| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Certain repairs to roof treatment, sunken, roof sheet and ceiling at zone C and zone D under GE kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs . |
| 3 | M&L for 40 mm thick cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) as in PCC padding over roof slab complete all complete all as specified. |
| 4 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compoundNote :- WPC to be measured and paid seprately |
| 5 | Preparation of newly plastered surfaces making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) and applying two coats of aluminium paints complete all as specified and directed. |
| 6 | M&L for 40mm thick brick tiles bedded in cement mortar 1:4, 15mm thick as on roof over APP complete all as specified and directed by Engr-in-charge. |
| 7 | - ditto - all as per item No. 5 abovr but except tiles complete all as specified and directed. |
| 8 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as specified and directed by Engr-in-charge. |
| 9 | M&L for cement concrete type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs, rounded or chamfered edges complete all as specified . |
| 10 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 11 | M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 12 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 13 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards etc any thickness . |
| 14 | S&F in position suspended false ceiling system using E-grid suspended ceiling grid system . The size of grid shall be 600x600mm with GI frame work main runner 38x24mm cross tee 25x24mm and wall angle 24mmx24mm using 9mm thick ceiling panel laminated wth PVC film on front face and foil back available in due drop texture as per IS- 2095 Part-I 1996 fixed in the grid of E grid suspended ceiling Grid system duly suspended by 4mm dig GI bar hangers from the purlins of the roof with butter fly clips all as specified. |
| 15 | M&L for steel work in tabular trussess including special shaped washer etc complete using ERW or inductrion butt welded tubes conforming to IS 1161-1979 grade St-240 all as specified and direcvted by Engr-in-charge |
| 16 | Disconnecting existing tanks exc 250 & n.exc 500 Ltrs, setting aside (or owering if required)for repairs, cleaning, etc and hoisting if requiired reconnecting and re-fixing in position.(Cleaning repairing, etc measured sep[arately. |
| 17 | Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge. |
| 18 | S&F of GI tubing 15mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors. |
| 19 | Taking down GI tubing & connection 20mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge. |
| 20 | S&F of GI tubing 20mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors. |
| 21 | Dismantiling water tank PVC 500 Ltrs and removing from site |
| 22 | Dismantiling water tank PVC 1000 Ltrs and removing from site |
| 23 | S&F of rotational moulded polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 500 ltrs capcity incl fittings and as directed by Engr-in-Charge |
| 24 | S&F of rotational moulded polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 1000 ltrs capcity incl fittings and as directed by Engr-in-Charge |
| 25 | S&F of gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 20mm fixed in repairs. |
| 26 | M&L for water proofing treatment to sunken floors of kitchen, toilets, laboratories,bath and WC's etc shall be as under:- |
| 27 | (i) Application of Two component acrylic modified cementitious coating.(a) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement litance, existing coatings and achieve a gripping profile that is clean, dry and free from litanceand any other form of surface contamination. the installation instructions in manufacturer's published literature should be strictly compiled with, including but not limited to the following:-(b) Chipping out any visible cracks in ' V- Groove' pattern as applicable. Special attention on this part cleaning of cracks and then filling those cracks with SIKA latex SBR 100 putyy/ Dr Fixit 302 SBR latex/ perma latex SBR / FOSROC Nitibond SBR latex/ Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush and vaccum pressure if required.(c) Dampen all surfaces immediately ahead of application of Acrylic modified cemetitious coating of Sika Top seal - 107/brush Bond FOSROC/ Dr Fixit/ STP/ CICO.(d) While the surface is still damp from saturation (SSD), apply one coat of acrylic modified cementitious coating of Sika Top seal- 107/ Brush bond FOSROC/ Dr fixit / STP/ CICO of viscosity as per manufacturer's instructions.(e) Apply glass fabric sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP while the first coat is wet.(f) Once touch dry apply second coat of Acrylic modified cementitious coating of Sika Top Seal- 107/ Brush bond FOSROC/ Dr FiXit/ STP/ CICO of viscosity as per manufacturer's instructions on the entire area.(g) Second coat shall be applied after 6-8 hrs of application of previous coat and in the direction right angle to the previous coat.(h) The waterproofing coating should be taken to a height minimu 300mm above the finished floor level on the vertical surface.(j) It is essential to cure acrylic modified cementitious coating immediately after application ( minimum 6-8 hrs drying) for a minimum of 3 to 54 days to ensure full cement hydration and to minimize cracking. |
| 28 | (k) A protection plaster ( 12-15 mm thick) in cement mortar 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls.(l) Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika plastocrtete over the applied water proofing coating on horizontal surfaces.Admixutre for item( k&l) above : Sika Plastocrete Plus/ FOSROC/ Dr Fixit/ STP/ CICO confirming to IS 2645(m) All the corners and joints should be pretreated with elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of make Sika Seal Tape S/FOSROC/Dr Fixit/STP.(n) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.(o) waterproofing treatment has to be carried out through applicators authorised.(ii) All the joints of pipesand traps within sunken portion shall be selaed properly by Epoxy sealant.(iii) All CI traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) all - round.(iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40 mm stone aggregate) complete all as specified.(v) Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed.(vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5 mm grade stone aggregate as in flooring for laying floor finish all as specified.Note :- Item (iv),(v) & (vi) above shall be measured and paid seprately. |
| 29 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 30 | M&L for providing PVC pipe as spout pipe heavy class of dia 40mm all as specified and directed by Eng-In-Charge |
| 31 | M&L for providing PVC pipe as over flow pipe heavy class of dia 40mm including all fittings and fixtures complete all as directed by Eng-In-Charge |
| 32 | S&F of 40 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge. |
| 33 | M&L for PCC (1:5:10) type E2 using 40mm graded aggregate thick as in mass concreting, filling, sub base complete all as specified and directed by Engineer-in-charge. |
| 34 | M&L for PCC type B-0 (1:2:4) (12.5mm stone graded aggregate), 40 mm thick as for receiving top finishing layer of ceramic tiles for sunken portion finished even and smooth etc complete all as specified and directed. |
| 35 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles including 15 mm thick cement screed bed in cement mortar (1:6) and including dismantling of tiles Complete all as directed by Engineer-in-Charge. |
| 36 | S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat back closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, jet spray necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacity make white in colour and PVC flush pipe 32mm dia complete. |
| 37 | S&F of PVC flushing cistern low level of capacity of 10 ltr, white, valve less symphonic action type complete with inlet ball valve float and handle or Push button type including brackets and fixed in repair complete all as specified & directed. |
| 38 | Taking down cement plaster on brick work or concrete surfaces incl racking out joints all as specified. |
| 39 | M&L for 15mm thick rendering on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 with water proofing compound complete all as specified and as directed.Note: water proofing compound shall be measured and paid seprately. |
| 40 | Supply only liquid water proofing compound. |
| 41 | M&L for applying two coats of cement base paint on newly plastered or unplastered wall surface over a coat of cement primer including preparation of surfaces, complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |