Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 4 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 6 | Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 8 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Providing Toe steel reinforcement of 8mm dia rods as approved |
| 13 | Providing Toe steel reinforcement of 10 mm dia rods as approved |
| 14 | Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Suspended floors, roofs, landings, balconies and access platform |
| 19 | Weather shade, Chajjas, corbels etc., including edges |
| 20 | Stairs, (excluding landings) except spiral-staircases |
| 21 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an |
| 22 | Providing 50mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 23 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. |
| 25 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 26 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 27 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 30 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 31 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 32 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour tiles. |
| 33 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 34 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm |
| 35 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 36 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flat/ Square as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 37 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 38 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 39 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 40 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 41 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 42 | Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 43 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 44 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 45 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 46 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps :- (a) Surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jel including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 47 | (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand: Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder - Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4N/mm2 (According to FIP 5.15) Elongation at Break ~35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) |
| 48 | (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamfered vrith 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral |
| 49 | mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc. Warrenty for five years. |
| 50 | Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.-There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+ |
| 51 | Covering of treated surface with PCC : Providing 50 mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with admixture of integral water proffing and placing in position, skirting curing, taxes and royalty all complete as per building specification and direction of E/I. Panels that has been left should be casted next day. there should be 6mm gap between Panels Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X421 ic Dr. Fixit Pidiproof LW+ |
| 52 | Providing and filling of 6mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST).Brand:-Sika Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent. |
| 53 | Providing and filling of 6mm thick Groove between 50mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of E/I. (with 18% GST) Brand - Sika-Polysulphide, Forsoc-thioflex 600, Dr. Fixit Pidiseal PS (42P, MYK Seal PS or Equivalent. |
| 54 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 55 | Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 56 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 57 | Providing 1.5mm cement punning including curing, carraige of water with all leads and lifts as per building specification and direction of E/I. |
| 58 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 59 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 60 | Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 61 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 62 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 63 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 64 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 65 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 66 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 67 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer |
| 68 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) |
| 69 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.) |
| 70 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 71 | Providing and laying in Position Cement of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand (zone-lll) :6 gradde stone aggregate 40 mm nominal size) |
| 72 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 73 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 74 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 1 2 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 75 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 76 | Ridges plain (500 - 600mm) |
| 77 | Flashings/ Aprons.( Upto 600 mm) |
| 78 | Gutter (600 mm over all girth) |
| 79 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 80 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 81 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 82 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and Tiron guide at the top and bottom respectively, including applying a priming coat of approved steel primer |
| 83 | Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I. |
| 84 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, complete as the direction of Engineer -in-Charge. |
| 85 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 86 | Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 87 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1 : 4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 88 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size) |
| 89 | Extra for providing and fixing 30X4mm glass strips in joints of flooring , complete job as per specification and direction of E/I. |
| 90 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 91 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 92 | Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied withG.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately) |
| 93 | Supplying fitting & fixing Angle iron post(b) Angles size in mm as per I.S. 226 |
| 94 | Rough dressing the trenched ground including breaking clods. |
| 95 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation |
| 96 | Fine dressing of the ground. |
| 97 | Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). |
| 98 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 99 | Mixing earth and sludge or manure in the required proportion specified ordirected by the Officer-in-charge |
| 100 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60 mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge |
| 101 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. |
| 102 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 103 | Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. |
| 104 | Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm ht., in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge. |
| 105 | Providing and Displaying Travelers palm well developed with fresh & healthy leaves foliage 210 to 240 cm ht specimen in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 106 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 107 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 108 | Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50 m : Common burnt clay F.P.S (non modular) bricks of Class designation 7.5 |
| 109 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water |
| 110 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge |
| 111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. |
| 112 | 15 mm nominal dia Pipes |
| 113 | 32 mm nominal dia Pipes |
| 114 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 115 | Providing P.C.C. M-200 in foundation with nominal mix of (1:1.5:3) with approved quality of stone metal 50 mm to 40 mm size graded and local river sand (washed and screened) including shuttering, screening, mixing cement concrete in mixer and placing in position, vibrating, striking, curing taxes and royalty all complete as per building specification and direction of E/l. |
| 116 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25. |
| 117 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 118 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 119 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 : 4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. Size of Tile 1200 x 1200 mm |
| 120 | Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.:15 mm nominal bore. |
| 121 | Providing and fixing PTMT Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, Weighing not less then 106 gms. |
| 122 | Providing and fixing C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms |
| 123 | Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings. |
| 124 | Supplying, fitting and fixing CP brass towel rail 20 mm x 600 mm with bracket container |
| 125 | Providing and fixing c.p. towel ring complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Mark or equipment) |
| 126 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 127 | Extra for pre finished nosing to treads of steps of marble stone. |
| 128 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 129 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 130 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 131 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 132 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 133 | Supplying, fitting & fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 134 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick |
| 135 | Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. |
| 136 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 137 | Supplying and laying (properly as per design and drawing) rip-rap with good quality of boulders duly packed including the cost of materials,royalty all taxes etc.but excluding the cost of carriage all complete as per specification and direction of E/I. |
| 138 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 139 | Bricks - 8km (1k + 7p) |
| 140 | Sand - 30km |
| 141 | Chips -20km |
| 142 | Metal - 20km |
| 143 | Fly Ash Brick - 15km |
| 144 | Carrage of Earth -3 km |
| 145 | Boulder (22km) |
| 146 | Point wiring in PVC conduit, with modular type switch - Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required Group C |
| 147 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 148 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 149 | 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 150 | 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 151 | 2 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire |
| 152 | 4 x 6.0 sq.mm. + 2 x 6.0 sq.mm. earth wire |
| 153 | 4 X 16 sq. mm + 2 x 6 sq.mm Earth Wire |
| 154 | 4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire |
| 155 | 2 X 4 sq. mm + 1 x 4 sq.mm Earth Wire (Sockets) |
| 156 | Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 4 sq.mm. |
| 157 | TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required. |
| 158 | S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20mm |
| 159 | S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 75mm x 75mm x 50mm deep/(4\\" x 4\\") |
| 160 | S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. |
| 161 | 5/6 amps, one way switch |
| 162 | 15/16 amps, one way switch |
| 163 | 3 pin 5/6 amps, socket outlet |
| 164 | TV antenna socket outlet |
| 165 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 166 | Supplying and fixing Modular type blanking plate-Supplying and fixing modular blanking plate on existing modular plate switch box excluding modular plate etc. as required. |
| 167 | Supply & fixing 20A SPN MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for socket out let and complete with connections, testing and commissioning etc as required. Make : L&T/ABB/Legrand/Polycab/Philips |
| 168 | Providing & fixing : Porviding and fixing of MV danger notice plate of 200mmX150 mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 169 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 5 pin, 5/6 amps socket outlet and 5/6 amps piano tyep switch connection, painting etc. as required. |
| 170 | S/F power plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as requird. |
| 171 | S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 172 | S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required. |
| 173 | ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit. |
| 174 | ITC Fluorescent fitting with down rods - Installation, testing and commissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20mm dia stee. |
| 175 | ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required. |
| 176 | ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 177 | S/F MCCB in cubical panel board: Supply and fixing following rating & capacity 4pole MCCB in existing cubicle panel board. Including drilling holes in panel , making connections etc as required. |
| 178 | 25 to 100A, 16kA fixed thermal rating( to be used as incomer for light & UPS SDB as floor, wall mounted panel) |
| 179 | 125A, 16kA fixed thermal rating( to be used as incomer for tap off bay of rising mains) |
| 180 | 160A, 35kA fixed thermal rating( to be used as incomer for SDB as floor wall mounted panel) |
| 181 | 200A, 35kA-(5 nos )fixed thermal setting with spreader links( to be used as incomer for tap off box of rising mains & 1 no for UPS room SDB) |
| 182 | S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, double door |
| 183 | S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 184 | 4 way (4 + 12), Double door, Horizontal type |
| 185 | 6 way (4 + 18), Double door, Horizontal type |
| 186 | 8 Way (4+24) Double Door, Horizontal type |
| 187 | S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required. |
| 188 | 6/32 amps, Single Pole |
| 189 | 40 amps, TPN |
| 190 | 40 amps, DP |
| 191 | 50/63 amps, DP |
| 192 | 63A rating, TPN MCB, \\"C\\" curve 10 KA breaking capacity. |
| 193 | 6/32A rating, SPN MCB, \\"C\\" curve 10 KA breaking capacity. |
| 194 | S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required |
| 195 | 40 amps |
| 196 | 80/100 amps |
| 197 | Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt) |
| 198 | S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required |
| 199 | P/F GI lightning conductor final - Providing and fixing of GI lightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate base including holes etc. complete as required. |
| 200 | P/F G.I. lightning conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 201 | P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 202 | MV cable laying upto 120 sq.mm. in ground without sand and cover - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering. |
| 203 | MV Cable :- Supply of ISI marked aluminium cable conductor XLPE PVC Insulated Cable as per I.S :7098 armoured , served shaelthed 1100V grade with Termination and laying of cable . |
| 204 | 3.5c x 70 sq.mm |
| 205 | 3.5c x 95 sq.mm |
| 206 | Supply of ceiling fan :- Supplying and fitting of 1400mm sweep regular /standared model AC fan , including connection with 1.5 sqmm copper wire down rod of standered length ( upto 30cm ) with all acessories as required |
| 207 | Supply of Exhaust Fan :- Supply and fitting of 300 mm , 230V AC metal exhaust fan in the existing opening including making good the damage , connection testing commisioning etc as required |
| 208 | Led tube with batten 20W/22W :- Supply and fixing of wall mounted LED 20W/22W tube+ batten electronic driver and acessories as required . |
| 209 | 16\\" (400 mm ) Wall Mounted Fan |
| 210 | Led bulb 9W/10W :- Supplying and fixing of LED 9W/10W bulb and acessories as required . |
| 211 | 15/16W Led Round Down Light |
| 212 | 1' X 1' LED Panel Light |
| 213 | 2' X 2' LED Panel Light |
| 214 | 90/100 W LED Flood Light |
| 215 | S.I.T.C of following rating recess/surface mounting round/square shape downlight with pressure die cast housing for single phase supply voltage. Luminaire shall conform to IS:3022 part-5/ section-5 or IEC:62722 with all necessary accesories as required. 80W LED Flood light |
| 216 | Supply, fitting, fixing and testing of 1200mm Sweep, BLDC, 5Star Fan.32 W |
| 217 | Supplying and fixing following size/ modules G.I. box along with modular base & cover plate for modular switches in recess etc as required. |
| 218 | 4 module (78mm x 140mm x 50mm) |
| 219 | 12 module (135mm x 205mm x 60mm) |
| 220 | Earthing with G.I. earth pipe 4.5mtr. long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required. |
| 221 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc., as required. |
| 222 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including soldering etc. |
| 223 | Earthing with G.I. earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 224 | Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 225 | Laying of one nùmber PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 226 | 1.1 KV Cable End Termination:- Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. |
| 227 | 3.5c x 95 sq.mm (45mm) |
| 228 | 3.5c x 70 sq.mm (38mm) |
| 229 | Supplying and fixing following rating four pole, (three phase and neutral) 415 volts, residual circuit breaker (RCCB) having a sensitivity current 30 milli amperes in the existing MCB DB complete with connection, testing & commissioning etc. as required. |
| 230 | 25 amps |
| 231 | 40 amps |
| 232 | S.I.T.C of following rating LED Street lighting luminaire with pressure die cast housing and toughened glass cover, IP66 protection, luminous efficacy >10LM/W with lens in existing pipe/pole for supply voltage 100-270V AC, 50Hz.Luminaire shall conform to IS:3022 part-5/ section-3 and shall be complete with all necessary accesories as required. 70W LED street light |
| 233 | Supply of 9 metre hot dip galvanised Octagonal pole(BOP-9031) with top dia 70mm, bottom dia 130mm & made of 3 mm thick sheet, base plate dimensions 200 x 200 x 12 mm(LXBXT) including suitable sizes of foundation bolt all complete as reqd. (without arm) |
| 234 | Supply of 1m single arm suitable for 70mm top |
| 235 | Supply of 1m double arm suitable for 70mm top |
| 236 | Installation, testing & ommissioning of 9 mtr high octagonal pole & light fitting with the help of suitable tools and plants, wiring of luminaires with all materials and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity of 10T/sq.mtrs. |
| 237 | S.I.T.C of following rating LED floodlight fitting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminaire shall conform to IS:3022 part-5/ section-5 or IEC:62722 with all necessary accesories as required. 150W LED Flood light |
| 238 | S.I.T.C of following rating approved make LED bollard fitting with cylindrical shape and inverted cone shape head of height 600 to 850mm power input 8/9 watt with die cast aluminium housing opel with PC diffuser, IP:65/54 protection, conferming to IS:10322 part 5 etc all complete as required. (excluding plinth charges) |
| 239 | Supply, installation, testing & commissioning of 12M high mast shaft in two sections construction S356 grade as per BS-EN 10025 top dia 100 mm , bottom dia 360mm, plate thickeness 3mm, 12 side polygen, galaisation as per BS EN ISO-1461, base plate dia 520 mm , base plate thickness 25mm, GI single spike lightning protection, suitable for 47 m/sec with 6 number foundation bolts of PCD 445mm TS600/24mm dia/850mm long.Luminaries carriage: Material for 40 NBERW class B-MS pipe,dia of carriage ring- 450mm (ID) with 8/12 arm, welded, 2 section having carrying capacity upto 8 luminaries. Trailing cable: 5C 2.5 sq mm. PBC flexible copper conductor. Winds/power tool: Double drum, SWL 350 kg with 0.75 HP 6 pole single speed integral motor. Rope; grade aisi 304,7/19 construction,dia 5 mm, BLC 1450x2 having 2 numbers of continuous rope. Aviation construction light: twin dome aviation obstruction lights LED type as required. Feeder pillar ,control panel housing 63 A TPN MCB incomer, single dial timer, 45 A contractor circuit for automatic control of luminaries power tool control with 2 number 9A contractor and raise lower push button, incoming 35 sq mm and outgoing 16 & 2.5 sq mm terminals. |
| 240 | Outdoor stand mounted feeder pillar panel with 32A MCB TP&N as incomer , 45A TP contactor , automaic switching of luminaries, power tool control incomer outgoing terminals etc required for highmast. |
| 241 | MAIN LT PANEL FOR SCHOOL CAMPUS Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Indoor Type Main Distribution Board fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing , dust and vermin proof, (degree of protection-IP54)with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) as per Specification. |
| 242 | The Main LT Panel shall broadly comprise of the following equipment/components) Incoming Feeders:- Incomer-160A, TPN MCCB (P-2), 35 kA for 1 sec (Ics=100%Icu) Breaking capacity (Variable thermal rating 80-100%, variable magnetic rating 6-10 times) with factory made silver plated copper spreading links- 3 Nos. (AC Mains + DG I/C + Changeover) Outgoing Feeders:- 125A TPN MCCB 16kA - 01 No. 63A TPN MCCB 16kA - 02 Nos. 200A TPN Copper bus bar in metal encolsure with fixing clamps Indication lamps(On- Off Trip Power On -- RYB) Supplying, Installing, Testing & Commisioning cost of Main LT Panel for School Campus all complete with all necessary items as per direction of E/I. |
| 243 | MAIN LT PANEL FOR G+2 SCHOOL BUILDING Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Indoor Type Main Distribution Board fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing , dust and vermin proof, (degree of protection-IP54)with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) as per Specification. |
| 244 | The Main LT Panel shall broadly comprise of the following equipment/components) Incoming Feeders:- Incomer-160A, TPN MCCB (P-2), 35 kA for 1 sec (Ics=100%Icu) Breaking capacity (Variable thermal rating 80-100%, variable magnetic rating 6-10 times) with factory made silver plated copper spreading links- 1 No. Outgoing Feeders:- 40A TPN MCB 10kA - 04 Nos. 63A TPN MCB 10kA - 04 Nos. 63A TPN MCCB 16kA - 01 Nos. 200A TPN Copper bus bar in metal encolsure with fixing clamps Indication lamps(On- Off Trip Power On -- RYB) Supplying, Installing, Testing & Commisioning cost of Main LT Panel for G+2 School Building all complete with all necessary items as per direction of E/I. |
| 245 | Outdoor Feeder Panel ( for street light and High mast): Supplying, designing, manufacturing, installation, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing of outdoor type cubical feeder pillar of suitable size not less than 30 cm and up-to 45 cm deep made out of M.S. sheet 2 mm thick (14 SWG) duly compartmentalized, double door with locking arrangement (IP-54), duly fixed on MS angle iron frame work of suitable size ,earthing with two nos. earth studs, powder coated with rain shed structure etc as reqd. All inter connections shall be made with 2.5, 4 , 6 Sq mm PVC Cu. wire. The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs |
| 246 | Incomer : 1 No. 100A/FP/16kA/ MCCB thermomagnetic release type, and S/C, O/L protection, with Rotary Handle & Spreader links. Outgoings: MCB 40 A, TPN, 10kA - 6 nos. for highmast, street lights & bollard lights 40 amp 4P Duty contactor 0-24hrs Timer switch with bypass arrangement 100 amp 415 V heavy duty three phase with neutral busbar chamber Indicator switch, selector switches, CT, PT, RYB Lamps and Voltmeter, Ammeter etc |
| 247 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 580mm. long - with 10 litre low level PVC cistern |
| 248 | Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \\"P\\" trap (b)10 lit. low level P.V.C. cistern |
| 249 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. Flat back or standard corner (600mm x 350mm) |
| 250 | Bib Cock ( ISI Marked ) |
| 251 | Bib Cock ( Long Thread ) ( ISI Marked ) |
| 252 | Soap Disk |
| 253 | Central hole basin mixer ( ISI Marked ) |
| 254 | 15 mm C.P. extentsion Nipples |
| 255 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. (i) 600mm X 450mm size |
| 256 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I. |
| 257 | 100 mm dia steel jali |
| 258 | Providing and fixing 15mm dia and 45cm. Long P.V.C. Connection pipe with heavy quality brass coupling at both ends etc. All complete as per specification and direction of Engineer-in-charge. |
| 259 | Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 260 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the wall etc.. |
| 261 | 20 mm nominal outer dia Pipes |
| 262 | 25 mm nominal outer dia Pipes |
| 263 | 15 mm nominal outer dia Pipes |
| 264 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 265 | 25 mm nominal outer dia Pipes |
| 266 | 32 mm nominal outer dia Pipes |
| 267 | 40 mm nominal outer dia Pipes |
| 268 | Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I. |
| 269 | Angular Stop Cock ( Long Thread ) ( ISI Marked ) |
| 270 | Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri ) with cover & locking system |
| 271 | Towel Rail 24\\" |
| 272 | Towel Ring |
| 273 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178 mm |
| 274 | Providing and fixing N.P/ C.P. Brass/ P.V.C. Porcelain shower rose of 15mm inlet etc. All complete as per specification and direction of E/I. (c) 150mm dia C.P. Shower |
| 275 | provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc. |
| 276 | provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc. |
| 277 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 278 | 75 mm Coupler |
| 279 | 110 mm Coupler |
| 280 | 75 mm Single pushfit Coupler |
| 281 | 110 mm Single pushfit Coupler |
| 282 | 75 mm Single tee with door |
| 283 | 110 mm Single tee with door |
| 284 | 75 mm Single tee without door |
| 285 | 110 mm Single tee without door |
| 286 | 75 mm Bend 87.5° |
| 287 | 110 mm Bend 87.5° |
| 288 | 75 mm Shoe (Plain) |
| 289 | 110 mm Shoe (Plain) |
| 290 | Providing and placing on terrace (at all floor levels) polyethylene Water Storage Tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 291 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm |
| 292 | 32mm dia. PVC waste pipe 750mm long with cushion |
| 293 | 15mm C.P. nipple with coupling |
| 294 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 450mm x 300mm |
| 295 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole |
| 296 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 297 | (a) From 0.00 M to 50.00 M below G.L. |
| 298 | (b) From 51.0 M to 150.00 M |
| 299 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 300 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 301 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 302 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 303 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP |
| 304 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 305 | STARTER D.O.L starter with SS Enclosure with 380/415 Volt coil 5 to 10 HP |
| 306 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 307 | Add 18 % GST |
| 308 | Add 1% Labour Cess Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail