Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Note: The Bidder must quote the values inlcuding Taxes. |
| 2 | BUILDING WORKS |
| 3 | EARTH WORK |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.Hard rock (blasting prohibited) |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 7 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.All kinds of soil |
| 8 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.Ordinary or hard rock |
| 9 | CONCRETE WORK |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | REINFORCED CEMENT CONCRETE |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 19 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 20 | MASONRY WORK |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M.S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. |
| 23 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 24 | Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 25 | STONE WORK |
| 26 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 27 | CLADDING WORK |
| 28 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm |
| 29 | Providing edge moulding to 18 mm thick marble stone counters, Vanities, etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 30 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 31 | Providing and fixing cramps of required size & shape in RCC/ CC/ Brick masonry backing with cement mortar 1:2 (1 cement : 2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps |
| 32 | Providing and fixing expansion hold fasteners on C.C. / R.C.C. / Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion typeFastener with threaded dia 6 mm |
| 33 | WOOD AND P.V.C. WORK |
| 34 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood |
| 35 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.Sal Wood |
| 36 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(Note: Butt hinges and necessary screws shall be paid separately)Second class teak wood 35 mm thick shutters |
| 37 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Second class teak wood |
| 38 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 39 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 40 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm, 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 41 | STEEL WORK |
| 42 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 43 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 140 mm |
| 44 | FLOORING |
| 45 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand):25 mm thick |
| 46 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1 :3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 47 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 48 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 49 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x300 mm Anti Skid |
| 50 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x300 mm (Wall Tile) |
| 51 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge:Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 52 | FINISHING |
| 53 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 54 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 55 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 56 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 57 | French spirit polishing :Two or more coats on new works including a coat of wood filler |
| 58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 59 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 60 | NON-SCHEDULE ITEMS |
| 61 | Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Himalayan stone - exposed face fine dressed with rough backing50 mm thick ( 450mm x 200mm) (Wall Cladding Stone) |
| 62 | Providing and fixing bright finished brass handles with screws etc. complete:Pull handleModel no-VISH GSSize 200 mm, (vintage brass) |
| 63 | Providing and fixing bright finished brass handles with screws etc. complete:Pull handleModel no-VISH ABSize 100 mm |
| 64 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. completeModel no- VX Size (200x12) mm, (vintage brass) |
| 65 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. completeModel no. - VX Size (150x12) mm |
| 66 | Providing and fixing bright finished brass 250 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. completeModel No. - Lever Handle Tango CY with Lock body and cylinder 60mm OSK |
| 67 | Providing and fixing bright finished brass mortice latch and a pair of lever handles of approved quality with necessary screws etc. completeModel No. - Lever Handle Tango DY with BL-3 Latch for bathroom |
| 68 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (100x75x3) mm |
| 69 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (125x75x4) mm, (vintage brass) |
| 70 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Brass casement stays (straight peg type) 200 mm weighing not less than 0.24 kgSize 150 mm |
| 71 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Model No- DS 02Size: 140 mm |
| 72 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:Sliding Bolt (300x16) mm, EX-02 |
| 73 | Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc. |
| 74 | Providing, laying and fixing of Second Class Deodar Wood as in built runner having size of 100mmX75 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer / sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification. |
| 75 | 25mm wooden planking, tongued & Grooved in Ceiling, including fixing with iron screws complete with 150 mm wide second Class deodar wood plank. |
| 76 | Providing and fixing Second Class Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank. |
| 77 | Providing and fixing 2nd class deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.25mm thick |
| 78 | Two or more coats on new works including a coat of wood fillerHydro Oil For Exterior Coating |
| 79 | Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles having multilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/ 8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H. The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Equivalent. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc.The design and methodology to be approved by Engineer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a complete job. |
| 80 | Providing and fixing Stainless Steel L Patti for Ceiling work (Fixed in position with Rafter) of size 50x50x25x2 mm, with Holes and Screw. |
| 81 | Civil Works for Electrical |
| 82 | RCC MANHOLE |
| 83 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 84 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge.Ordinary rock |
| 85 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.All kinds of soil |
| 86 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.Ordinary or hard rock |
| 87 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 88 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 89 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 90 | Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 91 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 92 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 93 | GULLY TRAPS |
| 94 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design:With 20x20 mm square bar |
| 95 | NON-SCHEDULE ITEMS |
| 96 | Providing and fixing in position FRP Recessed Cover with frame 600mm x 600mm, Capacity 25 Ton of required Shape & approved quality.Pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 97 | Civil Works for PHE |
| 98 | WATER SUPPLY& SEWAGE WORKS |
| 99 | LAYING OF PIPES |
| 100 | Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 101 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Ordinary rock :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 102 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 103 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9Sand filling |
| 104 | RCC MANHOLE |
| 105 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 106 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge.Ordinary rock |
| 107 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.All kinds of soil |
| 108 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.Ordinary or hard rock |
| 109 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 110 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 111 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 112 | Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 113 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 114 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 115 | GULLY TRAPS |
| 116 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 117 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design:With 20x20 mm square bar |
| 118 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 119 | SEPTIC TANK & SOAK PIT |
| 120 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 121 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge.Ordinary rock |
| 122 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.All kinds of soil |
| 123 | Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials.Ordinary or hard rock |
| 124 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 125 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 126 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 127 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 128 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 129 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 130 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in:Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 131 | 12 mm Cement Plaster of mix:1: 6 (1 cement: 6 fine sand) |
| 132 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 133 | NON-SCHEDULE ITEMS |
| 134 | Providing and fixing in position FRP Recessed Cover with frame 600 mm x 600 mm, Capacity 25 Ton of required Shape & approved quality.Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. |
| 135 | Demolition |
| 136 | Demolition of the existing buildings at the site |
| 137 | PLUMBING |
| 138 | Sanitary Fixutures and Fittings |
| 139 | Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend as per specifications; glazed vitreous / Coloured European Water Closet with metropole flush valve, with grouting the CI chair in side the floor/wall, rubber gaskets, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern on WC.,1 No.CPVC connection with brass union nuts CP coated and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; including painting of fittings and brackets, cutting and making good the walls wherever require: etc. complete. The rates including cost and conveyence of all materials, labour, machinery etc.EWC-P with Soft close Seat cover : Jaquar, Model No: CNS-WHT-959SMetropole flush valve Dual flow : Jaquar, Model No: FLV-1085NG |
| 140 | Providing and fixing White glazed vitreous Wash Basin Oval Under-Counter, size 560 x 430 x 195 mm dia., with supporting M.S. or C.I. Brackets, necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full thread with 80 mm height Chrome plated, Bottle trap Chrome plated Basin Mixer necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. OVAL UNDER COUNTER BASIN: Jaquar , Model No: FLS-WHT-5701WASTE COUPLING : Jaquar , Model No: ALD-CHR-705BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190Basin Mixer: Jaquar , Model No: FLR-5001B |
| 141 | Providing and fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. ANGLE VALVE : Jaquar, Model No. FLR-5053NBRAIDED HOSE Copper Pipe : Jaquar, Model no. ALD-CHR-805B |
| 142 | Providing and fixing in position 15 mm C.P. brass long body bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc.BIB COCK : Jaquar Continental, Model No: CON-107KN |
| 143 | Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1.2 Rmt Long pvc Tube and Wall Hook accessories of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. HAND SHOWER : Jaquar , Model No: ALD-573 |
| 144 | Providing and fixing in position best Indian make toilet recessed type paper holder complete in all respects including cutting and making good the walls etc. TOILET PAPER HOLDER : Jaquar , Model No: AHS-1553 |
| 145 | Providing & fixing C.P. brass towel ring fixed to rawl plug with C.P. brass screws.TOWEL RING : Jaquar Continental, Model No.: ACN-1121BN |
| 146 | Providing and fixing C.P. brass liquid soap container of best quality. LIQUID SOAP CONTAINER: Jaquar , Model No: SDR-WHT-DJ0010F |
| 147 | Providing and fixing in position best Indian make C.P. brass twin way QUOTE and hat hooks fixed into wall with C.P. Brass screws and rawlplugs etc. complete including cutting and making good the walls etc.DOUBLE QUOTE HOOKS: Jaquar, Model No: -ACN-1161N |
| 148 | Providing and fixing of electrical Instant type water Geyser inclusing all required accessories cutting, chassing and good the same.6 Litre Insta, Make: Jaquar Elena Insta |
| 149 | Electrical hand dryer, fully automatic type , cover shall be fabricated in extra heavy duty18 gauge type 304 SS with exposed surfaces satin finished, the unit shall deliver not less than 71 l/sec of hot air and electrical rating shall be 240 V / 1 phase / 50 cycles HAND DRYER : Jaquar , Model No: HDR-SSF-AK2803D |
| 150 | Providing and fixing C.P. brass air purifier fixed to wooden cleats with C.P. brass screws complete. Air Purifier: Euronics , Model No: EA-33 |
| 151 | Providing and fixing white vitreous china flat back urinal of size 385x325x635mm as per IS-2556 (Part-2) with C.I. hangers and 15mm dia. C.P. spreader,Waste coupling, 32mm dia CP bottle trap and pipe to wall with C.P. flange with Pressmatic Urinal Flush valve with wall Flange etc. complete including cutting and making good the walls wherever required.FLAT BACK LARGE URINAL : Jaquar , Model No: URS-WHT-13253NWASTE COUPLING : Jaquar ,Model No: ALD-705L130BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190Pressmatic Urinal Flush : Jaquar, Model No: PRS-073 |
| 152 | Providing and fixing in position 15 mm C.P. brass bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc.BIB COCK : Jaquar Fusion , Model No. FUS-29037 |
| 153 | Internal Drainage Work |
| 154 | Providing, installation, testing and commissioning of 50 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1.The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs, fixing waste pipes to the floor with concrete bedding for full length etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge.(Soil, Waste & Vent Pipe) |
| 155 | Providing, installation, testing and commissioning of 75 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1.The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs, fixing waste pipes to the floor with concrete bedding for full length etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge.(Soil, Waste & Vent Pipe) |
| 156 | Providing, installation, testing and commissioning of 110 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1.The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/ plugs etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge.The scope shall be also include Providing and laying 100mm thickness cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) around the pipe etc. complete the job as directed by Engineer in charge.(Soil, Waste & Vent Pipe) |
| 157 | Supply, installation, testing and commissioning of Polypropylene (PP) 110mm x 110mm size P trap with necessary of self cleaning design with water seal with and without vent arm jointing with push fit rubber ring socket fittings complete, as required height riser for basin/ sink/ Urinal drain connection with necessary distance piece of pipe, inlet hopper with two or three inlets fittings to receive waste pipes from fixtures waste and hopper shall be Manufactured from 110 mm dia. up to 600 mm long, etc., cutting chases/ hole in floors/ slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended/ open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing, etc. complete the job as directed by Engineer-in-charge. |
| 158 | Providing and fixing PTMT grating of Rectangular type with openable circular lid of 150mm nominal size square 100 mm diameter of the inner hinged round grating of approved quality and colour. |
| 159 | Providing and fixing of 125 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge. |
| 160 | Providing and fixing of 180 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge. |
| 161 | Providing and fixing of 225 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge. |
| 162 | Internal Water Supply Work |
| 163 | Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.PN - 16 Pipe, 20 mm OD (SDR-7.4) |
| 164 | Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.PN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 165 | Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.PN - 16 Pipe, 32 mm OD (SDR-7.4) |
| 166 | Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. |
| 167 | Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. |
| 168 | Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge. Internal Exposed on wallsPN - 16 Pipe, 20 mm OD (SDR-7.4) |
| 169 | Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge. Internal Exposed on wallsPN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 170 | Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge. Internal Exposed on wallsPN - 16 Pipe, 32 mm OD (SDR-7.4) |
| 171 | Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge. Internal Exposed on wallsPN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 172 | Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge. Internal Exposed on wallsPN - 10 Pipe, 50 mm OD (SDR-11) |
| 173 | Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge. Internal Exposed on walls |
| 174 | Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.PN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 175 | Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.PN - 16 Pipe, 32 mm OD (SDR-7.4) |
| 176 | Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 177 | Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.PN - 10 Pipe, 50 mm OD (SDR-11) |
| 178 | Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.PN - 10 Pipe, 63 mm OD (SDR-11) |
| 179 | Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support, etc. (Inside Toilet) for 20 dia pipe |
| 180 | Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support, etc. (Inside Toilet) for 25 dia pipe |
| 181 | Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support, etc. (Inside Toilet) for 32 dia pipe |
| 182 | Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support, etc. (Inside Toilet) for 40 dia pipe |
| 183 | Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support, etc. (Inside Toilet) for 50 dia pipe |
| 184 | Supplying, laying/ fixing, testing and commissioning of following 50mm thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on pipe and finally applying 0.63mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required. |
| 185 | Providing and fixing of 25 mm diameter gun metal gate valve with C.I. wheel of approved quality |
| 186 | Providing and fixing of 32 mm diameter gun metal gate valve with C.I. wheel of approved quality |
| 187 | Providing and fixing of 40 mm diameter gun metal gate valve with C.I. wheel of approved quality |
| 188 | Providing and fixing of 50 mm diameter gun metal gate valve with C.I. wheel of approved quality |
| 189 | Providing and fixing of 65 mm diameter gun metal gate valve with C.I. wheel of approved quality |
| 190 | Supplying, fixing, testing and commissioning of 50 mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified. |
| 191 | Providing and fixing of 65 mm diameter gun metal non- return valve (vertical) of approved quality |
| 192 | Supply, Installation, Testing and Commissioning of 25 mm dia. air release valve.) Make: Audco/ R.B./ Spirex) |
| 193 | Providing and fixing 25mm dia float valve with pressure type PTMT float valve.(Make: Prayag) |
| 194 | Providing and fixing mosquito proof stainless steel overflow grating for tanks.( Zoloto/ Audco/ R.B./ Spirex) |
| 195 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. |
| 196 | Supplying and fixing 50 mm thick aluminium foil faced resin bonded fibre glass insulation (for polyethylene water storage tank) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cum after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63 mmx19 mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications) |
| 197 | Supply, intallation, Testing and Commisioning of 20mm diameter Garden Hydrant with gun metal Ball Valve, Flexinble hose Connection Provision and all required accessories etc. |
| 198 | Supplying, fitting & fixing of 65mm dia Pressure Reducing Valve set of approved make & best quality having by-pass valve arrangement including of 3 nos isolation valve. |
| 199 | Making connection to Water Supply line / existing tank including breaking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing water line in the existing structure either through masonry or CC and providing suitable \\"Y\\" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions tasting etc complete. |
| 200 | Fire Fighting System |
| 201 | 6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. |
| 202 | ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. |
| 203 | PLAZA |
| 204 | EARTHWORK |
| 205 | Excavation in foundation for retaining, breast walls etc., in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technicalspecifications Clause 305.1 of MORD Specification |
| 206 | MASONRY WORK |
| 207 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 208 | Providing and fixing cramps of required size & shape in RCC/ CC/ Brick masonry backing with cement mortar 1:2 (1 cement : 2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps |
| 209 | Providing and fixing expansion hold fasteners on C.C. / R.C.C. / Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.Wedge expansion typeFastener with threaded dia 6 mm |
| 210 | BASES AND SURFACE COURSES |
| 211 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge) |
| 212 | Granular Sub-base with Well Graded Material (Table 400.1)By Mix in Place MethodConstruction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For Grading I Material |
| 213 | Wet Mix Macadam laying Using Mechanical Paver (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in subbase / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.) |
| 214 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) |
| 215 | NON-SCHEDULE ITEMS |
| 216 | Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately):Himalayan stone - exposed face fine dressed with rough backing50 mm thick (450 mm x 200 mm) (Wall Cladding Stone) |
| 217 | Providing & Laying 80 mm thick Cement Concrete cobble stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), side buttered with cement mortar 1:2 (1 cement: 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Jet Black with minimum average 300 kg/cm2 (100x100x80) mm (+-5% of size) |
| 218 | HORTICULTURE |
| 219 | Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for |
| 220 | Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed)In rows 7.5 cm apart in either direction |
| 221 | Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm) |
| 222 | ELECTRICAL PART |
| 223 | MV PANEL |
| 224 | Supply, Installation testing & commissioning of medium Voltage sheet steel metal clad, compartmented cubicle Panel board. Detail specification shall be followed.Shifting of panels from site store to the suitable location. Assembling and wiring of component supplied separately.Earthing all components, frame etc. to a common internal earth bar.Connection, testing & commissioning. Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge.Supply, installation, testing and commissioning all accessories, supporting structure, hardware etc. to complete the job.Supply, installation, testing and commissioning of necessary tools, hardware, testing hardware, testing equipment etc.The rates for the distribution boards apart from the Breakers and instruments shall also include the following :This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings.Supporting rigid steel framework. Cubicle type, 14 gauge CRCA sheet steel enclosed. Proper bonding to earth.Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram.Providing cable clamps / supports within distribution boards cable alley. If any TPN ACB’s / MCCB, it shall be with adequate size of neutral link.All MCB’s shall be of minimum 10 KA breaking capacity.The breaking capacity of MCCB’s are mentioned panel wise. |
| 225 | All MCCB’s shall be with thermal magnetic releases upto 250 amps and microprocessor based above 250 amps capacity, unless specified otherwise.All motor feeders MCCBs shall be of motor duty.Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.IP 41 for all Indoor panel.IP 65 and double door for all outdoor panel.All MCCB’s shall be provided with operating mechanism for door interlock.All measuring instruments (Meters) shall be of digital electronic with LED of approved make.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.All panels shall have provision of the following:Pad locking of Switch board doors.Pad locking of MCCB’s handles in “OFF” Position.All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.SPD as shown in SLDApproved Makes-L&T/ABB/schnider/Legrand/SIEMENS |
| 226 | Supply, Installation, testing and commissioning of IP 54 (Indoor type-Double Door) rated ELE. PANEL of Institutional Building Having Incomer: 100A FP MCCB ADJUST. TM BASED RELEASE O/L, S/C, E/F, PROTECTION WITH UV, SHUNT RELEASE) (WITH RS-485 PORT) (01 No).1 NO SPD1 NO MFM WITH RS485 PORT1 NO. DIGITAL VOLTMETER WITH VOLTAGE SELECTOR SWITCH1 NO. DIGITAL AMP METER WITH AMETER SELECTOR SWITCHINDICATION LAMP- 6 NOS (R,Y,B,ON,OFF,TRIP)CT, 100/5A, CL-1,10VA Out Going: 63 Amp FP 10KA MCB (01 NOS.)40 Amp FP 10KA MCB (04 NOS.)25 Amp FP 10KA MCB (01 NOS.)40 Amp DP 10KA MCB (01 NOS.)25 Amp DP 10KA MCB (02 NOS.)CONTRACTOR TO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 227 | Supply, Installation, testing and commissioning of IP 54 (Indoor type - Double Door) rated FACADE/ EXTERNAL LIGHTING DB Having,Incomer: 25A, DP RCBO (30mA-10KA) (01 No).AUTO MANUAL SWITCH WITH SINGLE CHANNEL DIGITAL TIMER WITH 48HR BATTERY BACK-UP AUTO-MANUAL BY-PASS SWITCH25A, DP CONTACTOROut Going: 10 Amp SP 10KA MCB (08 NOS.)CONTRACTOR TO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 228 | MV CABLES |
| 229 | Laying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/DWC pipe as required. |
| 230 | Upto 35 sq.mm |
| 231 | Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor, Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified.The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include:1) Supply of Cables.(With Non Returnable Drums)2) Delivery of the cables at site.3) Unloading at site store.4) Shifting of cable from site store to place of installation.5) Connection of cable with proper tagging as specified ni specifications.6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely.7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.8) Testing of insulation and continuity of cable and submission of reports to the client's representative.9) To prepare submission drawing and to take approval of consultant at each stage.10) To prepare & submit as-built drawing and handing over document to end user.11) Rate shall be inclusive of route markers at 15mtr intervals12) Each run of cable to be tested with 1KV meggar13) Proper cables tags of Aluminium shall be made and feeder shall be written.Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS |
| 232 | 3.5C x 70 Sq.mm. Aluminum XLPE armored cable |
| 233 | 4C x 10 Sq.mm. CU XLPE armored cable |
| 234 | 4C x 6 Sq.mm. CU XLPE armored cable |
| 235 | 4C x 4 Sq.mm. CU XLPE armored cable |
| 236 | 3C x 4 Sq.mm. CU XLPE armored cable |
| 237 | 3C x 6 Sq.mm. CU XLPE armored cable |
| 238 | 3C x 10 Sq.mm. CU XLPE armored cable |
| 239 | 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 240 | CABLE TERMINATION |
| 241 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed/ XLPE copper conductor cable of 1.1 KV grade as requiredApproved Makes: DOWELL'S/ 3D/ HEX JAINSON/ COMET/ HMI/ CCI |
| 242 | 3.5C x 70 Sq.mm. Aluminum XLPE armored cable |
| 243 | 4C x 10 Sq.mm. CU XLPE armored cable |
| 244 | 4C x 6 Sq.mm. CU XLPE armored cable |
| 245 | 4C x 4 Sq.mm. CU XLPE armored cable |
| 246 | 3C x 4 Sq.mm. CU XLPE armored cable |
| 247 | 3C x 6 Sq.mm. CU XLPE armored cable |
| 248 | 3C x 10 Sq.mm. CU XLPE armored cable |
| 249 | 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 250 | DISTRIBUTION BOARD |
| 251 | Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-12way, Double door (IP43, IK09) |
| 252 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4+24), Double door (IP43, IK09) |
| 253 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240V \\"B\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 254 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal encloused plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 255 | Supplying and fixing 40 amps rating, 240 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A Double pole |
| 256 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 257 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 40A |
| 258 | Supply, installation, testing and commissioning 'C' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 259 | INTERNAL WORK |
| 260 | POINT WIRING |
| 261 | Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points.Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. |
| 262 | Wire Size for Lighting circuitLighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board)From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E)Power circuit (for heater and geyser) = 2x4.0 sqmm (P+N) ,1x4 sqmm(E)Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly.Making of zari in wall using only electric cutter and finishing the surface as it was earthing of fitting electrical connection to the fixture from the out let point/ceiling rose.Wire breaded PVC flexible conduit from ceiling point to light fixture.Supply and fixing of supporting frame, hardware and n/c tools and tackles, etc.For Exhaust fan |
| 263 | Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. Group C |
| 264 | Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 265 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 266 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 267 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A & 15/16 A amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 268 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 269 | 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 270 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 271 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 272 | 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 273 | CONDUIT & OTHER |
| 274 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 275 | 25 mm |
| 276 | Supply, installation, testing and commissioning of following sizes of heavy class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm |
| 277 | Earthing |
| 278 | S/L SWG GI wire in ground:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required |
| 279 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 280 | Supply, Installation, Testing and Commissioning of UL Listed maintenance free, Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250 micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000 kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner.Approved Makes - OBO/ JEFF/ JMV |
| 281 | LIGHT FIXTURE |
| 282 | 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 20W, 2000 Lumen, IP20 4FT Wall/ Ceiling mounted LED light fixtures equivalent to Philips make Philips/BN021C LED22S PSU CW GR S2/01 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI, LED Make CREE/ Osram/ Samsung with LM80 report to be submitted at the time of Supply, life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be WHITE as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes - Philips/ Wipro/ K-Lite/ Lighting Technologies |
| 283 | 18W, 2000 Lumen Surface mounted LED Down light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen, IP20 Surface mounted LED Down light fixtures equivalent to Philips make SMSM296C LED20S- 6500 PSU WH/0 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.* Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI, LED Make CREE/ Osram/ Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be BLACK as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes - Philips/ Wipro/ K-Lite/ Lighting Technologies |
| 284 | 18W, 2000 Lumen Recess mounted LED Down light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen, IP20 Recess mounted LED Down light fixtures equivalent to Philips make DN296B LED20S- 6500 PSE WH S1 /04 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.* Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI, LED Make CREE/ Osram/ Samsung with LM80 report to be submitted at the time of Supply, life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be BLACK as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes - Philips/ Wipro/ K-Lite/ Lighting Technologies |
| 285 | WALL MOUNTED LED LIGHT : (MIRROR LIGHT)Supply, Installation, assembling, connection, testing & commissioning of Mirror LED Light suitable for 12W luminaire along with all other necessary accessories. Equivalent to Philips/BN021CLED12S PSU CW GR/02. IP20. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI, LED Make CREE/ Osram/ Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be WHITE as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes - Philips/ Wipro/ K-Lite/ Lighting Technologies |
| 286 | LED BULK HEAD LIGHT FIXTURE:Supply, laying, connection and testing of LED bulk head suitable for 12W, IP65 luminaire along with all other necessary accessories.. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI, LED Make CREE/ Osram/ Samsung with LM80 report to be submitted at the time of Supply, life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes - Philips/ Wipro/ K-Lite/ Neri |
| 287 | Weather Proof Downlighter : SITC of CEILING LED Fixture-LED 12W, LED Electronic Driver which offers Protection against Short Circuit, Over-Voltage & Over-Current, IP65/ IP 66 protection, CRI > 70, voltage input AC100-240V. Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt, Dimension-126mm(Dia.)x138mm(H), Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000 hours minimum.* Colour of light fixture shall be BLACK as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Bega/DW Windsor |
| 288 | Up & Down LightSITC of 2X10 W LED Up down light suitable for wall mounting, BIS approved, Body made of pressure Die cast aluminium, proper heat sink should be designed for better heat dessipation, The diffuser should be clear toughned glass with IK08 protection. The luminaire is provided with surge protection of 4 KV. Electronic driver having power factor>0.95, THD <15 % and input voltage range from 150-270V AC at 50Hz. Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 as per ANSI, LED Make CREE/ Osram/ Samsung with LM80 report to be submitted at the time of Supply, life of 50000 burning hours with 70% of initial lumens maintained. Ambient Operating Temperature is -10 Deg. to 50 Deg. Luminaire should Maintain Ingress Protection of IP65/ IP66 for better weather proofing.* Colour of light fixture shall be Matt Black as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Bega/DW Windsor along with all other necessary accessories. |
| 289 | FIXTURE 40-45W Power Module LED:Supply, Installation, assembling, connection, testing & commissioning of post top light fixture equivalent to LED FIXTURE - 40-45W Power Module LED, MOUNTED AT 4 METER HEIGHT POST TOP POLE, CCT: 2700/3000 K THD <10% Upper frame made in die-cast and sheet aluminium (thickness: 2.5 mm), with threaded coupling G3/4\\" for fixing Bottom frame with ring made in die cast aluminium and two arms made in hot galvanized steel, with flange for fixing equipped of a hole (dia. 28 mm Gasket between the upper and bottom frames. Painted with polyester powder coating in BLACK (As per Architectural requirement). Rating - IP 66 Height-690 mm, Dia-550 mm, Weight-11.5 Kg, Area Exposed to Wind (1) - 0.105 m2. Power LED's Module (with CREE/ NICHIA/ OSRAM/ SEOUL SMD type LED's with ESD>BKV & Ceramic package are accepted. LED manufacturers tech sheet with buying documents should be submitted for verification. Individual LED's Minimum Luminous Rux (m) & 139m @ 350 mA 85 °C same should be supported by LED manufacturer's tech sheet) in compliance with with IEC 62031 (supporting type test report should be submitted), on Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over Voltage & Over-Current, with in-built surge protection upto 1.5 kV (an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens (Polycarbonate), UV Resistant & Shock Resistance IK10. LM80 Reported LED Lifetime is L90@ 50,000 hours minimum. (same should be supported by LM 80 report from NVLAP accredited lab) & Estimated LED Lifetime is L80 @ 100,000 hours(Ta-25°C) minimum. LM 80 report & TM 21 calculation should be submitted to support the same.The Light fixture shall be in compliance with IEC 60598-2-3; IEC 60598-1. (Supporting Test Report from NABL accredited Laboratory should be submitted). LM79 report should be submitted from NABL accredited Laboratory. *Colour of light fixture shall be BLACK as per Architectural requirements. *Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/ Bega/ DW Windsor along with all other necessary accessories. |
| 290 | Supply, Installation, assembling, connection, testing & commissioning of ARCHITECTURAL POLE (FOR POST TOP LIGHTING] 3.3 m height Pole (Total height of the pole is 4m including post top) Made in combination of hot dip galvanised mid steel pipe sections 114mm dia. & 140mm dia. Arch. cast iron Base design starts with min 322mm Dia, ring, radially tapers to 140 mm for a height of min 235 mm matching to the drawing, Total weight of the base is min 15 Kgs. Decorative King- (140/ 114mm dia., min 3kgs & Top Ring (weight 3kgs.) are made of cast iron. Entire pole shall be made to provide pleasing aesthetics as approved by Concerned Engineerin-charge. After Fabrication, Entire Pole is hot dip galvanized (60 microns Minimum) for the effective corrosion resistance. The hot dip Galvanised pole should be provided with an inbuilt junction box (Concealed to fix 324 connectors and 6A MCB (to terminate incoming and outgoing armoured cables with glands and lulgs, at the bottom-the inbuilt box should have a flush door of suitable size. The decorative pedestal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for erisuring firm grouting into the specially designed RCC foundation, wind pressure calculation as per IS 875(part 3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & it's parts are painted in 3 layer coating (coating thickness-100 microns minimum in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU point-customised colour Metallic Grey As per Architectural requirement). Adequate size cutout with openable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for puling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer-in-charge. Scope also includes necessary foundation, cable termination, earthing as per requirement, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc. all require to complete job. Colour of Pole shall be Matt Black as per Architectural requirements. Contractor to submit samples for Approval before ordering the fixture. Approved Make: NERI/Bega/DW Windsor along with all other necessary accessories. |
| 291 | Landscape BollardSupply, laying, connection and testing of Landscape Bollards 15Watts Bollard LED, IP66, 800/100mm. THD<10% * Colour of light fixture shall be Matt Black as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/Bega/DW Windsor |
| 292 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 293 | Supply of exhuast fan (250 mm)Approved Makes-Havells/ Usha/ Almonard |
| 294 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep. |
| 295 | JUNCTION BOX |
| 296 | Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes with terminal block/ connector. Equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE |
| 297 | Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes with terminal block/ connector. Equivalent to Hensel catalogue no KF 1610 G/OBO/CAPE |
| 298 | Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes (225mm (L) X 295 mm (B) X 122 mm (H)) with connector & including GEL.Equivalent to Hensel catalogue no KF 3500 C/OBO/CAPE |
| 299 | CABLE TRAYS |
| 300 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required |
| 301 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 302 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 303 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 304 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 305 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 306 | DWC PIPE |
| 307 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 308 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 309 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 310 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 311 | HDPE Pipe 32mm PE-80, PN6 direct in ground; to be laid 75-100 cm below the ground level for drawing of cables including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering, or G.I. conduit 32 mm dia (Heavy Duty) with concrete block 15 cm X 15 cm 1:2:4 with complete curing with splicing complete in all respect.Make: Jain/ Dutron/ Supreme/ reliance |
| 312 | Supply installation Testing and commissioning of 6 KVA (SINGLE PHASE) on line UPS system confirms to IS 16242 (Part-1):2014 and IEC 60240-1: 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input/ Single phase output with minimum 15 minutes battery back up of each UPS.Approved Makes: Eaton/ Neumeric/ APC |
| 313 | LIGHTING PROTECTION SYSTEM |
| 314 | Contractor to design lightening protection system along with SITC work. Contractor also need to submit Risk Analysis report based on site condition and location. Contractor to take soil resistivity report and necessary consideration to be taken along with below items. In general, the complete system design and installations shall confirm to latest IEC/IS Standards and the specifications, drawings submitted here with. Quantity and items mentioned here under is just for reference; Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall include all necessary accessories to comply the installation and design to IS/IEC 62305 requirements, which broadly includes all system requirement. |
| 315 | AIR TERMINAL |
| 316 | Supply, Installation, Testing and Commissioning of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305), OBO Type No. RD 8/ALU (5450 08 6) or equivalent as per make. |
| 317 | Supply, Installation, Testing and Commissioning of Roof conductor holder for sheet as specified in drawing, Bottom section made of stainless steel (V2A) & conductor holder made up of polyamide with Ø 8.5 mm slot at bottom. OBO Type No. 159 K-VA (5216-81 8) or equivalent as per make. |
| 318 | Supply, Installation, Testing and Commissioning of cross universal connector: For T and cross connection, to route vertical down conductor/ mesh formation made of hot dipped galvanised iron with necessary screws etc. as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts. OBO Type No. 251 8-10 (5312 03 5) or equivalent as per make. |
| 319 | Supply, Installation, Testing and Commissioning of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561 or equivalent as per make. |
| 320 | Supply, Installation, Testing and Commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 ) or equivalent as per make. |
| 321 | Supply, Installation, Testing and Commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305) (2nos. / expansion piece). OBO Type No. 249 8-10 ST (5311 50 0) or equivalent as per make. |
| 322 | Supply. Installation, Testing and Commissioning of Bridging cable: From flexible CU cable of 16mm2 with black colur coating chlorinated India rubber mixture. Exclusively used for indoor & outdoor application to make continuity at terminals. OBO Type No. 853 300 (5331 01 3) or equivalent as per make |
| 323 | Supply, Installation, Testing and Commissioning of Bridging cable with 319 8 Clamping Shoe, 8 mm (5325 307) or equivalent as per make. |
| 324 | DOWN CONDUCTOR |
| 325 | Supply, Installation, Testing and Commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90 mm square. According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. OBO Type No. 5052 DIN 30X3 ( 5450 43 6) or equivalent as per make. |
| 326 | Supply, Installation, Testing and Commissioning of diagonal clamp suitable for FL 30. Installed with 2 hexagonal bolts. OBO Type No. 250 A FT (5313 01 5) @every 2mts or equivalent as per make. |
| 327 | Supply, Installation, Testing and Commissioning of Cross connector for earth fixing point suitable for FL 30. Installed with 2 hexagonal bolts. OBO Type No. 250 (5312 90 6) or equivalent as per make. |
| 328 | Supply, Installation, Testing and Commissioning of Earth fixing point of OBO type No: 250 DG-L180 (5420 02 2) or equivalent as per make. |
| 329 | Supply, Iristallation, Testing and Commissioning of Cross connector for Flat: Suitable for 30 mm Galvanised steel strip, Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4) or equivalent as per make. |
| 330 | Supply, Installation, Testing and Commissioning of Connector, Rd 8-10 mm with pressure trough with fix contact clamping screw, nut and serrated washer Including pre-mounted pressure sump, steel Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305). Used to connect the aluminium conductor with the earth fixing point OBO type no: 249 8-10 ST-OT (531150 3) or equivalent as per make. |
| 331 | RING & VERTICAL EARTHING SYSTEM |
| 332 | Supply, installation, Testing and Commissioning of Galvanised Steel Flat 30x3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164 2 (VDE 0185 part 202) Meets the requirement of VDE 0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. OBO Type No. 5052 DIN 30X3 (5450 43 6) or equivalent as per make. |
| 333 | Supply, Installation, Testing and Commissioning of diagonal clamp suitable for FL 30. Installed with 2 hexagonal bolts: OBO Type No. 250A FT (5313 01 5) @every 2mts or equivalent as per make. |
| 334 | Supply, Installation, Testing and Commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4) or equivalent as per make. |
| 335 | EARTH KIT |
| 336 | Supply, Installation, Testing and Commissioning of UL Listed maintenance free, Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250 micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000 kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. |
| 337 | SURGE PROTECTION DEVICE |
| 338 | Supply, Installation, Testing and Commissioning of combination surge arresters Class B+C according to IEC 61643-1 for the lightning protection zone 0-2 consisting of din mountable-one common base consisting of 1 numbers of modular pluggable units of high energy varistor based technology to be connected between line to neutral and 1 number of GDT to be connected between neutral to earth complying the below technical parameters:a) Nominal voltage between L-N, Un = 230 voltsb) Maximum continuous operating voltage between L-N, Uc = 320 voltsc) Maximum continuous operating voltage between N-PE. Uc = 255 voltsd) Lightning Impulse Current (L-N), limp (10/350 micro sec) = 7 KAe) Lightning Impulse Current (N-PE), limp (10/350 micro sec) = 25 KAf) Nominal discharge current in (8/20 micro sec), (N-PE) = 30 KAg) Max discharge current Imax (8/20 micro sec), (L-N) = 50 KA & (N-PE) = 50 ΚΑh) Voltage Protection Level, Up = <1.3 KV (L-N), <1.2 KV (N-PE)i) Response time, tA= <25 (L-N) & < 100 (N-PE) nano secondsj) Working condition of the SPD-Visual indication Green \\"OK\\" & Red \\"Failure\\"k) Temp Range, - 40°C to +80° Cl) Degree of Protection IP: 20 or equivalent as per make. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail