| 1 | Earthwork in excavation inord.soilincluding all charges (S.I.No251) |
| 2 | Concrete with 4 cm gauge brick ballast, fine sand and cement in proportion of 1:4:8 in foundation including supply of all materials labour and T& P etc required for proper completion of the work.(S.I.No275) |
| 3 | M-150 class brick work in 1:4 cement and coarse sand of 1.25 FM mortar in foundation and plinth including supply of all material labour aand T&P etc required for proper completion of the work(S.I.No 303) |
| 4 | R.C.C. work with cement , coarse sand and 2 cm gauge stonr ballast in the proportion of 1:1.5:3 in lintels of doors and windows execulding supply of reinforcementbut i/c all.( S.I.No 289) |
| 5 | R.C.C. work with cement , coarse sand and 2 cm gauge stonr ballast in the proportion of 1:1.5:3 in lintels of doors and windows execulding supply of reinforcementbut i/c all.( S.I.No 287[A]) |
| 6 | M150 class brick work in 1:6 cement & c/sand mortar in super structure for wall of one brick thick i/c all material , labour T & P etc all complete.(303+309+310) |
| 7 | 12 mm thick 1:4 with cement and coarse sand bearing plaster with neat cement finished i/c supply of all material , labour and T & P etc all complete.( S.I.No 583) |
| 8 | R.C.C. work with cement coarse sand and 20 mm gauge stone gritt in the proportion of 1:1.5:3 i/c of all materials, labour T&P etc. for slab.(S I No 284[A]) |
| 9 | M.S. or iron work in plain R.C.C. work i/c cutting , bending & binding all completed work .[ S.I.No 504) |
| 10 | Earth filling in ordinary soil in plinth i/c ramming and dressing in the surface to required levels & slopes and also i/c 1.5 mtr lift and 30 mtr lead with cartage distance of cartage 2.00 km without royality (S I No 253) |
| 11 | Sand filling in plinth including supply of all material, labour and T&P etc.(SI No 255) |
| 12 | Mild Steel or iron work of fabrication of door and window frame i/c cost of hinges and supply of steel and wastage etc all complete.( S.I.No 502(b)) |
| 13 | 12 mm thick plaster with cement and fine sand mortar in 1:6 on rough face of 9\\" thick walls i/c supply of all material labour and T& P etc required for proper completion of the work.( S.I.No 586+596) |
| 14 | Making groving in plaster including all labour material , T&P etc required for proper completion of work.( S.I.No13.76) |
| 15 | P/A plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface eve and smooth complete. |
| 16 | 40 mm thick PCC floaring in 1:2:4 cement,coarse sand and stone gritt with neat cement finished including supply of all labour , material T&P etc over 1:4:8 cement , fine sand and 40 mm brick ballast 3\\" thick including all completion of work.(As per S.I.No 601) DSR 11.3.1(614.20) |
| 17 | 30mm thick flush doors commercially a quality confirming to IS 2002 Part 1983 i/c fixing of wooden cleats and stoppers and i/c fixingand adjustment of hinge bolt locks handle spring fitting with necessary screw to be supplied Ch 09 Si.no.01 DSR 9.21.2 |
| 18 | Oxidized iron fitting i/c supply of all labour material T&P etc completion of the work |
| 19 | Two coat oil bond distemper of approvrd quality as per direction Engineer-in-Charge(Ch no 15 S.I.No 02) |
| 20 | Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67lit/10sqm over and i/c base coat of water proofing cement paint applied @ 2.20kg/10sqm.( S.I.13.46.1) |
| 21 | Painting first coat over priming coat i/c priming coat on wood or steel and other metel surface with superior synthrtic enamel standard brushing to give an even shade and finish and i/c cleaning the surface off all dust and oother foreign matter sand papering and stripping i/c cost of all materials ,labour T&P etc requiredfor the proper completion of work.( S.I.No 13.48.2+13.50.1 |
| 22 | Painting first coat over priming coat i/c priming coat on steel and other metel surface with superior synthrtic enamel standard brushing to give an even shade and finish and i/c cleaning the surface off all dust and oother foreign matter sand papering and stripping i/c cost of all materials ,labour T&P etc requiredfor the proper completion of work.( S.I.No 13.48.2+13.50.1+13.57.1 |
| 23 | Plain cement concrete work with 1:2:4 cement ,c/sand and 20mm stone gritt in Hold Fast including all labour material T&P etc all completion work Ch-5, S.I.No 6 |
| 24 | Providing and laying vitrified floor tiles with lean concrete of 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) and 75mm base concrete 1:4:8 jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.ch-14 S.No. 21 |
| 25 | Supply and fixing of Fan Boxes i/c all labour T&P etc complete.(S.I.No1149) |
| 26 | Wiring point for light with 1.5 Sq mm F.R.P.V.C.insul multistrend single core copper conductor in P.V.C. conduct pipe concealed in the wall .(S.I.No-131 C) |
| 27 | Wiring point for plug with 1.5 Sq mm F.R.P.V.C.insul multistrend single core copper conductor in P.V.C. conduct pipe concealed in the wall .(S.I.No-134 C) |
| 28 | Wiring point for fan/fresh air fan with 1.5 Sq mm F.R.P.V.C.insul multistrend single core copper conductor in P.V.C. conduct pipe concealed in the wall .(S.I.No-133 C) |
| 29 | S/F of fan regulator dimmer 300/400 watt ISI marked on existing switch board making connection (S.I.No. 1203 A) |
| 30 | S/F surface/flush mountaing 4 ways SPN distribution boards without MCB complete in all respect as direction at site by engineer-incharge(1022 CAT B) |
| 31 | S&F of 6 amp to 32 amp MCB (10KA)c curve .(S.I,No 1002 CAT B) |
| 32 | P/F 2.5 mm Sub-mains with two no. in 20mm dia heavy duty (2mm thick) PVC conduit with 1 no 1.5 Sq mm frlsh PVC insulated 1100 V grade multstrained single core copper conductor as EARTH continuty wire.(As per P.W.D.S.I.No.1304[C]) |
| 33 | S/F of sign boardincluding all chrages. |
| 34 | ADD GST 18 PERCENT Please Enable Macros to View BoQ information |