| 1 | Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and separating serviceable fittings for reuse in the same work and removing unserviceable fittings under sch of credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, ceiling etc, complete all as per specified and as directed by Engineer-in-charge. |
| 2 | Taking down DB's including MCB's etc., complete all as per specified and as directed by Engineer-in-charge. |
| 3 | Taking down carefully unserviceable sub main wiring of any size / core / type including making good the disturbed surfaces, complete all as specified and as directed by Engineer in Charge. |
| 4 | M&L for Point wiring with PVC Conduit of required size confirming to IS-2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable FRLSH 1.5 Sq mm nominal cross sectional area 1100 volts grade complete with all fittings such as elbow, bends, junction box saddle, including PVC modular box sutaible for Modular switch/sockets etc ISI mark and screw and rawa plug etc including FRLSH 1.5 Sqmm PVC insulated copper conductor cable as earth wire including making good disturbed surface of walls & floors etc.for one light /Bell point controlled by one 5 Amp switch one way & and making good disturbed surface of walls & floors etc, complete all as specified and as directed by Engineer in Charge. Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code. |
| 5 | M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor FRLSH cable 1.5 Sq mm size 1100V grade in and including PVC casing caping double lock type of size not less than 25X16mm including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire (green coloured) connected to earth dolly complete for one light /Bell point controlled by one 5 Amp switch one way including factory made PVC modular/ non modular box sutaible for switch/sockets etc ISI marked and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer in Charge. Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code. |
| 6 | All as per serial item No. 05 above but for one light pointcontrolled by Two 2-way switches. |
| 7 | All as per serial item No. 05 above but for One socket outlet, 3 pin 5/6 Amps on same board. |
| 8 | All as per serial item No. 05 above but for One socket outlet, 3 pin 5/6 Amps, independent board. |
| 9 | All as per serial item No. 05 above but for Two socket outlet, 3 pin 5/6 Amps, independent board. |
| 10 | M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor FRLSH cable 2.5 Sq mm size 1100V grade in and including PVC casing caping double lock type of size not less than 25X20mm including one No. 2.5 Sq mm single core PVC insulated copper cable for continuous earth wire (green coloured) connected to earth dolly complete for socket outlet 15/16 Amps on independent board including factory made PVC modular/ non modular box sutaible for switch/sockets etc ISI marked and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer in Charge. Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code. |
| 11 | M&L for modular switch one way 6/10 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 12 | M&L for modular switch two way 6 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 13 | M&L for modular bell push 6 Amps 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 14 | M&L for modular socket, 6 Amps - 2/3 pin combined 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 15 | M&L for modular socket, 6 Amps / 16 Amps - 2/3 pin combined 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 16 | M&L for modular switch one way 16 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 17 | M&L for modular blank plate, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 18 | M&L for modular white cover plate with frame, 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 19 | M&L for modular white cover plate with frame, 3 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 20 | M&L for modular white cover plate with frame, 4 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 21 | M&L for modular white cover plate with frame, 6 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 22 | M&L for modular white cover plate with frame, 8 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 23 | S&F Bell Ding-Dong, AC, 230 V, Single Pole, complete all as specified and as directed by Engineer in Charge. |
| 24 | M&L for Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 25 | S&F in repair wall mounted LED Tube light fitting 20 watt surface mounted general purpose LED Batten in Extruded Aluminium housing including making connections with 2 core flexible copper wire 0.50 sqmm from ceiling rose after fixing fitting in position at site on 02 Nos new PVC blocks, complete all as specified and as directed by Engineer in Charge. Make - Havells Cat part No. - LUMILINEPLUSNEOBS20WLED865SPCSSIND or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 26 | S&F in repair wall mounted LED Tube light fitting 10 watt surface mounted general purpose LED Batten in Extruded Aluminium housing including making connections with 2 core flexible copper wire 0.50 sqmm from ceiling rose after fixing fitting in position at site on 02 Nos new PVC blocks, complete all as specified and as directed by Engineer in Charge.Make - Havells Cat part No. - LUMILINEPLUSNEOBS10WLED865SPCSSIND or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 27 | Supply and fixing in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten/angular fitting, complete all as specified and as directed by Engineer in Charge. |
| 28 | S& F in repair of Decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser/ acrylic diffuser suitable with 9 W LED lamp B22 base complete including dismantling the old one, complete all as specified and as directed by Engineer in Charge.Make : Cat Part No. LHFOAJE1Z1I060 of Havells or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 29 | S&F in repair of LED surface mounted decorative Bulk Head fittings 10 watts duly fixed on suitable PVC/ wooden Box and connection, complete all as specified and as directed by Engineer in Charge.Make : Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC of Havells or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 30 | S&F in repair of Bed side light fittings white or black in colour 3 watt, lumen output 400 lm/3000K minimum duly and complete all as specified and as directed by Engineer in Charge. Make : Cat Part No.- 48042 of Philips or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 31 | S&F in repair of LED surface/recess mounted 2x2 ft luminaire 36 Watt with high performance LEDs and made out of sheet steel housing suitable for armstrong/ grid/ pop ceiling etc incl all allied accessories and connection, complete all as specified and as directed by Engineer in Charge.Make : Cat Part No. VENUSTREND2X2PLR36WLED857SWH of Havells or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 32 | S&F in repair of bluiding security light new generation energy saving & enviornmental friendly, long life, versatile pressure die-cast aluminium, IP66 with high power LED as light source with acrylic cover of LED 30 Watt luminaire and suitable size of bracket, clamping with nut & fastener, complete all as specified and as directed by Engineer in Charge.Make - CAT Part No. -ENDURASUNDOWNSL30WLED757PASYBOPC of Havells or equivalent model of makes as mentioned in \\"List of Makes\\" of Particular Specification of the Tender Documents. |
| 33 | M&L for sub-main wiring with two single core 4.0 Sqmm PVC (FRLSH) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through non-metalic PVC casing caping (25x20 mm) with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and as directed by Engineer in Charge. Note : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit. |
| 34 | M&L for sub-main wiring with two single core 6.0 Sqmm PVC (FRLSH) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through non-metalic PVC casing caping (32x16 mm) with and including PVC insulated 6.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and as directed by Engineer in Charge. Note : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit. |
| 35 | S&F in repair Switch socket combination 2 in-1, 3 pin, 5/6A, flush type, 240 volts, complete all as specified and as directed by Engineer in Charge. |
| 36 | S&F in repair Switch Socket Combination 2 in 1, 3 pin, 15 Amp, flush type universal, 240 volts, complete all as specified and as directed by Engineer in Charge. |
| 37 | S&F in repair for modular switch one way 6/10 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 38 | S&F in repair for modular socket, 6 Amps - 2/3 pin combined 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 39 | S&F in repair for modular socket, 6Amps / 16Amps - 2/3 pin combined 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 40 | S&F in repairs for modular switch one way 16 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge. |
| 41 | S&F in repair/replacement of MCB DB, TPN 4 way, 415 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02. |
| 42 | S&F in repair/replacement of MCB DB, SPN 12 way, 240 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02. |
| 43 | S&F in repair/replacement of MCB DB, SPN 8 way, 240 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02. |
| 44 | S&F in repair/replacement of MCB, Single Pole, 240 volts of capacity 6-32 Amps, 10 KA rupturing capacity, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02. |
| 45 | S&F in repair/replacement of MCB, SPN, 240 volts, 50 Hz of capacity 40-63 Amps, 10 KA rupturing capacity, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02. |
| 46 | S&F in repair/replacement of MCB, TPN, 240 volts, 50 Hz of capacity 40-63 Amps,'C' curve, 10 KA rupturing capacity, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02. |
| 47 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |