| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and removing rubbish out of the MD land complete all as specified |
| 2 | M&L Anti-Skid / Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes. complete all as directed.(Note- Make- Jhonsan, Kajaria, Somany, AGL Tiles) |
| 3 | M&L Glazed Ceramic Coloured Tiles 6 to 7mm thick on Vertical Surfaces such as Dados, Skirting on wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match on vertical surfaces including Rendering 10 mm thick in CM (1:4) finished rough to receive wall tiles. (Note- Make- Jhonsan, Kajaria, Somany, AGL Tiles) |
| 4 | M&L for Coloured Virified Ceramic Tiles 9 to10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.72 sqm, in Floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. including 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying Floor Finishes.(Note- Make- Jhonsan, Kajaria, Somany, AGL Tiles) |
| 5 | M&L for Coloured Vetrified Ceramic Tiles 9 to 10 mm thick in Skirting / Dado including 10mm thick backing coat in CM (1:4) complete all as specified and directed.(Note- Make- Jhonsan, Kajaria, Somany, AGL Tiles) |
| 6 | M&L Cement Concrete type B-1, 1:2:4 ( 20mm graded aggregate) 25mm thick rough finished as in sub base wiithout using extra cement for leveling of Floor. |
| 7 | Dismantling Stone slabs and tiles laid dry and pointed of any description or thickness in floors, aprons etc and removing rubbish out of the MD land complete all as specified |
| 8 | M&L for Granite 18 to 20mm thick table rubbed and polished as in Floor, Steps, Jambs, Pillars, Window Cills, Cooking Platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixure of pigment to match with granite slab including Edges Rounded and Polished complete all as specified and as directed by the Engineer in Charge |
| 9 | Demolition of Brick Work or Stone Masonry built in Cement Mortar including pillar etc. complete all as apecified |
| 10 | M&L for Brickwork with Fly Ash Modular Bricks straight or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified |
| 11 | Taking down plastering in cement mortar on brick or stone wall/ ceilings etc including racking out joints hacking for key scrubbing down with water etc and removing rubbish out of the MD land complete all as specified and directed. |
| 12 | M&L for Rendering 10mm thick in CM 1:4, finishing even and smooth without using with out extra cement on Internal Surface of Wall and all as specified and directed |
| 13 | M&L for Rendering 15mm thick in Two Coat 10 mm thick in CM 1:6 and 5mm thick in CM 1:4 mixed with Integral Water Proofing Compound as per manufacturer instruction, on fair faces of Brick Work or Concrete Surfaces finish even and smooth without using extra cement on External Wall all as specified and as directed ( Water Proofing Compound to be measured and paid separately) |
| 14 | M&L for Rendering 5mm thick in CM 1:3 finishing even and smooth without using extra cement on Ceiling and all as specified and directed |
| 15 | M&L for Applying Two Coats of OBD over One Coat of 3mm thick Wall Care Putty over a Coat of Alkali Resistant Primer including preparing the New Plastered Wall Surfaces complete all as directed (Note- All paint strains on floor/wall/furniture/glass/joinery etc to be removed and cleaned to the satisfactory of Engr-in-charge). |
| 16 | M&L for Applying Two Coats of OBD over One Coat of 3mm thick Wall Care Putty, over a Coat of Alkali Resistent Primer and Preparing the New plastered Ceiling Surfaces complete all as specified and directed. (Note- All paint strains on floor/wall/furniture/glass/joinery etc to be removed and cleaned to the satisfactory of Engr-in-charge). |
| 17 | Material & Labour for Finishing Walls with Approved Textured and Applying Two or More coats of 100% Premium Acrylic Emulsion Paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance Exterior Paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including Priming Coat of Exterior Primer applied @ 0.90 litre/ 10sqm over New Plastered Surfaces complete all as specified and directed. (Note- All paint strains on floor/wall/furniture/glass/joinery etc to be removed and cleaned to the satisfactory of Engr-in-charge. (Make- Asian paints (Apex ultima) or equivalent). |
| 18 | M&L for Complete Removal of Existing Treatment on Wall Surfaces and Applying Two Coats of Oil Bound Distemper over One Coat of 3mm thick Wall Care Putty over a Coat of Alkali Resisitant Primer including filling all Cracks with Crack Filling Material complete all as specified and directed. (Note- All paint strains on floor/wall/furniture/glass/joinery etc to be removed and cleaned to the satisfactory of Engr-in-charge). |
| 19 | M&L for Complete Removal of Existing Treatment on Ceilling Surfaces and Applying Two Coats of Oil Bound Distemper over One Coat of 3mm thick Wall Care Putty over a Coat of Alkali Resisitant Primer including filling all Cracks with Crack Filling Material complete all as specified and directed. (Note- All paint strains on floor/wall/furniture/glass/joinery etc to be removed and cleaned to the satisfactory of Engr-in-charge). |
| 20 | M & L for Preparation of Old Surfaces by Complete Removal of Existing Treatment of Painted Wall / Ceiling incl Pillar etc. by Mechanical equipments like Electric Wall Sander / Water Jet Machine Finishing Walls with Approved Textured and Applying Two or More Coats of 100% Premium Acrylic Emulsion (weather proof) Paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance Exterior Paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including Priming Coat of Exterior Primer applied @ 0.90 litre/ 10 sqm over Wall / Ceiling Surfaces including opening all cracks and filling the cracks with Crack Filling Material complete, by Mechanical Means as per manufacturer's specification all as specified and as directed by GE. (Note- All paint strains on floor/wall/furniture/glass/joinery etc to be removed and cleaned to the satisfactory of Engr-in-charge). (Make- Asian paints (Apex ultima) or equivalent). |
| 21 | Demolition of cement concrete ( unreinforced) in ground floors and pavings n.exc 15 cm thick, including removing rubbish out of the MD land complete all as specified complete all as specified |
| 22 | M&L for PCC (1:3:6) type C2 using 40mm graded aggregate as Plinth Protection / Paths of 75mm thick finishing cement concrete surface even and smooth without using extra cement complete as specified |
| 23 | M&L for 50mm thick M-Sand cushing for laying of Precast Concrete Interlocking Tiles including watering and consolidation complete. |
| 24 | M & L for 60mm thick, M 35 grade Machine Pressed Precast Concrete Interlocking Paver Block rubber mould using grey cement and pigment of any shape and size conforming to IS 15658 - 2006 all as specified and ditected. |
| 25 | Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as apecified |
| 26 | Taking down chowkats or frames with shutters (without taking off shutter from the frames ) exceeding 1.5 Sqm each but n.exc. 4 sqm each complete all as apecified |
| 27 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 28 | Supply and fixing to door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant gradeunsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge |
| 29 | S&F 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified |
| 30 | S&F 150mm size aluminium anodised handles, fabricated type complete all as specified |
| 31 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified |
| 32 | S&F 150 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy and all as directed |
| 33 | S&F Pressed Steel Frames for Doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc of size 125 x 60 mm complete all as specified |
| 34 | S&F Pressed Steel Frames for Doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc of size 105 x 60 mm complete all as specified |
| 35 | S&F Mild Steel flats 25x3 as in Hold Fastsand all as directed |
| 36 | M&L PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in filling in frame complete all as specifed and directed. |
| 37 | M&L for 35mm thick Flush Shutter, Solid Core Construction with block board core and plywood face panels,commercials type on both sides complete all as specified and directeb by Engineer in Charge |
| 38 | S&F for Glazed and Skeleton Shutters 35mm thick 2nd class hard wood open rebated and prepared to receive gauze etc (without sash bars)edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, gauze etc , sizes of memebres of shutters as specified in SSR Part-I section 8 clause 8.20 (a)( wire mesh doors) Supply and fitted to chowkats complete all as specified |
| 39 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified |
| 40 | M&L for Two Coats of Synthetic Enamel Paint over a coat of Pink Primer including preparation of new wooden surface of any description over 10 cm width and girth and all as directed |
| 41 | S/F Stainless Steel Wire Cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless Steel wire staples along with frame work of windows / ventilators/door with all necessary arrangements complete all as specified and as directed. |
| 42 | S&F in Repair Floor Door Stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor |
| 43 | S&F MS helical door spring 300 mm long with roller and roller plate complete all as specified. |
| 44 | S&F CP Curtain Rod / Drapery Rod 20mm dia of approved pattern along with decorative SS brackets of approved quality with knob and pattern fixed with screws all as specified and as directed. |
| 45 | Supply and Fixing Factory made uPVC white colour Three track three panels sliding window with fly proof S.S wiremesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified anddirected by Engineer-in-Charge (Note-The Rate Quoted shal be inclusive of 12mm thick Square Bar MS grill with all finishes, SS Wire mesh and 5mm thick Glass) |
| 46 | (a) Area n.exc. 1.00 sqm each. |
| 47 | (b) Area exc. 1 sqm but n.exc 2.00 sqm each |
| 48 | S& F in Repair CP Shower Rose 125mm with including CP Shower Arm 225mm size. (Make-Jaquar, Hindware, Parryware.) |
| 49 | S&F in Repair Vitreous China White Single Piece Water Closet including all fittings & Seat Cover etc complete all as specificed and as per directed by Engineer-in-Charge. (Make-Jaquar, Hindware, Parryware.) |
| 50 | S&F in Repair Health faucet (ABS Body) CP suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, etc complete all as specificed and as per directed by Engineer-in-Charge. (Make-Jaquar, Hindware, Parryware.) |
| 51 | S&F in Repair Two Way Bib Taps all as specified and directed. (Make-Jaquar, Hindware, Parryware.) |
| 52 | S&F in Repairs, Vitreous China Wash Hand Basin White flat back size 550x400mm with brackets including cutting for and pinning in ends of brackets or erecting stand including Fancy type CP Pillar Tap, Waste Coupling CP brass 32mm dia with long screwed shanks & fly nuts & PVC Waste Pipe complete all as apecified (Make-Jaquar, Hindware, Parryware.) |
| 53 | S&F in Repairs 600x450mm Bevelled Edge Mirror of selected quality glass fixed with SS screws, complete all as specified and as directed by Engineer-in-Charge. |
| 54 | S&F in Repairs Brass CP Wall Mixer for Mixing Hot & Cold Water screwed down for iron pipe and fixed for 15mm dia bore (Make-Jaquar, Hindware, Parryware.) |
| 55 | S&F in Repairs CP Grating Doom 100mm dia, complete all as specified and as directed by Engineer-in-Charge |
| 56 | S&F in Repairs Brass CP Soap Dish, fixed to plugs with chromium plated brass screws all as specified and as directed.(Make-Jaquar, Hindware, Parryware.) |
| 57 | S&F in Repair CP Brass Tubular Towel Rail 600mm long 20mm dia 'D' type complete all as specified . (Make-Jaquar, Hindware, Parryware.) |
| 58 | S&F in Repairs for low density polythelyne pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB etc. 32mm bore complete all as specified |
| 59 | Cutting chases ,pinning in making good to facing where required of brick walls and pointed in cement mortar 1:3 for concealed water tubing etc cutting not exc 10 cm girth. |
| 60 | S&F in Repairs 15mm Bib Taps Fancy Type long body chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferule and fixed.(Make-Jaquar, Hindware, Parryware.) |
| 61 | Taking up or down steel tubing & connections, 15 mm dia complete all as specified |
| 62 | Taking up or down steel tubing & connections, 20 mm dia complete all as specified |
| 63 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with all fittings complete all as specified |
| 64 | (a) 16 mm outer dia |
| 65 | (b) 20 mm outer dia |
| 66 | S & F in Repairs, CP 15mm, Stop Valves / Angle Cock, Fancy type cast copper alloy with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe complete all as specified (Make-Jaquar, Hindware, Parryware.) |
| 67 | S&F 15 mm dia 600 mm long PVC water connection with PTMT nuts and washers all as specified |
| 68 | Dismantling of 1000 ltr water storage tanks and removed to store complete all as specified. |
| 69 | S & F 1000 ltr capacity of rotational moulded PVC water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including float valve complete all as specified and directed. |
| 70 | S & F Gun metal globe or gate valves of 20 mm dia with iron wheel head screwed both ends for iron pipe and fixed in repair complete all as specified |
| 71 | S&F 20 mm bore dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (min weight 210gms) complete all as specified |
| 72 | S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and laid in trenches and under floor etc incl taking down old pipes complete all as specified |
| 73 | S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and laid in treanches and under floors etc incl taking down old pipes complete all as specified |
| 74 | S&F 110mm PVC (SWR) bends any radius complete all as specified |
| 75 | S&F 75 mm PVC (SWR) bends any radius complete all as specified |
| 76 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent to waste pipe fixed in cement concrete type B-1 (1:2:4), 75 mm dia outlet complete all as specified |
| 77 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified |
| 78 | S&F 110 mm PVC (SWR) vent cowl complete all as specified |
| 79 | S&F in repairs for low density polythelyne pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB etc. 40mm bore complete all as specified |
| 80 | S&F in repairs Shelf of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 300 gms) complete all as specified . |
| 81 | Demolitiom of cement concrete of any description and in any position & removing rubbish out of the MD land complete all as specified complete all as specified. |
| 82 | M&L,25mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in padding concrete (levelling course) on roof complete all as specified and as directed by Engr-in-charge. |
| 83 | Rendering 10 mm thick in CM (1:3) using Water proofing compound as per manufacturer instructions as in Roof and all as directed |
| 84 | M&L for APP modified prefabricated five layer water proofing membraneminimum 3mm thick and weighing not lessthan 3.9kg/Sqm, reinforced with non woven polyester matt black finished (wt not less than 150 gms/Sqm) over combatible primewr at 0.40 Ltr/Sqm and torch applications of membrane with minimum 10cm side overlap and 15cm end laps nad applying solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm complete all as specifies and as directed by Engr-in Charge. |
| 85 | Supply only integral watewr proofing compound complete all as specified |
| 86 | Dismantling plain or corrugated steel sheeting, AC Sheets any guage, thickness including Nainital or similar pattern roof covering/wall cladding complete all as specified and directed.((Note : height of the bldg truss is upto upto 7 Metre) |
| 87 | S&F Pre-Painted Galvatume aluminum zinc coating GI based Corrugated Steel Sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Roof Covering / Cladding to Wall, fixed with self tapping screws as specified |
| 88 | Dismantling of steel work of any description and in any position not otherwise specifically provided for and all as directed |
| 89 | S&F MS Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde E- 250) quality A and all as directed |
| 90 | M&L for Two Coats of Synthetic Enamel Paint over a coat of Red Oxide including preparation of New or previously untreated steel surfaces over 10cm in width or girth, not otherwise described in any pattern. |
| 91 | E/M PORTION: Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified. |
| 92 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. |
| 93 | Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FR-LSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall / ceiling including cutting chases and continous earth wire 1.5 Sqmm PVC insulated FR-LSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including Concealed modular metal flush boxes in walls and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc and making good the disturbed surface to match with existing complete all as specified and directed by E-IN-Charge for the following:- |
| 94 | (a) One light point controlled by one, one way switch 6 A, SP |
| 95 | (b) One ceiling fan/exhaust fan point controlled by one, one way switch |
| 96 | (c) One bell point controlled by one bell push. |
| 97 | (e) One 3 point 6 Amps switch socket outlet point controlled by one switch on the same board. |
| 98 | (f) One 3 pin 6 Amps switch socket outlet point controlled by one switch on independent board. |
| 99 | All as per item No 93 here in before but with cable 2.5 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 16 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified |
| 100 | S&F modular switch 1way 6A, 1 module all as specified and directed |
| 101 | S&F modular switch 1way 16A, 1 module all as specified and directed |
| 102 | S&F modular Bell push 6A, 1 module, 230 Volts all as specified and directed. |
| 103 | S&F modular socket, 6A - 2/3 pin combined 2 module, flush tpe all as specified and directed |
| 104 | S&F modular socket, 6A/16A - 2/3 pin combined 2 module, flush tpe all as specified and directed |
| 105 | S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified. |
| 106 | S&F of Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed. |
| 107 | S&F LED lamp 9W complete all as specified and directed by the Engineer-in-Charge. |
| 108 | S&F wall mounted LED tube light fitting 1x20/21/22 extruded aluminium housing and polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6000K & lumen input output 120 Lumen per watt with minimum 50000 burning hrs and suitable rating with surg prtection and driver connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall complete all as specified and directed. Make : Havells/Philips/Crompton/Wipro |
| 109 | S&F wall mounted LED 2 feet tube light fitting 1x10 extruded aluminium housing polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6000K & lumen input output 120 Lumen per watt with minimum 50000 burning hrs and suitable rating with surg prtection and poted driver connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall complete all as specified and directed. Make : Havells/Philips/Crompton/Wipro |
| 110 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps. Havells/Schneider/Standard/C&S/Legrand |
| 111 | S&F modular fan step regulator, 2 module all as specified and directed. |
| 112 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Note : - Old Fan deposit in MES store yard.Havells/Crompton/Bajaj/Khaitan |
| 113 | M & L for Submain wiring with two single core 10 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid PVC conduit of suitable dia, conduit fittings and accessories concealed in wall/floor with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note 1: Two runs of 10 Sqmm cable, one run of 10 Sqmm earth contuinity conductor and one run of conduit shall be measured and paid as one unit length length including qutade rate. |
| 114 | M & L for Submain wiring with two single core 6 Sq mm PVC FRLSH insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including cutting chases in wall concealed rigid PVC conduit of suitable dia, conduit fittings and accessories concealed in wall/floor with one run of 6 sqmm PVC FRLSH insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing including taking down old unservicable sub main all as specified. Note 1: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth contuinity conductor and one run of conduit shall be measured and paid as one unit length length including qutade rate. ( For AC Points) |
| 115 | S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 10 MCB SP as out going including grouting DBs in wall as required complete all as specified and directed.Make: Legrand/Schneider/Simens/ABB |
| 116 | Supply and fixing sheet Metal enclosure double door type for Vertical TPN DB for 125 Amp MCCB as incommer, 08 way with 200 Amps rated bus bar including grouting DBs in wall as required complete all as specified and as directed. MAKE: Legrand/Schneider/Simens/ABB. |
| 117 | S&F MCCB 415 Volt 16 KA 4 pole 125 Amp thermal magnetic trip release & setting ICU= 100% ICS as incoming with fixing arrangement complete all as specified and directed. Make: Legrand/Schneider/Simens/ABB |
| 118 | Supply and fixing MCB SPN 40-63 Amps , 240 volt, 10 KA, complete all as specified and as directed. MAKE: Legrand/Schneider/Simens/ABB. |
| 119 | Supply and fixing MCB SPN 32 Amps , 240 volt, 10 KA, complete all as specified and as directed. MAKE: Legrand/Schneider/Simens/ABB. |
| 120 | Supply and fixing MCB single pole 6 to 40 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge. MAKE: Legrand/Schneider/Simens/ABB. |
| 121 | S&F in replacement of air ventilation fan Plastic (PVC) body Type 250 mm , ,single phase, 250V AC including making necessary hole by breaking existing wall to fix air ventilation fan,with frame fixing holdfastner, bolt,washer etc including connection with twisted white three core flexible copper multistranded conductor cable from ceiling rose to connector all a directed by Engineer-in-charge. Old Ex fan shall be deposited to MES store yard. MAKE:Havells/Bajaj/Crompton/Orient |
| 122 | Taking down the existing unserviceable / defective security light fitting and Supply and fixing LED security light luminaire comprising of pressure die cast aluminium housing heat resistant toughened glass IP-65, photovoltic LDR sensor with separate surge protection 5KA, 35 Watts or higher wattage with making all arrangement for fixing light fitting such replacement of GI pipe bracket made of 40 mm bore medium grade pipe made to shape of 1200 of 70 cm and 50 cm to a overall length of 1.2 mtr for fixing of street light fitting including MS clamps of size 50 x 6 mm flat iron, nuts, bolts and washers of required size painting complete with all necessary electric connection etc all as specified and directed. Make : Havells/Philips/Crompton/Wipro |
| 123 | Supply and fixing GI pipe bracket made of 40 mm bore light grade pipe made to shape of overall length of 1.2 mtr for fixing of security light fitting including MS clamps , nuts & bolts of required size complete |
| 124 | Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 50 Sqmm , 3.5 core all as specified and directed. ( Main panel to VTPN DB ) |
| 125 | Excavation in trenches not exceeding 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard /dense soil for laying / repairing of LT cable / GI pipe. |
| 126 | Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid. |
| 127 | Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 128 | Returning , filling incl spreading levelling watering and well ramming in layers not exc 25 cm thick. |
| 129 | Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm |
| 130 | Supply and fixing medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed Please Enable Macros to View BoQ information |
| 131 | Supply and fixing medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed Please Enable Macros to View BoQ information |