| 1 | Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. complete including removal of debris to a distance exc 1.5 Km but n exc 2 Km, Complete all as specified. |
| 2 | M&L for 15mm thick rendering on fair faces of brick work or stone masonry surface in CM 1:4 finished the surface even and smooth (without using extra cement on external wall surface, complete all as specified. |
| 3 | Supply only integral water proofing compound all as directed. |
| 4 | Preparing of new plastered surface of wall and applying two coat cement base paint over a coat of primer on newly plastered surfaces, complete all as specified. |
| 5 | Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/down facia/soffits and fins of RCC chajjas/beams/columns/balconies etc. and also applying one coat of anti corrision paint to visible reinforcement if any. Supply and fixing by means of nailing wire netting of galvanised wire 1.40mm dia and mesh size 20mm and brushing neat cement slury with 3.00 Kg of cement/sqm and M&L for 20mm thick cement rendering in two layers of 10mm each using shot gun or pressure nozzle for grouting the surface well bonded wih reinforcement (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs etc complete all as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.5 km but n.exc 2 Km, all as specified and as directed. |
| 7 | M&:L for Plain cement concrete M-10, nominal mix, type C-2, using 20mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture, all as specified and directed by Engg-In-charge. |
| 8 | Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 9 | S&F Mild steel framed work such as grills, gratings, etc..with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engg-In-charge. |
| 10 | All as per srl item No 9 above but for portions framed and hung as gates, including pintle hinges, stops hand made sliding bolts etc. all as specified and directed. |
| 11 | Steel wire fabric welded steel wire fabric supplied and fixed complete to wood or steel members of weight n exc 4 kg per sqm all as specified and directed. |
| 12 | Preparation of new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 13 | Taking down water tank of capacity exc 500 litrs & n exc 1000 ltrs capacity, cleaning & removing to store, complete all as specified. |
| 14 | S&F for Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with Brass PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, all as specified. |
| 15 | All as per item no 14 above but expect water tank |
| 16 | S&F 15 mm Tank Nipple PTMT suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms) complete all as specified and as directed |
| 17 | S&F 20 mm Tank Nipple PTMT suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms) complete all as specified and as directed |
| 18 | S&F 32 mm Tank Nipple PTMT suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms) complete all as specified and as directed |
| 19 | Disconnecting existing tanks, setting aside (or lowering, if required) for repair, cleaning and removing all scale and dirt, etc., from water tanks of capacity exc 500 but n exc 1000 ltr, from mouths of circulating pipes, hoisting, reconnecting and re-fixing in position, complete all as specified and directed. |
| 20 | S&F in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15 mm - 142 gms/ 20 mm - 210 gms / 25 mm - 455 gms / 40 mm - 690 gms), complete all as specified. |
| 21 | S&F in repair 25 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15 mm - 142 gms/ 20 mm - 210 gms / 25 mm - 455 gms / 40 mm - 690 gms), complete all as specified. |
| 22 | Taking up or down old 15 mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing, removal to store,complete all as specifed . |
| 23 | Taking up or down old 20mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing or removal to store,complete all as specifed . |
| 24 | Taking up or down old 25mm/32mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing or removal to store,complete all as specifed . |
| 25 | S&F for steel tubes 15 mm bore, galvanised, \\" medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specifed |
| 26 | All as per item No. 25, above but except GI tubing, complete all as specified. |
| 27 | S&F for steel tubes 20 mm bore, galvanised, \\" medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specifed |
| 28 | All as per item No. 27, above but except GI tubing, complete all as specified. |
| 29 | S&F for steel tubes 32 mm bore, galvanised, \\" medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specifed |
| 30 | All as per item No. 29, above but except GI tubing, complete all as specified. |
| 31 | Taking out existing treatment on roof slab, taking down cement plaster including existing tarfelt from old roof surfaces by brushing with wire brushes for removing caked etc sweeping with brooms and finally fanning the cleaned surface to remove all loose dirt etc on roof including and applying the following :-(i) M&L for 15mm thick rendering in CM 1:4 mixed with WPC @ 3% by weight of cement or as per manufacturers instructions, the surface shall be finished even & smooth without using extra cement.(ii) FIRST COURSE : One coat of bitumen primer confirming to IS -3384 @ 0.40 Kg/Sqm.(iii) SECOND COURSE : One coat of bonding material using blown type bitumen confirming to IS - 702 grade 85/25 @ 1.20 Kg/qm. (iv) THIRD COURSE : A layer of APP modified polymeric membrane, Centre core of 100 mm micron HMHDPE, outer film 20 micron each, thickness 3 mm, having wieght not less than 2.25 Kg/Sqm, complete all as specified. |
| 32 | Preparation of newly APP membrane surface and applying one coat of aluminium paint over APP membrance, complete all as specified. |
| 33 | Taking up or down tank staging/monkey caging, refixing it same position after completion of roof treatment, if broken, the same shall be made good by welding process complete all as specified and directed by Engineer in charge |
| 34 | Mild steel Joist channel, angle or tee section fixed independantly without connection plate etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to grade Fe.410-0.Gde-E-250 quality A, complete all as specified and directed. |
| 35 | Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 36 | Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. Please Enable Macros to View BoQ information |