| Sl. No. | Item Description |
| 1 | Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 3 | Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dresssd with earth obdiened from excavation of foundation trenches within a lead of 50 m and lift of 1.5 M all complete as per building specification and direction of E.I (Mode of measurement compacted volume.) |
| 4 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 6 | Providing designation 75 Abrick work in C.M (1:6)in foundation and plinth with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials , raking of joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l |
| 7 | Providing 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer Incharge . |
| 8 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 12 | P.C.C-Providing and lying in position cement concrete of specified grade excluding the cost of centering and shutturing - All work up to Plinth Level1:4:8 ( 1 Cement : 4 coarse sand ( zone-III) : 8 graded stone aggregate 40 mm nominal size ) |
| 13 | Providing 25mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 14 | Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges |
| 24 | Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no |
| 25 | slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 100 mm gap |
| 26 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member |
| 27 | designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists |
| 28 | damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).Roof Joint of 100 mm gap |
| 29 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 30 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 31 | Providing T or steel reinforcement of 8,10 mm, 12 mm, &16 mm dia barsas per approved design and drawing excluding carriage of bars to work site, cutting, bending and binding with annealed wie with cost of wire, removel of rust, placing the rods in position all complete as per building specification and direction of E. |
| 32 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 33 | providing Tor steel reinforcement of 10mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 34 | providing Tor steel reinforcement of 12mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 35 | providing Tor steel reinforcement of 16mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 36 | Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. |
| 37 | supplying , fitting and fixing M.S gril / RECTANGULAR PIPE made of 20x6cmm M.S. FLA asper approved design and drawing , and properly fabricated with joints continous fillet welded and finished smooth , carriage of grill to work site , hoisting as per building specification and direction of E / I WHERE A MATERAIL is not supplied in by the deptt |
| 38 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 39 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I (Cost of Cico will be paid separately) |
| 40 | For StairProviding and laying vitrified floor tiles for step of stair in with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300 mmx15 mm |
| 41 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 42 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 43 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 44 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 45 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 46 | Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I. |
| 47 | Providing two coats of Plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. (OUTSIDE & INSIDE WALL) |
| 48 | Providing French spirit polishing over new wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including preparing the surface after cleaning removing dirt,scales grease including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 49 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 50 | Providing two coats of synthetic enamel paint of apporoved shade and make over steel surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 51 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 52 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet |
| 53 | including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand -1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given |
| 54 | with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready touse, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious |
| 55 | powder -Density 1.6 kg/l (mixed density) at +27°CTensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)(d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 |
| 56 | mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items). All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shallnecessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance Chemical Base Part A: Acrylic copolymer, |
| 57 | Part B: Specially graded cementitious be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\"(e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years. |
| 58 | Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering, and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.- There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+ |
| 59 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 60 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 61 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red. Area of slab over 0.50 sqm |
| 62 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness tobe specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigmentof matching shade complete. |
| 63 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 64 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles tobe reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather sealto be provided through out the frame. The door frame to be fixed to the wall using M.S. screwsof 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. |
| 65 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming |
| 66 | styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the |
| 67 | styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.30mm thick factory made soiled both side Prelaminated Panel PVC door shutter consisting of frame made out MS tube of 19 guage thickness as per your size . |
| 68 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 69 | Ventilator Casement window single panel with or without fixed panel with S.S. 304 frictionhinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coatedhandles.Using R1 series with frame (33mm & above ) x (35mm & above) & sash /mullion (33mm &above) x (50 mm & above). (Height upto 0.90 metre). |
| 70 | Casement window double panels with French (False) Mullion with S.S. 304 fricction hinges as per size and wieght of sash,multi-point locking system,zinc alloy (zamak) power Coated handal Using R3 series with frame (55mm& above)x (45mm& above) & sash (55mm& above) x(65mm&above) & French (Flase) mullion (55mm& above) x(65mm&above). (Height upto 1.8m) |
| 71 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. |
| 72 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 73 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specifiedby the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colourssuch as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointingthe joints with white cement and matching pigment etc., complete. |
| 74 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete |
| 75 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 76 | 75 mm diameter |
| 77 | 110 mm diameter |
| 78 | Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 79 | 75 mm Coupler |
| 80 | 110 mm Coupler |
| 81 | 75 mm Single pushfit Coupler |
| 82 | Single pushfit Coupler-110 mm |
| 83 | Single tee with door of 75x75x75 mm |
| 84 | Single tee with door 110x110x110 mm |
| 85 | Single tee without door 75x75x75 mm |
| 86 | 110x110x110 mm |
| 87 | Bend 87.5° 75 mm bend |
| 88 | Bend - 110mm |
| 89 | 75 mm Shoe (Plain) |
| 90 | Shoe - 110 |
| 91 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete |
| 92 | 75mm dia |
| 93 | 110 mm |
| 94 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 95 | Internal work -Exposed -ON - WallProviding and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. |
| 96 | 25 mm nominal outer dia pipes |
| 97 | 32 mm nominal outer dia pipes |
| 98 | 40 mm nominal outer dia pipes |
| 99 | Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe 150 mm dia. R.C.C. pipe |
| 100 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 101 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 102 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 103 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applyingcement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 104 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stonePattern with anti algae and UV resistance properties to be applied as intermediate finish in desiredpattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43litres/10 sqm, complete as the direction of Engineer -in-Charge. |
| 105 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 106 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100 mm nominal size dia |
| 107 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 108 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 109 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 110 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 111 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 112 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and |
| 113 | resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge.(Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. |
| 114 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 115 | CHIPS |
| 116 | BRICK |
| 117 | Fly Ash |
| 118 | Earthwork in excavation(As per I.S. 3114/1965 for laying of different types and sizes of pipe so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.(a) For classification of soil item - A ( 20 x 0.6 x 0.6 ) |
| 119 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification for soil item-A& B |
| 120 | Supplying fitting and fixing the following items complet with all material s as per direction of E/I. (b) (i) 600x450mm mirrors of 6mm thick., |
| 121 | Supplying, fitting and fixing vitreous white glazed earthen wareI.W.C. Of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 15liters C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fittings,C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mmP.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxideprimer etc. all complete as per specification and direction of E/I. (A) 580 mm long(a) With 10ltr low level PVC cistern |
| 122 | Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I.(b) With 10 ltr low level PVC cistern |
| 123 | Supplying, fitting and fixing flat back or angular,lipped front vitreous white glazed earthen ware Urinal (Boys ) of Hindustan Parry or any other I.S.S approved make with 5 litres C.I automatic flushing cisterns of reliance for any other I.S.S approved make wihall fittings with C.I or R.S brackets, standered sizes G.I.flush pipe with fitting clamps, 15mm C.I body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C / Alkthene pipe 450mm long with brass coupling at both ends and doing plumbers joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same rtc. all complete as per specification and direction of E/I. |
| 124 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of Parry Hindustan or any other I.S.S approved make supported on painted C.I or R.S brackets 32mm C.I brass waste, 15mm dia C.I body brass spindel stop cock of approved quality of weight not less than 350 grams, 32mm PVCwaste pipe 750 mm long with brass coupling at one end and making plumber joints etc . all complete as per specification and direction of E/I. |
| 125 | Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. |
| 126 | (i)125mm thick wall |
| 127 | (ii)250mm thick wall |
| 128 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 129 | Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required. |
| 130 | Group B |
| 131 | Group C |
| 132 | Twin Control Point wiring in PVC conduit, with modular type switch:-Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch,modular plate, sutiable size G.I box etc as requried. |
| 133 | Circuit /sub main wiring in PVC conduit :-Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. |
| 134 | 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 135 | 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 136 | 2x4.0 sq.mm + 1x4.5 sq.mm earth wire |
| 137 | 2x10 sq.mm + 1x10 sq.mm earth wire |
| 138 | S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried. |
| 139 | 75 mm x 75 mm x 50 mm deep / (4\\" x 4\\" ) |
| 140 | 72 mm x 146 mm x 48 mm deep / (4\\" x 7\\" ) |
| 141 | 210 mm x 206 mm x 48 mm deep / (10\\" x 12\\" ) |
| 142 | S/F Modular type switch / socket :-Supplying and fixing following modular type switch /socket on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 143 | 5/6 amps, one way switch |
| 144 | 5/6 amps, 3 pin socket outlet |
| 145 | S/F Modular type Electronic Fan Regulator-Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 146 | S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate and switch box exculiding modular plate etc.as requried. |
| 147 | S/F power plug point with modular type accessories :- Supplying and fixing sutiable size G.I. box with modular plate cover in front on surface or in recessed including providing and fixing 6 pin , 15/16 amps modular socket outlet and 15/16 amps modular switch connection , painting etc, as requried. |
| 148 | S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried. (Tube+Fan) |
| 149 | S/F Batten holder :-Supplying and fixing battrn / angle holder including connection etc as requried. |
| 150 | ITC fluorescent fitting directly on surface :-Intallation testing and commissioning of pre wired fluorescent TUBE fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling / wall including connection with 1.5 sq. mm. FR PVC insulated copper conduit as requried. |
| 151 | ITC celling fan :- Installation, testing and commissioning of celling fan, including wiring the down rods of standerd leanth (upto 30 mm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as requried. |
| 152 | ITC Exhaust fan upto 450 mm. sweep:-Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the holeto suit the size of the above fan, making good the damage, connection, testing, commissioning etc as required. |
| 153 | S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. |
| 154 | 16 amps, double pole |
| 155 | 32 amps, double pole |
| 156 | 63 amps, double pole |
| 157 | 32 amps, TP&N |
| 158 | S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried. |
| 159 | 200 amps, TP&N, HRC |
| 160 | 400 amps, TP&N, HRC |
| 161 | S/F Busbar chamber :-Providing and fixing following capacity busbar chamber with 4 strips of sutiable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc as requried. 400 amps |
| 162 | S/F Panel montude change over:-Providing and fixing following capacity 4 pole panel mounted change over switches in existing cubcile panel board, making connection earthing the body etc as requried. |
| 163 | S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 164 | 4way,Single door |
| 165 | 6way,single door |
| 166 | 8 way , single door |
| 167 | 4way, Double door |
| 168 | 16way,Double door |
| 169 | S/F S.P. MCB DB :-Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphatize and powder painted inculiding earthing etc.as required.(But without MCB/RCCB/Isolator) 4way (4+12), Single door,Horizontal type |
| 170 | S/F 'C' serise, MCB:-Suppling and fixing ,240 volts \\"C\\"serise miniature circuit breaker suitable for inductive loads of follong poles in the existing MCB DB complete with connections, testing and commisioning etc. as required . |
| 171 | 6/32 amps, Single pole |
| 172 | 50/63 amps TPN |
| 173 | S/F SP MCB blanking plate :-Suppling and fixing Single pole blanking plate inexisting MCB DB complete etc. as required . |
| 174 | Copper earth plate electrode:-Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt). |
| 175 | S/L 8 SWG copper wire in ground:-Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried. |
| 176 | S/L 25mm x6mm G.I. earth strip in ground :-Supplying and laying 25mm x6mm G.I. strip at 0.50 metre below ground as strip earth eletrode, incoluding soldering etc .as requried. |
| 177 | P/F G.I lighting conductor finial :-Providing and fixing of lighting conductor finial, made of 25 mm dia 300mm long, G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc as rqquried. |
| 178 | Reverting sweating and soldring lighting conductor tape:-Reverting sweating and soldring of copper / G.I tape (with another copper/ G.I tape, base of the final or any another metalic object) as requried. |
| 179 | P/F G.I lighting conductor tape in vertical run :-Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as requried.( for horizontal run ). |
| 180 | P/F Testing joint for G.I lighting conductor :-Providing and fixing testing joint, 20 mm x 3 mm thick copper strip 125 mm long , with 4 nos. of G.I bolts, nuts, check nuts and spring washers etc. complete as requried. |
| 181 | P/F coppre earth tape for lighting conductor :-Providing and laying copper tape 32 mm x 6 mm from earth electrode directly in ground as requried. |
| 182 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to 15:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC ansulated, copper wire suitable for 230V 50Hz, single phase supply etc complete as required.1200MM (48\\")Ceiling Fan |
| 183 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 184 | 10/12 . Watt LED LIGHT |
| 185 | 20/22 . Watt LED LIGHT |
| 186 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, (SINTEX / SINTER) ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but withoutfittings and the base support for tank. |
| 187 | Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004 |
| 188 | 9\\" (230mm) metal exaust fan |
| 189 | 12\\" (300MM) metal exaust fan |
| 190 | 15/16 Watt LED BULB |
| 191 | Bulk head fitting with 9/10 Watt CFL/LED |
| 192 | Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) |
| 193 | piller Cock (Long Neck) |
| 194 | Bib Cock (sort Neck) |
| 195 | Bib cock (Long Thread) for sink |
| 196 | Towel Rail 24\\" |
| 197 | Toilet Paper Holder |
| 198 | Glass shelf 22' |
| 199 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up toSite. |
| 200 | (a) From 0.00 M to 50.00 M below G.L. |
| 201 | (b) From 51.0 M to125.00 M |
| 202 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP |
| 203 | Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase 50hz with no coil. Over load element , On _OFF push buttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914.F.A.S.D starter upto 10.0 H.P |
| 204 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel 610MMX510MM BOUL Depth 200 mm |
| 205 | 3 core PVC insulated PVC sheathed copper conductor flat submersible cable.Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:70983 Core 4 Sq mm |
| 206 | Total Schedule Item |
| 207 | Non-Schedule Item |
| 208 | Supplying, placing & fitting Metal Beds (Without Mattress) With Frame of SS 202 Pipe Over all length of Bed in mm (±10 mm) 2000Overall width of Bed in mm (±10 mm) 915 Size of Square Hollow Section ±1(mm) 32 mm X 32 mm Material of mattress panel SS 202 Perforated / Sheetwith all complete as per direction of E/I.. |
| 209 | Supplying chair of Single Piece Plastic Moulded Seat Cushion Without Back Cushion Without Plastic MaterialS Minimum seat height from floor surface (mm)<=400Width of seat (mm) >400<=450Depth of seat (mm) >400<=450 Width of backrest (mm)>400<=450Backrest height from the seat level >450<=550 with all complete as per direction of E/I.. |
| 210 | Supplying, placing & fitting Executive Table with One side pedestal unit L X D & H 1200 millimeter X 600 millimeter 750 millimeter Storage Provided one sideNumber of storage unit single storagePrelaminated particle board(Wood Product) of grade II type II of IS 12823/Lates of 18 mm |
| 211 | Supplying, placing & fitting 3 Seater Public Place Seating Chair of M S ERW tube with arm and backrest WITHOUT CUSHIONMaterial of Main Frame MS ERW TubeOverall Length in mm (±10 mm) 1655Overall Depth in mm ( ±5 mm) 665Overall Height in mm (±5 mm) 870Seat Height from Floor in mm (±5 mm) 425 mm with all complete as per direction of E/I. |
| 212 | Supplying, placing & fitting k Portrait/ Landscape Acrylic (minimum 2mm thickness) Fabric Pin Up Notice Boards Width of Board in mm 1200 mmColour(Front/ Display layer) RedHeight of Board in mm 1800mm with all complete as per direction of E/I. |
| 213 | Supplying, placing & fitting Potable water purificationsystem with inbuilt water cooler. RO +UVFilteration water capacity in liter/ hour 60 Storage tank capacity up to float valve level (in liter) 80Stages of purification 5 Input water hardness 500 ppm or lesswith all complete as per direction of E/I. |
| 214 | Supplying, placing & fitting of Cafeteria Table of 8 Capacity with Length of Table Top / Diameter of Table Top if the Shape is Circular with a tolerance of ± 10 mm1950 millimeterWidth of Table Top with a tolerance of ± 10 mm750 millimeterHeight of Table with a tolerance of ± 10 mm800 millimeter all complete as per direction of E/I.. |
| 215 | Supplying, placing & fittingCafeteria Chair Without ArmrestMaterial of the Chair Under structureMoulded PlasticHeight of Chair Seat from ground with a tolerance of ± 10 mm550 millimeterOverall Height of Chair from ground with a tolerance of ± 10 mm950 millimeter with all complete as per direction of E/I.. |
| 216 | SB Collection Red Colored Steel Shelving CabinetsSB CollectionR (JUSB-07) (34\\" x 18\\" x 60) |
| 217 | Add GST 18 % |
| 218 | Add Labour cess 1% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail