Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 2 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 3 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means ncluding stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 4 | 15 mm to 40 mm nominal bore |
| 5 | Above 40 mm nominal bore |
| 6 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 7 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 8 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 9 | Dismantling R.C.C.work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 10 | Removal of old tarfelt and disposal of debris with all leads complete job as per direction of E/l. |
| 11 | Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. |
| 12 | Taking down choukhat in doors including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. |
| 13 | Taking down choukhat in windows including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. |
| 14 | Taking down ceiling (any type) and refixing them after repair with department material, within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 15 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 16 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 21 | Providing Toe steel reinforcement of dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) |
| 22 | Providing Toe steel reinforcement of 8mm dia rods as approved |
| 23 | Providing Toe steel reinforcement of 10 mm dia rods as approved |
| 24 | Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved |
| 25 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 26 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 27 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 28 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 30 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 32 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, complete as the direction of Engineer -in-Charge. |
| 33 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 34 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 35 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour Tiles. |
| 36 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm |
| 37 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete w i t h : Second class teak wood |
| 38 | Providing primer one coat of approved shade and make over new wooden surface including preparingthe surface after cleaning, removing dirt, scales, smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 39 | Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 40 | Providing French spirit polishing over new wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including cleaning the surface after removing dirt,scales grease including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 41 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l |
| 42 | Supplying, fitting & fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 43 | Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 44 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick |
| 45 | Factory made prelaminated PVC rigid foam sheet 5 mm thick |
| 46 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 47 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 48 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 49 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 1 4 , plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge |
| 50 | Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 -- Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1 . 2 metre). |
| 51 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 52 | Providing and fixing tiled false ceiling of specified materials of size595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 1 2 . 5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1 2 . 5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I , of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 53 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 54 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps :- (a) Surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jel including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand: Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder - Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4N/mm2 (According to FIP 5.15) Elongation at Break ~35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamfered vrith 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder - Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4N/mm2 (According to FIP 5.15) Elongation at Break ~35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) |
| 55 | Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.-There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+ |
| 56 | Providing and filling of 6mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST).Brand:-Sika Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent. |
| 57 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 58 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 59 | Bend 87.5° 110 mm bend |
| 60 | Shoe (Plain) 110 mm Shoe |
| 61 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 62 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complet |
| 63 | Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 64 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 65 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 66 | Brick - 7 +1 km ( 8Km) |
| 67 | Sand - 10 km |
| 68 | Chips - 22 Km |
| 69 | Metal - 22 Km |
| 70 | Point wiring in PVC conduit, with modular type switch - Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required Gr-C |
| 71 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 72 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 73 | 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 74 | 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 75 | 2 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire |
| 76 | 4 x 6.0 sq.mm. + 2 x 6.0 sq.mm. earth wire |
| 77 | Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 4 sq.mm. |
| 78 | TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required. |
| 79 | S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20mm |
| 80 | S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 75mm x 75mm x 50mm deep/(4\\" x 4\\") |
| 81 | S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. |
| 82 | 5/6 amps, one way switch |
| 83 | 15/16 amps, one way switch |
| 84 | 3 pin 5/6 amps, socket outlet |
| 85 | TV antenna socket outlet |
| 86 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 87 | Supplying and fixing Modular type blanking plate-Supplying and fixing modular blanking plate on existing modular plate switch box excluding modular plate etc. as required. |
| 88 | Supply & fixing 20A SPN MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for socket out let and complete with connections, testing and commissioning etc as required. |
| 89 | Providing & fixing : Porviding and fixing of MV danger notice plate of 200mmX150 mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 90 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 5 pin, 5/6 amps socket outlet and 5/6 amps piano tyep switch connection, painting etc. as required. |
| 91 | S/F power plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as requird. |
| 92 | S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 93 | S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required. |
| 94 | ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit. |
| 95 | ITC Fluorescent fitting with down rods - Installation, testing and commissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20mm dia stee. |
| 96 | ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required. |
| 97 | ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 98 | S/F MCCB in cubical panel board: Supply and fixing following rating & capacity 4pole MCCB in existing cubicle panel board. Including drilling holes in panel , making connections etc as required. |
| 99 | 25 to 100A, 16kA fixed thermal rating( to be used as incomer for light & UPS SDB as floor, wall mounted panel) |
| 100 | 125A, 16kA fixed thermal rating( to be used as incomer for tap off bay of rising mains) |
| 101 | 160A, 35kA fixed thermal rating( to be used as incomer for SDB as floor wall mounted panel) |
| 102 | 200A, 35kA-(5 nos )fixed thermal setting with spreader links( to be used as incomer for tap off box of rising mains & 1 no for UPS room SDB) |
| 103 | S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, double door |
| 104 | S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 105 | 4 way (4 + 12), Double door, Horizontal type |
| 106 | 6 way (4 + 18), Double door, Horizontal type |
| 107 | S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required. |
| 108 | 6/32 amps, Single Pole |
| 109 | 40 amps, TPN |
| 110 | 40 amps, DP |
| 111 | 50/63 amps, DP |
| 112 | S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required |
| 113 | 40 amps |
| 114 | 80/100 amps |
| 115 | MV cable laying upto 120 sq.mm. in ground without sand and cover - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering. |
| 116 | MV Cable :- Supply of ISI marked aluminium cable conductor XLPE PVC Insulated Cable as per I.S :7098 armoured , served shaelthed 1100V grade with Termination and laying of cable . |
| 117 | Supply of ceiling fan :- Supplying and fitting of 1400mm sweep regular /standared model AC fan , including connection with 1.5 sqmm copper wire down rod of standered length ( upto 30cm ) with all acessories as required |
| 118 | Supply of Exhaust Fan :- Supply and fitting of 300 mm , 230V AC metal exhaust fan in the existing opening including making good the damage , connection testing commisioning etc as required |
| 119 | Led tube with batten 20W/22W :- Supply and fixing of wall mounted LED 20W/22W tube+ batten electronic driver and acessories as required . |
| 120 | 16\\" (400 mm ) Wall Mounted Fan |
| 121 | Led bulb 9W/10W :- Supplying and fixing of LED 9W/10W bulb and acessories as required . |
| 122 | 15/16W Led Round Down Light |
| 123 | 1' X 1' LED Panel Light |
| 124 | 2' X 2' LED Panel Light |
| 125 | 90/100 W LED Flood Light |
| 126 | 2.0 Tr 5 Star Split AC ( Inverter Type ) IS 1391 Part 1 |
| 127 | Copper Tube of size 5/8\\" for split AC unit 1/1.5/2/3 tr capacity including nitride rubber insulation |
| 128 | 5 KVA wall mounted automatic voltage stablizer from range 140 V to 280 V |
| 129 | Drain Pipe for AC |
| 130 | Outdoor Stand for 2.0 Tr Split AC |
| 131 | FR PVC insulated 3 Core 4 sq.mm copper wire |
| 132 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 580mm. long - with 10 litre low level PVC cistern |
| 133 | Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \\"P\\" trap (b)10 lit. low level P.V.C. cistern |
| 134 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. Flat back or standard corner (600mm x 350mm) |
| 135 | Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri ) with cover & locking system |
| 136 | Angular Stop Cock ( Long Thread ) ( ISI Marked ) |
| 137 | Towel Rail 24\\" |
| 138 | Towel Ring |
| 139 | Bib Cock ( ISI Marked ) |
| 140 | Bib Cock ( Long Thread ) ( ISI Marked ) |
| 141 | Soap Disk |
| 142 | Central hole basin mixer ( ISI Marked ) |
| 143 | 15 mm C.P. Nipples |
| 144 | 100 mm dia steel jali |
| 145 | Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 146 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. (i) 600mm X 450mm size |
| 147 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I. |
| 148 | Providing and fixing 15mm dia and 45cm. Long P.V.C. Connection pipe with heavy quality brass coupling at both ends etc. All complete as per specification and direction of Engineer-in-charge. |
| 149 | Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I. |
| 150 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178 mm |
| 151 | Providing and fixing N.P/ C.P. Brass/ P.V.C. Porcelain shower rose of 15mm inlet etc. All complete as per specification and direction of E/I. (c) 150mm dia C.P. Shower |
| 152 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the wall etc.. |
| 153 | 20 mm nominal outer dia Pipes |
| 154 | 25 mm nominal outer dia Pipes |
| 155 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 156 | 25 mm nominal outer dia Pipes |
| 157 | 32 mm nominal outer dia Pipes |
| 158 | 40 mm nominal outer dia Pipes |
| 159 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 0 mm gap for thermal expansion, (i) Single socketed pipes. |
| 160 | 75 mm diameter |
| 161 | 110 mm diameter |
| 162 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 163 | 75 mm Coupler |
| 164 | 110 mm Coupler |
| 165 | 75 mm Single pushfit Coupler |
| 166 | 110 mm Single pushfit Coupler |
| 167 | 75 mm Single tee with door |
| 168 | 110 mm Single tee with door |
| 169 | 75 mm Single tee without door |
| 170 | 110 mm Single tee without door |
| 171 | 75 mm Bend 87.5° |
| 172 | 110 mm Bend 87.5° |
| 173 | 75 mm Shoe (Plain) |
| 174 | 110 mm Shoe (Plain) |
| 175 | E LIBRARY TABLE |
| 176 | BOOK SHELF |
| 177 | EPSON Short Throw (0.41 to 0.9) Multimedia Projector (MMP) With 1280 x 800 (WXGA) Resolution EPSONR (EPSON EB-L210SW) |
| 178 | ELCOR Motorised Projector Screen, On Site OEM Warranty 1 ELCORR (ELCOR PRO Series Electric ALR tab-tensioned 100-Inch Diagonal In 16:10) |
| 179 | Dell Intel Core i5 10500 8 GB/ 1000 GB HDD/ Windows 10 Home DellR (Dell OptiPlex 3080 MT) |
| 180 | VISTA Blackout roller blind VISTAR (ROLLER BLINDS) |
| 181 | DURIAN Wooden Podium design Gable end and modesty panel and top material Three layer prelaminated particle board(Wood Product) of grade II type II of IS 12823/Latest DURIANR (VENETTO) |
| 182 | DKG FURNITURE--M/S SINGH GRAMODHYOG Seat only Chair Count 3 DKG FURNITUREUR Unregistered Brand Manufactured by: M/S SINGH GRAMODHYOG (DKG FURNITURE -- Seat only Chair Count 3) |
| 183 | FURNIKRAFT Sofas & Couches, Number of seats 6 FURNIKRAFTR (HSF-111) |
| 184 | SAINYKCRAFT Modular Table with Glass Table Top and Wooden/ Engineer Wood Understructure SAINYK CRAFTR (NSSI/MT/0126) |
| 185 | Nilkamal Modular Table with BWP Ply Table Top and Metal Understructure NilkamalR (Nilkamal Customize Optimize Table) |
| 186 | DURIAN Low-back Chair With Fixed armrest with Cushion DURIANR (BZT/60102) |
| 187 | DURIAN Mid-back Chair With Fixed armrest with Padding DURIANR (RICH/37816 6716544) |
| 188 | Add 18 % GST (in Basic Rate must fill 12) |
| 189 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |