| Sl. No. | Item Description |
| 1 | CIVIL WORKEarth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge. |
| 2 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. Building |
| 3 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge Building |
| 4 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI) |
| 5 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6\\") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge. |
| 6 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. |
| 7 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 8 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Stilt Floor |
| 9 | First floor |
| 10 | Second floor |
| 11 | Third Floor |
| 12 | Fourth Floor |
| 13 | Fifth Floor |
| 14 | Sixth Floor |
| 15 | Seventh Floor |
| 16 | Eighth Floor |
| 17 | Ninth Floor |
| 18 | Tenth Floor |
| 19 | Terrace Floor |
| 20 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. First floor |
| 21 | Second floor |
| 22 | Third Floor |
| 23 | Fourth Floor |
| 24 | Fifth Floor |
| 25 | Sixth Floor |
| 26 | Seventh Floor |
| 27 | Eighth Floor |
| 28 | Ninth Floor |
| 29 | Tenth Floor |
| 30 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. Footing. |
| 31 | Plinth Beam |
| 32 | R.C.C Column -Stilt Floor |
| 33 | First floor |
| 34 | Second floor |
| 35 | Third Floor |
| 36 | Fourth Floor |
| 37 | Fifth Floor |
| 38 | Sixth Floor |
| 39 | Seventh Floor |
| 40 | Eighth Floor |
| 41 | Ninth Floor |
| 42 | Tenth Floor |
| 43 | Terrace Floor |
| 44 | R.C.C Lintel -Stilt Floor |
| 45 | First floor |
| 46 | Second floor |
| 47 | Third Floor |
| 48 | Fourth Floor |
| 49 | Fifth Floor |
| 50 | Sixth Floor |
| 51 | Seventh Floor |
| 52 | Eighth Floor |
| 53 | Ninth Floor |
| 54 | Tenth Floor |
| 55 | Terrace floor |
| 56 | R.C.C Chajja-First floor |
| 57 | Second floor |
| 58 | Third Floor |
| 59 | Fourth Floor |
| 60 | Fifth Floor |
| 61 | Sixth Floor |
| 62 | Seventh Floor |
| 63 | Eighth Floor |
| 64 | Ninth Floor |
| 65 | Tenth Floor |
| 66 | R.C.C Roof Beam -Stilt Floor |
| 67 | First floor |
| 68 | Second floor |
| 69 | Third Floor |
| 70 | Fourth Floor |
| 71 | Fifth Floor |
| 72 | Sixth Floor |
| 73 | Seventh Floor |
| 74 | Eighth Floor |
| 75 | Ninth Floor |
| 76 | Tenth Floor |
| 77 | Terrace floor |
| 78 | R.C.C Slab -Stilt Floor |
| 79 | First floor |
| 80 | Second floor |
| 81 | Third Floor |
| 82 | Fourth Floor |
| 83 | Fifth Floor |
| 84 | Sixth Floor |
| 85 | Seventh Floor |
| 86 | Eighth Floor |
| 87 | Ninth Floor |
| 88 | Tenth Floor |
| 89 | Terrace floor |
| 90 | R.C.C Stair case -Stilt Floor |
| 91 | First floor |
| 92 | Second floor |
| 93 | Third Floor |
| 94 | Fourth Floor |
| 95 | Fifth Floor |
| 96 | Sixth Floor |
| 97 | Seventh Floor |
| 98 | Eighth Floor |
| 99 | Ninth Floor |
| 100 | Tenth Floor |
| 101 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.Stilt Floor |
| 102 | First floor |
| 103 | Second floor |
| 104 | Third Floor |
| 105 | Fourth Floor |
| 106 | Fifth Floor |
| 107 | Sixth Floor |
| 108 | Seventh Floor |
| 109 | Eighth Floor |
| 110 | Ninth Floor |
| 111 | Tenth Floor |
| 112 | Terrace floor |
| 113 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(Out side). Stilt Floor |
| 114 | First floor |
| 115 | Second floor |
| 116 | Third Floor |
| 117 | Fourth Floor |
| 118 | Fifth Floor |
| 119 | Sixth Floor |
| 120 | Seventh Floor |
| 121 | Eighth Floor |
| 122 | Ninth Floor |
| 123 | Tenth Floor |
| 124 | Terrace floor |
| 125 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(In side). Stilt Floor |
| 126 | First floor |
| 127 | Second floor |
| 128 | Third Floor |
| 129 | Fourth Floor |
| 130 | Fifth Floor |
| 131 | Sixth Floor |
| 132 | Seventh Floor |
| 133 | Eighth Floor |
| 134 | Ninth Floor |
| 135 | Tenth Floor |
| 136 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Stilt Floor |
| 137 | First floor |
| 138 | Second floor |
| 139 | Third Floor |
| 140 | Fourth Floor |
| 141 | Fifth Floor |
| 142 | Sixth Floor |
| 143 | Seventh Floor |
| 144 | Eighth Floor |
| 145 | Ninth Floor |
| 146 | Tenth Floor |
| 147 | Terrace floor |
| 148 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge. Stilt Floor |
| 149 | First floor |
| 150 | Second floor |
| 151 | Third Floor |
| 152 | Fourth Floor |
| 153 | Fifth Floor |
| 154 | Sixth Floor |
| 155 | Seventh Floor |
| 156 | Eighth Floor |
| 157 | Ninth Floor |
| 158 | Tenth Floor |
| 159 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge. Stilt Floor |
| 160 | First floor |
| 161 | Second floor |
| 162 | Third Floor |
| 163 | Fourth Floor |
| 164 | Fifth Floor |
| 165 | Sixth Floor |
| 166 | Seventh Floor |
| 167 | Eighth Floor |
| 168 | Ninth Floor |
| 169 | Tenth Floor |
| 170 | Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 8-10mm conforming to IS 13755 of 600x600 (homogeneous) of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.First floor |
| 171 | Second floor |
| 172 | Third Floor |
| 173 | Fourth Floor |
| 174 | Fifth Floor |
| 175 | Sixth Floor |
| 176 | Seventh Floor |
| 177 | Eighth Floor |
| 178 | Ninth Floor |
| 179 | Tenth Floor |
| 180 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of size 600mm x 600mm (homogeneous) of premium quality) of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects. First floor. |
| 181 | Second floor |
| 182 | Third Floor |
| 183 | Fourth Floor |
| 184 | Fifth Floor |
| 185 | Sixth Floor |
| 186 | Seventh Floor |
| 187 | Eighth Floor |
| 188 | Ninth Floor |
| 189 | Tenth Floor |
| 190 | 25 mm. average thick artificial stone flooring with cement punning laid to proper slope with cement concrete of proportion (1:2:4) using screened and washed sharp sand for mortar with black hard crusher broken granite stone chips of approved quality and from approved quarry, washed and cleaned laid in two layers i.e. the bottom layer being 19 mm . thick and top layer of 6mm. thick with 12mm. to 20. size black hard crusher broken stone chips (20mm size chips not to exceed 25%) including chipping and chiseling and cleaning the top surface of the floor slabs in upper floors, including rounding of corners, watering and curing with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge. Stilt Floor |
| 191 | Providing & Fixinng factory made 100% Solid WPC ( Wood Polymer Composite )- Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (Make- Rajashree, Alstone,century,Terra plast) First floor. |
| 192 | Second floor |
| 193 | Third Floor |
| 194 | Fourth Floor |
| 195 | Fifth Floor |
| 196 | Sixth Floor |
| 197 | Seventh Floor |
| 198 | Eighth Floor |
| 199 | Ninth Floor |
| 200 | Tenth Floor |
| 201 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.First floor |
| 202 | Second floor |
| 203 | Third Floor |
| 204 | Fourth Floor |
| 205 | Fifth Floor |
| 206 | Sixth Floor |
| 207 | Seventh Floor |
| 208 | Eighth Floor |
| 209 | Ninth Floor |
| 210 | Tenth Floor |
| 211 | Providing and fixing ISI Marked un-insulated fire rated door confirming to IS 3614:2021,& tested to IS17518,and shall carry a unique label with certification/test report number.The fire rating shall be for 120minutes integrity only.Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2(18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm/sqm).Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers.The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement. |
| 212 | All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of double leaf doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS-304 grade of size100x75x3mm,1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back to back per leaf, with spindle,SS 304, SS finish. 1no of Door closer with spring size of EN 2- 4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Shakti Hormannm,Tata pravesh). Stilt Floor |
| 213 | First floor |
| 214 | Second floor |
| 215 | Third Floor |
| 216 | Fourth Floor |
| 217 | Fifth Floor |
| 218 | Sixth Floor |
| 219 | Seventh Floor |
| 220 | Eighth Floor |
| 221 | Ninth Floor |
| 222 | Tenth Floor |
| 223 | Supplying and fixing of Powder coated 50-60 microns approved colour of Aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass of make-Saint gobain/ AIS/ Gardian/ modi. the rate quoted inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion ,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame - 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter - 34.6 x 26 x 1.5mm thickness, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Jindal, Hindalco, schueco). First floor |
| 224 | Second floor |
| 225 | Third Floor |
| 226 | Fourth Floor |
| 227 | Fifth Floor |
| 228 | Sixth Floor |
| 229 | Seventh Floor |
| 230 | Eighth Floor |
| 231 | Ninth Floor |
| 232 | Tenth Floor |
| 233 | Supplying and installing UPVC- 3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32 mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/AIS/Gardian/modi . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) First floor |
| 234 | Second floor |
| 235 | Third Floor |
| 236 | Fourth Floor |
| 237 | Fifth Floor |
| 238 | Sixth Floor |
| 239 | Seventh Floor |
| 240 | Eighth Floor |
| 241 | Ninth Floor |
| 242 | Tenth Floor |
| 243 | Terrace floor |
| 244 | Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge. Stilt Floor |
| 245 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. First floor |
| 246 | Second floor |
| 247 | Third Floor |
| 248 | Fourth Floor |
| 249 | Fifth Floor |
| 250 | Sixth Floor |
| 251 | Seventh Floor |
| 252 | Eighth Floor |
| 253 | Ninth Floor |
| 254 | Tenth Floor |
| 255 | Terrace floor |
| 256 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Stilt Floor |
| 257 | First floor |
| 258 | Second floor |
| 259 | Third Floor |
| 260 | Fourth Floor |
| 261 | Fifth Floor |
| 262 | Sixth Floor |
| 263 | Seventh Floor |
| 264 | Eighth Floor |
| 265 | Ninth Floor |
| 266 | Tenth Floor |
| 267 | Terrace floor |
| 268 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Stilt Floor |
| 269 | First floor |
| 270 | Second floor |
| 271 | Third Floor |
| 272 | Fourth Floor |
| 273 | Fifth Floor |
| 274 | Sixth Floor |
| 275 | Seventh Floor |
| 276 | Eighth Floor |
| 277 | Ninth Floor |
| 278 | Tenth Floor |
| 279 | Terrace floor |
| 280 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Stilt Floor |
| 281 | First floor |
| 282 | Second floor |
| 283 | Third Floor |
| 284 | Fourth Floor |
| 285 | Fifth Floor |
| 286 | Sixth Floor |
| 287 | Seventh Floor |
| 288 | Eighth Floor |
| 289 | Ninth Floor |
| 290 | Tenth Floor |
| 291 | Terrace floor |
| 292 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Stilt Floor |
| 293 | First floor |
| 294 | Second floor |
| 295 | Third Floor |
| 296 | Fourth Floor |
| 297 | Fifth Floor |
| 298 | Sixth Floor |
| 299 | Seventh Floor |
| 300 | Eighth Floor |
| 301 | Ninth Floor |
| 302 | Tenth Floor |
| 303 | Terrace floor. |
| 304 | Painting two coat with approved synthetic enamel paint to new wood work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). First floor |
| 305 | Second floor |
| 306 | Third Floor |
| 307 | Fourth Floor |
| 308 | Fifth Floor |
| 309 | Sixth Floor |
| 310 | Seventh Floor |
| 311 | Eighth Floor |
| 312 | Ninth Floor |
| 313 | Tenth Floor |
| 314 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). First floor |
| 315 | Second floor |
| 316 | Third Floor |
| 317 | Fourth Floor |
| 318 | Fifth Floor |
| 319 | Sixth Floor |
| 320 | Seventh Floor |
| 321 | Eighth Floor |
| 322 | Ninth Floor |
| 323 | Tenth Floor |
| 324 | Terrace floor |
| 325 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL). Stilt Floor |
| 326 | First floor |
| 327 | Second floor |
| 328 | Third Floor |
| 329 | Fourth Floor |
| 330 | Fifth Floor |
| 331 | Sixth Floor |
| 332 | Seventh Floor |
| 333 | Eighth Floor |
| 334 | Ninth Floor |
| 335 | Tenth Floor |
| 336 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. Tenth Floor |
| 337 | Terrace floor |
| 338 | Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30% Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² @ 28dTensile elongation: 60% @ 20°CShore A Hardness >85 (between 3 - 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)(Make-Myk, Fosroc, Sika). Tenth Floor |
| 339 | Terrace floor |
| 340 | E.I. WORKSub-Head I (modular Wiring Items)-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.N.B: 2way switch shall be used for living room for controlling room light and fan adjacent to bed.Each lightpoint should have provision for ceiling rose and angle holder point. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter.There shall be separate switchboard for inverter points and raw points. |
| 341 | GROUP-A(QTRS) |
| 342 | GROUP-B(QTRS) |
| 343 | GROUP-C(COMMON ARAE) |
| 344 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 345 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 346 | Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 347 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 348 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 349 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 350 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)(15A PLUG,AC,COMMON LIGHT DB AT FLOOR) |
| 351 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 352 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 16 sq. mm copper wire for phase and neutral and 01 nos of single core 10 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(BDB TO FLOOR PANEL TO TPN BDB power) (2X16+1X10) |
| 353 | Supplying and fixing of following sizes of heavy class FRLS PVC conduit (Make-AKG/Polycab/precision/norpack/sudhakar) along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .(For TV/Internet cable /Fire detection only) |
| 354 | 20 MM |
| 355 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 356 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 357 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge . |
| 358 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 359 | Sub-Head II (Light fitting Fixture & Fan) |
| 360 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 361 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 362 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 363 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.(Make: Panasonic/ LT/ Havells /Philips/ Wipro / Crompton/ Bajaj) The luminaire should be Replacement Warranty will be 2 years |
| 364 | Supply and fixing of 10 Watt LED BH Fitting (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro) |
| 365 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 366 | Supplying, Erection, Fixing, connection & testing of LED street light with moveableG.I bracket & G.I Flat clamp ,90 W LED having die cast aluminium housing with toughened glass having lumen efficacy of 120 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 66 protection or more , LED street light .make-wipro/philips/Havells/Bajaj/panasonic /LT/Crompton. The luminaire should be supplied along with bracket maintenance free for inspection as required,wired by 1.5 sq. mm FRLS wire /cable along with earth wire as per direction of Engg.-in-Charge. |
| 367 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.To be used for corridor, lobby, and parking area |
| 368 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 369 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 370 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years .(INVERTER DB FOR ALL THE QTRS,STLIT) |
| 371 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (For STILT FLOOR,FLOOR COMMON, corridor DB OF FLAT) |
| 372 | Supply and fixing of 2 Way As per IEC 61439-3, 2 row of 14 M MCB DD DB Completly flexible to organise the distribution as per site requirements Improved Pan assembly for ease of installation Prefitted masking sheet Reversible door for IP 43 Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door (RAW DB FOR ALL THE QTRS)Warranty on DB is 3 years |
| 373 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years. |
| 374 | Supplying and fixing 16 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year |
| 375 | Supplying and fixing 16 Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 376 | Supplying and fixing 63 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year |
| 377 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 378 | Supplying and fixing of Type II 1P+N SPD with maximum discharge current Imax(8/20) msec-20kA, in the incommer of Distribution board, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB-SB200 in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 year. |
| 379 | (Earthing) INSTALLATION |
| 380 | S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 381 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 382 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 383 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL) |
| 384 | Supply and fixing of 600mm(Length)x100mm(Breadth) x10mm(thickness) Al earth busbar/equipotential bonding bar with drum insulator and nut bolt as per the connection to be provied in each floor and main LT panel in complete as per the direction of Engineer-in-charge. |
| 385 | CABLING AND END TERMINATION MAIN AREA |
| 386 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE Property AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. make-polycab/finolex/Havells/RR Kabel/KEI/Gloster |
| 387 | 3.5core x 240 sq mm ( TO MAIN PANEL )(03 run) |
| 388 | 3.5core x 95 sq mm (DG) 2 runs,SERVICE PANEL |
| 389 | 4core x 16 sq mm (LIFT,SERVICES,light common panel) |
| 390 | 3.5core x 150 sq mm(metering panel ) |
| 391 | 3.5core x50 sq mm(main common panel ) |
| 392 | LAYING OF CABLE |
| 393 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 394 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 395 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 396 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 397 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 398 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 399 | 3.5 core x240 sq mm |
| 400 | 3.5 core x95 sq mm |
| 401 | 4core x 16 sq mm |
| 402 | 3.5core x 150 sq mm |
| 403 | 3.5core x 50 sq mm |
| 404 | Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 405 | 50 mm dia |
| 406 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 407 | 200 mm dia |
| 408 | PANELS |
| 409 | MAIN METERING PANEL EACH 20 NOS FLAT |
| 410 | S/I/T&Commissioning of LT indoor floor mounted cubical type METERING electrical main panel (for QTR) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. 50x10mm Separate Aluminium Earth bus bar is to be provided. Mandatory provision of cable alley is to be given.In commer- 01 number of 400 Amps 4P MCCB Icu=100%Ics,,36KA LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) with 400A 4P changeover switch (Make-ABB/ Siemens/ Schneider/ Legrand).Busbar- 04 numbers of 500Amps ALUMINUM busbar with 1A/SQ.MM current carring capacity.Busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB (Make-LEGRAND-dx3/ Siemens-betaguard/ Schneider-acti 9/ABB SB 200) 22 nos with space for 22 nos 10-100A 1PH KWH Meter digital type for each quarter.Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication .(iii)1 SET. 3P+N 40kA type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. |
| 411 | MAIN CONTROL PANEL |
| 412 | S/I/T&Commissioning of LT indoor/Outdoor floor mounted cubical type METERING electrical main panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. 80x10mm Separate Aluminium Earth bus bar is to be provided. Mandatory provision of cable alley is to be given.ON/OFF/TRIP indication of all the feeders are to be given.In commer- 01 number of 800 Amps 4P MCCB Icu=100%Ics,,36KA LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula).Busbar- 04 numbers of 900Amps ALUMINUM busbar with 1A/SQ.MM current carring capacity.Busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).NON EMERGENCY FEEDEROut going- (i)02 number of 400 Amps 4P MCCB Icu=100%Ics,,36KA LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula).EMERGENCY FEEDER01 number of 400 Amps 4P MCCB Icu=100%Ics,,36KA LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) with 400A 4P changeover switch (Make-ABB/ Siemens/ Schneider/ Legrand).(for main & dg).Out going- 01 number of 200 Amps 4P MCCB Icu=100%Ics,,25KA MCCB with TM based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) For fire fighting. |
| 413 | Out going- 01 number of 160 Amps 4P MCCB Icu=100%Ics,,25KA MCCB withTM based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) For LIFT & WATER SUPPLY PANEL.Out going- 03 number of 63 Amps 4P MCCB Icu=100%Ics,,25KA MCCB withTM based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) For FIREMANS LIFT, LIFT WELL AND LIFT LOBBY PRESSURIZATION.Out going- 04 number of 100 Amps 4P MCCB Icu=100%Ics,,25KA MCCB withTM based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula).Out going- 01 number of 40 Amps 4P MCCB Icu=100%Ics,,16KA MCCB withTM based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) For COMMON LIGHT PANEL.Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication .All the outgoing feeders shall have digital ammeter with suitable rating of class 1 CT.(iii)2 SET. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. |
| 414 | SUB PANEL FOR LIFT ,WATER SUPPLY EMERGENCY |
| 415 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 2 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Out going- 4 numbers of 6-32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Out going- 4 numbers of 63A 4P MCCB16KA, TMR , Ics=100%Icu ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) LIFT 2 NOS ,WATER.Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 416 | (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 417 | EMERGENCY LIGHT PANEL |
| 418 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 100A 4P changeover switch (Make-ABB/Siemens/Schneider/Legrand).(for 12KW SOLAR & dg).Busbar-1&2 04 numbers of 150Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 13 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) (FOR FLOOR COMMON LIGHT DB).Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication. |
| 419 | LIFT PANEL |
| 420 | SITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD(3P+N) 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100%Ics as incommer, 100 amp electrolyte cu bus ba-1 Set, 63A Amp 4P RCCB 30mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel) |
| 421 | CABLE TRAY |
| 422 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 423 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 600mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 424 | 15 PASSENGER-cum-stretcher-cum-goods LIFT WITH WIRRING(1.1) To be used as fireman's lift |
| 425 | Supply,Installation, Testing & Commissioning of of 15 Passenger-cum-stretcher-goods lift with side opening gearless with Machine room Capacity,Elevator S+10 Floors (Shaft size should not be less than-1800mm(Left to right)x3000mm(Front to back)) (Min. Car size-1000mm(Left to right)x2400mm(Front to back), car height 2500mm) with ACVVVF drive/Control for constant load of 1020 kg ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS materials shall be of grade SS-304 with thickness not less than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons (v) provision of flat cat 6 cable for cctv with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Johnson/Schindler |
| 426 | 10 PASSENGER LIFT WITH WIRRING(1.1) |
| 427 | Supply,Installation, Testing & Commissioning of of 10 Passenger lift gearless with Machine room Capacity,Elevator S+10 Floors (Shaft size should not be less than-1900mm(Left to right)x2150mm(Front to back)) with ACVVVF drive/Control for constant load of 680 kg ARD 1.25 MPS SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS materials shall be of grade SS-304 with thickness not less than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons (v) provision of flat cat 6 cable for cctv with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Johnson/Schindler |
| 428 | Street light |
| 429 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 430 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 431 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 432 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 433 | Supplying, Erection, Fixing, connection & testing of 100W FLOOD Light(120LM/W) of Panasonic/LT/Havells / Philips/ Wipro / Crompton/ Bajaj) maintenance free having 5 years warranty wit including MCB,stainless steel braket along with driver & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 434 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make- POLYCAB/ KEI/ HAVELLS/ Gloster/ Finolex/ RR Kabel |
| 435 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 436 | FIRE FIGHTING |
| 437 | PUMPS AND APPURTENANCES Please Enable Macros to View BoQ information |
| 438 | PUMPS AND APPURTENANCES Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail