Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala 2nd Call Name of Work : Provn of technical library with attached toilet bathroom at 243 armd wksp and provn of storage shed for furniture in BSO yard under GE Kapurthala Contract No : GE KPT- /2025-26 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting out soft/loose soil, including removal of excavated earth upto a distance 500m from starting point complete all as specified and directed by Engr-in-Charge. |
| 3 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or man holes, cesspits etc. not exc 10 Sqm on plan and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge. |
| 4 | Plain cement concrete (1:5:10) type E-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified. |
| 5 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge |
| 6 | M & L form work to sides of concrete foundations, footings, bases of columns, and similar work etc for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. |
| 7 | M & L form work to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular for rough finished surface of concrete all as specified and directed by Engineer - in - Charge. |
| 8 | M & L form work to sides of soffits of plinth beams; lintels beams, roof beams and similar work for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. |
| 9 | M & L RCC M-25 as in foundation including raft, footings, foundation plinth beams bases of columns and the like complete all as specified and directed by Engineer - in - Charge. |
| 10 | M&L for RCC Design Mix M-25 (20 mm graded agg.) in Beams, cantilevers, bressummers, lintels over 1.5m span. |
| 11 | M & L RCC (Design Mix) M-25 (20mm grade) as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge. |
| 12 | M/L for form work to soffits of suspended slabs such as roof slab floor slab not exc 200mm thick with rough finished surface of concrete. |
| 13 | M & L RCC M-25 as in slab supported on walls, beams and column in floor roofs landing the like complete all as specified and directed by Engineer - in - Charge. |
| 14 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregates finished even & smooth without using extra cement complete all as specified and directed by Engineer in charge. |
| 15 | M&L for 25 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates finished even & smooth without using extra cement complete all as specified and directed by Engineer in charge. |
| 16 | M/L for vitrified ceramic tiles light shade tiles 10 mm thick (square/rectangular) polished, area of each tile not exc 0.36 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM (1:6) complete all as specified and directed by Eng in Charge |
| 17 | M/L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles including 15 mm thick cement screed bed in CM (1:6) Complete all as directed by Engineer-in-Charge. |
| 18 | M/L for vitrified ceramic tiles light shade tiles 10 mm thick (square/rectangular) polished, area of each tile not exc 0.36 Sqm in vertical surface such as skirting dados and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 10 mm thick rendering in CM (1:4) complete all as specified and directed by Eng in Charge |
| 19 | M/L for glazed ceramic coloured tiles in vertical surface 300 x 450 x 7mm thick set and jointed in neat cement Paste pointed in white or colour cement to match the colour, including 10 mm thick cement screed bed (1:4) Complete all as directed by Engineer-in-Charge. |
| 20 | M&L for sand filing under floors or in foundations including watering and consolidation |
| 21 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658 - 2006 of 80mm thick ness, M-40 grade with grey cemet and pigment over sand cushioning complete all as specified. |
| 22 | M&L for precast cement concrete block masonary with solid block (size 30x20x10 cm) as in edging ,type B1 1:2:4 (20 mm graded aggregate) exc 10 cm in width and setting in mortar 1:4 complete |
| 23 | M&L for mild steel TMT bars10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge . |
| 24 | - ditto - all as per Srl item No. 22 here in before but 8mm dia and over as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge. |
| 25 | Use and waste of formwork to chajjas and similar items including edges rough finished complete all as specified and directed. |
| 26 | M&L for RCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in chajjas , manhole cover , tank platform etc. complete all as specified and directed by Engineer-in-charge. |
| 27 | S&F ofpPre-cast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers and set in cement mortar (1:4) including form work complete all as specified. (Reinforcement measured separately). |
| 28 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 Complete all as directed. |
| 29 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6.00m mean radius built in cement mortor 1:6 complete all as specified and directed by Engineer-in-charge |
| 30 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified. |
| 31 | M&L for 15mm thick Rendering in CM 1:4 on brick work or concrete surfaces with water proofing compound finished even and smooth etc complete all as specified and directed. Note: WPC shall be paid separately. |
| 32 | M&L for 10mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed. |
| 33 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of whitewash on ceiling over a coat of birla 1.00mm thick white putty complete all as specified and directed by Engr-in-Charge |
| 34 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distermper over a coat birla 2.00mm thick white putty complete all as specified and directed by Engr-in-Charge |
| 35 | M&L for Preparation of new plastered or unplastered decorated surfaces of walls or cornics thereafter applying two coat of exterior emuslion paint and including 2mm thick wall care putty to achieve smooth finish over a coat of appropriate primer complete all as specified and directed by Engr-in-charge. Note- Exterior emulsion paint to be done by Roller. |
| 36 | M&L for Hardcore of broken stone or boulders of gauge n. exc 63mm, deposited spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface complete all as specified. |
| 37 | M&L for 100mm thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in floor over hard core all as specified andm directed by Engr-in-charge. |
| 38 | M&L for 40mm thick plain Cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) as on floor, finishing cement concrete surfaces with slurry even and smooth with using extra cement all as specified and directed by Engr-in-charge. |
| 39 | M&L for Glass divinding strips, 3mm thick ,38mm width inserted in position conforming to design all as specified and directed by Engr-in-charge. |
| 40 | M&L for Anti-Termite Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area |
| 41 | M&L for Anti-termite Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface |
| 42 | M&L for Anti-termite Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area |
| 43 | M&L for 40mm thick in cement concrete Mortar 1:2:4 type B-0, Damp proof course to horizontal or vertical surfaces including necessary formwork all as specified and directed by Engr-in-charge. |
| 44 | M&L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m all as specified and directed. |
| 45 | M&L for polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m all as specified and directed by Engr-in-charge. |
| 46 | S&F of framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing FE-410-W Gde E-250 quality 'A' complete comp[lete all as specified and directed. |
| 47 | S&F of Steel work in tabular trussess including special shaped washer etc complete using ERW or inductrion butt welded tubes conforming to IS 1161-1979 grade St-240 all as specified and direcvted by Engr-in-charge |
| 48 | M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 49 | S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 50 | S&F of 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engr-in-charge. |
| 51 | M&L for 75mm thick PCC 1:3:6 type C2 as in plinth protection finishing the surface even and smooth with out using extra cement complete all as specified and directed. |
| 52 | M&L for providing cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, benching, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating,etc including necessary form work complete. |
| 53 | M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete |
| 54 | S&F of pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x 60mm filling hollow frame complete all as specified and directed. |
| 55 | M&L for PCC 1:3:6 type C2 as in filling of chowkhats complete all as specified and directed by Engineer-in-charge. |
| 56 | S&F of factory made 2nd class, hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to received glass, gauge, etc ( without sash bars) edges of framing plain, chambered or rounded, fitted with cut and mitred beads for securing glass , etc but difided into squares with plain chamfered or rounded mirted and rebated sash bars any numbers sizes of members of shutters as specified and directed by Engineer-in -Charge. |
| 57 | S&F of factory made 2nd class hard wood Plain, framed, panelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge. |
| 58 | S&F of Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt in 200mm |
| 59 | S&F of extruded aluminium alloys handles frabicated type anodized of size 150mm long. |
| 60 | S&F of Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 250mm complete all as specified and directed. |
| 61 | M&L for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 62 | M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over red oxide primer all as specified and directed by Engineer-in-Charge. |
| 63 | S&F of steel window 1.25mm thick Box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Handles of Z Sec 20mm x 100mm long (b) stopper – 01 No per leaf (c) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (d) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (e) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Glass and painting shall be measured and paid separately under appropriate item (ii) Irrespective of whatever shown on drgs, |
| 64 | S&F of steel window 1.25mm thick Box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Wire mesh and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed. |
| 65 | S&F of steel ventilators fixed type with glazing bars etc complete all as specified and directed by EIC. |
| 66 | S&F of 4.00mm thick sheet glass, ordinary quality in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-charge. |
| 67 | S&F of 4.00mm thick figured glass, pinhead type in squares n exc 0.5 sqm each pane and glazing with oil putty all as specified. |
| 68 | S&F of stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.00mm and fixed with tinned tacks/screws with bolts incl leaping wooden complete all as specified and directed. |
| 69 | S&F of 300mm MS ordinary rat rail rod pattern helical springs including roller and roller plate complete all as speicified complete all as specified and directed. |
| 70 | Supply only integral water proofing compound. |
| 71 | S&F of solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening |
| 72 | S&F of Factory made solid PVC panel shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and a gap insert for top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement as specified in SSR Part-II- 2004 SEC 8 CLAUSE 8b1 TO 8b 2.1complete all as specified and directed by EIC |
| 73 | S&F of anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 74 | S&F of anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 75 | S&F of alumunium hinges for PVC door shutter, size of hinges in 100mm |
| 76 | Cutting chases, pinning in, making good to facing through brick wall where reqd and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting exc 10 cm but n.exc 20 cm girth. |
| 77 | S&F of GI tubing 20mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4. |
| 78 | S&F of GI tubing 15mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors. |
| 79 | S&F of vitreous china wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat back closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, jet spray necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacity make white in colour and PVC flush pipe 32mm dia complete. |
| 80 | S&F of vitreous china ware wash basin white, flat back size 550 X 400mm with pedestal including 15mm dia pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia or required length and all necessary inlet, out let connections complete |
| 81 | S&F of 15 mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete. |
| 82 | S&F of concealed 15mm dia of pipe stop valves, chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed . |
| 83 | S&F of 15mm Angle valve fancy type of CP cast copper alloy , with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe and fixed |
| 84 | S&F of PVC connection 15mm dia and 45cm long with two Nos of brass checknuts and washers complete. |
| 85 | S&F of brass Choromium plated shower rose with or without swivel joints 125mm size includingfixing to steel pipe or union complete. |
| 86 | S&F of 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 87 | S&F of PTMT Corner shelf with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) |
| 88 | S&F of of soap-dish chromium plated all as specified |
| 89 | S&F of 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm longfixedwith two plugs (Gutties) of 2nd class hard woodembeded in cement mortor 1:3 with MS screwscomplete all as specified. |
| 90 | S&F of 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge. |
| 91 | S&F of 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge. |
| 92 | S&F of 75 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge. |
| 93 | S&F of 110 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge. |
| 94 | S&F of PVC(SWR) floor trap with CP grating and diameter of outlet 75mm including jointing to waste pipe fixed with solvent cement complete all as specified and directed. |
| 95 | S&F of rotational moulded polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 1000 ltrs capcity incl fittings and as directed by Engr-in-Charge |
| 96 | S&F of 20 mm dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. |
| 97 | S&F of 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. |
| 98 | S&F of 110 mm bore PVC (SWR) vent cowl. |
| 99 | S&F of PVC (SWR) gully trap 125/110 mm setting and jointing with solvent , cement |
| 100 | S&F of 100 mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for nominal bore. |
| 101 | M&L for cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregate as in bed of RCC NP-2 pipe 200mm bore including packing under and haunching against the sides of pipes after laying and testing complete all as specified |
| 102 | M&L for reinforced concrete 150 mm dia pipe class NP-2 laid & jointed complete with collars, complete all as specified and directed. |
| 103 | M&L for RCC Septic tank conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 20 users. |
| 104 | M&L for soakage well excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 m dia X 3.0m effective depth |
| 105 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick using excavated soil. |
| 106 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed. |
| 107 | M&L for point wiring with 1.5 Sqmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 Volts drawn through and including rigid non metalic concealed conduit medium grade ISI marked minimum 20mm size and its accessories complete along with 1.5 sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed, in walls/ ceiling/ roofs with and including 1.2mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting modular switches, socket, bell push, fan regulators etc. as required at site complete all as specified and as directed for the following points :- |
| 108 | One light point controlled by one 1-way switch. |
| 109 | One ceiling / exhaust fan point controlled by one switch. |
| 110 | One three pin socket out let 5 amps on independent board complete. |
| 111 | One three pin socket out let 5 amps on Same board complete. |
| 112 | - ditto - all as per item no 106 above but with 2.5 Sqmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 Volts for one 3 pin socket out let 15 amps on independent board. |
| 113 | S&F of switch type 6A 240 Volts complete all as directed |
| 114 | S&F of switch type 15A 240 Volts complete all as directed |
| 115 | S&F of ceiling rose surface type Bakelite 65 x 50 mm with three terminals complete all as directed |
| 116 | S&F of socket outlet 2 in 1, 3 pin, 5/6 amp 2 module type with shutters complete. |
| 117 | S&F of socket outlet 2 in 1, 3 pin, 5 and 15 amp type 2-module shutters complete. |
| 118 | S&F of lamp holder, PVC/Polycarbonate angular type LED lamp base B-22 (holder type) 7 watts complete all as directed |
| 119 | S&F of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CMM with service value 6.00 BEE with brushless direct current motor (BLDC) with remote controle (Colour of ceiling fan wil be approved by GE) complete all as specified and directed. Make : Philips/Crompton/Havells |
| 120 | Supply and Metallic Heavy duty Exhaust fan copper wound heavy duty with louvers, with fixing arrangements & making hole of suitable size if necessory for 300 mm sweep, 900 rpm, 240V, Make Havells cat pt no Turbo force SP or equivalent in Bajaj, Khaitan, C&G. |
| 121 | S&F of LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders,including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed. Make : Philips/Crompton/Havells |
| 122 | S&F of LED light fitting mirror type with high out put diffuser 2 feet, 10/16 watt, 220 volt AC decorative type with driver, holders,including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed. Make : Philips/Crompton/Havells |
| 123 | S&F of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with GI bracket of dia 40mm light grade of suitable size with complete. Make :Crompton/Philips/Luker LMR 10 |
| 124 | S&F of LED decorative wall Lights 20 W 230 V complete all as directed at site. Make: Philips : Grace Wall light/ Havells/Crompton |
| 125 | S&F of sheet steel factory made, powder coated MCB DB with bus bar 200Amps. Neutral link, Earth bar, double door SPN 8 way 230volts all as directed. Make- L&T/Legrand/Havells |
| 126 | S&F of single pole and neutral enclosure with a two pin and earth with single pole MCB 20 Amp Make :Havells/L&T/Legrand. |
| 127 | S&F of MCB Single pole 240 volts 6-32 Amps, 10KA, B-series, Make- L&T/Legrand/Havells |
| 128 | S&F of MCB SPN 240 volts 06- 32 Amps, 10KA, B-series Make- L&T/Legrand/Havells |
| 129 | S&F of electric water heater, storage type ABS body with mettalic inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, Mounting bolts, 450 mm long steel braided connection piece with end terminal of brass etc |
| 130 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. Make : Havells/Polycab/Gloster |
| 131 | M&L for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. |
| 132 | M&L for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed. |
| 133 | S&F of GI tubing medium grade 25 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item) |
| 134 | S&F of replacement of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 25 mm bore complete all as specified. |
| 135 | S&F of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engineer-in-Charge. |
| 136 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty armoured cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armouredwith galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section two core in service connections |
| 137 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 4 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 138 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. |
| 139 | Taking down unserviceable MCB’s and supply & fix following type/rating MCB’s including necessary connection as under:- |
| 140 | S&F of MCB, 10 to 32 Amp, SP, 240 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard |
| 141 | S&F of MCB, 25 to 32 to Amp, SPN, 240 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard |
| 142 | Supply, installation, comissioning and testing of LT outdoor panel board (factory made of approved CPRI) not less than 150cm * 100cm * 50cm mounted indoor type made out of CRCA sheet 3.15 mm thick dust proof, powder individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply inlcuding bus bar chamber and copper bus bar of capacity 200 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable inlcuding fitted on 50 * 50 * 6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following :-(i) Electrolite copper bus bar 200 Amps for phase & Neutral - 04 Nos(ii) MCCB TP 63 Amps, 10 KA, I Cs =100\% of Icu having thermal & magnetic setting provision - 01 Nos(iii) MCCB SPN 6 to 32 Amps, 10 KA - 06 Nos(iv) Multi functional digital voltmeter and ampere meter including suitable and appropriate CTs-01 Set(v) Indicator lamp (LED RYB) -01 Set Total in Figures 0.0 23 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail