| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item B) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 5 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 6 | Providing P.C.C.M - 100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade III (50mm to 25mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 7 | Providing P.C.C.M - 75 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 8 | providing and laying damp- proof course 50mm thick with cement concrete 1:2:4 (1 cement :2 coarse sand (zone-lll) :4 grade stone aggregate 20mm nominal size). |
| 9 | providing and laying in position specified grade of reinforced cement concrete ,excluding the cost of centering ,shuttering, finishing and reinforcement - All work up plinth level. 1:1.5.3 (1 cement :1.5 coarse sand (zone-lll): 3 graded stone aggregate 20mmnominal size) |
| 10 | reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landing, balconies , shelves , chajjas , lintels , bands, plain windows sills, staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering , finishing and reinforcement, with 1:1:5:3 (1 cement :1.5 coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size ) |
| 11 | reinforced cement concrete work in walls (any thickness), including attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers , abutments, posts and struts etc. above plinth level up to floor five level , excluding costo of centering, shuttering , finishing and reinforcement:1:1:5:3 (1 cement :1.5 coarse sand(zone-lll) :3 graded stone aggregate 20mm nomimal size) |
| 12 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500) |
| 13 | 8mm, (TMT,Coil Fe 500) |
| 14 | 10mm (TMT,Coil Fe 500) |
| 15 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500) 12mm, 16mm (TMT,Coil Fe 500) |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, fotting, bases of columns, etc. for mass concrete |
| 17 | Suspended Floors, roofs, landings, balconies and access platform |
| 18 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 19 | Column, Pillars, Piers, Abutments, Posts and struts |
| 20 | Stairs, (Excluding landings) except spiral-staircases |
| 21 | Weather shade, Chajjas, corbels etc. including edges |
| 22 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 23 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. |
| 25 | Providing and fixing 1mm thick M.S. sheet doors, windows and ventilators with angle iron frames of mild steel Angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge. |
| 26 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 27 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 28 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 29 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) |
| 30 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 31 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.) |
| 32 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 33 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 34 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 35 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour Tiles. |
| 36 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 : 4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. Size of Tile 1200 x 1200 mm |
| 37 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1 . 8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 38 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 39 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 40 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 41 | Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:- |
| 42 | Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent. |
| 43 | Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 44 | 1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured. |
| 45 | 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical |
| 46 | Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370) |
| 47 | Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" |
| 48 | Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years. |
| 49 | Covering of treated surface with PCC : Providing 50 mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with admixture of integral water proffing and placing in position, skirting curing, taxes and royalty all complete as per building specification and direction of E/I. Panels that has been left should be casted next day. there should be 6mm gap between Panels Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X421 ic Dr. Fixit Pidiproof LW+ |
| 50 | Providing and filling of 6mm thick Groove between 50mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of E/I. (with 18% GST) Brand - Sika-Polysulphide, Forsoc-thioflex 600, Dr. Fixit Pidiseal PS (42P, MYK Seal PS or Equivalent. |
| 51 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 52 | Making plith protection 50mm thick of cement concrete 1:3:6 (1 Cement : 3 coase sand ( zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 53 | Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. |
| 54 | Providing designation 75B brick work in CM (1:6) in Foundation with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 55 | Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I. |
| 56 | Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 57 | Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per building specification and direction of E/I |
| 58 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight ofthe cover to be not less than 58 kg |
| 59 | Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 60 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 61 | Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 62 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 63 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 64 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 65 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 66 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 67 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and Tiron guide at the top and bottom respectively, including applying a priming coat of approved steel primer |
| 68 | Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I. |
| 69 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, complete as the direction of Engineer -in-Charge. |
| 70 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick |
| 71 | Extra for covering top of membrane with Geotextile, 120 gsm nonwoven, 100% polyester of thickness 1 to 1.25 mm bonded to themembrane with intermittent touch by heating the membrane by ButaneTorch as per manufactures recommendation. |
| 72 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 73 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 74 | Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 75 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 76 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1 : 4 (1 cement: 4 coarse sand). |
| 77 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 78 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 1 2 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 79 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 80 | Ridges plain (500 - 600mm) |
| 81 | Flashings/ Aprons.( Upto 600 mm) |
| 82 | Gutter (600 mm over all girth) |
| 83 | Supplying, fitting and fixing 20mm dia M.S. Bar 1 meter long holding down bolt with nuts washers 100 X100 X6mm plate fitted and fixed with cement concrete (1:24) as per approved design all complete as per building specification and direction of E/I. |
| 84 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,including cutting,hosting, fixing in position and applying a priming coat of approved steel primer all complete.r |
| 85 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size) |
| 86 | Extra for providing and fixing 30X4mm glass strips in joints of flooring , complete job as per specification and direction of E/I. |
| 87 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 88 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 89 | Angle Size (ii) 65x65x6/8/10 (Gr.A) |
| 90 | Drilling 6mm dia hole M.S. angle iron for fixing of staples etc. as per building specification and direction of E/I. |
| 91 | Labour for cutting of M.S. angle iron post to required length, one end splitted as fishtailed in a length of 150mm complete as per building specification and direction of E/I. |
| 92 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-InCharge |
| 93 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 94 | Rough dressing the trenched ground including breaking clods. |
| 95 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation |
| 96 | Fine dressing of the ground. |
| 97 | Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). |
| 98 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 99 | Mixing earth and sludge or manure in the required proportion specified ordirected by the Officer-in-charge |
| 100 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60 mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge |
| 101 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. |
| 102 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 103 | Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. |
| 104 | Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm ht., in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge. |
| 105 | Providing and Displaying Travelers palm well developed with fresh & healthy leaves foliage 210 to 240 cm ht specimen in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 106 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 107 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 108 | Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50 m : Common burnt clay F.P.S (non modular) bricks of Class designation 7.5 |
| 109 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water |
| 110 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge |
| 111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. |
| 112 | 15 mm nominal dia Pipes |
| 113 | 32 mm nominal dia Pipes |
| 114 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 115 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 116 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 117 | Providing P.C.C. M-200 in foundation with nominal mix of (1:1.5:3) with approved quality of stone metal 50 mm to 40 mm size graded and local river sand (washed and screened) including shuttering, screening, mixing cement concrete in mixer and placing in position, vibrating, striking, curing taxes and royalty all complete as per building specification and direction of E/l. |
| 118 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l. |
| 119 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25. |
| 120 | Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l |
| 121 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes. |
| 122 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) |
| 123 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete |
| 124 | Rolling with smootyh wheeled roller all complete as per direction of E/I. |
| 125 | Supplying and laying (properly as per design and drawing) rip-rap with good quality of boulders duly packed including the cost of materials,royalty all taxes etc.but excluding the cost of carriage all complete as per specification and direction of E/I. |
| 126 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 127 | Bricks - 8km (1k + 7p) |
| 128 | Sand - 30km |
| 129 | Chips -20km |
| 130 | Metal - 20km |
| 131 | Fly Ash Brick - 15km |
| 132 | Carrage of Earth -1 km |
| 133 | Boulder (22km) |
| 134 | Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. Group C |
| 135 | Supplying and fixing batten/ angle holder including connection etc. as required. |
| 136 | 9/10 Watt LED Bulb |
| 137 | S.I.T.C of following rating recess/surface mounting round/square shape downlight with pressure die cast housing for single phase supply voltage. Luminaire shall conform to IS:3022 part-5/ section-5 or IEC:62722 with all necessary accesories as required. 80W LED Flood light |
| 138 | S.I.T.C of following rating surface mounted LED tube lightfitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20w/22w LED tube |
| 139 | 12\\" (300mm) Exhaust fan |
| 140 | 16\\" (400mm) Wall fan |
| 141 | Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of he above fan making good the damage, connection, testing, commisionig etc as required. |
| 142 | S/F Modular type electronic fan regulator :- Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 143 | Supply, fitting, fixing and testing of 1200mm Sweep, BLDC, 5Star Fan.32 W |
| 144 | S/F light plug point with modular type accessories :- Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required. |
| 145 | S/F light plug point with modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 146 | S/F 20amps SPN MCB industrial Socket:- Supplying and fixing 20 amps 240V, SPN industrial socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP MCB insheet steel enclosure on surace or in recess with chained metal cover for the socket outlet and complete with connections, testing & commissioning etc. |
| 147 | Supplying and fixing following size/ modules G.I. box along with modular base & cover plate for modular switches in recess etc as required. |
| 148 | 4 module (78mm x 140mm x 50mm) |
| 149 | 12 module (135mm x 205mm x 60mm) |
| 150 | S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required. |
| 151 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit. |
| 152 | 4 X 16 sq. mm + 2 x 6 sq.mm Earth Wire |
| 153 | 4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire |
| 154 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit. |
| 155 | 2 X 4 sq. mm + 1 x 4 sq.mm Earth Wire (Sockets) |
| 156 | 2 X 2.5 sq. mm + 1 x 2.5 sq.mm Earth Wire (Switch Boards) |
| 157 | Copper earth pipe electrode :- Earthing with G.I. earth pipe 4.5mtr. long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required. |
| 158 | P/F 25mm x 5mm copper earth strip in surface/ recess :- Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc., as required. |
| 159 | S/L 25 mm x 5 mm G.I. earth strip in ground :- Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including soldering etc. |
| 160 | P/F G.I. lightning conductor finial :- Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 161 | G.I. earth plate electrode :- Earthing with G.I. earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 162 | P/ F G.I. Lightning conductor tape in horizontal run :- Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (horizontal run). |
| 163 | Providing and fixing G.I tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (vertical run). |
| 164 | Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 165 | Supply of following sizes and core PVC/XLPE insulated, PVC sheathed armoured electrical cable with aluminium conductor for working voltage upto 1.1 KV etc as required. |
| 166 | 3.5c x 95 sq.mm |
| 167 | 3.5c x 70 sq.mm |
| 168 | Laying of one nùmber PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 169 | 1.1 KV Cable End Termination:- Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. |
| 170 | 3.5c x 95 sq.mm (45mm) |
| 171 | 3.5c x 70 sq.mm (38mm) |
| 172 | Supplying and fixing following way three pole & neutral ,sheet steel, MCB distribution board, 415 volts, onsurface /recess, complete with tinned copper bus bar, neutral bus-bar, earthbar ,dinbar, interconnections, powder painted including earthing etc. as required. |
| 173 | 6 Way (4+18) Double Door, Horizontal type |
| 174 | 8 Way (4+24) Double Door, Horizontal type |
| 175 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10kA 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required. |
| 176 | 63A rating, TPN MCB, \\"C\\" curve 10 KA breaking capacity. |
| 177 | 40A rating, TPN MCB, \\"C\\" curve 10 KA breaking capacity. |
| 178 | 6/32A rating, SPN MCB, \\"C\\" curve 10 KA breaking capacity. |
| 179 | Supplying and fixing following rating four pole, (three phase and neutral) 415 volts, residual circuit breaker (RCCB) having a sensitivity current 30 milli amperes in the existing MCB DB complete with connection, testing & commissioning etc. as required. |
| 180 | 25 amps |
| 181 | 40 amps |
| 182 | Point wiring in PVC conduit, with piano type switch :- Wiring for light point/fan point/exhaust fan point/call bell point, with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, piano type switch,phenolic laminated sheet with suitable size PVC/MS box etc as required Group A |
| 183 | Power plug wiring in PVC conduit (2 x 4 sq. mm) :- Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required. |
| 184 | Circuit/ submain wiring in PVC conduit :-Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required |
| 185 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 186 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 187 | 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire |
| 188 | Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 189 | 3x1.5 sq mm |
| 190 | 3x2.5 sq mm |
| 191 | S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. |
| 192 | 72mm x 146mm x 48mm deep/(4\\" x 7\\") |
| 193 | 147mm x 93mm x 47mm deep/(5\\" x 7\\") |
| 194 | 72mm x 226mm x 48mm deep/(4\\" x 10\\") |
| 195 | S/F piano type switch/socket - Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required. |
| 196 | 5/6 amps, one way switch |
| 197 | 15/16 amps, one way switch |
| 198 | 3 pin 5/6 amps, socket outlet |
| 199 | 6 pin15/16 amps, socket outlet |
| 200 | Electronic step fan regulator, mini |
| 201 | S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 202 | S/F rewireable double pole/ TP&N switch disconnector :-Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required. 32 amps, double pole |
| 203 | S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Single door |
| 204 | S/F 'B' series, S.P. MCB :- Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. 6/32 amps, single Pole, \\"B\\" series |
| 205 | Ceiling fan 48\\"( 1200mm) |
| 206 | S.I.T.C of following rating LED floodlight fitting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminaire shall conform to IS:3022 part-5/ section-5 or IEC:62722 with all necessary accesories as required. 150W LED Flood light |
| 207 | MAIN LT PANEL FOR SCHOOL CAMPUS Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Indoor Type Main Distribution Board fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing , dust and vermin proof, (degree of protection-IP54)with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) as per Specification. |
| 208 | The Main LT Panel shall broadly comprise of the following equipment/components) Incoming Feeders:- Incomer-160A, TPN MCCB (P-2), 35 kA for 1 sec (Ics=100%Icu) Breaking capacity (Variable thermal rating 80-100%, variable magnetic rating 6-10 times) with factory made silver plated copper spreading links- 3 Nos. (AC Mains + DG I/C + Changeover) Outgoing Feeders:- 125A TPN MCCB 16kA - 01 No. 63A TPN MCCB 16kA - 02 Nos. 200A TPN Copper bus bar in metal encolsure with fixing clamps Indication lamps(On- Off Trip Power On -- RYB) Supplying, Installing, Testing & Commisioning cost of Main LT Panel for School Campus all complete with all necessary items as per direction of E/I. |
| 209 | MAIN LT PANEL FOR G+2 SCHOOL BUILDING Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Indoor Type Main Distribution Board fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing , dust and vermin proof, (degree of protection-IP54)with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) as per Specification. |
| 210 | The Main LT Panel shall broadly comprise of the following equipment/components) Incoming Feeders:- Incomer-160A, TPN MCCB (P-2), 35 kA for 1 sec (Ics=100%Icu) Breaking capacity (Variable thermal rating 80-100%, variable magnetic rating 6-10 times) with factory made silver plated copper spreading links- 1 No. Outgoing Feeders:- 40A TPN MCB 10kA - 04 Nos. 63A TPN MCB 10kA - 04 Nos. 63A TPN MCCB 16kA - 01 Nos. 200A TPN Copper bus bar in metal encolsure with fixing clamps Indication lamps(On- Off Trip Power On -- RYB) Supplying, Installing, Testing & Commisioning cost of Main LT Panel for G+2 School Building all complete with all necessary items as per direction of E/I. |
| 211 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) 580 mm long (c) with 10 lit. low level P.V.C. cistern |
| 212 | Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 : 15 mm nominal bore |
| 213 | Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.:15 mm nominal bore. |
| 214 | Providing and fixing PTMT Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, Weighing not less then 106 gms. |
| 215 | Providing and fixing C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms |
| 216 | Supplying, fitting and fixing Mirror of 6 mm thick plate glass bevelled edge mirror including CP brass revolving fittings 3 mm ply wood board and CP hings to fix with mirror . 450 mm x 300 mm size . |
| 217 | Supplying, fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Brackets 32 mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 gm, 32 mm PVC waste pipe 750 mm long with brass coupling at one end making plumber joints etc.all complete as per specification and direction of E/I . |
| 218 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.) |
| 219 | 15 mm dia |
| 220 | 20 mm dia |
| 221 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 222 | 25 mm dia |
| 223 | 32 mm dia. |
| 224 | 40mm dia |
| 225 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 226 | Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I. |
| 227 | Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings. |
| 228 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 229 | Supplying, fitting and fixing CP brass towel rail 20 mm x 600 mm with bracket container |
| 230 | Providing and fixing c.p. towel ring complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Mark or equipment) |
| 231 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole |
| 232 | Providing and fixing NP/CP brass/PVC Porcelain shower rose of 15 mm inlet etc. All complete as per specification and direction of E/I. 150 mm dia PVC shower |
| 233 | provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc. |
| 234 | provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc. |
| 235 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 236 | 75 mm |
| 237 | 110 mm |
| 238 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 239 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. |
| 240 | 75 mm Coupler |
| 241 | 110 mm Coupler |
| 242 | 75 mm Single pushfit Coupler |
| 243 | 110 mm Single pushfit Coupler |
| 244 | 75 mm Single tee with door |
| 245 | 110 mm Single tee with door |
| 246 | 75 mm Single tee without door |
| 247 | 110 mm Single tee without door |
| 248 | 75 mm Bend 87.5° |
| 249 | 110 mm Bend 87.5° |
| 250 | 75 mm Shoe (Plain) |
| 251 | 110 mm Shoe (Plain) |
| 252 | Supplying, fitting and fixing Bathroom Fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 10% for labour and Contractors profit) |
| 253 | Bib cock - long thread |
| 254 | Angular stop cock L.T. |
| 255 | Soap Dish |
| 256 | 32mm dia. PVC waste pipe 750mm long with cushion |
| 257 | 15mm C.P. nipple with coupling |
| 258 | Steel jali - 100mm dia. |
| 259 | Add 18 % GST |
| 260 | Add 1% Labour Cess Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail