| 1 | RMO of Fire Fighting System, Fire alarm system, P.A System, CCTV system, EPBAX system, DG Set & IEI i/c minor repair & material at Nasirpur as per term & condition and inventory attached by deploying following staff:-a) Operators 1 No. In general shift as and when required.b) Khallasi– 1 No. Fortnightly as and when required. c) Wireman Grade-I – 1 No. - shall attend the sites of work between 9:00 A.M. to 5:00 P.M at least once in a fortnight and as and when required.(Note:- The agency shall arrange for obtaining NOC from Delhi Fire Service as per term & condition attached.) |
| 2 | RMO IEI, fire fighting system, fire alarm system & PA system at community hall, mirzapur, Dwarka as per term & conditions and inventory attached by deploying following staff:-a) Operators 1 No. In general shift as and when required.b) Khallasi– 1 No. Fortnightly as and when required. c) Wireman Grade-I – 1 No. - shall attend the sites of work between 9:00 A.M. to 5:00 P.M at least once in a fortnight and as and when required. (Note:- The agency shall arrange for obtaining NOC from Delhi Fire Service as per term & condition attached.) |
| 3 | Supplying & replacement of following accessories/items i/c connection, installation, commissioning, testing etc. in all respect complete as required.2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 4 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 5 | 4 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 6 | S.P. 5/6 amps, one way switch, piano type ISI marked. |
| 7 | S.P. 15/16 amps, one way switch, piano type ISI marked. |
| 8 | 6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked. |
| 9 | 6 amps. to 32 amps. ratings , SP MCB, “C” curve, 10 KA breaking capacity. |
| 10 | 32 amps, DP MCB, “C” curve, 10 KA breaking capacity. |
| 11 | 3 pin, 5/6 amps socket outlet, piano type ISI marked. |
| 12 | Pvc flexible conduit 25mm. |
| 13 | Supplying & replacement of suitable size of phenolic laminated sheet 3mm thick cover in front etc. as reqd. i/c cutting for switches / socket, fixing of piano type switch, connection testing etc. as required. |
| 14 | LED Batten light (System lumen efficacy >105<120lm/Watt)Supplying, installation, testing & commissioning of LED surface mounted Batten light of following body material and construction as per IS:10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating volatge AC 140-24 volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10% P.F.> 0.95, IP-20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000 K/ 4000K/ 5700K/6000K/6500K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be relevant BIS standard and trade mark certificate (T.C.). Manufacturer Word Mark/Name Engraved/Embossing/Screen printing on housing complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >105<120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90OC). CRCA sheet body (thickness > 0.50mm)a) 18-22 watt |
| 15 | Supplying & replacement of following capacity of capacitor in the existing desert cooler/fan i/c connection, testing etc complete as required. A)3.15 MFD |
| 16 | Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos., canopies, shackle kit, safety rope, copper winding, steel/AI body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including saferty pin, nut bolts, washers, temperature rise = 75 degree C (max.) insulation resistance more than 2 mega ohm, suitbale for 230 V, 50 Hz, single phase AC Ceiling Fan complaint to IS 374:2019 fan supply, earhting etc. complete as req.a) 1200 mm, service value > 5.1 CM/Min/Watt, air delivery 130 CM/Min. |
| 17 | Dismantling the existing damaged /burn out ceiling fan of 1200 mm sweep and rewinding the same with copper winding and replacement of ball bearing etc. and fixing the ceiling fan i/c connection, testing complete as required. |
| 18 | Lowering of submersible pump set in the existing bore with G.I. pipes i/c replacement of existing nuts & bolts, connections of delivery line, valves cable jointing, testing etc. completed as reqd. |
| 19 | Lifting of submersible pump sets along with G.I. pipes and accessories i/c dismantling of pump set from delivery line etc. complete as reqd. |
| 20 | Supplying & replacement of suitable size polycarbonated double combined junction box i/c providing & fixing 2 no. 6 pin 5/6 & 15/16 amp socket outlet & 2 no. 15/16 piano type switch, connections etc. complete as required. |
| 21 | Repairing, rewinding & servicing of 5 HP submersible motor pump set (Single phase) i/c refixing the delivery line with the pump sets, painting, connection, dismantling & testing etc. complete as required. |
| 22 | Painting of Fire Fighting all equipments like MS pipes of all size(150mm,100mm,80mm,65mm,50 mm,40mm,32mm & 25 mm dia etc. required at site),fire hydrant boxs,hose cabinets, MS fire shaft doors,FF panels , pumps & motors etc. along with bracket/clamp etc with minimum two coats of synthetic enamel paint of approved brand and manufacture of required shade after cleaning the surface of the same etc. complete as reqd.(Civil DSR 2023 item no. 13.99) |
| 23 | Refilling of existing ABC type portable fire extinguisher capacity of 5 kg including dismantling, removing the existing gas and re-fixing in the same position complete as required. (Nasirpur) |
| 24 | Refilling of existing CO2 type portable fire extinguisher capacity of 4.5 kg including dismantling, removing the existing gas and re-fixing in the same position complete as required. (Nasirpur-4, Mirzapur-6) |
| 25 | Refilling of existing ABC type portable fire extinguisher capacity of 9 kg including dismantlling, removing the existing gas and refixing in the same position complete as required. (Mirzapur) |
| 26 | Refilling of existing water type portable fire extinguisher of capacity of 9 ltr. including dismantlling, removing the existing gas and refixing on the wall in the same position complete as required.(Mirzapur) |
| 27 | Refilling of existing Mechanicl Foam (CO2 Gas cylinder operated) type Wheel mounted fire extinguisher of capacity of 135 liters including dismantlling, removing the existing gas and refixing in the same position complete as required. (Mirzapur) |
| 28 | Refilling of existing water type (Gas cartridge) trolley type fire extinguisher of capacity of 50 liters including dismantlling, removing the existing gas and refixing in the same position complete as required.(Mirzapur) |
| 29 | Servicing of 45 KVA D.G Set of Ashoka Leyland Make i/c replacement of lubrication oil, mobil oil, air filter, oil filter, coolant in radiator, diesel filter, battery terminal etc. complete as required i/c rebate for dismantle material complete as required. (Nasirpur) |
| 30 | Servicing & overhauling of 50 HP Electric driven Main fire Pump Set i/c greasing, painting and re-fixing the same after effecting necessary repairs / replacement of all internal defective parts etc., testing & commissioning, complete as required i/c rebate for dismantle material.(Mirzapur) |
| 31 | Servicing & overhauling of 50 HP Diesel driven fire pump set i/c painting, greasing, coolant topping, lube oil change, and re-fixing the same after effecting necessary repairs/replacement of all internal defective parts etc. testing & commissioning, complete as required i/c rebate for dismantle material.(Mirzapur) |
| 32 | Servicing & overhauling of 3 HP Electric Driven Jockey Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required i/c rebate for dismantle material.(Mirzapur) |
| 33 | Repairing of 1.5 HP Dewatering Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required i/c rebate for dismantle material.(Mirzapur) |
| 34 | Servicing of 5.5 HP Clear water booster Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required i/c rebate for dismantle material.(Mirzapur) |
| 35 | Repairing & overhauling of 7.5 HP Terrace Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required i/c rebate for dismantle material.(Mirzapur-1 Nasirpur-2) |
| 36 | supplying of high speed diesel for operation of DG set i/c cartage, storage, filling and arrangement of minimum 200 ltrs capacity tank at site in tank etc. complete as required. Please Enable Macros to View BoQ information |