| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Superintending Engineer, Kanupur Rehabilitation Camps & Building Division, Basudevpur,Dist-Keonjhar Name of Work:- “Construction of Kothi Ghara (Thakurani) at Dhobalabeda (Daduan) R&R colony for the DPs of village Daduan of K.I.P.” Contract No: SE, KRC & BD-01/2026-2027 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER# NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate inRs. P. Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT Rs. P. TOTAL AMOUNT In Words |
| 2 | Earth work in hard soil or gravelly soil for foundation within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 3 | Filling foundation and plinth with excavated material with well compacted etc. complete as per the direction of the Engineer-in-charge. |
| 4 | Filling foundation & plinth with coarse sand watering ramming with cost,coveyance ,royalty and Labour charges etc complete and as per the Direction of the Engineer-in-charge. |
| 5 | Cement concrete (1:3:6)with 40mm size hard granite metal with watering and curing including cost,conveyance ,royalty of all materials ,labour ,T& P etc complete and as per the direction of the Engineer-in-Charge. |
| 6 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite(crusherbroken) stone chips including hoisting and laying etc complete and as per the Direction of the Engineer-in-charge. |
| 7 | Rigid and smooth centering and shuttering for C.C. / R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor & as per the Direction of the Engineer-in-charge. a) Foundation footing and column base & plinth beam |
| 8 | Rigid and smooth centering and shuttering for C.C. / R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor & as per the Direction of the Engineer-in-charge.b) Column & beam (i) Ground floor |
| 9 | Rigid and smooth centering and shuttering for C.C. / R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor & as per the Direction of the Engineer-in-charge.c) Lintel (i) Ground floor |
| 10 | Rigid and smooth centering and shuttering for C.C. / R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor & as per the Direction of the Engineer-in-charge.d) Chhaja , Roof slab, Window sill & Shelves. (i) Ground Floor |
| 11 | Providing F.A. Brick masonry in CM(1:6) using well burnt F.A. Brick of approved quality having crushing strength not less than 75 Kg/cm2 with cost ,Conveyance ,royalty of all materials with labour etc Coplete and as per the direction of Engineer -in-charge.For F & P |
| 12 | Providing F.A. Brick masonry in CM(1:6) using well burnt F.A. Brick of approved quality having crushing strength not less than 75 Kg/cm2 with cost ,Conveyance ,royalty of all materials with labour etc Coplete and as per the direction of Engineer -in-charge.For Super Structure |
| 13 | 12 mm thick cement plaster (1:6) finished smooth to outside surface of brick walls after racking out the joints including watering and curing ,scaffolding if required with cost ,Conveyance ,royalty of all materials with labour etc Coplete and as per the direction of Engineer -in-charge. |
| 14 | 16mm thick cement plaster (1:6) to inside using good quality of sharp clean washed sand of approved quality in all floors finished smooth to inside rough surface of brick wall with scafolding after racking out the joints including watering, curing, cost, conveyance, royalty of all materials and cost of all labour, T & P etc. required for the work complete and as directed by the Engineer-in-Charge. |
| 15 | 6 mm thick CP (1:4) to RCC / CC sufaces finished smooth including closed deep chiping and slury treatment etc. complete as directed by the Engineer-in-Charge. |
| 16 | Providing 2.5 cm thick grading concrete (1:2:2) on roof slab with 6 mm size crusher broken granite chips (free from weathered skin and debris etc.) on new works including watering and curing including cost, conveyance, royalty etc. of all the materials and labour etc. complete as per the direction of the Engineer-in-Charge.. |
| 17 | Distempering two coats to walls with distemper of approved shade on new work ( two coats) including cost of all materials, labour, T & P etc complete as per direction of Engineer in charge. |
| 18 | Priming one coat with any approved primer both inside and out side wall including cost of primer, labour, T & P etc complete as per direction of the Engineer-in-charge. |
| 19 | Outside wall painting two coats with weather coats of approved shade on new work to give an even shade including cost of paint, labour , T & P etc complete as per direction of Engineer-in-charge. |
| 20 | Supplying, Cutting , straightening, coiled or bent up M.S Rod or Tor steel bending, binding welding and joinging if necessary and tying the grills and placing in position as required for RCC work and providing fan hooks hoisting lowering and including cost, conveyanceof M.S rods or tor steel and binding wire of 18 to 20 gause required for the work for bending, binding and tying the grills (payment will be made on weight of M.S Rod or Tor steel only and no separate payment will be made towards the weight of binding wire) etc. complete as directed by the Engineer-in-charge . |
| 21 | Providing, fitting and fixing of MS grills, doors, windows, shutters & staircase hand rails of different size as per the approved design including cost of all materials, labour and conveyance etc. complete as per the direction of the Engineer-in-charge. |
| 22 | Painting two coats with enamel paint over a coat of red oxide primer to give an even shade including cost of primer, paint & labour , T & P etc required for the work complete as per the direction of the Engineer-in- charge. |
| 23 | 2.5 cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size crush broken granites chips complete as per the direction of the Engineer-in-Charge. |
| 24 | 12mm thick cement plaster (1:4) over brick work including cement punning for skirting including all cost carriage and royalty etc. complete as per the direction of the Engineer-in-charge. |
| 25 | CC (1:2:4) with 12mm size black hard CB granite chips with watering and curing excluding shuttering but including cost,conveyance ,royalty of all materials ,labour ,T& P complete as per the direction of the Engineer-in-charge. |
| 26 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex / L&T / Anchor / Havels / V Guard ) |
| 27 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex / L&T / Anchor / Havels / V Guard ) |
| 28 | Recessed wiring to light point/fan point/ exhaust fan point/ callbell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Havels / V Guard )(Short point) |
| 29 | Recessed wiring to light point/fan point/ exhaust fan point/ callbell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Havels / V Guard )(Medium point) |
| 30 | Recessed wiring to light point/fan point/ exhaust fan point/ callbell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Havels / V Guard )(Long point) |
| 31 | Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required. |
| 32 | Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 100 mm deep (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. |
| 33 | Supplying and fixing of 16 / 18 SWG metal box of 150 mm x 150 mm x 60 mm deep (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. |
| 34 | Supply and fixing of 5pin 15 / 16 amp socket outlet on the existing switch box/cover including connection etc required. |
| 35 | Supply and fixing of 15 / 16 amp piano type switch on the existing switch box/cover including connection etc required. |
| 36 | Supply and fixing of 3pin 5 / 6 amp socket outlet on the existing switch box/cover including connection etc required. |
| 37 | Supply and fixing of 5 / 6 amp piano type switch on the existing switch box/cover including connection etc required. |
| 38 | Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required |
| 39 | Supplying , fitting ,fixing, testing and commissioning of 9watt LED bulb. |
| 40 | Supplying , fitting ,fixing, testing and commissioning of 50watt LED street light |
| 41 | Supply of A.C Ceiling fan of size 48\\" without regulator. |
| 42 | Installation, Testing and Commissioning of ceiling fan including wiring the down rod of standard length (up to 30cm) with 1.5 sq.mm FR PVC insultated single core multistrand copper conductor etc, as required. |
| 43 | Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required. |
| 44 | Supply and fixing, installation, testing and Commissioning of 32 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge.Make-SEIMENS/HPL/ANCHOR/L&T/HAVELS/C & S/ RK |
| 45 | Supply and fixing of 5 amp to 32 amp rating 240 V \\"B\\" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required. |
| 46 | S/F of G.I Bend pipe for street light Total in Figures 1127457.43 1127457.43 INR Eleven Lakh Twenty Seven Thousand Four Hundred & Fifty Seven and Paise Forty Three Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |