| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 2 | Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers andcantilevers with wooden plank |
| 9 | Centering shuttering including struttings, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for:Columns, Pillars, Piers, Abutments, Posts and Struts withwooden plank |
| 11 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | 12 mm cement plaster of mix : In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 13 | 12 mm cement plaster of mix : In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) including Neat cement punning |
| 14 | 6 mm cement plaster of mix : Cement mortar 1:3 (1 cement : 3 fine sand) |
| 15 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge. |
| 16 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the jointswith white cement and matching pigment etc. all complete as per direction of the Engineer in-charge. Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles 300 mm x 300 mm in all shades and designs |
| 17 | Providing and fixing plain Multipurpose Cement board (High Pressure steam cured) as per IS : 14862 : 2000 with suitable screws for fibre cement board in ceiling etc. complete as per direction of Engineer-in charge. (frame work to be paid separately) : 6 mm thick cement board |
| 18 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture |
| 20 | Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge. 0.40mm thickness |
| 21 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 22 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer in charge. (Glazing and paneling and dash fasteners to be paid for separately) :- For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 23 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 24 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- With float glass panes of 4.0 mm thickness ( weight notless than 10.0 kg / sqm ) |
| 25 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 26 | 30mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a UPVC profile section of size 30mm x 60mm and wall thickness 2mm ± 0.2mm with inbuilt decorative moulding edging on one side. The styles and rails with plastic brackets of size 75×220 mm mitred and welded at the corners. The styles of the shutter reinforced by inserting galvanised MS tube of size 25×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of \\"H\\" Section, a UPVC profile section of size 30×100 mm and 2 mm ± 0.2 mm wall thickness welded to the shutter style with a UPVC profile section single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness with 20 mm panel beading of suitable size/Glass (4 mm thick plain glass)/ louver section, louver frame of suitable size, complete as per manufacturer's specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 27 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm,made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19×19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame . The door frame to be fixed to the wall usuing MSscrews of 65/100 mm size complete as per manufacturers' specification and direction of Engineer-In-Charge. |
| 28 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Karai wood |
| 29 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge. Gamair Wood 30 mm thick shutters |
| 30 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : Local Teak Wood |
| 31 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with6 mm thick hard board backing :Rectangular shape 453x357mm |
| 32 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 33 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc.complete. |
| 34 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 35 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia |
| 36 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 37 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
| 38 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete : 25 mm nominal bore |
| 39 | Providing and fixing brass stop cock of approvedquality : 15 mm nominal bore |
| 40 | Providing and fixing brass bib cock of approvedquality : 15 mm nominal bore |
| 41 | Providing and fixing PTMT pillar cock of approved quality and colour . 15mm nominal bore, 107mm long, weighing not less than 110 grams |
| 42 | Providing and fixing unplastisised P.V.C. Connection pipe with PTMT Nuts of approved quality and colour.15 mm nominal bore with 45 cm length. |
| 43 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good the walls and floorswherever required : White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 44 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushingcistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 45 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern. |
| 46 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 75 mm OD |
| 47 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 110 mm OD |
| 48 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler 75mm |
| 49 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler 110mm |
| 50 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler (b)Bend 87.5\\" 75mm |
| 51 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler (b)Bend 87.5\\" 110mm |
| 52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler (c) Single equal tee without door 75x75x75 mm |
| 53 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler (c) Single equal tee without door 110x110x110 mm |
| 54 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler (d) Single equal tee with door 75x75x75 mm |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Coupler (d) Single equal tee with door 110x110x110 mm |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work.25 mm nominal outer dia .Pipes. |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm nominal outer dia .Pipes. |
| 58 | Providing and laying 1st class quality vitrified floor tiles different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% nad conmming to IS: 15622-2017 of approved make in all colours and shades laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc all complete as per direction of the Engineer-in-charge. soluble salt stainfree vitrified tiles (Glossy) |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm dia. nominal outer dia .Pipes. Please Enable Macros to View BoQ information |