Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL |
| 2 | Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area |
| 3 | Earthwork in excavation over areas by mechanical/manual means in all type of strata upto a depth of 3 meters comprising any of the materials such as soil, silt, sand, clay, gravels, moorum of all varieties, shingles, pebbles, all types of conglomerates, all types of laterite rock, soft rock, disintegrated rock, fissured/ shattered/ decomposed rock or weathered rock and all such other materials as described under appendix to these specifications whether in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiselling, wedging etc. in all conditions such as dry, moist, saturated, submerged, foul conditions etc.blasting prohibited including pumping or bailing out water including segregating the excavated earth/rock and disposal of surplus excavated earth at contractors identified site(at risk and cost of the contractor)for all leads and lifts and as directed by Engineer . |
| 4 | Earthwork in excavation for foundation pipeline trenches by mechanical/mannual means in all type of strata comprising any of the materials such as soil, silt, sand, clay, gravels, moorum of all varieties, shingles, pebbles, all types of conglomerates, all types of laterite rock, soft rock, disintegrated rock, fissured/ shattered/ decomposed rock or weathered rock and all such other materials as described under appendix to these specifications whether in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiselling, wedging etc. in all conditions such as dry, moist, saturated, submerged, foul conditions etc. blasting prohibited including pumping or bailing out water including segregating the excavated earth/rock and disposal of surplus excavated earth at contractors identified site at risk and cost of the contractor) for all leads and lifts and as directed by Engineer . |
| 5 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers (excluding rock) not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer. |
| 6 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 7 | Pre-cast cement concrete solid blocks masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 corase sand ) in partition walls size of blocks (30 x 20 x 10) |
| 8 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand in foundation upto plinth level |
| 9 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand in foundation upto plinth levelExtra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 10 | Providing and fixing Exposed laterite cladding 75mm thick with Patradevi laterite stone on concrete pillars as shown in the drawings, including 12mm cement plaster on concrete surface 1:3 (1cement 3: fine sand), chamfering the edges, filling the joints with matching colour pigments, including polishing the same with non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by the engineer, etc complete. |
| 11 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:b. In retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level. |
| 12 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:a) All works upto plinth level |
| 13 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) a) All works upto plinth level |
| 14 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) b) In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level |
| 15 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) c) In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level |
| 16 | Reinforced cement concrete work 1:1½:3 (1 cement: 1½ coarse sand: 3 granitic or basaltic stone aggreate 20mm nominal size excluding plastering and cost of centering, shuttering & reinforcement, in sloping or battering surface (slabs, beams, louvers, etc)i) Where inclination to the horizontal does not exceed 30° |
| 17 | Centering & shuttering including Strutting, Propping & removal of forms for :i) Foundations, Footings, Bases for columns |
| 18 | Centering & shuttering including Strutting, Propping & removal of forms for :ii) Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like |
| 19 | Centering & shuttering including Strutting, Propping & removal of forms for :iii) Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan) |
| 20 | Centering & shuttering including Strutting, Propping & removal of forms for :iv. Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 21 | Centering & shuttering including Strutting, Propping & removal of forms for :viii. Arches, domes, vaults upto 6.00 span |
| 22 | Centering & shuttering including Strutting, Propping & removal of forms for :ix.Extra for arches, domes, shell roofs exceeding 6m. Span. |
| 23 | Centering & shuttering including Strutting, Propping & removal of forms for :x. Domes, vaults, shell roofs having curved surface in both the directions. |
| 24 | Centering & shuttering including Strutting, Propping & removal of forms for :xiii. Suspended floors, roofs landings, shelves & their supports |
| 25 | Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded platesi. Where inclination to the horizontal does not exceed 30° requiring shuttering on the underside only |
| 26 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) )(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 27 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 28 | Providing and fixing Colouron Plus galvulium roofing Sheets of 0.5mm thick double ribbed trapezoidal profile coated 1080mm with cover width of 1020mm including all the accessories (JSW or equivalent make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 29 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 30 | Providing and fixing PVC SWR pipes confirming to IS 13592 type A including jointing with seal ring confirming to IS 5382 leaving 10 mm gap for thermal expansion.b. Single socketed pipe 110 mm dia |
| 31 | Providing and fixing Prince or equivalent make PVC SWR half round eaves gutter with bolts, nuts and flat iron brackets 40 x 3 mm size complete.a. 140 mm nominal size |
| 32 | Providing and fixing prefabricated gate of M.S hollow sections 49.5x49.5x4.5mm with 12 mm M.S square bars of M.S grill work as per drawing including providing and fixing locking arrangement,pintals,holdfasts embedded in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 granitic or basaltic aggreate 20 mm nominal size)including applying priming coat with ready mixed red lead paint and painting two or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per directions complete. |
| 33 | Providing and Fixing Mild Steel drain cover of 900mm width with 75x40x5mm channels and 40x40x5mm angles, flat bars 40x5mm per running meter applying one coat of primer and two coats of painting etc complete as directed by Engineer-In-Charge |
| 34 | Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon.d. Second class matti wood |
| 35 | Providing and fixing 35 mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including anodized aluminium butt hinges with necessary screws:b. Second class Indian teak wood |
| 36 | Providing and fixing bright finished brass sliding door bolts with nuts and screws etc completea. 300 x 16 mm |
| 37 | Providing and fixing bright finished brass door latch with necessary screws etc completea. 300x 16 x 5 mm |
| 38 | Providing and fixing BRASS ALDROP 10\\" X16 MM ANTIQUE FINISH with necessary screws etc complete including all tools, plants, labour and materials, leads, lifts etc complete. as as per the manufacturers specifications and directed by Engineer-In-Charge. |
| 39 | Provided and fixing 150 mm chromium plated brass floor door stopper with rubber cushion screws etc. to suit shutters thickness complete. |
| 40 | Providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete.a. 250 x 10 mm |
| 41 | Providing and fixing Stainless steel D type handles with necessary screws etc complete a) L 300mm/325mm x 22 to 25mm dia |
| 42 | Wood Finish Foam Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system, with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) along with printed matt having wooden textures, used along with UV Resistant resin to give the clear wooden texture on the door. The core of shutter will be filled as specified (Expanded Polystyrene Foam / Polyurethane Foam (EPS/PU) Foam) The shutter to be water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) Technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory.Accessories:i) S. S. Hinges 4” - 3 Nosii) S. S. Latch - 1 Noiii) Tower Bolt 5” - 2 Nosiv) Handle 5” - 2 Nosshutter thickness b) 35mm |
| 43 | FRP (Fiber Reinforced Polymer) Frames with Wood FinishManufacture, Supply and Installation (with anchor fastener) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) Frame of cross section as per options below with right angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2015 certified company.Specified Cross Sectionb) 4” x 2” |
| 44 | Supply and installation of Aluminium Louvers. The frame should be made of Aluminium tubes of size 100x50X1.50 mm thk and 50X25x1.50 mm thk C channels. Aluminium Z shaped louvers of 100mm should be fixed to the supporting frame with aluminium cleats, GI screws, etc complete. The whole assembly is powder coated with pure polyester paint. (MS framing to be paid separately) |
| 45 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 46 | 6mm cement plaster to ceiling 1: 4 (1 cement : 4 fine sand) |
| 47 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 48 | Neat Cement punning |
| 49 | Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent |
| 50 | Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)a) 20 mm thick. |
| 51 | Jaisalmer stone flooring with 18mm thick polished Jaisalmer stone over 20mm (average) thick base of CM 1:4 (1 cement : 4 Coarse sand) with joints finished flush |
| 52 | Providing and fixing vitrified glossy finished (600x600) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 53 | Providing and fixing of 18mm thick Mirror Finish Cat Eye Granite slab for urinal partitions with cement etc complete including rounding and polishing of the edges as directed by Engineer-in-Charge |
| 54 | Providing and fixing vitrified antiskid tiles (320x320) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 55 | Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.b. Wall Ceramic Glazed Tiles : 300 x 450 |
| 56 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm c) Elite Brown |
| 57 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm a) Jet Black |
| 58 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. a. 60 mm thick in all colours except grey (M35 grade) |
| 59 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 60 | Finishing wall with superior quality waterproofing cement paint (super snow hem or equivalent) of required shade on new work (three or more coats) to give an even shade. |
| 61 | Applying priming coat with ready mixed red lead paint of approved brand and manufacture on steel work. |
| 62 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture in all shade or new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture to give an even shade |
| 63 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 64 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 65 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 66 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture(such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 67 | Protective coating -Paint with Emce Colourflex of MC Bauchemie or Equivalent with a priming coat @100 g/m2 & main polymer coating thickness 200 225 microns @400-450 g/m2 for two coats with approved shades including cost of materials, cleaning, preparing the surface,chipping,removing loose dirt with wire brush & water ,labour for filling holes, cracks, joints etc.with one component polymer modified fine repair & cosmetic mortar,labour for applying above coating,scaffolding charges etc with all taxes complete as per IRC SP:80 Clause 6.5.1 & clause 2808 of MORT& H specifications latest edition. |
| 68 | Proving and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) size 580 mm with 100 mm sand cast iron P. or S trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mm diameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required.b. Orissa pattern W.C. pan |
| 69 | Providing and fixing white vitereous china pedestal type (Europen type) water closet with seat as lid, whth C.I. brass hinges and rubber fitings 15 lts white vitreous china low level flushing cistern with fittings as brackets 40 mm white precelain 3enameled flush bad, 25 mm overflow pipe with specials and mosquito proof coupling of approved municipal design complete, including cutting and making good the walls and floors where required.a. W.C. pan with white plastic seat and lid |
| 70 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 430 x 265 mm sizes respectively with pvc automatic flushing cistern with fittings, R.S. or C.I. brackets, standard size galvanised steel flush pipe and spreaders with brass unions & G.I. clamps complete, including painting of cister and fittings, cutting and making good the walls and floors where required.b. Range of two urinal basin with 10 litres pvc. Automatic flushing |
| 71 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required.a. Flat back wash basin size 630 x 450mm with a pair of 15 mm C.P. brass pillar taps. |
| 72 | Providing & fixing (4’) 100 mm S.S grating for gully floor or nahni trap. |
| 73 | Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws.b. 600x20 MM SIZE |
| 74 | Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw |
| 75 | Providing and fixing ball valve (brass) of approved quality :b. Low pressure with copper. floats2. 20mm nominal bore |
| 76 | Providing and fixing ball valve (brass) of approved quality :b. Low pressure with copper. floats3. 25mm nominal bore |
| 77 | Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore:c. 45 cm (18”) length . |
| 78 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.c. 1000 lit. capacity |
| 79 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design :b. 150 x 100 mm size –P or S type |
| 80 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1: 11/2:3 mix (1 cement: 1 1/2 coarse sand : 3 graded stone aggregate 20mm nominal size foundation concrete 1: 11/2:3 mix (1 cemet:1 1/2 coarse sand :8 graded stone aggregate 20mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. b. Inside size 90 x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg.) |
| 81 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1: 11/2:3 mix (1 cement: 1 1/2 coarse sand : 3 graded stone aggregate 20mm nominal size foundation concrete 1: 11/2:3 mix (1 cemet:1 1/2 coarse sand :8 graded stone aggregate 20mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. d. Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 82 | Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design. |
| 83 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketeda. 110 mm dia |
| 84 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketedb. 75 mm dia |
| 85 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.a. 110 mm dia |
| 86 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.b. 75 mm dia |
| 87 | Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door :a. 100 mm dia |
| 88 | Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door :b. 75 mm dia |
| 89 | Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door:a. 100 mm dia |
| 90 | Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door:b. 75 mm dia. |
| 91 | Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door :a. 110 mm dia |
| 92 | Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door :b. 75 mm dia |
| 93 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door :b. 75 mm dia |
| 94 | Providing and fixing U.P.V.C. pipe clips (approved make ) for S.W.R. pipes :a. 110 mm dia |
| 95 | Providing and fixing U.P.V.C. pipe clips (approved make ) for S.W.R. pipes :a. 75 mm dia |
| 96 | Providing and fixing R.P.V.C. vent cowlb. 75 mm dia |
| 97 | Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993 a. 15mm nominal bore |
| 98 | Providing and fixing NICKEL chrome plated copper alloy Fancy two way long body bib cock with wall flange of approved make. Confirming to IS 8931;1993 a. 15mm dia nominal bore |
| 99 | Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with slinding flance 15 mm Jaquar make or equivalent. Confirming to IS 8931;1993 a. 15mm nominal bore |
| 100 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).e. 40 mm outer dia CPVC pipe |
| 101 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. a. 15 mm dia nominal outer dia pipes. |
| 102 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. b. 20 mm dia nominal outer dia pipes. |
| 103 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe) c. 25 mm nominal outer dia pipes. |
| 104 | Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete. |
| 105 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 106 | Providing & fixing angular stop cock with wall flange of 20 mm dia bore without tap. Of first quality chrome. JAGUAR FLR-5053N or equivelant etc. complete |
| 107 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. |
| 108 | Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead. |
| 109 | Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 110 | Dismantling steelwork in built up sections in angles, tees, flats and channels including all gusset plates bolts, nuts, cutting dismembering and staking within 50 mts. Lead |
| 111 | Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm. |
| 112 | Dismantling asbestos sheet roofing including ridges, hips valley and gutters and stacking the material within 50 meters lead. |
| 113 | Carraigeway and Disposal of unserviceable building material, Laterite stone, demolished concrete, excavated earth upto a lead of 15 kms from the site of execution by means of tipper truck including loading, unloading and dumping/stacking as directed by Engineer -in-charge. |
| 114 | Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification.a. Size 30 cm L x 50 cm H x 15 cm T |
| 115 | Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge B) 75mm dia |
| 116 | Providing and Installating of Synthetic wood and G.I with powder coating WITH BACKREST LENGTH X HEIGHT X WIDTH 60'' X 38'' X 20'' POWDER COATED FINISH including foundation, holding down bolts, grouting etc complete as directed by Engineer-in-charge. |
| 117 | Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building.a. Pre-construction |
| 118 | Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment). |
| 119 | Spreading of sludge, dung manure or/and good earth in required thickness (cost of sludge, dung manure or/and good earth to be paid separately). |
| 120 | Filling mixture of earth & sludge or manure in the desired proportion in trenches flooding withwater and leveling (cost of supplying earth and sludge of manure and mixing excluded). |
| 121 | Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm. as per MORTH Specification 307 |
| 122 | Maintenance of lawns or Turfing of slopes(rough grassing) for a period of one year including watering etc. as per MORTH Specification 307 |
| 123 | ELECTRICAL |
| 124 | Supply, installation, testing and comissioning of Architectural designed Pole of 3mtr Height Post top pole made of galvanised iron sections of 114mm & 60mm dia. This architecturally designed pole is structurally sound. Windspeed considered in design 50m/s, IS875:PART 3:1987, Material for tubes steel of grade YST210. Material for base plate steel of grade E250 to IS2062; 2011. The pole will be provided with an inbuilt junction box to fix 32Amp Connectors & 6Amp MCB inside the cut window of the bottom pipe the inbuilt box should have a flush door of suitable size with Allenkey locking on bothside. The Decorative pole will be mounted on a square base plate of size 200X200mm having 10mm thickness. The base plate shall have 4 hole suitable for M16/450 foundation bolts ensuring firm grouting in the specially designed RCC foundation. The galvanized zinc coat should not be less than 65+/ 10microns. The Galvanised pole should be painted in 3layer coating (Coating thickness should not be than 80microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy zinc primer & 3rd final layer with PU Paint with overall 100 +/- 10 microns. Make : Havels, Raytek, suncity, dwarka casting subjected to approval of sample by engineer in charge Exclusive of MCB and 3c 2.5 sq mm wire from MCB to Fitting |
| 125 | Supply ,Installation Testing , Commissioning 40W decorative luminaire made of spun aluminium body with pressure die-cast heat management (PDCHM) and the IP65 optical compartment with high power LED/s is comprised of a deep drawn chemically polished and co-extruded, thermoformed polycarbonate protector stabilized agent UV rays suitable for 40W LED. Fitting shall be Post top mounting type fixture. System Wattage: 40W LED, Protection class:IP65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:1200- 277Vac, Operating Temperature: 0deg to +50deg C, single phase ac supply.● light Source : Bridegelux, LED Lumens:6000lm, CRI(Ra):>80, LED Colour Temperature: 4000K, Life Span:>59,000 Hours,, ● Physical Body: Die cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate glass, Mounting: Suitable for 48mm OD Pipe, Finish: Powder Coated Black, ●Driver Power Factor:>0.95, THD:<7.8%,Surge Protection: 4KV, Efficiency:>87%. Fitting should have inbuilt driver with efficiency >0.9 and having surge protection device of 4KVA and external surge protection device of 10KVA make Philips. LED's of Osram & Driver to be of make Philips. LM79-2019 report to be provided. Make : Havels, Raytek, suncity, dwarka casting subjected to approval of sample by engineer in charge and with other required accesories. |
| 126 | Supply, installation , testing and comissioining of spike uplighter LED light of 8 to 9 watts including the suitable driver and other acceories complete as required. (Makes: Havells/ Reytek/Wipro/jaquar) |
| 127 | Supply installation testing and commissioning of 30 W Flood Light made out of Pressure die-cast aluminium housing with specially designed optics, provide uniform light distribution to redefine outdoors and enhance architectural design with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.(Makes: Havells/ Reytek/Wipro/jaquar) |
| 128 | STREET LIGHT PANEL: Supplying, installation testing and comissioining of three phase, 415V, street light control panel up to the max load of 6kW, Incomming -TPN MCB 40A, Outgoing- 32A TP 2 Nos; 6A-32A ,SP MCB C Series-5 Nos. powder coated CRCA 14 SWG sheet,outdoor type, having IP68, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation and provision to fix energy meter complete as required and conforming to the requirements of Goa Electricity Department. |
| 129 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 1/2 Core 35 sq.mm |
| 130 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.4 Core 10 sq.mm |
| 131 | Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 Core 2.5 sq.mm |
| 132 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required |
| 133 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.(2) 3 1/2 x 35 Sq. mm. |
| 134 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (4) 4 x 10 Sq. mm. |
| 135 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (1) 3 x 1.5/2.5 Sq. mm. |
| 136 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.(a) In soily strata |
| 137 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.(a) In soily strata |
| 138 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required |
| 139 | Supplying of HDPE pipes at store or site of work including loading unloading, stacking , transit insurance etc complete bearing ISI mark & conforming to IS: 4984-1995 & made frm PE 100 resinouter dia in mm 75 |
| 140 | Conveying carefully from stack at site, 250 m from both sides rolling and lowering in trenches, laying true to line and level and perfect linking for joints for PVC / HDPE complete in all respect as per the direction of the engineer incharge75 mm OD |
| 141 | Supply, installation , testing and commissioning of Terminal Boxes size 130 x 130 x 77 mm with 9 Nos 4 sq.mm Terminals. Box shall be similar to Hensal make Cat. No. DK 0606 g, IP 65, |
| 142 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.(c) Group C -- with Cat A Modular Accessories |
| 143 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. |
| 144 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent surface/ recessed FRLS PVC conduit of appropriate size as required.(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 145 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent surface/ recessed FRLS PVC conduit of appropriate size as required.(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 146 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/16 A modular switch connection painting etc. as required.(a) Cat A |
| 147 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required.(a) Cat A |
| 148 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required(a) Cat A |
| 149 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as requiredCat A |
| 150 | Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required. |
| 151 | Supply and erecting of 12 inch (300 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories.CAT A |
| 152 | Supply and erecting of 56 inch ( 1400mm sweep) ceiling fan, double ball bearing type, complete with all accessories. (a) Cat A |
| 153 | Supply, Erection,Testing & Commissioning of 20 W LED TubeLight luminaire.with required Driver and other accessories of Wipro, crompton, Bajaj, havels or equivalent make approved by Engineer - in - Charge complete as required. |
| 154 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)(d) 16 way single door Cat A |
| 155 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (a) SP, Cat A |
| 156 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (e) TPN, Cat A |
| 157 | Supplying and fixing SP blanking plate in the existing MCB DB complete as required |
| 158 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Deaprtment. |
| 159 | Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only. (b) 10 to 40 A |
| 160 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the EngineerIncharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately). (a) In soily strata |
| 161 | Extra for using salt and charcoal for pipe earth electrode asrequired( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 162 | Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required |
| 163 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop arthing along with existing surface/ recessed conduit/ submain wiring/ cable as required Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy