| 1 | M&L for Cement Concrete Type B1(1:2:4) using 20 mm Grarded Stone aggregate as in Sub Base of Flooring and finishing the surface even and smooth without using extra cement (including demolition of cement concrete in ground floors and pavings including existing waterproofing treatment n.exc 15cm thickness complete all as specified & directed by Engineer-in-charge. |
| 2 | M&L for Hardcore of gauge n exc. 63 mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in-charge. |
| 3 | Taking down shutters of any description exc 1sqm but not exc 2.00 sqm each complete all as specified & directed by Engineer-in-charge. |
| 4 | S & F Factory made ISI marked flush door shutters 35mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 4 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf(f) Sun mica sheet as approved by Engineer-in-charge of suitable design on both sides of shutter. |
| 5 | M & L for plain sheet glass plain 3mm thick ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane including hacking out of old/broken glass complete all as specified & directed by Engineer-in-charge. |
| 6 | M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 including demolition of brickwork or stone/ boulder/block masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge. |
| 7 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified & directed by Engineer-in-charge. |
| 8 | S&F chicken mesh wire netting 25 gauge supplied and fixed on wall ceiling with nails complete all as specified & directed by Engineer-in-charge.Note : Rate of scaffolding upto 4 stories buidling include in this rate. |
| 9 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with approve make by adding 17-19% of potable water by weight of material. For thickness above 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified & directed by Engineer-in-charge.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height. |
| 10 | M&L for rendering 5-10 mm thick readymade plaster on inner/outer walls and Ceiling with approved make by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified & directed by Engineer-in-charge.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height. |
| 11 | Material & Labour for distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified & directed by Engineer-in-charge. |
| 12 | M&L for preparing of new plaster surface and applying three coat of white wash on newly plaster surface of ceiling complete all as specified & directed by Engineer-in-charge. |
| 13 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed by Engineer-in-charge. |
| 14 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or unplasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and Applying Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification one coat on old Surface complete all as specified & directed by Engineer-in-charge. |
| 15 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge. |
| 16 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or unplasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying One coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over Old Surfaces complete all as specified & directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 17 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or unplasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying One coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over Old Surfaces complete all as specified & directed by Engineer-in-charge. Please Enable Macros to View BoQ information |