| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE WELLINGTON NAME OF WORK: SPECIAL REPAIRS TO SEATING AND FLOORING OF MULLA AUDITORIUM AT DSSC UNDER GE DSSC WELINGTON Contract No: CWE/ WEL/ OF 2025-26 Bidder Name : PRICE SCHEDULE (BOQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item of Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder including all Taxes etc.Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category Total amount TOTAL AMOUNT With Taxes Total amount in words |
| 2 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as directed by the Engr-in-Charge. |
| 3 | Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 5 | M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc finished even and rough to receive top layer of floor complete all as specified and directed. |
| 6 | M & L for 40 mm thick, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in sub base of flooring, etc finished even and rough to received floor finishes complete all as specified and directed. |
| 7 | M & L for granite stone slab flooring, 18 to 20 mm thick of approved colour/pattern/size (polished/leathered finish) machine cut, rounded edges, bedded, grooved in and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone with grinding and polishing including 20 mm thick screed bed in cement mortor 1:4 complete all as specified and directed. |
| 8 | M & L for granite stone slab, 18 to 20 mm thick as in vertical surfaces such as skirting/dado etc of approved colour/pattern/size (polished/leathered finish) machine cut, rounded edges, bedded, grooved in and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone with grinding and polishing including 15 mm thick screed bed in cement mortor 1:3 & cutting, polishing complete all as specified and directed. |
| 9 | M & L for Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed. |
| 10 | M & L for Vitrified, designed, light shade coloured (light shade), tiles, 8 to 10 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc and set & jointed in neat cement slurry including 20 mm thick screed bed in cement mortor 1:4 complete all as specified and directed. |
| 11 | S & F 2nd class hard wood, Plain fillets. square, rectangular or triangular in section, clean sawn, secured with screws, cross sectional area exc 6 Sqcm and n.exc 13 Sqcm complete all as specified and directed. |
| 12 | S & F Blackout Vertical Blind (Opaque Range) with the following fittings/hardware, accessories and specifications: (i) Head Rail: Head rail shall be of 25mm high and 47mm wide extruded high strength aluminium alloy section with average wall thickness of minimum 0.9mm. The section shall be anodized for smooth operation and should have the provision of shades valance matching with louvers.(ii) End Control Unit (Reduction Gear Box): The end control unit having reduction gear box with reduction ratio of 3.5:1 for smooth operation of the blind. This unit should consist of a planetary gear in the outer housing, four small tansmission gears fitted in the middle assembly and an end receiving gear attached to central sprocket unit.(ii) Tilt Rod: Tilt rod shall be made of extruded aluminium having three keyways. The tilt rod should be fixed in the end control unit and drives the carrier gear mechanism to rotate the louvers. Average diameter 5.8mm to acheive minimum torsion deflection(iv) Tilter Chain: The tilter chain shall be made of 4.5mm plastic beads molded on 1.5mm thick polyester cord. Pitch of the beads shall be 6m. The chain should be drive the sprockets fixed in the end control unit to rotate the louvers by 180 degrees. The pitch of the chain corresponds to the sprockets in perfect ,match for trouble free operation.(v) Carrier (Runner): Component having anti friction additive consisting of polymer housing with wheels mounted on sides and a gear and worm mechanism with vertical worm fixed with a tongued poly carbonate stem to hold the louvers. The worm and gear mechanism should be driven by tilt rod fixed to end control unit to rotate louvers by 180 degrees. The mounted wheels on sides of casing should be 1 move on rail of head rail secgtion for resistance free stacking of louvers.(vI) Fabric: Fabric shall be of 100% polyester fabric, 3 pas foam coating fabrick of thickness 0.6mm and weight of fabric shall be 390 GSM, EPI/PPI 176/164, Wrap: 80 Den Twisted SD, Weft: 300 Den Roto. The unit quoted rate shall include taking down of existing unserviceable curtain rod etc complete all as specified and directed. |
| 13 | S & F Mineral Fibre suspended ceiling system with optima concealed fine texture ceiling panel of 12mm thick with concealed grid as per the manufacturer's instructions. The tiles shall have fine texture fibreglas composition with bevealed concealed edge profile, Noise Reduction Coefficient (NRC) ASTM C 423 0.80-0.90, Articulation Class (AC): ASTM E 1111, Flame Spread: ASTM E 1264; Class A, Light Reflectance (LR) White Panel: ASTM E 1477 with metal suspension components: Main beams and cross tees, base metal and end details, fabricated from commercial quality hot dipped galvanised steel complying with ASTM A 653. Main beams and cross tees are double webs steel construction exposed flange design. Exposed surfaces chemically cleansed, capping pre-finished galvanised steel in baked polyester paint. Main beams and cross tees shall have rotary stitching, 441 - border clip for VECTOR panels as per manufacturer's; 442A - Hold down Clip for VECTOR panels (for all installation), 7425 (24\\"), 7431 (30\\"), 7445 (48\\") 7461 (60\\"0, stabilizer bar, 522 - Midpoint Clip (for panel over 30\\" wide), 5.7870 - Spring Border clip and concealed fixture kit include 24 straight trim pieces and required speed clips and necessary fittings complete all as specified and directed.(Make: Armstrong World Industries or equivelant of make as per list of manufacturer's) |
| 14 | M & L for preparation & cleaning of old wooden surfaces of any description, not otherwise described, over 10 cm width or girth including filling of holes/dents with filler materials and applying one coat of touch wood polish including necessary scaffolding upto a height of 15m complete all as specified and directed. |
| 15 | M & L for Preparation old plastered surfaces of walls of any description over 10 cm width or girth not otherwise described after complete removal of existing treatment and applying two coats of Royale Shyne Paint (of Asian Paints) or Royale Luxury emulsion (of Burger) or Dulux Gaurdian or equivelant of approved colour over a coat of deco prime primer over 1m thick of wall care putty to a smooth surface including necessary scaffolding upto a height of 15m complete all as specified and directed. |
| 16 | Taking out/removing existing detoriated water proofing treatment of any type including cement screed and removing debris off the premises and cleaning the roof surfaces complete all as specified and directed. |
| 17 | M & L for 20mm thick cement screed in cement mortar 1:3 admixed with liquid water proofing compound (FOSROC Nitobond SBR) at 2% by weight of cement as per manufactuer's instructions complete all as specified and as directed. (Make: M/S FOSROC or equivelant make as per List of manufacturer's)(Note: Liquid water proofing compound shall be measured and paid seperately as supply) |
| 18 | Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 19 | M & L for providing APP based polymeric membrane as in roof treatment, m,inimum weight 4.5 Kg/Sqm and miniumk 4mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/Sqm) land on bitumenous primed surface by forced application including necessary required overlapped and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning the surfaces and finsihed the surfaces with two coats of aluminium paint complete all as per manufacturer's instruction and as specified and directed. |
| 20 | M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as in roof kerb or mud stop, benching etc rounded or chamfered on edges incuding necessary form works etc complete all as specified and directed. |
| 21 | Disconnecting existing tanks, exc 250 and n.exc 500 Litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 22 | Demoltion of Brickwork or stone/boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles as directed by the Engr-in-Charge. |
| 23 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 24 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 25 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 26 | Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall and preparation of new surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant primer over 1mm thick wall care putty to a smooth surface complete all as specified and directed. |
| 27 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over 1mm thick of wall care putty to a smooth surface complete all as specified and directed. |
| 28 | Taking out/removing existing unserviceable tip up Chairs and removing from site of work complete all as directed by the Engr-in-Charge. |
| 29 | S & F Tip up back push (21 inch) chair of size 990mm height, 580mm Centre to Centre width and 780mm depth fixed to floor with suitable adhesive and expansion bolts etc (anchor fasteners shall not be less than 10mm dia and length 120mm) all as per manufacturer's instruction's complete all as specified and directed. (Make: S R Seating Private Limited, Model No. SR 02 or equievalent of make as per list of manufacturer's) |
| 30 | S & F Slider Push Back (22 inch) chair of size 1140mm height, 559mm Centre to Centre width and 660mm depth fixed to floor with suitable adhesive and expansion bolts etc (anchor fasteners shall not be less than 10mm dia and length 120mm) all as per manufacturer's instruction's complete all as specified and directed. (Make: S R Seating Private Limited, Model No. SR 07 or equievalent of make as per list of manufacturer's) |
| 31 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed. |
| 32 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. |
| 33 | Disconnecting/dismantling old existing unserviceable DBs/VTPN etc any type/ways including all fittings and fixtures such as MCBs, isolator, RCCB, MCCB etc and removing from site complete all as specified and directed. |
| 34 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module flush to wall including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and directed..(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) Unit quoted rate is deemed to include modular metal flush boxes with modular cover plate of suitable module with frame(iii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 35 | All as per item No. 33 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 36 | M & L for Point wiring with 2.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core, unsheathed, copper conductor cables conforming to IS-694, 1990 drawn through and including stove enamelled steel conduit (ISI marked) of suitable size (minimum 20mm dia) Concealed in walls, ceiling etc with all fittings and accessories (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 2.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point including cutting chases in brick walls for conduits and 1.6 mm thick mild steel sunken terminal boxes of suitable size including white cover plate of suitable module with frame for mounting modular switches, sockets etc complete for one 5/15 Amps Switch socket combination on Independent board complete all as specified and directed by the Engr-in-Charge. (Note: Cost of cutting chases and making good of the same for concealed wiring shall deem to be included in the unit quoted rates) |
| 37 | S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. |
| 38 | S & F Modular socket outlet (shuttered) 6A, 2/3 pin combined, 2 module complete all as specified and as directed. |
| 39 | S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. |
| 40 | S & F Modular socket outlet (shuttered), 6A/16A, 2/3 pin combined, 2 module complete all as specified and as directed. |
| 41 | S & F modular bell push 6 am, 1 module,complete all as specified and as directed. |
| 42 | S & F Buzzer electric, AC 230 Volts, single pole complete all as specified and as directed. |
| 43 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 44 | S & F LED lights fitting 1x 20W, 220V, AC (4ft), high performance electronic driver, operating temperature 10° C to 35°C, operating voltage range 140 V - 270V, average life 50000 hours and LED lamp including High efficiency long life LED with lumen efficacy of 140 lm/watts and ABS end caps tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with all accessories complete all as specified and directed. (Make: Havells Cat Part No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or equivelant of make as per list of manufacturer's) |
| 45 | S&F IP>=20 class I recess mounting LED square shape slim ceiling light fitting 42W or next higher rating CRI>=80 ,CT>=5700 K.suitable for 600x600 mm (Approx demensions) suitable for modular grid/Armstrong ceilings integrated type, with high efficiency electronic driver ,surge suppressor of 2 KV or more and high brightness LEDs luminaire efficacy>95 lumens/watt,power factor >=0.90 operating range - 140 to 270 V,50Hz with suitable fixing arrangement with suitable fixing arrangement complete with accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size complete all as specified and directed including taking down old/unsv fittings. (Make: cat part No. VENUSNEOHE2XxR42WLED 865 MODUGR 19 of make Havells or equivelant of make as per list of manufacturer's) |
| 46 | S & F Ultra modern, decorative rectangular shapped LED, IP66, LED Radiant step light of 7W, 3000K black housing, CRI>=80, suitable for fixing in step with high efficiency driver, surge suppressor of 2 KV or more & high brightness LEDs with Min 120 lumens/Watt output, power factor >= 0.90, operating range - 140 to 270 V, 50 Hz with suitable fixing arrangement complete with all accessories internally pre-wired and including connecting up with and including three core twisted flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells Cat Part No. LHEOABP5I46H007 or equivelant of make as per list of manufacturer's) |
| 47 | M & L for Sub main wiring with 2 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- (i) Two runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 48 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper conductor cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 49 | M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper conductor cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) |
| 50 | M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) |
| 51 | S & F Distribution board (vertical load line DB), double door made out of CRCA mild steel sheet, surface with insulated materials like polyester or with epoxy powder coating and IP43 & IK 09 protection conforming to IS 8623-1 & 3, IEC 61439- 1 & 3, VTPN, 12way, 415 Volts with copper bus bar of rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connection complete all as specified and as directed. |
| 52 | S & F Distribution board (vertical load line DB), double door made out of CRCA mild steel sheet, surface with insulated materials like polyester or with epoxy powder coating and IP43 & IK 09 protection conforming to IS 8623-1 & 3, IEC 61439- 1 & 3, VTPN, 8way, 415 Volts with copper bus bar of rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connection complete all as specified and as directed. |
| 53 | S & F wall trunking system of size 210mm width x 60mm height and to accommodate power, data, communications cables and other acessories as required at site and provide cover made of lead free PVC, inflamable self fire extinguishable, standard length of 2m suitable for fixing wiring devices with the support of back box and cover plates, the base of the trunking shall have perforations of anchoring, railing clip, end cover, T-section etc with provision to facilitate partition for routing power and data cables seperately complete all as specified and directed. |
| 54 | S & F MCCB 415 Volt, 16 KA, 4 Pole, 125 Amps rating (Ics=100% of Icu) with adjustable overlaod and adjustable short circuit setting, thermal magnetic release complete all as specified and as directed . |
| 55 | S & F MCCB 415 Volt, 16 KA, 4 Pole, 100 Amps rating (Ics=100% of Icu) with adjustable overlaod and adjustable short circuit setting, thermal magnetic release complete all as specified and as directed |
| 56 | S & F MCCB 415 Volt, 16 KA, 4 Pole, 63 Amps rating (Ics=100% of Icu) with adjustable overlaod and adjustable short circuit setting, thermal magnetic release complete all as specified and as directed . |
| 57 | S & F 415V 10KA, 'C' curve miniature circuit breaker (MCB), TP 25 to 63A of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed |
| 58 | S & F 415V 10KA, 'C' curve miniature circuit breaker (MCB), TPN 16 to 32A of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed |
| 59 | S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 with 200 Amps rated bus bar and blanking plates, neutral link complete all as specified and as directed. |
| 60 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection, IK 09 with 200 Amps rated bus bar and blanking plates, neutral link complete all as specified and as directed. |
| 61 | Supply and fixing SPN, 32 Amp rating, 240V, 10KA, 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning complete all as specified and as directed |
| 62 | Supply and fixing SP, 6-32 Amp rating, 240V, 10KA, 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning complete all as specified and as directed |
| 63 | S & F RCBO for earth leakage protection, Double pole, 30mA, 32 Amps capacity, 240V complete all as specified and as directed |
| 64 | S & F Rigid non-metalic PVC conduit (25mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. |
| 65 | S & F 40mm dia Rigid non-metalic PVC conduit exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. |
| 66 | Taking down AC of any type/capacity after disconnecting all electrical connections and disconnect the indoor, outdoor unit etc with all accessories and depositing at MES store yard in safe condition and re-fixing the same in existing position including re-filling of gas and replacement of damaged copper pipe and insulating materials, drain out pipe etc complete all as specified and directed. (Note: The unit quoted rate shall deem to include transpoirtation of AC to MES store yard and back for re-fixing) |
| 67 | Disconnecting and taking down carefully existing exhaust fan of 250 to 300mm from it's existing position including louver and deposited MES store yard complete all as directed by the Engr-in-Charge. |
| 68 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately) |
| 69 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately) |
| 70 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed. |
| 71 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard/dense soil complete all as specified and directed. |
| 72 | Removing excavated soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 73 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 74 | Supply and laying well burnt sub class 'B' bricks, old size laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed. |
| 75 | S & F in repair 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain/fixed to pole etc with all fixing accessories as in cable protection complete complete all as specified and directed. |
| 76 | M & L for cutting existing roads/ hard standing/ path etc for laying LT cables through pipes of any size n.exc 45cm depth and 25cm width and making good the damaged surfaces complete as per the existing specifications of roads/ hardstanding/ path etc to match with the existing surfaces complete all as specified and directed. |
| 77 | Taking down existing panel board of any size and descriptions after disconnecting all electrical connections with all fittings/accessories and depositing at MES store yard in safe sondition complete all as directed by the Engr-in-Charge. (Note: The cost of transportation to MES store yard shall deem to include in the unit quoted rate) Total in Figures 0.0 0.0 Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |