Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil @ 70% and ordinary rock @ 30% |
| 3 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres. All kinds of soil |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres. ordinary rock |
| 5 | providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) with 20 % Plum |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) with 20% pilum |
| 11 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 14 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 15 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished withOUT floating coat of neat cement slurry but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 16 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 17 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 18 | Dry random rubble masonry with hard stone in foundation and plinth: With bond stone. |
| 19 | Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone |
| 20 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 21 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete. 1000 mm dia. R.C.C. pipe (laying by manual/mechanical means) |
| 22 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete. 600 mm dia. R.C.C. pipe. |
| 23 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. |
| 24 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels granitie of any colour or shade 18mm thick (Area of slab over 0.5 sqm) |
| 25 | Providing and Fixing Stainless Steel (304 -exterior Grade Alphanumeric of required specification as as approved by engineer in chARGE |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work . |
| 27 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 28 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 29 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge |
| 30 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood |
| 31 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's nd drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 32 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 33 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer |
| 34 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 35 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm |
| 36 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Twin rubber stopper |
| 37 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 38 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colou r& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 39 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 40 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part-I : 2011 (Board with BIS certification marks) |
| 41 | Providing and fixing plained eaves boarding. 2nd class Deodar wood 300x40 mm (nominal size) |
| 42 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 43 | Providing and fixing charcoal Louvers ( decorative wall Panels) made of Charcoal powder Design and additives often with polystyrene for strength and Resistance to Distortion, moistures ,termites and Mold Resistant of size 0'-8\\" x 9'-6\\" x12 mm thick |
| 44 | P/F OF JAGUAR/KOHLER WALL MOUNTED RIMLESS SEAT INCLUDING SEAT COVER, CONCEALED CISTERN TANK & FLUSH CONTROL PLATE, NECESSARY 4.5\\" BRICKWORK, ALL REPAIR WORK NEEDED& FITTINGS INCLUDED AS PER DIRECTION OF ENGINEER IN CHARGE |
| 45 | P/F OF JAGUAR/ KOHLER MAKE TABLE TOP WASHBASIN 700X435X135 MM |
| 46 | P/F CP FITTING OF JAGUAR/KOHLER MAKE |
| 47 | ANGLE VALVE |
| 48 | bib cock |
| 49 | telephone wall mixer |
| 50 | Basin mixer |
| 51 | Over head Shower |
| 52 | towel road |
| 53 | towel ring |
| 54 | glass shelf |
| 55 | soap case |
| 56 | P/F JAGUAR/KOHLER MAKE |
| 57 | soap dispenser |
| 58 | CP GRATING ANTI-COCKROACH |
| 59 | WASTE COUPLING |
| 60 | WASTE PIPE |
| 61 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes |
| 62 | 75 mm dia |
| 63 | 110 mm dia |
| 64 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler :- |
| 65 | 75 mm |
| 66 | 110 mm |
| 67 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single push fit coupler :- |
| 68 | 75 mm |
| 69 | 110 mm |
| 70 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door :- |
| 71 | 75x75x75 mm |
| 72 | 110x110x110 mm |
| 73 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door :- |
| 74 | 75x75x75 mm |
| 75 | 110x110x110 mm |
| 76 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC PLAIN BEND (of reqd. degree) :- |
| 77 | 75 mm bend |
| 78 | 110 mm bend |
| 79 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC DOOR BEND (of reqd. degree) :- |
| 80 | 75 mm bend |
| 81 | 110 mm bend |
| 82 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC REDUCER DOOR TEE :- 110 mm X 75 mm |
| 83 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC OFFSETS :- 110mm |
| 84 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC Reducer :- 110mm x 75mm |
| 85 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC VENT COWL :- |
| 86 | 75 mm dia |
| 87 | 110 mm dia |
| 88 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. PVC FLOOR/NAHANI TRAP :- 110 mm X 75 mm |
| 89 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (plain) |
| 90 | 75 mm shoe |
| 91 | 110 mm shoe |
| 92 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 93 | Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length15 mm nominal bore |
| 94 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall |
| 95 | 15mm dia nominal bore (medium) |
| 96 | 20mm dia nominal bore (medium) |
| 97 | 25mm dia nominal bore (medium) |
| 98 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore |
| 99 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 25 mm nominal bore |
| 100 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 101 | Providing and Fixing G.I.Tank Nipple of suitable dia ISI marked as approved by the Engineer-in-charge at site all complete incl. testing of fittings and joints for leakage etc 25 mm nominal bore |
| 102 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 103 | Providing and fixing of stainless steel Rainwater Khurra Jali to be placed at roof and mumty levels, square or circular in shaper of dia/size :- 150 mm |
| 104 | Providing and installation of 1.5 H.P. three phase water pump with all fittings, connecting inlet and outlet, fixtures, electrical connection and starter all complete:- |
| 105 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay (non modular) bricks |
| 106 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 107 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 108 | Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design:Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating. |
| 109 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 110 | Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in Charge. 18 mm thick |
| 111 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 112 | Providing and fixing of Zebra blinds of approved colour made from 100% polyester yarn coated with fade resistant polymer to ensure complete opaquely with zero light transmittance having suitable grating an exterior, including all fixtures and fittings complete in all respect as per design andinstruction of the E.I.C (complete job |
| 113 | Dumping stone including cost of stones. in Horizontal on level |
| 114 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 115 | CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand |
| 116 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete. |
| 117 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 118 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. |
| 119 | FORM WORKCentering and shuttering including strutting, propping etc. and removal of form for: |
| 120 | Columns, pillars, piers, abutments, posts and struts. |
| 121 | foundations , footings ,bases of columns, etc. |
| 122 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 123 | edges of slab and breaks in floor and wall above 20 cm. |
| 124 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 125 | Suspended floors, roofs, landings, balconies and access platforms. |
| 126 | Edges of slabs and breaks in floors and walls (Under 20 cm wide) |
| 127 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 128 | Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level |
| 129 | 15mm Cement plaster on the rough side of single or half brick wall of mix: ( 1 cement : 6 fine sand) |
| 130 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 131 | Making grooves in between concrete and brick work joint all complete job |
| 132 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigmentsetc. complete (Anti skid) of size 600 x 600 mm |
| 133 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 134 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 135 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishingthe top smooth and curing complete |
| 136 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 137 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 138 | Frames and trusses Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood |
| 139 | Providing and fixing factory made flush door shutters 30 mm thick made of pre-laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type II) having one side decorative lamination of approved shade and other side balancing lamination including second class teak wood lipping of 25mm widex12mm thick with necessary screws and black enameled M.S. butt hinges complete as per directions of Engineer- in-charge |
| 140 | ELECTRICAL WORKS Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 15 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc, as required. Group-A |
| 141 | Wiring for light/power plug with 2x4 sq. mm FRLS/HFFR PVC INSULATED COPPER conductor single core cable in surface/recessed medium class PVC conduct along with 1 No. 4 sq mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required |
| 142 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required |
| 143 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 144 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 145 | 4 X10 sq. mm + 2 X 6 sq. mm earth wire |
| 146 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC condu as required. 1 x 1.5 sqm |
| 147 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 148 | Supplying and fixing following modular switch/ socket on the existing modula plate & switch box including connections but excluding modular plate etc. as required |
| 149 | 5/6 A Switch |
| 150 | 3 pin 5/6 socket outllet |
| 151 | 15/16 Amp Switch |
| 152 | 6 pin 15/16 Amp Socket Outlet |
| 153 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 154 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 155 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 156 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required |
| 157 | Supplying and fixing following size/ modules, GI box alongwith modutar base & cover plate for modular switches in recess etc as required. |
| 158 | 1 or 2 Module (75mm x 75mm) |
| 159 | 4 Module (125mm x 75mm) |
| 160 | 6 Module (200mm x 75mm) |
| 161 | 8 Module (125mm x 125mm) |
| 162 | supply and erection of sheet metal double door distribution boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3 IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrodued neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no, of waysfor mounting miniature circuit brakers/ RCBO's/ RCCB's in the distructuion board with provision DP MCB's/RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontol distruction board with provision TPN/FP MCB's/RCCB's/RCBO's as incomer and SP MCB\\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc 6 way (4=18). DOBULE DOOR) (TPN TYPE) |
| 163 | providing and fixing of 240/415 v AC MCB with positive isolation of 10 kA breaking capacity (B/C/D triping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828 (1996)/conforming to IEC 60898-1 2002, IEC 60947-2. low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, Minimum phase termination capacity of 35 sq mm conductor line load reersibility, IP 20 contact pretection and fitted in existing distribution board/sheets, minimum electrical operation 20000 upto 20 A rating and 10000 upto 63A, 5000 for 80A and above rating including making connections, testing etc as required OEM shall have submit NABL/CPRL/ERDA accrediated lab type test reports and all as per approved by engineer in charge |
| 164 | Single pole 6/10/16/32 Amp |
| 165 | TPN 63 Amp |
| 166 | Supplying & fixing of LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt P.F>,90 |
| 167 | Supplying, installation, Testing & Commissioning of 40 watt LED marface mounted Batten light of following body material construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency 85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10%, P. F20.95, IP20, CRI-80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000K/5700K/6000K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved Embossing/ Screen printing on housing. complete in all respect i/e connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 2105 120 lm/Watt output. LM79 & LM80 Test report from NABI. lah for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/Extruded aluminium Body (Thickness >=21.20 mm) |
| 168 | LED Down lighter (SMD Type) (System lumen effiency 105120)Supplying, Installation, Testing & Commisioning of LED Recessed/surface Down lighter (Round square Rectangular) SMD type of following body material with PMMA and prismatic diffiner and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hr. Operating temp range-50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10%, P. F20.95, IP20, CRI >80, UGR (Unified Glare Rating) 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000K/4000K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <1, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 2105 and <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium 18 watt |
| 169 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 170 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos, metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required 1200mm, service value >= 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 171 | Exhaust Fan 300 mm SIZE (METTALIC) |
| 172 | LED street light fixture, Powder coated pressure die cast aluminium body (system lumen efficacy>=105<120 lm/watt) supplying, installation, testing and commissioning of street light LED fixture powder coated pressure die cast alumininum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 volt AC, frequency 50/60 hz operating temp range -50C to 500C, internal surge protection of 5kv L,N,E as pr IEC610000-3-2, P.F>= 0.95,IP-66,IK -10,CRI>70, under voltage and over voltage protection, EMIEMC as per CISPR- 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement suiable to fit in up to 65 mm dia pipe, life time (LED Driver and electrical circuitry ) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life endsas per LM80 extrapolation IES TM-21-11 report, CCT 3000k/4000K/5700K/6500K (as per ANSI Bin) SDCM (STandard Deviation colour matching ) <5 Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor singlel core cable and earthing etc as required with Minimum 5 year OEM warranty system Lumen efficacy >=105<120 lm/watt output LM 79 and Lm80 test report and all testing required for lED fixtures as per BiS shall be submitted. Shape size and CCT shall be as approved by Engineeer-in-chief as pre requirement (Thermal management hear sink of aluminium housing such that LED junction temperatrure shalll not rise aboe 90 degree C) 100 watt |
| 173 | Earthing with copper earth plate 600 mm X 600 mm X 13 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/coke and salt as required. |
| 174 | Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. |
| 175 | providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required |
| 176 | SITC of walVfree standing floor mounted dint and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure(h) Panel shall be duty treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Ncoprene rubber gasket of not less than Imen thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm). hinged door with locking arrangement for equipment/switchgear Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (125) (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 177 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type. Adjustable type) |
| 178 | 160 Amp. 36 KA, FP MCCB ICU 100% ICS |
| 179 | ON Load Change Over Switch FP 100 amp. (Front operated) |
| 180 | Aluminium Bus Bar 300 Amp set of 4 strips 18\\" |
| 181 | Aluminium Bus Bar 300 Amp set of 4 strips 18\\" |
| 182 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 183 | Supplying & laying of PVC insulated and PVC sheathed/XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 35 sq mm x 3.5 core |
| 184 | Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser) of following capacity along with PVC Pipes etc as required (5 star with 8 bar pressure) 35 ltr |
| 185 | Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 No. long tubular batteres 165 AH with 36 months Guarantee and trolly of suitable size. |
| 186 | Supply of following electrical appliancesElectric Kettle upto 1 Ltr. Capacity. |
| 187 | Supplying of LED TV Ultra HD 4K (43 inch). |
| 188 | Supplying of Refrigerator (Double door) 185 ltr |
| 189 | Supplying, Installation, Testing and commissioning of following type of Water Purifiers along with PVC connecting pipes as required (R/o + UV+ UF) Mineral Control and TDS Control |
| 190 | Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Hot/Cold (all weather) type of minimum capacity following Specification as detailed below.1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above8. Noise level (indoor unit); close to 35 dB6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V + 30/50Hz/Single Phase9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211 Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A)16. Should have air filtering mechanism for removing dust17 Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required. |
| 191 | Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation.4 KVA |
| 192 | Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC |
| 193 | Supplying & fixing of drain pipe for indoor unit 1\\" |
| 194 | Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC |
| 195 | Carriage of Material by MT |
| 196 | Sand avg. lead 95 km |
| 197 | Stone agg. Above 40mm lead 25km |
| 198 | Stone agg. Below 40mm lead 25 km |
| 199 | stone lead 10km |
| 200 | Brick avg. lead 105 km Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy