| 1 | SCH 'A' PART-I To XIINote: This schedule is pre-priced by MES and the rate indicated under Col 5 signifies this fact only |
| 2 | Total amount of Sch 'A' Part-I (Building and Structures) |
| 3 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch ‘A’ Part III (Internal Water supply) |
| 5 | Total amount of Sch ‘A’ Part IV (Internal Electric Supply) |
| 6 | Total amount of Sch ‘A’ Part V (Road, Path and Culverts) |
| 7 | Total amount of Sch ‘A’ Part VI (Sewage Disposal) |
| 8 | Total amount of Sch ‘A’ Part VII (Area Drainage) |
| 9 | Total amount of Sch 'A' Part-VIII (External Water Supply) |
| 10 | Total amount of Sch 'A' Part-IX (External Electric Supply) |
| 11 | Total amount of Sch 'A' Part-X (Lightning Protection) |
| 12 | Total amount of Sch 'A' Part-XI (Air Conditioning & Cooling Appliances) |
| 13 | Total amount of Sch 'A' Part-XII (DG Set) |
| 14 | SCHEDULE 'A' PART-XIII (MISCELLANEOUS B/R AND E/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only. |
| 15 | S & F square profile LED lighting fixture with extruded polycorbonate,environmental friendly,energy efficient ready to use pack LED Tube light fitting 20 Watt with LED light source 6500k with uniform light output, with all accessories including its connection complete with all as specified and directed by Engineer-in-charge. |
| 16 | Supply and fixing in factory made powder coated sheet metal enclosure, TPN Vertical Distribution Boards with MCCB as incomer IP43 protection Double Door : Plain 4 way with suitable rated busbar, neutral link, and MCB SP/TP as outgoings complete all as specified and directed. Note :MCCB and MCBs are not included in this item and paid separately. |
| 17 | S&F MCCB 4 Pole, 415 V, adjustable type Thermal Magnetic Release, 100 Amps with breaking capacity 25 KA and making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 18 | M&L for preparation of road surface and applying thermoplastic reflective paint for marking of minimum 2.0 mm thick single coat as a centre line or edge line etc, road marking n exc 100 mm width using thermo plastic paint (Hot application) white/yellow by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter fillers etc, thermoplastic requirement for glass beads shall be confirming to BS-6086 of most specification including spraying of glass beads etc complete all as per manufacturer's instructions and complete as all specified and directed. |
| 19 | M&L for construction of valve pit/chamber of Internal dimensions 900 mm x 900 mm x 900 mm, using PCC 1:4:8, type D-2, using 40mm graded stone aggregates for foundation, 23 cm thick, brick wall built in cement mortar (1:4) ,15 mm thick rendering all around the brick work in cement mortar (1:6), 75 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates in coping including necessary form work, 3 coats of white wash on rendered surfaces and on coping, 5 mm thick mild steel top sheet cover with frame made out of 40x40x6 mm angle iron, locking arrangement, including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. |
| 20 | Cutting existing 80 mm dia pipe for inserting Tee of size 80x80x40 mm including lead joint and excavation etc complete all as specified and directed |
| 21 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 110 mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24, 450 N laid in trenches for cable protection complete, all as specified and as directed. |
| 22 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50 mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24, 450 N laid in trenches for cable protection complete, all as specified and as directed. |
| 23 | Supply, install, testing and commissioning, factory made and tested (including CPRI type test certified) LT panel board out door type, floor mounted, compartmentalised and IP-63 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 300 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with and including following items. (Notes : The rate quoted shall include earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ).Note: Panel board shall be approved by CPRI and certificate to be produced and to be submitted in the office. |
| 24 | incoming:- (a) MCCB 4 P, 415 Volt 200 Amps, 36KA, 50 Hz with fixed thermal and magnetic setting -01 No Outgoing:- (b) MCCB 4 P, 415 Volt 100 Amps, 25KA, 50 Hz -03 Nos. (c) R,Y,B Indicators (d) Multifunction Digital square type intelligent panel meter to measure voltage, current, frequency, & Power factor - 01 No |
| 25 | Supply, install, testing and commissioning of Silent Diesel Engine Generating Set, 125 KVA/100 KW, 1500 RPM, 3 phase, 415 V, 50 HZ, power supply alternator along with fuel tank, control panel., battery and complete set installed in sound acoustic enclosure and standard accessories and fittings with power factor 0.8, PCC foundation suitable for the generator set as per manufacturer's instructions complete with standard accessories and Microprocessor based integrated DG Set controller with coupled to Alternator rated at 125KVA/100 KW at 415 Volts, set mounted on Channel Iron Base Frame complete with sub-base with Batteries, AVM Pads and STD Panel all as per guideline of latest CPCB IV+ norms all as specified and directed and comprising of the following:Make: Kirloskar/Greeves/Cummins |
| 26 | (i) Engine: Engine with direct injection, water cooled, 3 cylinders, in-line,4 Strokes rated at developing 1551 BHP @ 1500 RPM for continuous duty of suitable for 125 KVA alternator with provision of 10% over load for one hour in every 12 hour running confirming to BS 5514/ ISO 3046 standard totally enclosed as per OEM specification and directed by Engr-in-charge.The engine has the following specification:-a) Mechanical FIPb) Mechanical Governorc) Turbocharger, Exhaust manifold, Stainless steel exhaust flexible connectiond) Radiator cooled, with after coolede) Plate type lube oil coolerf) Filtersg) Lube Oilh) Dry type replaceable paper element air cleanerj) Flywheel housing and flywheel to suit single bearing alternatork) Starting motor-Electric, battery charging alternatorl) First fill lube oil and coolant (ii) Alternator: Brushless alternator, Self -excited, self -regulated, floor mounted with all and / or roller bearings, statically and dynamically balanced screen protected acoustic enclosure confirming to IS 4722 / IS 13364, IP-23 Protection with 'H' class insulation limited temperature rise of class H, Automatic voltage regulator from no load to full load, ammeter capacity of delivery 125 KVA, 415 volts, 3 phase, 50 Hz and lagging for AC supply and will be suitable for tropical conditions all as per OEM and directed by Engr-in-charge.(iii) Instrument Panel : Engine instrument panel consisting of ON/OFF starting switch with key lubricating oil pressure gauge, water temperature gauge, battery charging indicating lamp, hour meter with RPM indicator, safety control against high temperature of water, over speed stop with double driver adopter as per OEM specification and directed by Enge-in-charge. |
| 27 | (iv) Other Fittings:(a) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 88 AH battery at a time(v) DG set shall be supplied along with acoustic original enclosure of the manufacture's suitable for 125 KVA DG Set and all connecting accessories as per Latest CPCB IV+ Norms(vi) The Diesel Oil, Lub Oil etc. for smooth functioning of DG SET during PH-I & PH-Il complete testing and full tank filing of Diesel Oil after PH-I & PH-II testing, topping of Lub Oil etc. required for commissioning and testing of DG set.(vii) AMF Panel: - Supply installing commissioning & testing in microprocessor based AMF panel board factory made, out door type IP-65, cubical type, vermin proof, dust proof, water proof made out of 3.15 mm thick CRCA sheet and angle iron frame of size 50x50x6 mm inside depth not less than 50 cm and size suitable to accommodate the following accessories with insulated TPN Copper busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB suitable for 125KVA DG Set. Hinged door with locking arrangement duly painted with coat of synthetic enamel paint over a coat of red oxide primer both internally and externally and connecting with cable with lugs including internal wiring with copper cable of suitable size using lugs compressing the following accessories all as directed. (Notes : The rate quoted shall include for earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ) and Copper bus bar 240 Amps duly colour sleeved mounted on epoxy insulators-01 set. Note:(i) AMF Panel suitable for 100 KVA DG Set to connect with grid shall be approved by CPRI and certificate to be produced and to be submitted in the office. The AMF Panel has the following specification:-a) 200A, 4 Pole contactor for alternator with thermal over load relayb) 200A, 4 Pole contactor for mainsc) MCB for short circuit protectiond) Indication LED (Dg ON, Load on DG, Main ON, Load on Main, Battery charge on)e) Push Buttons (Engine START/STOP, Generator contactor CLOSE/TRIP, Main Contactor CLOSE/TRIP if provided, Fault ACCEPT/RESET)f) Voltmeter & Ammeter and other connecting accessories and safety features for successful auto operation of 125 KVA DG Set.(viii) Excavation, earthwork and provn of PCC plinth of suitable sizes for installation of DG set & connected accessories complete as per OEM/ site requirements. |
| 28 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and as directed by Engr-in- Charge. Makes :- Automatic electrical (AE)/ Vinitec/APLAB/V Guard |
| 29 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA complete suitable for inverter type AC all as specified and as directed.Makes :- Automatic electrical (AE)/ Vinitec/APLAB/V Guard / Volina |
| 30 | S&F two-way bib taps 15mm dia, with wall flange and aerator screwed down for iron pipe or for brass ferrule complete all as specified and as directed.Make: Cat No. F1015161 of CERA or Techno commercially equivalent model of Appendix \\"C\\" Makes. Please Enable Macros to View BoQ information |