|
| 1 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 3 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: Ordinary Rock |
| 4 | Providing and Laying of Stone Soling hand packed including ramming, dressing and watering etc. with all cost and carriage of materials upto site of work complete. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 10 | Backfilling with 2nd class sand/ stone dust/ boulders inside plinth including watering, ramming, rolling etc including carriages of materials from approved source to site of work complete as per the directions of Incharge Engineer. |
| 11 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 12 | Providing wood work in frames of doors. Windows, arch windows, ventilators, wrought frames (chowkats) and other frames, wroutht framed and fixed in position with all necessary fitting/ fixtures complete. First Class KD wood. |
| 13 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 17 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position angles/ flats/ tubles including MS sheet for cheeja, soffits and eaves boarding and applying a priming coat of approved steel primer all complete. |
| 18 | Providing and fixing with Colour coated High rib profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks,fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters complete as per the directions of Incharge Engineer. 0.50mm thick including carriages by mt |
| 19 | Providing ridges, hips and valleys of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 20 | Providing and Applying of 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 21 | Providing and applying of 2mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 24 | Providing and fixing of 35mm thick Imported KD Wood glazed shutters for doors, windows and clerestory windows including ISI marked M.S pressed Butt Hinges bright finished of required size with necessary screws other fittings/ fixtures and glazing for window shutters complete as per the directions of Incharge Engineer. |
| 25 | Providing and fixing of 35mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge: Imported KD Wood. |
| 26 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Ply wood 5 ply, 9 mm thick Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type |
| 27 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 29 | Providing and fixing of ISI marked Aluminium fittings of standard quality and make for doors and windows of following size including screws, nails etc complete. |
| 30 | Handles 150mm |
| 31 | Handles 100mm |
| 32 | Hooks 150mm |
| 33 | Concealed Locks 200mm (Link lock type of approved brand and make.) |
| 34 | Tower Bolts 150mmx 10mm |
| 35 | Tower Bolts 100mmx 10mm |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 37 | Providing and laying 18mm thick gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in Charge. |
| 38 | Ornamental steel work welded in built up section/ framed works including cutting, hoisting, fixing in position and applying a primimg coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladders, railings, brackets, gates & similar works. |
| 39 | Providing and fixing of 10mm thick ply wood in room ceiling including supporting structure 3\\"x3\\" wooden joists and 50x 50mm wooden cornice at corners, 2'0\\"x2'0\\" pannels where ever required, (2' x2' mesh of wooden Joists) beadings nails and other fittings fixtures complete as per the directions of Incharge Engineer. |
| 40 | Providing and fixing of Imported KD supporting joists in rooms, chejja and fixed in position with all necessary fitting/ fixtures incl carriages complete. |
| 41 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 42 | Providing and Laying of Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate. |
| 43 | Providing and Fixing of Heavy duty glass panes 3.5mm thick instead of ordinary glass panes 13.75kg/sqm in doors, windows and clerestory window shutters (Area of opening for glass panes excluding portion inside shall be measured) including cost of beadings nails etc complete. |
| 44 | Supplying and fixing of 25mm dia RIGID PVC conduits 1.8mm thick (ISI marked complete with accessories such as bends, junction, pull boxes etc in recess or on surface including cutting chases in the walls/ floors and making good the same complete as required as per the directions of Incharge Engineer. |
| 45 | Supplying and fixing of 20mm Thick PVC Flexible conduits 1.8mm thick (ISI marked complete with accessories such as bends, junction, pull boxes etc in recess or on surface including cutting chases in the walls/ floors and making good the same complete as required as per the directions of Incharge Engineer. |
| 46 | Lighting point (one lighting point includes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement.One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work including cost of service line. |
| 47 | Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire,16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work. |
| 48 | Providing and fixing one fan point includes wiring for lighting points in 1.5sqmm pvc insulated copper wire and 2.5sqmm pvc in multi -strant copper wire including 1200mm ceilling fan electronic fan dimmer.6Amp s pole MCB-10AMP DP MCB 2 Way DB for housing MCB or lightting circuits and hylem sheet.including Placing and fixing in position Fan clamp boxes with MS Fan clamps connected with network Conduit pipes with necessary fittings in RCC Work |
| 49 | Carriage of materials from approved source to site of work complete. |
| 50 | Stone aggregate for an average lead of 3Kms |
| 51 | Sand for an average lead of 20Kms |
| 52 | Bricks for an average lead of 60Kms. Please Enable Macros to View BoQ information |