earthing duly connected with earth dolly, with approved colour coding including PVC conduit heavy grade of appropriate dia concealed in wall with accessories including cutting chases and making good to the disturbed surfaces as per existing and taking down old unserviceable wiring complete all as specified and directed. (Note :- Three run of cable alongwith PVC conduit together shall be measured as One RM). |
| 19 | S&F switch piano flush type single pole one way 6 amps all as specified and directed. |
| 20 | S&F socket outlet 3 pin 6 amp flush type all as specified and directed. |
| 21 | S&F switch piano flush type 16 Amp single pole one way all as specified and directed. |
| 22 | S&F socket outlet 3 pin 16 amp flush type all as specified and directed. |
| 23 | S&F bell push flush type single pole one way, 6 Amp all as specified and directed. |
| 24 | S&F electric bell Ding Dong type 230V, 50Hz all as specified and directed. |
| 25 | M&L for switch piano flush type singel pole, 2 way, 5/6 Amps, 240V complete all as specified and directed. |
| 26 | S&F in replacement of fan regulator electronic 5 step type and connecting all as specified and directed. |
| 27 | S&F modular switch 1 way, 1 module 6 amps single pole one way all as specified and directed. |
| 28 | S&F modular socket, 2 module 6A 2/3 pin all as specified and directed. |
| 29 | S&F modular switch 1 way, 16 amps, 1 module all as specified and directed. |
| 30 | S&F modular socket, 6A/ 16A -2/3 pin combined, 2 module all as specified and directed. |
| 31 | S&F modular fan regulator 2 module electronic 5 step type, 120W all as specified and directed. |
| 32 | S&F modular bell push flush type single pole one way, 6 amp all as specified and directed. |
| 33 | S&F surface mounting universal box type housing made of powder coated CRCA sheet suitable for upto 1 x 18/20 W LED tube including taking down existing old unserviceable housing complete all as specified and as directed. |
| 34 | S&F in repair LED tube 18/20W ultra bright LED polycarbonate tube with efficacy minimum 2000 lumens, CCT > 6500K, PF > 0.90 suitable for fitting into exsting/ new batten housing and connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor wire of size 0.75 sqmm 3 core and taking down existing old unserviceable tube complete all as specified and directed. (Note :- The contractor shall submit the LM-80 and LM-79 report form manufacturer to Engineer-in-Charge for approval before incorporating the items in work). |
| 35 | S&F in repair LED light fitting mirror type with high out put diffuser 2 feed, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 36 | S&F in repair decorative 9W LED wall mounting fittings complete set including 9W LED lamp complete all as specified and directed. |
| 37 | S&F in repair of LED bulk head light fitting 1 x9/10 watt cool daylight (CDL) round type premium quality diffuser for even distribution of light complete, connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75Sqmm all as required. |
| 38 | S&F in repair LED light fitting 1x20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone-1 & 2 abd IP65 protection with die cast aluminium hosing with heat resistant toughered glass with LED tybe light fixtures driver, holders, connector etc complete with all accessories prewireed and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed. |
| 39 | S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 40 | S&F in repair octane 24 watt 4000k LED Panel slim compact aluminium die cast edge lit panel recess mounted square fixture with opal diffuser and separate electronic drive, ceiling cut out 284mmx284mm all as specified and directed. |
| 41 | S&F in repair indoor type decorative recess mounted direct/indrect 60cm x 60cm luminaries light fixures 36 watt LED netural white complete including making connection with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 42 | S&F in-built PIR sensor (36 Watt LED, Size 2x2 feet) indoor type decorative recess mounted direct/ indirect luminaries light fixures (white) indoor type decorative recess mounted direct/ indirect luminaries light fixures (white/ warm white as per ground requirement) aluminium body, opal diffuser, IP20, suitable for false ceiling complete including making connection with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 43 | S&F in repair tube light fitting LED 20W inverter batten type fitting 4 feet long aluminium housing, charging time 10-12 hours with 4 hours backup IP20, rated volatge 230 V, 50Hz system of wattage 20W (+/- 10%), current less than 1.2 mA, power factor more than 0.95 and system lumen efficeincy of 100 lm/watt, CCT > 6500 K, CRI > 80, THD < 30%, driver efficeincy more than 85% complete with all accessories prewired and connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor wire of size 0.75 sqmm 3 core all as required at site including taking down existing old unserviceable fitting. (Note :- The contractor shall submit the LM-80 and LM-79 report form manufacturer to Engineer-in-Charge for approval before incorporating the items in work). |
| 44 | S&F lamp holder with LED retrofit lamp 9 watt suitable for lamp holder base all as specified and directed. |
| 45 | S&F modular lamp holder with LED retrofit lamp 9 watt suitable for lamp holder base all as specified and directed. |
| 46 | S&F ceiling rose, 3 terminals/ phase/ PVC/ polycarbonate, isolated body. |
| 47 | S&F boxes junctions, plastic, round, four terminals all as specified and directed. |
| 48 | Taking out existing old unserviceable distribution box / sheet metal enclosure off size and making good disturbed surfaces as per existing specifications complete. |
| 49 | M&L for distribution board made out of CRCA sheet DB vertical type double door TPN 4 way including fixing in the wall, cutting chases, grounting and making good to match with the existing including making connections all as directed containing the folowings:- (a) MCCB 4 Pole 100 Amps 16 KA breaking capacity with thermal release: 01 No (In coming). (b) Bus bar factory made made out of aluminium duly insulated with wire adhesive tape RYB & black :4 Nos. (c) MCB SPN 40 Amp: 4 Nos, MCB SP 10-32 Amp: 08 Nos (Out going). (d) Connection from MCCB to bus bar will be made with aluminium strip of suitable capacity as directed. |
| 50 | S&F in repair sheet metal enclosure for DB’s when MCB’s to be used, 240 volt 8 way SPN with bus bar and double door complete all as specified and directed. |
| 51 | S&F in repair MCB single pole 6 amps to 32 amps complete all as specified and directed. |
| 52 | S&F in repair MCB single pole and neutral 20 to 32 amps complete all as specified and directed. |
| 53 | M&L for earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground vertically to a depth not less than 2.25 metres deep below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common saft filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron light grade pipe 15mm bore in wall/ floor/ and GI pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning filling with approved soil and disposed of surplus soil to a distance not exc 50 mtr away complete all as shown in electrical plate No 3 of SSR 2020 (Part-I). |
| 54 | S&F GI pipe bracket made out of GI pipe light grade 32 mm bore and bent to shape 1.5m long, MS clamps made out of MS flat iron of size 40mm x 5mm and drilling of hole for and including nuts, bolts and washers, painting MS clamps with two coats of synthetic enemal paint over a coat of red oxide primer including taking down the existing GI pipe bracket complete all as specified and directed. |
| 55 | S&F LED security light fitting 45 Watt output, warm white CCT > 3000K with IP 66 protection suitable upto 50mm OD holder on existing wall/ bulilding/poles, LED light fitting shall be made up of pressure die cast aluminium LM 6 alloy with toughend glass, high power LEDs with efficiency minimum 4500 lumens and secondary lenses with brand name embossed on cover. High power ceramic base, CRI >70, Surge protection of min 5 KV with driver including taking down existing old unserviceable fitting complete. Note:- (i) Luminaries and driver shall be of same make as of main light fitting. |
| 56 | S&F in repair 10 sqmm twin core cable flat or circular, 1100 volts grade heavy duty cable PVC insulated aluminium conductor stranded, served with inner sheathing of PVC tape and overall PVC sheathed in service connections. |
| 57 | S&F in repair 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape and over all PVC sheathed in service connections, one twin core 6 sqmm cable standard conductor cable flat or circular complete al as specified and directed by Engineer-in-Charge. |
| 58 | S&F in repair remote control unit suitabe for fan and light mechanism with remote, 4 module including metal sunken box and plate complete all as specified and directed. |
| 59 | S&F electronic dimmers, 450W, 250V flush type on the existing phenolic laminated sheet etc all as specified and directed. |
| 60 | S&F in repair building security light 45W, motion sensor street light, energy efficient should stays on as long as motion is detected, then dims to 20% if no movement is detected for 90 seconds, inbuilt microwave sensor, suitable for indoors/ outdoors with high efficient high power LED enclosed with toughened glass and voltage rated 220V to 240V etc complete all as specified and directed. |
| 61 | S&F MCCB 3 Pole , 415V fixed type, 25 to 100 amps with breaking capacity 16 KA all as specified and directed. |
| 62 | S&F MCCB 415V, 16KA, 4 Pole 63 Amps all as specified and directed. |
| 63 | S&F in repair 1 module PVC box with top, bottom, side back wall knockout for conduit entry from any direction complete all as specified and directed. |
| 64 | S&F in repair 2 module PVC box with top, bottom, side back wall knockout for conduit entry from any direction complete all as specified and directed. |
| 65 | S&F in repair 3 module PVC box with top, bottom, side back wall knockout for conduit entry from any direction complete all as specified and directed. |
| 66 | S&F in repair 4 module PVC box with top, bottom, side back wall knockout for conduit entry from any direction complete all as specified and directed. |
| 67 | S&F in repair 6 module PVC box with top, bottom, side back wall knockout for conduit entry from any direction complete all as specified and directed. |
| 68 | S&F in repair 12 module PVC box with top, bottom, side back wall knockout for conduit entry from any direction complete all as specified and directed. |
| 69 | S&F in repair sleek and curve plate with elegant looks comes with sturdy support frame for solid strength of 1 module all as specified and directed. |
| 70 | S&F in repair sleek and curve plate with elegant looks comes with sturdy support frame for solid strength of 2 module all as specified and directed. |
| 71 | S&F in repair sleek and curve plate with elegant looks comes with sturdy support frame for solid strength of 3 module all as specified and directed. |
| 72 | S&F in repair sleek and curve plate with elegant looks comes with sturdy support frame for solid strength of 4 module all as specified and directed. |
| 73 | S&F in repair sleek and curve plate with elegant looks comes with sturdy support frame for solid strength of 6 module all as specified and directed. |
| 74 | S&F in repair sleek and curve plate with elegant looks comes with sturdy support frame for solid strength of 12 module all as specified and directed. |
| 75 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Rs. 1,56,720/- Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. Please Enable Macros to View BoQ information |