| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 2 | All kind of soil |
| 3 | Ordinary Rock |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches of drains (not exceeding 1.5m in width or 10sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed with in lead of 50mtr |
| 5 | All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Providing and laying, mechanically mixed and vibrated cement concrete 1:4:8 (one cement:four sand eight graded crushed stone aggregate 40 mm (forty millimeter) nominal size) including curing as required at site complete excluding the cost of form work but including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 8 | Providing and laying, mechanically mixed and vibrated cement concrete 1:5:10 (one cement:Five sand Ten graded crushed stone aggregate 40 mm (forty millimeter) nominal size) including curing as required at site complete excluding the cost of form work but including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 gradedstone aggregate 20 mm nominal size) |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 12 | All work up to plinth |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering |
| 15 | Providing from work with steel plates 3.15 mm (three decimal fifteen millimeter ) thick welded with angle iron in frame 30X30X5 mm (thirty into thirty into five millimeters )so as to give a fair finish including centering , shuttering ,strutting and propping etc. with wooden battens and ballies for all heights of propping and centering below supporting floor to ceiling & removal of same for in-situ reinforced concrete and plain concrete work in . |
| 16 | Foundation ,footing basis of columns etc. And mass concrete as per direction of the Engineer-in-charge including carriage of material with in all leads , lifts in all floor levels and other incidentals. |
| 17 | Flat surfaces, such as soffits of the suspended floors roofs , landing and the like floors etc. up to any thickness , all as per direction of the Engineer-in Charge including s carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 18 | Beams cantilever girders and lintels side and soffits of beams ,beams haunchings, cantilevers ,bressumers and lintels not exceeding 1 mtr in depth in all heights from floor as per direction of the Engineer-in Charge including carriage of material with in all leads ,lifts in all floor levels and other incidentals. |
| 19 | Columns, pillars ,posts and struts square, rectangular or polygonal in plan as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 20 | Stair case with sloping or stepped soffits excluding landing as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 21 | Form work in edges of slab and breaks in floor and walls under 20cm wide as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 22 | Providing tor steel reinforcement for reinforced concrete work including bending and placing in position and cost of binding wire complete for all floors including carriage of material with in all leads and lifts and other incidentals . |
| 23 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20mm nominal size). |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 26 | Providingwoodworkinframesofdoors,windows,clerestorywindowsandotherframes,wroughtframedandfixedinpositionwithholdfastlugsorwithdashfastenersofrequireddia&length(holdfastlugsordashfastenershallbepaidforseparately). Sal wood |
| 27 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 30 mm mm thick : Klin Seasoned & Chemically treated Hollock Wood |
| 28 | ProvidingandfixingwiregaugeshuttersusinggalvanizedM.S.wiregaugeofaveragewidthofaperture1.4mminbothdirectionswithwireofdia0.63mm,fordoors, windows and clerestory windows with hinges and necessary screws Kiln seasoned and chemically treated hollock wood 30 mm |
| 29 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 30 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 31 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 32 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 33 | 300x16 mm |
| 34 | 250x16 mm |
| 35 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 36 | 200x10 mm |
| 37 | Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 38 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 39 | 125 mm |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600x600mm |
| 41 | 6mm(six millimeter)thick cement plaster to ceiling in cement mortar 1:3 (one cement :three sand as per direction of engineer-in- charge including carriage of material with In all leads , lifts in all floors and other incidentals completes |
| 42 | 15mm (fifteen millimeter) thick cement plaster in single coat on rough / fair side of brick /concrete/stone wall for interior plastering for all floors including arises internal rounded angles chafers and / or rounded angles chamfers and/ or rounded angles not exceeding 80mm (eighty millimeters )In girth and finished even and smooth in cement mortar 1:6 (one cement :six sand )as per direction of engineer in charge including carriage of material within all leads lifts in all floors and other incidental |
| 43 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 45 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 46 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 48 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 49 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P.brass pillar tap as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 50 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 51 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 52 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 15 mm nominal bore as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 53 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end25 mm nominal bor as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 54 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 55 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 56 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 57 | 15 mm (fifteen millimeters) nominal bore |
| 58 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 59 | 15 mm (fifteen millimeters) nominal bore |
| 60 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 61 | 15 mm (fifteen millimeters) nominal bore |
| 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 63 | 75 mm nominal size (seventy five millimeters) size |
| 64 | 110 mm nominal size (one hundred ten millimeters) size |
| 65 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 66 | Coupler 75 mm |
| 67 | Coupler 110 mm |
| 68 | Bend 87.5° 75 mm |
| 69 | Bend 87.5° 110 mm |
| 70 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.s per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 71 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. JINDAL or TATA Make Only |
| 72 | Providing and fixing ridges or hips 60 cm overall with 0.60 mm thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating + back coat of po;yster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron Jor L hooks ,bolts & nuts 6 mm dia prepainted G.I. limpet andbitumen washers complete with all accessories as required as per the direction of Engineer - in - Charges. |
| 73 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 74 | Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. |
| 75 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc Kiln seasoned and chemically treatedhollock wood Please Enable Macros to View BoQ information |