| 1 | Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering, complete all as specified and as directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 4 | S&F galvanised,corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screw and washers in roofs, walls etc including dismantling of existing sheet , complete all as specified and as directed. |
| 5 | S&F 0.80 mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 120 gm including dismantling, complete all as specified and as directed. |
| 6 | Demolition of brick work, PCC block masonary, stone masonry or boulder masonary built in cement mortar, complete all as specified and as directed. |
| 7 | M & L for brick work with sub class 'B' bricks (old sizes) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified and as directed. |
| 8 | M&L for walling of random rubble masonary uncoursed, well bonded , bedded and solidly hearted built in CM 1:4, complete all as specified and as directed. |
| 9 | M&L for Cement concrete 1:2:4 type B1 (using 20 mm graded agg) as in coping including form work , complete all as specified and as directed. |
| 10 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 finished surfaces even and smooth without using extra cement with water proofing compound, complete all as specified and as directed.Note : WPC shall be measured and paid separately. |
| 11 | Supply only integral water proofing compound, complete all as specified and as directed. |
| 12 | Taking down cement plaster or screed bedding layer of any description from concrete slab/terrace surfaces etc including racking out joints hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 13 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced, complete all as specified and as directed. |
| 14 | M&L 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement, complete all as specified and as directed. |
| 15 | M&L for 75mm thick cement concrete Type C2 1:3:6 (using 40 mm graded aggregate) as in sub floors, sub bases, floors and pavings etc, complete all as specified and as directed. |
| 16 | M&L for Factory made precast coloured cement concrete interlocking tiles 60 mm thick of size and shape as directed, strength not less than that of M-35 grade concrete laid and jointed , complete all as specified and as directed. |
| 17 | M & L for 30 mm thick sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed. |
| 18 | M & L for cast-in-situ providing cement concrete 1:2:4 Type B-1 (using 20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed. |
| 19 | Dismantling floor hearth wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the permishes, complete all as specified and as directed. |
| 20 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 21 | M & L for glazed ceramic tiles in vertical surface 350x250x7mm/450x350x7mm thick colour and design (as approved) set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over 10 mm thick cement plaster in CM (1:4), complete all as specified and as directed. |
| 22 | Dismantling timber scantling 40 sq cm and over in section in any position as in unframed work, complete all as specified and as directed. |
| 23 | Dismantling timber scantling under 40 sq cm in section in any position as in unframed/framed work, complete all as specified and as directed. |
| 24 | M & L 2nd Class soft wood as in scantling, clean swan timber framed and fixed, complete all as specified and as directed. |
| 25 | M&L 2nd class soft wood 20 mm thick in facia/eaves boarding fixed with nails in any situation planed one side with butt joints, complete all as specified and as directed. |
| 26 | S&F plain fillets, square, rectangular or triangular in section using second class soft wood clean swan secured with nails exc 13 sqcm but not exc 25 sqcm in section, complete all as specified and as directed. |
| 27 | S&F plain fillets, square, rectangular or triangular in section using second class soft wood clean swan secured with nails exc 6 sqcm but not exc 13 sqcm in section complete all as specified and directed. |
| 28 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and as directed. |
| 29 | S & F 6 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work on Ceiling, complete all as specified and as directed. |
| 30 | S & F 6 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work on wall, complete all as specified and as directed. |
| 31 | M&L 2nd Class softwood weather boarding clean swan, plain 20mm thick or feather edges 15mm to 20 mm thick and fixed with 30mm over laps, complete all as specified and as directed. |
| 32 | M&L Wooden Flooring boarding, clean sawn, plain, 30mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps Planed one side, with butt joints and fixed with nails supplied and fixed, complete all as specified and as directed. |
| 33 | All as per above item no. 32 here-in-before but except boarding, complete all as specified and as directed. |
| 34 | Taking down chowkats with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc 4 Sqm each and offered as credit, complete all as specified and as directed. |
| 35 | All as per above item no. 34 here in before but n exc 1.5 Sqm each, complete all as specified and as directed. |
| 36 | Taking down shutters of any description area exc 1.00 Sqm and n exc 2 Sqm each, complete all as specified and as directed. |
| 37 | Taking down shutters of any description n.exc 1.00 Sqm each, complete all as specified and as directed. |
| 38 | S&F second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints , complete all as specified and as directed. |
| 39 | S&F Plain, framed, panelled moulded shutters, moulded on both sides thickness 30 mm of 1st class softwood, (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed. |
| 40 | S&F Glazed and skeleton shutters thickness 30 mm, second class softwood, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Section specified 8 clause 8.24(b) , complete all as specified and as directed. |
| 41 | S&F 150mm Extruded aluminium alloy handles, fabricated type polished, complete all as specified and as directed. |
| 42 | S&F Butt hinges,100mm medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 43 | S&F Aluminium alloy, anodised, 250mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts andsliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 44 | S&F Aluminium anodised, barrel tower bolts 150 mm of extruded section and fixed , complete all as specified and as directed. |
| 45 | S&F Powder coated Anodised aluminums frame for doors, windows, ventilators with one or more rebates including joining cleat and handles and other necessary fittings for fixing etc, complete all as specified and as directed. |
| 46 | S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified and as directed. |
| 47 | S & F Powder coated Anodized Aluminium window and ventilators shutters, without sash bar, aluminum section weighting 0.55kg / m including necessary joining cleats, glazing clips, rubber packing, anodized aluminum snap beading, screws, locking arragement,Handles etc, complete all as specified and as directed. |
| 48 | Hacking out broken glass any thickness, size, quality, from wooden frame/steel frames fixed with putty or with wooden beads, complete all as specified and as directed. |
| 49 | S&F Sheet glass 4 mm thick ordinary quality one way glazing with rubber gasket in square not exc 0.5 sqm each pane, complete all as specified and as directed. |
| 50 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with wooden beading or with nuts and bolts to existing steel windows/wooden windows, complete all as specified and as directed. |
| 51 | M&L preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10cm width or girth applying two coats synthetic enamel paint over one coat of prink primer, complete all as specified and as directed. |
| 52 | M&L preparation of old painted surface of wood and wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamal paint, complete all as specified and as directed. |
| 53 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome, complete all as specified and as directed. |
| 54 | M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 55 | S&F 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs etc,including tank nipples, fittings, including dismantling of existing water tank any type,disposal of rubbish, complete all as specified and as directed. |
| 56 | S & F in repairs 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed. |
| 57 | S&F in repair Stop/angle valves 15 mm, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle fancy type chromium plated, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 58 | S&F in repairs for 15 mm bore bib taps, fancy type chormium plated with crutch or butterfly handle screwed down screwed for iron pope or for brass ferrule, complete all as specified and as directed. |
| 59 | S&F in repair vitreous china wash basin, white flat back size 550x400 mm plug, porcelain stopper and incl brackets with waste fittings, brass, chromium plated for glazed ware basin etc with long screwed shanks and fly-nuts, flange end bedded in read lead cement and other end fixed and connection pipe etc including pedestal , complete all as specified and as directed. |
| 60 | S&F in repairs Vitreous China Urinal, Full stall type, white including flushing cistern, flush pipe and waste pipe , complete all as specified and as directed. |
| 61 | S&F in repairs vitreous china wash down water closet pan ( Pedestal pattern) white or coloured excluding flushing cistern and flush pipe and seat cober incl provision of concrete/ white cementing and P or S trap, complete all as specified and as directed. |
| 62 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup, complete all as specified and as directed. |
| 63 | S&F PVC connection pipe 15 mm size with PTMT nuts of length 600mm fixed to GI tubbing, complete all as specified and as directed. |
| 64 | S&F in repair brass chromium plated tubular towel rail 20 mm dia D type , 60 mm long between flages, complete all as specified and as directed. |
| 65 | S & F in repairs Brass CP wall mixer /WHB Mixer 15 mm for mixing hot & cold water screwed down for iron pipeand fixed, complete all as specified and as directed. |
| 66 | Taking up or down 15mm bore steel water tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 67 | Taking up or down 20mm bore steel water tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 68 | S&F 15mm bore steel water tube, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 69 | S&F 20mm bore steel water tube, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 70 | S&F in repairs corner sheet glass shelf assembly consisting of 5.5 mm sheet glass shelf 12 cm wide with brass chromium plated bracket guard , complete all as specified and as directed. |
| 71 | S&F in repairs CP health faucet (ABC) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook incl making connection and fixed in position, complete all as specified and as directed. |
| 72 | S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floor or to wall, complete all as specified and as directed. |
| 73 | S&F PVC (SWR) junction single T equal or unequal 110 mm bore, complete all as specified and as directed. |
| 74 | S&F PVC (SWR) bends 110 mm dia fixed, complete all as specified and as directed. |
| 75 | S&F PVC (SWR) vent cowl 110 mm bore fixed , complete all as specified and as directed. |
| 76 | S&F PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floor , complete all as specified and as directed. |
| 77 | S&F PVC (SWR) junction single T equal or unequal 75 mm dia, complete all as specified and as directed. |
| 78 | S&F PVC (SWR) bends 75 mm dia fixed, complete all as specified and as directed. |
| 79 | S&F PVC (SWR) vent cowl 75 mm bore fixed, complete all as specified and as directed. |
| 80 | S&F stainless steel curtain rods of selective quality designed and colour shall be as directed by Engr-in-Charge, complete all as specified and as directed. |
| 81 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. |
| 82 | M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqmm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor. |
| 83 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 84 | (b) One 3 pin 5 Amp switch socket outlet on independent board |
| 85 | (c) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 86 | M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 2.5 Sqmm as earth continuity conductor. |
| 87 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed |
| 88 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed |
| 89 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete with gang box, complete all as specified and as directed. |
| 90 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete with gang box, complete all as specified and as directed. |
| 91 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 92 | S&F in repairs Distribution Board, SPN 12 Way, Double door, complete all as specified and as directed. |
| 93 | S & F in repairs MCB,DP 40 Amps 240 Volts B curve, complete all as specified and as directed |
| 94 | Supply & Fixing in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 Amp to 32 Amp, in the MCB DB Complete with connection testing and commissioning,complete all as specified and as directed. |
| 95 | Supply & Fixing in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 32 Amp, in the MCB DB Complete with connection testing and commissioning,complete all as specified and as directed. |
| 96 | Supply & Fixing in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of two poles and current carrying capacity 63 Amp SPN in the MCB DB complete with connection testing and commissioning,complete all as specified and as directed. |
| 97 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity TPN 100 Amp in the DB complete with connection testing and commissioning,complete all as specified and as directed. |
| 98 | Supply & Fixing in repair TPN DB 4 way sheet metal enclosure TPN 450 volts, 50 Hz, with IP-42 protection,Double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting,complete all as specified and as directed. |
| 99 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 100 | Supply and fixing LED bulb 12 W, 220V suitable size, complete all as specified and as directed. |
| 101 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 102 | S& F LED light fitting 1x10 bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 103 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and as directed. |
| 104 | S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. |
| 105 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated Supply Supply and fix complete with all accessories such as safety valve, thermostate, NRV, connection piece etc,2 x Hot & Cold (24\\") PVC connection, complete all as specified and as directed. |
| 106 | S & F in repair Sub main wiring using two runs of single core PVC insulated cable with copper conductor multistranded 1100 volts of sizes 6.0 Sqmm through existing/ new non metalic PVC conduit including copper earth wire in green colour of size 6.0 Sqmm connection to DB with thimbling complete as specified and directed. (Note:- Two runs of sub main wire including earth wire and rigid non metalic PVC casing capping shall be measured as one unit per RM make of cable)Contractor must make wall/ceiling cheasel and after fixing make surface good as it is. |
| 107 | S&F XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, 25 Sqmm 3 core, complete all as specified and as directed. |
| 108 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 16 Sq mm 4 Core, complete all as specified and as directed. |
| 109 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 16 Sq mm 2 Core, complete all as specified and as directed. |
| 110 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 50 Sq mm 3.5 Core, complete all as specified and as directed. |
| 111 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, laying of cables, etc. and getting out in soft / loose soil, complete all as specified and as directed. |
| 112 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm depth in soil, complete all as specified and as directed. |
| 113 | Removing excavated material (soil ) n.exc 50m and depositing where directed at a level n.exc. where directed at a level n.exc, complete all as specified and as directed. |
| 114 | Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection, complete all as specified and as directed.(Note: The punned down thickness shall only be measured) |
| 115 | Supply and laying sub class 'B' bricks laid across the cable for cable protection, complete all as specified and as directed. |
| 116 | Supply and fixing LED street light fitting 70 watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with drive, lamp bracket with impact and corrosion resistant including thermal managememt in multiple optic complete with with IP 65/66 protection, complete all as specified and as directed. |
| 117 | Supply and fixing LED Flood light 100 watt 230V AC outdoor type with thermal managememt in multiple optic and eqipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed. |
| 118 | Supply and fixing 240V, 10 KA 'B' curve (MCBs) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB, complete all as specified and as directed. |
| 119 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of capacity SPN 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 120 | Supply and fix PVC insulated unsheathed copper cable of size 1.5 Sqmm 3 core FR PVC for service connections from junction box to light fitting, complete all as specified and as directed. |
| 121 | Supply and fix loopin loopout fuse junction box of size 205 x255x112 mm made out of thermo plastic Polycarbonate with IP 66/67 weather proof for outdoor installation (with knockouts of cable entry) protection with terminals and locking screw fitted with 5 Amps fuse cutout-01 No with 6A MCB, suitable for cable size 10 sqmm and fixing on steel tubular pole at a height not less than 1.5m above ground level with the help of clamps two nos of F1 20 x 3 mm and suitable nuts and bolts, complete all as specified and as directed. |
| 122 | Supply and laying GI pipe 40mm dia light grade for cable protection on pole/road/culvert crossing and for on pedestal, complete all as specified and as directed. |
| 123 | Supply and fixing GI pipe, bracket for street light fittings made out of 40 mm dia GI Pipe medium grade 1.20 m long bent to required angle/shape with and including necessary clamps, nuts, bolts & washers of suitable size and two coats of aluminium paint with a base coat of red oxide primer, complete all as specified and as directed. |
| 124 | M&L in for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 125 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 630 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :- |
| 126 | (a) INCOMING |
| 127 | (i) MCCB 4 Pole 415 volts grade 400 Amps rating and 36 KA rupturing capacity - 01 No |
| 128 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 129 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-800 Amps with three way rotary selector switch -01 No |
| 130 | (iv) CTs ratio 400/5A class ISI marked sets of three each |
| 131 | (v) Indicating lamp-01 set of three |
| 132 | (b) OUTGOING |
| 133 | (i) MCCB Four Pole, 415 volts grade adustable type 200 Amps rating and 36 KA rupturing capacity -02 Nos |
| 134 | (ii) MCCB Four Pole, 415 volts grade Adjustable 125 Amps rating and 36 KA rupturing capacity -02 Nos |
| 135 | Supply and installation of HT 11 KV, 3 phase, 50 Hz Rupturing capacity 350 MVA Indoor type VCB Panel,Totally Metal clad withdrawable type VCB Including cable Connection with Copper bus bar of 800 Amps Rating .The Switchgear panel of CRCA Sheet steel Duly powder coated with sheet 2 MM thickness.Manually and Motor operated spring charged type electrical-24 V operation type VCB incorporation Mechanical as well as electrical ON/OFF indicattion OFF Push button,Test / Service Position Limit switches with Minimum 6 NO +6NC breaker auxillary contacts C5 service position.Epoxy cast wound current transformer (CT), 11 KV ,100/50/5-5 core 1:class 1, 15 KVA for 3 Phase core 2:5P10 ,15 KVA burden with metering and protection c ore including necessary wiring including all necessary eart /Over-current Fault relaysand suitavle meters, complete all as specified and as directed. |
| 136 | Note:- Schedule of credit Rs 65,887.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |