| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Certain repairs to roof treatment, sunken, roof sheet and ceiling at zone A and zone B under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs as directed by Engr-in-Charge |
| 3 | Demolition of mud in roof any thickness including plastering & leeping removed as directed by Engr-in-Charge |
| 4 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with water proofing compound as directed by Engr-in-Charge |
| 5 | Supply only integral water proofing compound. |
| 6 | Preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps as in sunken and roof slab (overlaps should not be less than 10 cm) complete all as specified and directed. |
| 7 | M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:3 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of complete all as specified and directed. |
| 8 | - ditto - all as per item no 06 above but except brick tiles including cleaning of cement mortar complete all as specified and directed by Engineer-in-charge. |
| 9 | M&L for 75 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in PCC padding over roof slab complete all complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | M&L for cement concrete type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs, rounded or chamfered edges complete all as specified and directed by Engineer-in-charge. |
| 11 | Taking down cement plaster on brick work or concrete surfaces incl racking out joints complete all as specified and directed |
| 12 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed |
| 13 | M&L for 15mm thick rendering on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 with water proofing compound finished fair and smooth complete all as specified and as directed.Note: water proofing compound shall be measured seprately complete all as specified and directed. |
| 14 | M&L for preparation of plastered and unplastered surfaces of wall and applying two coats of oil bound distemper over 3mm wall care putty complete all as spedifed and directed by Engr-in-Charge. Note:- OBD to be done by Roller. |
| 15 | M&L for preparation of plastered and unplastered surfaces of wall and applying two coats of exterior emulsion/ weather proof paint complete all as specified and directed by Engr-in-charge. |
| 16 | M&L for 5mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in ceiling etc complete all as specified and directed. |
| 17 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distermper over a coat 2mm thick birla white putty complete all as specified and directed by Engr-in-Charge |
| 18 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 19 | S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 20 | S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 21 | Demolition of brick / block masonry built in cement mortar including all quoins, arches, pillars etc and clearing off the premises complete all as specified and directed by Engr-in-Charge |
| 22 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 23 | S&F of steel work in tubular trusses, rafters and posts etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 (grade st-240) complete all as specified and directed. |
| 24 | S&F of plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed. |
| 25 | M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over red oxide primer complete all as specified and directed |
| 26 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards etc any thickness . |
| 27 | S&F of PVC hollow panelling consisting of PVC profile 250mm wide and 6mm thick reinforced with PVC linining 10mm C/c.The false ceiling panels shall be fixed & supported onto the steel framework consisting of MS Painted L/T Sections.The false ceiling shall be fixed to the structural steel framework of shelters using cleats & nuts/bolts. The size of 1 angle will be 40 x 40 x 5mm & the size of T will be 65 x 65 x 6mm. The Joints all around the wall panels & false ceiling shall be joined & covered by means of PPGL flashing of size 50 x 50 x 0.50mm fixed using pop rivets at a minimum distance of 200mm. All the false ceiling joints shall be sealed with transparent/white color silicon sealant. The false ceiling panels will have a tongue and groove arrangement, all as speciifed and directed by Eng-in-Charge. |
| 28 | S&F of PVC hollow wall panelling consisting of PVC profile 250mm wide and 6mm thick reinforced with PVC linining 10mm c/c with interlocking arrangement fixed to wall with PVC rowl plugs and steel screws 40cm c/c vertically by drilling holes fixing to walls of reqd height fixed with PVC cassing and capping for top and corner portion of panneling fixed complete all as specified and as directed by Engineer-in-Charge. |
| 29 | M&L for cleaning the surface and made free of vegetation, dirt, foreign particles, liatance all as specified and directed. |
| 30 | M&L for rendering 10mm thick on brick or concrete surface in cement mortar 1:3 with water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge Note:- Water proofing compund to be measured and paid seprately. |
| 31 | Supply and apply high build elastomeric waterproofing coated based on pure hydrophobic polyurethane cold applied or spray, brush applied, membrane with an elongation of 280 % and tensile strength of 2.7N/mm2 as per ASTMD 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure, minimum 88% solid content. The system includes final base preparation, epoxy primer application with 100% water dilution and pure polyurethane application in two coats with minimum consumption of 1.2 kg/sqm complete all as specified and directed by Eng-in-Charge. |
| 32 | M&L for providing GI pipe 40mm light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed by Eng-in-Charge. |
| 33 | M&L for PCC (1:5:10) type E2 using 40mm graded aggregate thick as in sub base complete all as specified and directed by Engineer-in-charge. |
| 34 | M&L for PCC type B-0 (1:2:4) (12.5mm stone graded aggregate), 40 mm thick as for receiving top finishing layer of ceramic tiles for sunken portion finished even and smooth without using extra cement etc complete all as specified and directed. |
| 35 | Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 36 | Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as specified and directed by Engineer-in-Charge. |
| 37 | S&F of CPVC pipes CPVC pipe outer dia 16mm, SDR 11 and plain CPVC SDR 11 fittings complete all as specified and directed by Eng-in-Charge.. |
| 38 | Taking down GI tubing & connection 20mm dia laid in floor / trenches or fixed to walls complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F of CPVC pipes CPVC pipe outer dia 20mm, SDR 11 and plainCPVC SDR 11 fittings complete all as specified and directed by Eng-in-Charge.. |
| 40 | S&F in repairs 15 mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete. |
| 41 | S&F in repairs 15mm dia stop/angle valve, CP cast copper alloy with crutch or butterfly handle crewed down high pressure, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 42 | S&F in repairs vitreous china squatting pan orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests complete fixed in repairs with P or S trap, PVC flushing cistern low level of 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc;complete all as specified and directed. |
| 43 | S&F in repairs vitreous china wash down water closet pan with plastic closet seat cover closed pattern with flat bottom and cover and mild steel chromium plated hinging divice (excluding flusing cistern and flush pipe) in repairs complete all as specified and directed by Eng-in-Charge. |
| 44 | S&F in repairs PVC(SWR) floor trap with grating and diameter of outlet 75mm including jointing to waste pipe fixed with solvent cement complete all as specified and directed. |
| 45 | S&F in repairs fancy type chromium plated stop valves with long shank and cup (concealed type) cast copper alloy screweddown high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore fof size 15mm. |
| 46 | S&F in repairs shower rose 100mm with CP arm of chromium plated any colour or fixing with 15mm pipe (minimum weight 40gm) complete all as specified and directed. |
| 47 | Cutting chases pinning in brick/stone/blocks masonary in making good to facings where required and pointing in cement mortar (1:3) to ends or eges of steps, cills, sun shades, shelves, lintel etc and cutting chases for concealed water tubing or etc and making good complete all as specified and directed. |
| 48 | Taking down rainwater pipes including all fittings as specified and directed. |
| 49 | Dismantling of cast iron pipe any diameter jointed with cement mortar or lead incl all fittings from wall or floors as specified and directed. |
| 50 | S&F of 75 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge. |
| 51 | S&F of 75 mm PVC (SWR) pipes in repair single socketed in any length laid in floor complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F of 75 mm PVC (SWR) bend complete all as specified and directed by Engineer-in-Charge. |
| 53 | S&F of 75 PVC (SWR) junction single,(single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F of 110 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F of 110 mm PVC (SWR) bend with complete all as specified and directed by Engineer-in-Charge. |
| 56 | S&F of 75mm PVC(SWR) vent cowl complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F in repair rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), ISI marked,white coloured, hoisted & fixed in position , capacity 500 litres, including dismantling of unserviceable tank and removing from site complete all as specified and directed. |
| 58 | S&F of gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 20mm fixed in repairs |
| 59 | S&F of gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 15mm fixed in repairs |
| 60 | S&F in repairs ball valves 20mm high pressure of PTMT with epoxy coated aluminium rod and high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms) |
| 61 | M&L for glazed ceramic coloured tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry pointed in white or colour cement to match the colour,with 10 mm thick rendering on fair faces of brick work in cement mortar(1:4) complete all as specified and directed by Eng in Charge. |
| 62 | M&L for non skid ceramic tiles coloured tiles 7-8 mm thick (square/rectangular) polished, area of each tile exe 0.11sqm not exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed by Eng in Charge. |
| 63 | S&F of plain, aluminium sheeting, alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) of 0.56 thickness complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F of bonded mineral wool blanket slab made from glass density 24 kg/cum and fixed as per manufacturer’s instructions, 40mm thick complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |