| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (I) R&D CHANDIPUR Name of Work: Repair/maint to Roof treatment, joinery, Plumbing and certain allied works at certain Md accn under AGE B/R-I Chandipur and Repair/replacement of point wiring, sub main wiring (Modular/ Conventional), DB,s panel and MCCBs/MCBs, LED light fittings, security lights, earthing, and allied works at Md Accn at Prakash Nagar,Mohan Nagar, and officers accn at PXE under AGE E/M Chandipur Contract No: GE(I)R&D/BLS/ 2026-27 Bidder Name : SCHEDULE 'A' (BOQ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Work / Item Item Code / Make Number or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE (including all Taxes as specified in tender Documents) In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down cement plaster any description and the like on brick or stone walls, etc including raking out joints,hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 3 | M & L for 5 mm thick rendering in CM 1:3 on ceiling finished even and smooth on wall complete all as specified and directed. |
| 4 | M & L for 10 mm thick rendering in CM 1:6 on brick or concrete surfaces finished even and smooth on wall complete all as specified and directed. |
| 5 | M & L for 15 mm thick rendering in CM 1:4 on brick or concrete surfaces finished even and smooth with integral water proofing compound (IWPC Measured and paid seperately) on wall complete all as specified and directed. |
| 6 | M & L for preparation of newly plastered / unplastered surfaces of ceiling surfaces and applying two coats of white wash complete all as specified and as directed. |
| 7 | M & L for preparation of newly plastered / unplastered surfaces of walls and two coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed. |
| 8 | Preparation of new plaster surface of wall and applying two coats of Premium Acrylic Smooth exterior paint with Silicone additives of required shade@ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed. |
| 9 | Supply only integral liquid water proofing compound |
| 10 | M & L for taking down/demolition of existing WPT with screed concrete of any description including old PCC padding, surkhi etc. roughening surfaces of old/mother concrete floors / slabs and washing down with water to remove dust/debries particles complete including preparation of surface to receive plastering and removal of debries outside MD land complete as per direction of Engineer-in-Charge. |
| 11 | M&L for 40mm thick PCC 1:2:4 type B-1( using 20 mm graded stone aggregate), in floor and steps, landing etc. including finishing the surface even and smooth without using extra cement complete all as specified & directed. |
| 12 | M & L Rendering 10 mm thick cement plaster in CM 1:4 on roof surface with WPC complete all as specified and directed. |
| 13 | M & L for roof treatment using APP based polymeric membrane minimum weight 3.5 kg/sqm and 3 mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/sqm) over a coat of primed and bonding surface by forced application, including taking down old felt complete all as specified and directed by Eng-in-charge. |
| 14 | M&L for preparation of new surface and Painting one coat with aluminium paint of approved brand and manufacture to give an even shade on new surface of APP membrane and rolling shutter etc complete all as specified and directed. |
| 15 | Taking down MS cover over rolling shutter, removing dust shutter steps, cleaning of shaft, springs, crankshaft, gear aggangement and cleaning of all accessories with lub old and greesing and refixing same position. |
| 16 | Taking down Chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters and grill from the frames) complete all as specified and directed. |
| 17 | Taking down Chowkats or frames exc. 1.50 Sqm but n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 18 | Taking down shutter of any description but exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 19 | Supply and fix powder coated anodised aluminium frame for windows, ventilators with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc. complete all as specified and as directed. |
| 20 | Supply and fix powder coated anodised sliding/hung type aluminium door, window and ventilator shutters (minimum thickness of powder coating 50 micron), without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2Nos) suitable handle (1 No), aluminium tower bolt 100 mm (1No) etc. complete all as specified and as directed. |
| 21 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 22 | M & L for preparation of new steel surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 23 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm) and Area not exceeding 2.00 sqm each. Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass, wire mesh and connected accessories. Net Opening will be measured for payment purpose.) |
| 24 | S & F 5mm thick sheet glass, ordinary quality and glazing with rubber beading around the glass, in squares exc 0.50 sqm in each pane complete all as specified and as directed. |
| 25 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and avergae width of aperture 1.40 mm and fixed with stainless steel wire staples, etc. complete all as specified and as directed. |
| 26 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Rate includes M.S. hold fast/ lugs or SS dash fasteners ). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 27 | -Ditto- as item No. 25.00 above but of Frame size 65x 125 mm |
| 28 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges shall be paid separately) |
| 29 | All as per Item no.27 above but Factory made WPC wire gauzed door shutter 30 mm thick(style).(Note: The unit rate quoted by contractor excludes cost of glass, wire mesh and connected accessories.) |
| 30 | S & F of solid PVC door frame of size 50mmx47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with MS square tube, suppling and fixing in opening complete. |
| 31 | S & F of factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded both side Prelam PVC sheet strip of 20mm width stuck inside with solvent cement for stiles prelam PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of both sidePrelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement. |
| 32 | S & F Stainless steel medium weight, cold rolled mild steel of size 75 mm complete all as specified and directed. |
| 33 | S & F for SS butt hinges medium weight cold rolled mild steel of 100 mm size. complete all as specified and directed . (for wooden doors) |
| 34 | S & F for 150 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed . |
| 35 | S & F for 150 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed . |
| 36 | S & F for 300 mm Sliding door bolt aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 37 | S & F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and avergae width of aperture 1.40 mm and fixed with stainless steel wire staples, etc. complete all as specified and as directed. |
| 38 | S & F in repairs for 300 mm Sliding door bolt aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 39 | S&F in repair 100 mm size mortice lock with two lever (vertical type) brass body and fixed complete all as specified. |
| 40 | S&F in repairs using plywood, grade BWR, type BB 18mm thick fixed with screws to timber framework and similar works etc. complete all as specified. |
| 41 | M&L Decorative type sun mica 0.9mm/1mm thickness type 1,of surface finish,colour and pattern as approved by engr-in-charge, fixed with approved adhesive as per manufactures instructions |
| 42 | M & L 100mm Extruded brass handles, fabricated type polished |
| 43 | S & F 75mm Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed. |
| 44 | Minor repair to aluminum joinery and making serviceable the same by meance of adjustment, greacing as necessary etc all as specified and directed |
| 45 | M & L for preparation of new or previously untreated/old surface of wood of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamelled paint over one coat of pink primer complete all as specified and directed |
| 46 | S&F in repair 100mm long Hasp and Staple, Safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws. |
| 47 | S&F in repairs Stop/concealed stop/angle valves , chromium plated, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed to 15 mm bore pipe complete. |
| 48 | S&F in repairs Bib taps, chromium plated, cast copper alloy screwed down, screwed for iron pipe or for brass ferrule and fixed to 15 mm bore pipe complete. |
| 49 | S&F in repair brass CP 2 in 1 Bib Cock with wall flange complete all as directed. |
| 50 | S&F in repairs Pillar tap(long body type) cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure with or without letter 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for fixing to 15 mm bore pipe complete. |
| 51 | S&F in repair brass CP 2 way angle cock with wall flange complete all as directed. |
| 52 | S&F in repairs Bib tap standard of PTMT any colour high pressure screwed for 15 mm bore dia iron pipe and fixed complete. |
| 53 | S&F in repair Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed. |
| 54 | S&F in repair Angle/ stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. |
| 55 | S & F in repairs Vitreous china wash down water closet pan (pedestal pattern) including 'P' or 'S' Trap with necessary, fixing arrangement including plastic water closet seat cover white with recessed bottom and cover fixed with aluminium hinging device complete all as specified and directed. |
| 56 | .M & L in repair for PVC valve less syphonic action type flushing cistern 10 ltr capacity low level white with inlet ball valve, float flush pipe and handle including bracket ( Prayag/Hindware/Parryware) fixed. |
| 57 | Supply and fix in repair PVC connection 15mm size with PTMT nuts of length 600mm |
| 58 | S & F in repair Vitreous china wash basin with pedestal, white, flat back, size 550 x 400 mm excluding taps, waste pipe, chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets complete all as specified and directed. |
| 59 | S & F in repairs stainless steel sink, 1.00 mm thick for kitchen with plug, waste pipe, washer including cantilever cast iron bracket, connecting union overall size 915 mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm. |
| 60 | S&F in repair shower rose chromium plated 120 mm (minimum) size with swivel joints suitable for 15 mm bore pipe including shower arm chromium plated 15 mm dia, 190 mm (minimum) long with bend of 45 degree complete all as specified and directed. |
| 61 | S & F bevelled edge 6mm thick mirror of selected quality glass with frame fixed with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 62 | S&F Plastic water closet seat cover soft closed white with bottom and cover fixed with aluminium hinging device in repair. |
| 63 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 64 | Dismantling water tanks of any type of capacity exc 250 but n.exc 500 liters and removing to store complete all as specified and directed. |
| 65 | S & F Rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I . |
| 66 | Dismantling water tanks of any type of capacity exc 500 liters but n. exc 1000 ltrs and removing to store complete all as specified and directed. |
| 67 | S & F Rotational moulded polyethylene water storage tanks of 1000 ltrs capacity (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I . |
| 68 | Disconnecting existing 500 Ltr tanks and from mouths of circulating pipes, etc cleaning & removing all scale & dirt etc from existing tanks and mouths of circulating pipes of any description & washing down in the manner as specified and re-fixing in position complete all as specified and directed. |
| 69 | All as per Item 67 above but 1000 Ltr tanks, complete all as specified and directed. |
| 70 | S & F in repair of Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 20 mm bore pipe complete all as specified and directed. |
| 71 | Taking up or down steel tubing 20mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 72 | S&F 20 mm dia UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe with all fittings complete all as specified and as directed by Engr-in-charge. |
| 73 | All as per item 71 above but 25mm dia UPVC pipes complete all as specified and as directed by Engr-in-charge. |
| 74 | S & F for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints, necessary clamps fixed to walls including taking down complete all as specified and directed. |
| 75 | S & F for PVC (SWR) 110 mm bends complete all as specified and directed. |
| 76 | S & F in repair 100 mm dia PVC (SWR & RWP) floor trap plain with grating inclu. jointing with solvent cement of out let dia. |
| 77 | S&F in repairs stainless steel plate rack of size 30\\"x36\\"x10\\" made out of 1mm thick sheet complete all as directed. |
| 78 | Taking down carefully copper/aluminum point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floor, etc. |
| 79 | M&L Point wiring for one light/fan/bell point controlled by one switch using FRLSH grade PVC insulated, unsheathed, stranded copper conductor three run of size 1.5 Sqmm for phase neutral and earth continuity wire to be drawn in and including non metallic rigid PVC conduit concealed in wall including MS sheet metal switch / terminal box 1.2 mm thick upto (200x300)mm size box and beyond that not less than 1.63mm thick with Hylam sheet cover 3.00mm thick including cutting and chassing the wall as per site requirement and making good disturbed surface of walls complete all as specified and directed. |
| 80 | All as per item No.78 above but for One 5 Amps switch socket combination on independent board |
| 81 | All as per item No.78 above but for One 5 Amp Socket on same board |
| 82 | All as per item No. 78 above but for 15/16 Amps switch socket out let independent point by using three run 4.0 Sqmm FRLSH grade, PVC insulated, stranded copper conductor on |
| 83 | All as per item No. 78 above but for 15/16 Amps switch socket out let independent point by using three run 2.5 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor |
| 84 | Supply and fixing including connection of call bell AC 230 Volt single pole |
| 85 | Supply and fixing including connection of bell push switch,flush type 5 Amps, 230 volts. |
| 86 | M&L Point wiring for one light/fan/Bell/Holder point controlled by one switch using FRLSH grade PVC insulated, unsheathed, stranded copper conductor of three run of 1.5 Sqmm for phase neutral and earthing to be drawn in and including PVC casing capping of suitable size incuding MS sheet metal switch / terminal box 1.2 mm thick upto (200x300)mm size box and beyond that not less than 1.63mm thick with Hylam sheet cover 3.00mm thick and making good disturbed surface to walls complete all as specified. |
| 87 | Same as itemNo. 85 above but for 5 Amps switch socket combination on independent board. |
| 88 | Same as item No. 85 above but for one 5 Amps switch socket combination on same board. |
| 89 | All as per item No. 85 above but for 15/16 Amps switch socket out let independent point by using 3 runs of 4.0 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor |
| 90 | All as per item No. 85 above but for 15/16 Amps switch socket out let independent point by using 3 runs of 2.5 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor |
| 91 | S & F in repair Including connection of switch piano, flush button, type single pole one way 5 Amps, |
| 92 | S & F Including connection of switch socket combination 5 Amps 2 in 1 flush type, |
| 93 | S & F Including connection of switch socket combination 5 in 1, 3 pin, 5 and 16 Amps flush type |
| 94 | S & F ceiling rose, polycarbonate three terminals. |
| 95 | S & F Electronic fan regulator, stepped type 120/280V complete all as directed by Engineer-in-Charge. |
| 96 | S & F of , Lamp holder, PVC/Polycarbonate type with back plate. |
| 97 | S & F of , Modular switch 1 way 6A, 1 module |
| 98 | S & F of , Modular switch 1 way 16A, 1 module |
| 99 | S&F of Modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 100 | S & F of Modular Fan step regulator, 120W - 2 module |
| 101 | S & F of ,MODULAR COVER PLATE WITH FRAME 3 module |
| 102 | S & F of ,MODULAR COVER PLATE WITH FRAME 4 module |
| 103 | S & F of ,MODULAR COVER PLATE WITH FRAME 8/12 module |
| 104 | S & F of , Modular Metal flush box 3 module module |
| 105 | S & F of , Modular Metal flush box 4 module module |
| 106 | S & F of , Modular Metal flush box 8/12 module module |
| 107 | Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed by Engineer-in-Charge. |
| 108 | M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, stranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC conduit 25mm dia. (Note: Three runs of 4 Sqmm copper wire and one run of conduit/casing shall be measured as one unit.) |
| 109 | All as per item No-107 but in PVC Casing N Caping |
| 110 | All as per item No. 107 above here in before but 3 runs of 2.5 sqmm |
| 111 | All as per item No-109 but in PVC Casing N Caping |
| 112 | All as per item No. 107 above here in before but 3 runs of 6 sqmm |
| 113 | Same as above item No. 111 but in PVC Casing N Caping |
| 114 | All as per item No. 107 above, but using 4 runs of 6 Sqmm and two run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and inclusing PVC conduit medium grade of size 32 mm dia(Note : Four runs of 6 Sqmm copper wire with two run of 6 Sqmm copper wire and one run of conduit/casing shall be measured as one unit.) |
| 115 | All as per item no 113 but in PVC Casing N Caping |
| 116 | All as per item No. 113 above, but using 4 runs of 10 Sqmm and two run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire |
| 117 | Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc for concealed water tubing or concealed conduit wiring,Fair cutting n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc. including rubbed finish and waste |
| 118 | S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20amp |
| 119 | S & F in repair MCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 240v, fixed in wall including making good disturbed surfaces including taking down old unserviceable , complete all as directed by Engineer-in-Charge. |
| 120 | All as per in Item No. 118 here-in-before but of SPN 8 way,240Volts double door as in repair. |
| 121 | All as per in Item No.118 here-in-before but of SPN 12 way,240Volts double door as in repair. |
| 122 | S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps including taking down old unserviceable one. |
| 123 | All as per item No. 121 above but of capacity 63 Amps, 4 Pole, 16 KA. |
| 124 | S & F in repair MCB, SPN. 32 Amps rating 240, volt, 'C' series, 10 kA, |
| 125 | S & F in repair , MCB, TPN, 415 V, 50Hz, 10kA, 'C' series, 63 Amps series. |
| 126 | S & F in repair , MCB, TP, 415 V, 50Hz, 10kA, 'C' series, 25 to 63 Amps series. |
| 127 | S & F in repair MCB, SP, 6 to 32 Amps, 240 volt, 'B' Series, 10 kA, as in repairs. |
| 128 | S & F in repair MCB, SP, 40 Amps, 240 volt, 'B' Series, 10 kA, as in repairs. |
| 129 | Supply and fix in repair LED batten fitting 4' long of capacity 20 Watt with diffuser complete in channel thermally conductive meterial including PVC insulated flexible copper wire of size .5 sqmm 2 core from ceiling rose to fitting complete incl taking down old fitting all as specified and directed |
| 130 | All as per item Sl No. 128 above here-in-before but 10 Watt, 2' all as specified and directed. |
| 131 | Supply and fix in repair retrofit LED tube rod only of capacity 20 Watt 4' long complete incl taking down old fitting all as specified and directed |
| 132 | Supply & fix LED luminaire 600 mm x 600mm 35/36 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor case of suitable size complete. all as specified and directed by engrs in charge. |
| 133 | Supply & fix LED luminaire 1'x 1' 24 watt squar/round 220 volts AC recessed type with octane LED panel high efficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor case of suitable size complete. all as specified and directed by engrs in charge. |
| 134 | M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item. |
| 135 | S & F in repair Earthing conductor with GI strip of size (25 x 4) mm complete all as directed by Engineer-in-Charge. |
| 136 | Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc and greasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire 1.5m long, including one coat of synthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed by Engineer-in-Charge. (NOTE : Replacement of worn out/ defective/unserviceable parts, flexible copper wire and rewinding shall be measured and paid separately under relevant items of these schedule). |
| 137 | All as per item No. 135 above here-in-before but for Exhaust fans of any size and make. |
| 138 | M&L Rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelled copper wire of adequate size/gauge including all insulation materials, varnishing etc complete all as directed by Engineer-in-Charge. |
| 139 | All as per item No.137 above here-in-before but for exhaust fans of 300/380mm sweep of any make. |
| 140 | Supply only Ball bearing of suitable size for any type/make of ceiling fan, Exhaust Fan, Wall Fan, |
| 141 | Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan. |
| 142 | Supply only capacitor 220 volts,4 mfd suitable for ceiling fan, |
| 143 | Supply only in replacement of existing damage motor of ceiling fan due to bend or wear tear in shaft , damage of armeture laminated sheet or seized of bearing with new cu wounded motor complete set including body hanging rod nut bolt bush etc suitable for 1200 mm ceiling fan with necessery one year warranty in all respect rod complete all as specified and directed. |
| 144 | Supply only in replacement of existing damage ceiling fan blade due to bend , wear and tear with new one 1200 mm long set of three white in colour complete all as specified and directed. |
| 145 | S & F included concealed into a brick wall to flush metal GI Box 1.2 mm thick of suitable size for fixing of 5/15 A Switch Socket combination included necessery hylum sheet with cutting slot for switch, socket, regulator with S S Screw and making good disturbed surface of walls complete all as specified and directed. |
| 146 | S & F in repair 16A, 3 pin plug top complete all as specified and as directed. |
| 147 | S & F included concealed into a brick wall to flush metal GI Box 1.2 mm thick of suitable size for fixing of switch, regulator, socket & Switch Socket combination as an switch board included necessery hylum sheet with cutting slot for switch, socket, regulator and S S Screw and making good disturbed surface of walls complete all as specified and directed. |
| 148 | S&F in repair LED Bldg security light fitting 35 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |