| 1 | Grubbing up brush & plant of any height & girth and debris of any nature, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing unserviceable material to a distance not exceeding 50m and cleaning site complete all as specified and as directed. |
| 2 | Surface excavation not exc 30 cm deep and averaging 15 cm deep & getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. |
| 3 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. |
| 4 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. |
| 5 | Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed. |
| 6 | Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed. |
| 7 | M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified & as directed. |
| 8 | M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets, padding over roof and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 9 | M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete all as specified & as directed. |
| 10 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 11 | M&L for Moorum/ red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. Note : Measurement shall be taken after consolidation. |
| 12 | M&L for anti-termite treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed. |
| 13 | M&L for anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed. |
| 14 | M&L for anti-termite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed. |
| 15 | M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified & as directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 16 | M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in chajjas and the like complete all as specified & as directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 17 | M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & as directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 18 | M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts, struts and the like complete all as specified & as directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 19 | M&L for 40mm thick PCC 1:2:4, type B0 (using 12.5 mm graded crushed stone aggregate) as in damp proof course to horizontal or verticle surfaces including necessary formwork complete all as specified & as directed. |
| 20 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & as directed. |
| 21 | Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified & as directed. |
| 22 | Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed. |
| 23 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed. |
| 24 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 25 | S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Grade E-165 (Fe 290), complete, all as specified & as directed. |
| 26 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed. |
| 27 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed. |
| 28 | All as per serial item No. 27 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders. |
| 29 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410-W (Gde E-250) quality 'A’ complete all as specified and as directed. |
| 30 | S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed. |
| 31 | S&F steel rolling shutters, 1.25mm thickness of laths, push pull or manual type, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete all as specified and as directed. |
| 32 | S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing, powder coated aluminium snap on beading, neoprene gasket etc. complete all as specified and as directed. |
| 33 | S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, glazed and gauze, fixed/ sliding type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws etc. complete all as specified and as directed.Note: Glass shall be measured and paid seperately. Please Enable Macros to View BoQ information |
| 34 | S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, glazed and gauze, fixed/ sliding type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws etc. complete all as specified and as directed.Note: Glass shall be measured and paid seperately. Please Enable Macros to View BoQ information |