| Sl. No. | Item Description |
| 1 | Section I Building Work |
| 2 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 3 | Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B) |
| 4 | Filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. |
| 5 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 6 | Providing designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 9 | Supplying, fitting & fixing 30mm thick solid core type decorative Single leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 10 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, includingM.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steelprimer after pre-treatment of the surface as directed by Engineerin-charge Fixing with adjustable lugs with split end tail to each jamb |
| 11 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 12 | (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 13 | Frame size 45 x 70 mm |
| 14 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. |
| 15 | (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 16 | 30 mm thick for D1 |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 18 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium(minimum thickness of polyester powdercoating 50 micron) |
| 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight notless than 10kg/sqm) |
| 20 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete.With 12 mm mild steel U beading |
| 21 | Extra for Brick work for each consecutive floor above first floor including watering and scaffolding all complete as per direction of E/I |
| 22 | For 10\\" th. B/W. |
| 23 | A. Second Floor |
| 24 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 25 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone -III ) : 3 graded stone aggregate 20mm nominal Size) |
| 26 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, , bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 27 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 28 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, Slab plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 29 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, Slab,Beam plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 30 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, Slab,Beam ,Column plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 31 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 32 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 33 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form forCentering and shuttering including strutting, propping etc. and removal of form for |
| 35 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 37 | Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form forStairs, (excluding landings) except spiral-staircases |
| 39 | Centering and shuttering including strutting, propping etc. and removal of form forShelves (Cast in situ) |
| 40 | Providing reinforcement (Round bars confirming to I.S. 432 dia In mm (I.S. 2062 Gr A) of 6 &8 mm. dia rods as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing the rods on position all complete as per building specification and direction of E/I.(ii) 8 mm dia Gr. A (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 41 | Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 42 | Providing Tor Steel reinforcement of 10mm , 12 mm & 16 mm dia bars as per approved design and drawing excluding carriage of bars to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I |
| 43 | (a) 10 mm (TMT coil Fe 500) (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 44 | (b) 12 mm (TMT coil Fe 500) (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 45 | (c) 16 mm (TMT coil Fe 500) (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 46 | Providing Tor Steel reinforcement of 20mm, 25 mm, 28mm, 32mm dia bars as per approved design and drawing excluding carriage of M.S. bars of work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I |
| 47 | (a) 20 mm ,25mm, 28mm & 32 mm TMT bar FE 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 48 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 49 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 51 | Over Internal & External Surface |
| 52 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone -III ) : 3 graded stone aggregate 20 mm nominal Size) |
| 53 | Providing & supplying Cico liquid / impermo water proofing compound in cement concrete or cement mortar @ 2% of cement quqntity by weight ( as specified) for water proofing, including all carraige and taxes . |
| 54 | Providing & laying water proofing treatment in sunken portion of WCs, abathrooms etc. by applying cement slurru mixed with Armourcrete of M/S The Structural Water Proofing Company PVT. Ltd.or Tapecrete of M/s CICO Engg. Servce consisting of applying : |
| 55 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.125 kg/ sq.m. This layer will be allowed to air cure for 4 hours |
| 56 | (b)second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/ sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 57 | The rate includes preperation of surface, treatment& sealing of all joints, corners, junctions of pipes & masonary with polymer mixed slurry. |
| 58 | Providing 250 mm wide brick drain in cement mortar (1: 6) with av. 150 mm. clean depth and 250 mm apron including cost of earthwork involved with 75 mm, cement concrete (1: 4: 3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain duly plastered in C.M (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 59 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 60 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 61 | Shoe 110 mm |
| 62 | Coupler 110 mm |
| 63 | Bend 110 mm |
| 64 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 65 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 50 x 20 mm |
| 66 | Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 67 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 68 | Light shade pigment using white cement |
| 69 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 on inside wall including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 70 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 71 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 72 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : |
| 73 | Udaipur green marble(stair,kit counter,partition) |
| 74 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 75 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 76 | Extra for providing edge moulding to 18mm thick marble stone counters,Vanities etc. over Item No. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite work |
| 77 | Extra for plaster work over exteriour surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I |
| 78 | A. Second Floor |
| 79 | B. Third Floor |
| 80 | Making 6x6 mm Groove in plaster surface over walls trully horizantal and vertical as specified as regular interval , at all heights including claening finishing scaffoolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I. |
| 81 | Extra for FLOORING work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I. |
| 82 | A. Second Floor |
| 83 | B. Third Floor |
| 84 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 85 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm) |
| 86 | Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I. |
| 87 | Providing two coats of synthetic enamel paint of approved shad and make over new wooden surface including cleaning the surface after removing dirt sccales smokes grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 88 | Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 89 | P/L 60 mm thick factory made cement concrete interlocking paver block of M30 grade |
| 90 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 91 | Bricks |
| 92 | Coarse Sand |
| 93 | Stone Chips |
| 94 | Cement |
| 95 | Steel |
| 96 | Earth |
| 97 | Section - II Water supply and sanitary installation works |
| 98 | Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50 grms, 15mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificatin and direction of E/I. (A) 580 mm long (C) with 10 ltrs. low level P.V.C. Cistern |
| 99 | Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C with Ptrap of parry/Hindustan or any other approved I.S.S make ineluding supplying and fixing 15 liters C.I mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket wit h telescopic flush pipe with brass eoupling and plumbers joints spindle stop coci of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white /black plastic solid state seal and lead of commander / cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. (I) With 'P' trap(b) 10 Lit Law Lavel PVC Cistern. |
| 100 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 101 | Providing and fixing C.P.brass long nose bib cock of approved quality conforming to standard and weight not less thain 810gms. 15mm nominal bore approved brand C.P. fittings |
| 102 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 15 mm nominal bore |
| 103 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 104 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (a) 15mm nominal bore |
| 105 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 15 mm nominal bore, weighing not less than 32 gms |
| 106 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end ) |
| 107 | 25MM nominal bore |
| 108 | 32MM nominal bore. |
| 109 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape : Rectangular shape -453 X357 mm |
| 110 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Falt back wash basin size550x400mm with single 15mm pillar tap |
| 111 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole |
| 112 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length |
| 113 | Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia |
| 114 | Providing and fixing on wall face unplasticised Rigid pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 115 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 116 | PVC Door Tee 110mm dia SINGLE JUNCTION ( Supreme ) |
| 117 | PVC Plain Bend 110mm dia ( Supreme ) |
| 118 | PVC Door Bend 110mm dia ( Supreme ) |
| 119 | 110mm dia PVC cowel ( Supreme ) |
| 120 | 110x110x110 mm each |
| 121 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 122 | 15 mm nominal outer dia Pipes |
| 123 | 20 mm nominal outer dia Pipes |
| 124 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 125 | 25 mm nominal outer dia Pipes |
| 126 | 32 mm nominal outer dia Pipes |
| 127 | 40 mm nominal outer dia Pipes |
| 128 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 129 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stoneaggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 130 | Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe |
| 131 | Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required: 600x450x200mm |
| 132 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 133 | Supplying Fitting Fixing Health faucet with 1 Meter long Easy Flex Tube in Chrome Finish & wall Hook all accessories (Make jaguar model no. ALD-CHR-585 or Equivalent like Mark, Grohe. ) |
| 134 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 135 | Providing and fixing PTMT/ C.P. swivelling shower,15mm nominal size, 95mm long, 65mm dia. of approved quality, color & make weighing not less than 40 gms with approximate 80 holes of 1.2 mm dia. |
| 136 | Section III 200x150xmm dia Deep bore Well With Pump set & electrification etc works. |
| 137 | Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site. |
| 138 | From 0.0M to 50.0 M belew G.L |
| 139 | From 51.0 M to150.00 M belew G.L |
| 140 | Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job. |
| 141 | Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. |
| 142 | Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages2.0 HP |
| 143 | Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914.F.A.S.D. Starter 10 HP |
| 144 | FR PVC insulated 3 core 4 sq.mm. copper wire. |
| 145 | Supplying & lowering 40mm da column G. I. pipe with all complete job. |
| 146 | Section - IV Septic tank & Soak pit ( 2 nos) |
| 147 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. |
| 148 | Extra for earthwork in hard soil as per specification and direction of E/I. (Vide classification of soil item) |
| 149 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 150 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 151 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20mm nominal Size) |
| 152 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 153 | Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 154 | Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 155 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 156 | Providing designation 75A brick work in C.M (1 : 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth, curring, taxes and royalty all complete as per builiding specification and direction of E/I. |
| 157 | Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 158 | Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I. |
| 159 | Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 160 | Supplying and fixing C.I. cover without frame for manholes |
| 161 | 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg |
| 162 | Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel ). |
| 163 | 8 mm dia |
| 164 | 10 mm dia |
| 165 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 166 | Bricks |
| 167 | Coarse sand |
| 168 | Stone Chips |
| 169 | Cement |
| 170 | Steel |
| 171 | Section VI - APPROACH ROAD 30 Mtr leangth |
| 172 | Excavation in Soil by Manual means. (Excavation for foadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.)(ii) Including Royalty @ Rs. 27.48 per cum the cost of watering, rolling & compaction |
| 173 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe |
| 174 | Providing designation 75 A one brick edge soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 175 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone -III ) : 3 graded stone aggregate 20 mm nominal Size) |
| 176 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 177 | Bricks |
| 178 | Coarse sand |
| 179 | Stone Chips |
| 180 | Cement |
| 181 | LAND DEVELOPMENT |
| 182 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 183 | Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B) |
| 184 | Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed with earth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume) |
| 185 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 186 | Providing designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 187 | Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 188 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 189 | Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 190 | Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I. |
| 191 | Filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. |
| 192 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 193 | Bricks |
| 194 | Coarse sand |
| 195 | Stone Chips |
| 196 | Cement |
| 197 | Rain Water Harvesting |
| 198 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 199 | Extra for earthwork in hard soil (vide classification of soil item B) as per specification and direction of E/I. |
| 200 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 201 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 202 | Providing designation 75 B BRICK FLAT SOLING joint filled with local sand including cost of watering taxes and royality all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 203 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20mm nominal Size) |
| 204 | Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete |
| 205 | Providing designation 75A brick work in C.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 206 | Providing tuck pointing (1:3) in cement on brick work clean corse sand of FM 1.5 including screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 207 | Providing 12 mm cement plaster (1:3) with clean corse sand of FM 1.5 with floting coat of neat cement in skirting including rounding of junction with door curing taxes and royaltty all complete as per builiding specification and direction of E/I. |
| 208 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100 mm nominal size dia |
| 209 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 210 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. |
| 211 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 212 | Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 213 | Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. |
| 214 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line : |
| 215 | Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe |
| 216 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 217 | Bricks |
| 218 | Coarse sand |
| 219 | Stone Chips |
| 220 | Cement |
| 221 | Steel |
| 222 | 125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making 125/115 mm dia boring etc and cost of transporting rig machine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate) |
| 223 | Drilling upto 30 M depth below G.L in Rular area |
| 224 | Drilling beyond 31 mtr upto 55 mtr below GL in Rural area |
| 225 | 32 mm UPVC pipe 125 mm dia conforming to I.S.I latest revision in 12818/2016 CML No. 5543459 |
| 226 | S/M/L for F/f wire mesh pipe |
| 227 | Electical Installation Work |
| 228 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Paraflex/Nitcab (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)/Legrand(allzy)/Schneider/L&T(enZem) (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/L&T/Legrand/Schneider (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard/Paraflex (7) LED ITTING FIXTURE -: Havells/Crompton /Philips(Model/as per E/I ) (8) CEALING / WALL / EXHAUST FAN -: Havells / Usha / Crompton (Model/as per E/I ) (9)OCTAGONAL POLE-: Bajaj/Philips/Surya (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ TOSHIBA/DAIKIN (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED |
| 229 | Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 230 | Group A |
| 231 | Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required. |
| 232 | Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 233 | Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 234 | 2x1.5 sq mm+1x1.5 sq mm earth wire |
| 235 | 4X2.5 sq mm+2x2.5 sq mm earth wire (for LED building outar light) |
| 236 | 2x2.5 sq mm+1x2.5 sq mm earth wire |
| 237 | 2x6 sq mm+1x6 sq mm earth wire |
| 238 | 2x10 sq mm+1x6 sq mm earth wire |
| 239 | TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required. |
| 240 | S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 241 | S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required . |
| 242 | 75mm x 75mm x 50mm deep/ (4\\" x 4\\") |
| 243 | S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 244 | 5/6 amps, one way switch |
| 245 | 5/6 amps, socket |
| 246 | TV socket socket outlet |
| 247 | S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 248 | S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 249 | 1 or 2 module(78mm x 78mm x 45mm) |
| 250 | 6 module(78mm x 205mm x 50mm) |
| 251 | S/F light plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch conection painting etc, as required. |
| 252 | S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required. |
| 253 | S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 254 | S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required. |
| 255 | S/F Dingdong Call bell :-Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required. |
| 256 | Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 257 | ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 258 | S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 259 | 8 Way,Double door |
| 260 | S/F 'B' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 261 | 6/32 amps,single pole, \\"B\\" SERIES |
| 262 | S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 263 | 6/32 amps,single pole, \\"C\\" SERIES |
| 264 | 40 amps ,DP |
| 265 | 50/63 amps, DP |
| 266 | Supply of Modular type AC starter switch for single phase 230 V /50 Hz of capacity 20/25 amp |
| 267 | P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required. |
| 268 | S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 269 | P/F G.I. lightning conductor finial:-Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 270 | Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required. |
| 271 | P/F G.I. lightning conductor tape in horizontal run:-Providing and fixing copper tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run) |
| 272 | P/F G.I lightning conductor tape in vertical run:-Providing and fixing copper tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run) |
| 273 | P/F Testing joint for G.I. lighting conductor:-Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos.of G.I. bolts, nuts, chek nuts and spring washers etc complete as required. |
| 274 | Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 275 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 276 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 277 | 3½ X 70 sq. mm (38mm) |
| 278 | 3½ X 95 sq. mm (45mm) |
| 279 | S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1) |
| 280 | 70 sq.mm. 3.5 core |
| 281 | 95 sq.mm. 3.5 core |
| 282 | Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton |
| 283 | S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 284 | 1200 mm (48\\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 285 | SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 286 | 15/16 W LED Round Down Light of make bajaj/havells/crompton/C&S |
| 287 | SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 288 | 90 /100 W LED Street light of make bajaj/havells/ crompton/C&S |
| 289 | SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 290 | 20/22 W LED Batten of make bajaj/havells/crompton/ C&S |
| 291 | Supplying and fixing of LED 15/16 W of make bajaj/havells/crompton or equivelent |
| 292 | Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke) |
| 293 | Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel. |
| 294 | LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following: |
| 295 | (A) INCOMING |
| 296 | 25/100 A 16 KA MCCB FP Fixed thermal seting |
| 297 | 150/160 A 35 KA MCCB FP Adjustable thermal seting |
| 298 | 200A TPN BUSBAR(COPPER) |
| 299 | (B) OUTGOING |
| 300 | 6/32 amps,SPN |
| 301 | 40 amps,DP |
| 302 | 50/63 amps, DP |
| 303 | Auto change over switch 2.5 Amp |
| 304 | (C) OTHER ACCESSOSRIES |
| 305 | DIGITAL VOLT METER 500V(3phase class 0.5) |
| 306 | DIGITAL A METER 500V(3phase class 0.5) |
| 307 | COPPER WIRE 1.5MM |
| 308 | COPPER WIRE 6 MM |
| 309 | COPPER WIRE 10MM |
| 310 | COPPER WIRE 25MM |
| 311 | LED INDICATOR LAMP R/Y/B/G |
| 312 | C.T COIL OF CT ratio 500/5 IS2705 part -3 |
| 313 | S/F wall floor mounted cubical panel board , fabricated with 16 gauge iron sheet suitable for panel mounted switch disconnector, Space for 13 Nos. of Single Phase Energy meter,Space for busbar,insulator and painting etc.as required .(but without busbar copper strip /Switchgears/MCB's/Wiring and other accessosries) The rate of this itom is sum of A+B+C =Rs.122084.60@ 50% That is Rs. 61042.30 |
| 314 | Add 18% GST |
| 315 | Add 1% Lebour Cess Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |