| Sl. No. | Item Description |
| 1 | PART-I (Civil works) Earth work in excavation of foundation in hard soil or gravelly soil within 50 m initial loead and initieal lift, including dressing and levelling the bed etc. complete |
| 2 | Supplying and filling foundation and plinth with sand wall watered and rammed with cost conveyance and royality, taxes of all materials and labour (T&P) etc. complete. |
| 3 | Cement Concrete (1:3:6) in Foundation using 4 cm size bhg metal including watering, curing with cost, conveyance, royalty and taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 4 | R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge.For Column Base |
| 5 | Plinth Beam |
| 6 | Column / Beam |
| 7 | Lintel |
| 8 | Chajja |
| 9 | R.C.C. at Window Sill Level |
| 10 | R.C.C. Shelves |
| 11 | Staircase |
| 12 | Roof Slab |
| 13 | Column / Beam (First Floor) |
| 14 | Lintel (First Floor) |
| 15 | Chajja (First Floor) |
| 16 | R.C.C. at Window Sill Level (First Floor) |
| 17 | R.C.C. Shelves (First Floor) |
| 18 | Staircase (First Floor) |
| 19 | Roof Slab (First Floor) |
| 20 | Column / Beam (Head Room) |
| 21 | Roof Slab (Head Room) |
| 22 | Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 23 | Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. (First Floor) |
| 24 | Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. (Head Room) |
| 25 | 25mm thick Grading Concrete (1:2:2) using 4.7mm size b.h.g. chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 26 | 25mm thick Grading Concrete (1:2:2) using 4.7mm size b.h.g. chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge.(First Floor) |
| 27 | 25mm thick Grading Concrete (1:2:2) using 4.7mm size b.h.g. chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. (Head Room) |
| 28 | Fly Ash Brick masonry with CM (1:6) in Foundation & Plinth including watering, curing with cost, conveyance, royalty and taxes of all materials & labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 29 | Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. |
| 30 | Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge.(First Floor) |
| 31 | Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge.(Head Room) |
| 32 | 16 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 33 | 16 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge..(First Floor) |
| 34 | 16 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(Head Room) |
| 35 | 12mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 36 | 12mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge..(First Floor) |
| 37 | 12mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(Head Room) |
| 38 | 6mm thick C.P. (1:4) as ceiling plaster including watering, curing, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 39 | 6mm thick C.P. (1:4) as ceiling plaster including watering, curing, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(First Floor) |
| 40 | 6mm thick C.P. (1:4) as ceiling plaster including watering, curing, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.((Head Room) |
| 41 | Supplying, fitting, fixing of Vetrified tile flooring on 20mm thick bed of C.M. (1:4) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 42 | Supplying, fitting, fixing of Vetrified tile flooring on 20mm thick bed of C.M. (1:4) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(First Floor) |
| 43 | Supplying, fitting, fixing of Vetrified tile in dados on 12mm thick C.P. (1:3) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 44 | Supplying, fitting, fixing of Vetrified tile in dados on 12mm thick C.P. (1:3) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(First Floor) |
| 45 | Supplying, fitting, fixing of Ceramic Glazed Wall tile in walls on 12mm thick C.P. (1:3) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(Ground Floor) |
| 46 | Supplying, fitting, fixing of Granite tile on 20mm thick bed of C.M. (1:4) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(Ground Floor) |
| 47 | Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete.GF,FF & HR |
| 48 | Labour for fitting, fixing of M.S. Door / Window shutters, grill gates etc. including cost of all labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.GF,FF & HR |
| 49 | Supplying, fitting, fixing of WPC Door Frames with Rebate Cuts and Finished cross section size 75mmx45mm or 90mm x 50mm including cost, conveyance of all materials and labour etc. complete as per the direction of Engineer-in-Charge. |
| 50 | Supplying, fitting, fixing of WPC Door Frames with Rebate Cuts and Finished cross section size 75mmx45mm or 90mm x 50mm including cost, conveyance of all materials and labour etc. complete as per the direction of Engineer-in-Charge.(First Floor) |
| 51 | Supplying, fitting, fixing of WPC Door Frames with Rebate Cuts and Finished cross section size 75mmx45mm or 90mm x 50mm including cost, conveyance of all materials and labour etc. complete as per the direction of Engineer-in-Charge.(Head Room) |
| 52 | Providing and fixing of 30mm thick Flush Door Shutters conforming to IS:2002 (Part-I) decorative type, core of block board construction with frame of 1st class hard wood and and well matched teak 3 ply veneering with vertical grains or cross bands and face vineers on both face of shutters inclusive of 4 Nos. of Stainless steel Butt Hinges (100mm x 60mm x 2.5mm) 40mm stainless steel screws, Cylindrical Lock (Godrej-9843), Tower Bolt SS 10 x 300mm (Bathroom) (Godrej 3264), PVC Door Buffer with SS Screw, teak wood lipping around the edges & paste with 1.5mm thick laminate on both side of the flush door, etc. including cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc. complete as per the direction of Engineer-in-Charge. |
| 53 | Providing and fixing of 30mm thick Flush Door Shutters conforming to IS:2002 (Part-I) decorative type, core of block board construction with frame of 1st class hard wood and and well matched teak 3 ply veneering with vertical grains or cross bands and face vineers on both face of shutters inclusive of 4 Nos. of Stainless steel Butt Hinges (100mm x 60mm x 2.5mm) 40mm stainless steel screws, Cylindrical Lock (Godrej-9843), Tower Bolt SS 10 x 300mm (Bathroom) (Godrej 3264), PVC Door Buffer with SS Screw, teak wood lipping around the edges & paste with 1.5mm thick laminate on both side of the flush door, etc. including cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc. complete as per the direction of Engineer-in-Charge.(First Floor) |
| 54 | Supplying, fitting, fixing up window/Door (sliding type) made up aluminum Section 151-154,151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc.complete as per direction of Engineer-in charge.(GF & FF) |
| 55 | Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD.) Ventilator / Top Hung - 60 - Series duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessiries, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards.(GF & FF & Head Room) |
| 56 | Structural Steel work riveted, bolted or welded in built-up section, trusses and framed work including cutting, hoisting fixing in position and applying a primer coat of approved steel primer etc. complete.(GF & FF) |
| 57 | Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 58 | Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.(First Floor) |
| 59 | Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.(Head Room) |
| 60 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. |
| 61 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. (First Floor) |
| 62 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. (Head Room) |
| 63 | Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 64 | Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. (First Floor) |
| 65 | Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. (Head Room) |
| 66 | Painting two coats to doors & windows etc. with any approved paints including cost, conveyace of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 67 | Painting two coats to doors & windows etc. with any approved paints including cost, conveyace of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.(First Floor) |
| 68 | Painting two coats to doors & windows etc. with any approved paints including cost, conveyace of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.(Head Room) |
| 69 | Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect.(GF & FF) |
| 70 | Filling foundation & plinth with excavated earth including cost of labour, T&P etc. complete. |
| 71 | Earth work in hard soil Filling in perepherial of building in intial lead 50 mtr and lift including rough dressing and levelling the bed etc complete |
| 72 | Construction of granular sub-base by providing Grading-VI material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 |
| 73 | Providing & laying 60mm thick factory made cement concrete interlocking paver block of M-35 grade made by block makine machine with strong vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 74 | Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 75 | Painting two coats over to steel surface including cost of paint and primer with cost, conveyance, taxes of all materials and labour (T&P) etc. complete. |
| 76 | PART-II (Electrical works)Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR LS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire = Finollex / L & T/ Anchor/ Havels/ V-Guard/ Greatwhite / Polycab) Group A (1.1.1) |
| 77 | -do- .... Group B (1.1.2) |
| 78 | -do- .... Group C (1.1.3) |
| 79 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required.2 Modular box with base & cover (1.24.2) |
| 80 | 4 Modular box with base & cover (1.24.3) |
| 81 | 6 Modular box with base & cover (1.24.4) |
| 82 | 8 Modular box with base & cover (1.24.5) |
| 83 | 12 Modular box with base & cover (1.24.6) |
| 84 | S/F of TV anteena socket outlet on 2 Modular box with base & cover for TV |
| 85 | Supplying and fixing of 20MM PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 86 | S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4) |
| 87 | S/F of 6 Modular GI box in recess with suitable size of Modular base cover in front including providing and fixing 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required.(2X1.25.1+2X1.25.4)+6 MODULE |
| 88 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (1.25.3+1.25.5)+4 MODULE BOX |
| 89 | S/F of computer board (Modular Type) consisting of 3 nos. of 5 amp plug and switch and 6 amp MCB, Indicator complete with wiring on 12 module M.S.box with B.k.cover(1.24.6 + 3 x (1.25.1+ 1.25.4) + 2.6.1)+Indicator |
| 90 | Wiring for circuit I sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS- 694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required ( Make of wire- Finolex/ / Anchor/ Havels/ V-guard / HPL / L&T / Gratewhite / Polycab). -do- 2x1.5sqmm +1x1.5sqmm ( 1.8.1 ) |
| 91 | -do-2x2.5sqmm +1x1.5sqmm ( 1.8.2 ) |
| 92 | -do- 2x4sqmm +1x1.5sqmm ( 1.8.3 ) |
| 93 | -do- 4x6sqmm +2x2.5sqmm ( 1.8.10 ) |
| 94 | Supply and fixing of 63A 4P MCCB,Bus bar and indicator including Panel with all connection and accessories. |
| 95 | S/F of 6 way (6+18) TPN MCB DB double door (2.5.6) |
| 96 | S/F of 63A FOUR POLE MCB C Type ( Make - L&T /Equivalent) |
| 97 | S/Fof 'C' series SP MCB of 5A to 32 Amp rating 240Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP)(2.6.1) |
| 98 | S/F of Call bell/ Buzzer ISI marked sutiable for DC/AC single Phase 230 volts complete as required.(1.30) |
| 99 | S/F of batten holder BK angle holder ISI marked including connection etc instead of ceiling rose (Make: Cona / Anchor / Havells / Greatwhite / Preeti / HPL) (1.29-1.28) |
| 100 | Earthing with G.I. earth pipe 3 metre long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.(3.2) |
| 101 | Supply and laying 6 SWG G.I wire in recess for loop earthing as required ( 3.17) |
| 102 | Supply, Installation, Testing and commissioning of 10W bulkhead LED fittings (make:-havells/Equivalent) |
| 103 | S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS) |
| 104 | S/F of electric step ceiling fan regulater in existing switch box including connection with 1.5sqmm FR PVC insulated single core multistrand copper conductor earthing the regulator as required.(1.38) |
| 105 | S/F of Fan hok S'type made of 16mm MS rod as per specificationn |
| 106 | S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells ) |
| 107 | Supply, Installation, testing and commissioning of 20W Mirror Light (Make:-Havells/ Bajaj/philips/Wipro/Eq.) |
| 108 | Supply & fixing of LED Gate Light 7.5W(Make- Havells/JAQUAR/ Bajaj/philips/Wipro/Eq.) with all accessories. |
| 109 | Supply & fixing of 12W ceiling light recessed mount or surface mount(round or square)(Make- Havells/crompton/ polycab or equvalent) all accessories. |
| 110 | S/F of 18-25 watt LED Tube light fitting compoete with all connection.\ including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL) |
| 111 | Supply of instalation, Testing commissioning of 12 Watt. LED bulb (make:- havells/polycab/or equivalent) |
| 112 | S/F of 15A modular socket on 2 Modular Metal box for A.C |
| 113 | S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL) |
| 114 | S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand) |
| 115 | S/F of 1.5 Ton 5 star Inverter type split A.C. M/C with 4 KVA Voltage Stabilizer(130V-300V) (Make - Microtek, V-Guard) and AC stand with all accessories and connections and installation (Make - HITACHI/ Bluestar/ Carrier) |
| 116 | S/F of GYESER .(15Ltrs)(Make:- Bajaj/V Guard/Havells) with all accessories. |
| 117 | S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB) |
| 118 | S/F of 2000 VA Inverter with 2 nos. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous/Exide) |
| 119 | wiring to sub main with 1*1.5 mm2 single core multi strand copper wire for inverter wiring (1x1.5mm) |
| 120 | Supply of 3.5core 25sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable) |
| 121 | Laying of 3.5core 25sqmm cable on surface |
| 122 | Supplying and making end termination with brass compression gland and aluminum lugs for 3.5CORE 25SQMM cable |
| 123 | Supply and installation of 7 mtr long hot dip galvanized Octagonal pole having base dia of 175 mm and top dia of 70 mm and plate thickness of 4 mm or more complete with base plate of 250x250x16mm and 4 nos. Jtype En 8 grade foundation bolts M24X750mm to withstand 180 KM / HR wind speed considering the weight. Solar lights fixed on the top of the pole for AIO Integrated Solar lights . One no of AIO Solar lights at a height of 7 mtr above ground .Both the Octagonal pole, En8 grade fdn bolts and bracket must be manufactured in the Octagonal pole manufacturing company. ( Bracket & En8 grade Fdn bolts manufactured by third party pole supplier/manufacturer shall not be acceptable).The necessary test reports of Octagonal Pole and EN8 grade fdn bolts must be submitted by the manufacturer for acceptance of product/TDS approval prior to start of the work.The pole manufacturer must submit the confirmation regarding 10 years or more design life of the pole.Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with Solar light on that foundation. The work shall be excuted as per the direction of EIC. Installation of Octagonal Poles and fixing of 1 no AIO solar light in the bracket by using suitable machinery adopting all the safety precaurtions as per the direction of EIC. Make : - Utkarsh/RR Ispat/Vakrangee) |
| 124 | Supply,installation,testing and commissioning of 40 W AIO Solar street lights having 100 Wp or more highly efficient Monocrystalline PV module & 12.8 V 42 Ah or more ( Lithium Ferrophosphate (LiFePo4) Battery having BIS ) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), MPPT charge controller having > 92% efficiency & PIR Sensor. The initial lumen output of AIO street light shall be> 6400 lumen or more in CCT 6000K (+/-500K) (Lumen efficacy of 160 lm/w ) as per LM 79 report of NABL lab . The LED chip will be of OSRAM/NISCHIA/CREE/SEOUL Semiconductor only and should be with lenses for effective lighting distribution. The complete system & BMS should be designed to provide 2 days (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 66 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. Warranty on the AIO street lights must be 5 years .The solar lighting company must submit the warranty certificate in the department by mentioning 5 years warranty on complete lighting system against manufacturing defects. Solar lighting company has to repair/replace the lighting system if required against the manufacturing defect till compleiton of warranty period. The Agency/Contractor has to maintain the lighting system till the completion of warranty period by considering the periodical maintenance like panel cleaning in regular interval and rectifying the defect by engaging labour/machinery to make the lighting system operative till warranty period. The agency/contractor must submit declaration for maintaining the system till warranty period .The following test reports/certifications must be submitted for the technical acceptance of the products .1. LM 79 REPORT NABL lab ) , 2. IK 08 (Report of NABL lab ), 3. IP 66 Report of NABL lab (The necessary test reports of NABL lab against the above must be submitted for any wattage of Solar Street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of Solar Lighting Company (Make:Crompton/Havells/Panasonic/Philips/Wipro) |
| 125 | PART-III (P.H works)Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. Initial lift upto 1.5 mtr |
| 126 | Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. From 1.5 mtr to 3.0 mtr depth |
| 127 | Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C. |
| 128 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 129 | Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 130 | Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 131 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 132 | Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 133 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 134 | Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 135 | Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 136 | Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 137 | Supplying all materials, labour, T&P and providing 110mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 138 | Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 139 | Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C. |
| 140 | Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specificat. Ground floor |
| 141 | 1ST FLOOR - |
| 142 | Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of Engineer-in-Charge. Ground floor |
| 143 | 1ST FLOOR - |
| 144 | Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no 4660 and frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board. and as per direction of the Engineer in charge. |
| 145 | Supplying all materials, labour, T&P and cutting holes through brick/stone masonary works including making good the damages in cm (1:4) for taking GI / PVC pipes and making good the damages etc all complete as per P.H specification and direction of the E.I.C. a) Cutting Hole (250 mm thick wall) |
| 146 | Cutting Grooves in wall or floor |
| 147 | Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C (Neycer/Cerra/ Parry ware/ Hindware) |
| 148 | Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest etc all complete as per specification and direction of the E.I.C. a) 580mmx440mm size White Orissa pan (PARRYWARE, CERA, HINDWARE) |
| 149 | European water closet with P trap plain with seat cover |
| 150 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C.-550mmx400mm size wash hand basin . (Cerra/ Parry ware/ Hindware) |
| 151 | Fixing of Pedestrial for W.H.B |
| 152 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C. 610x510x200 mm stainless steel kitchen sink |
| 153 | Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C. (JAQUAR) 15mm dia CP long body bib cock |
| 154 | 15mm dia CP Two way angle/Bib Cock |
| 155 | 15mm dia CP Health Fuccet |
| 156 | 15mm dia CP Angle Stop Cock |
| 157 | 15 mm dia CP Pillar Cock |
| 158 | 15mm dia CP concealed stop cock |
| 159 | a) Fixing of 20mmx450mm long CP towel rail |
| 160 | 25mm dia U-PVC Ball Valve[Metal Ball] |
| 161 | 32mm dia U-PVC Ball Valve[Metal Ball] |
| 162 | 15mm x 225mm long size CP shower arm |
| 163 | CP towel ring |
| 164 | fixing CP soap holder |
| 165 | 15mm dia CP flange |
| 166 | 15 mm C.P Extension piece 50 mm long |
| 167 | 450mmx125mm size plate Acrylic shelf |
| 168 | Fixing of Glass Mirror 600mmx450mm size B.E mirror (fixed type) |
| 169 | Wall hang water closet (OPS-WHT-15951UF) 'P'/'S' trap plain (Jaguar) |
| 170 | Conseal Cistern Chevron |
| 171 | Supplying all materials, labour, T&P and fitting and fixing U-PVC soil waste ventilating pipes of and fittings of the following outside diameter of 4kg/cm2 conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. a) 110mm dia PVC SWR pipe |
| 172 | 110mm dia Plain bend |
| 173 | 110mm U-PVC door bend |
| 174 | 110mm U-PVC door Tee |
| 175 | 110mm dia cowl |
| 176 | 125mm dia CP grating |
| 177 | 110mm dia PVC P trap |
| 178 | 110mm dia PVC SWR plain bend 450 |
| 179 | 110mm PVC SWR plain Tee |
| 180 | 75 mm dia PVC SWR Pipe |
| 181 | 75mm PVC SWR plain bend |
| 182 | 75mm PVC SWR door bend |
| 183 | 110mm dia PVC SWR Nahani trap without Jally |
| 184 | Supplying all materials, labour, T&P and providing and fixing to wall or ceilling and floor PVC pipes conforming to (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing etc all complete as per P.H specification and direction of the E.I.C. a) 20mm dia C-PVC pipe (Internal) |
| 185 | 25mm dia ASTM/PVC pipe (External) |
| 186 | 32mm dia ASTM/PVC pipe (external) |
| 187 | 25mm dia Outer dia C-PVC pipe(Internal) |
| 188 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:1.5:3) mix using 12 mm size H.G chips, foundation concrete (1:3:6) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C. (a).Inside size 250mmx250mm |
| 189 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C Inside size 760mm x 760mm x 460mm |
| 190 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C. Construction of Soak way Pit Construction of Soak way Pit (0.90 m dia x 2.00m Deep) |
| 191 | Construction of Soak way Pit (1.20 m dia x 2.00m Deep) |
| 192 | Supplying all materials, labour, T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches (to slope or level)and jointing with supply of approved solvent cement by non-heat application method C.C (1:3:6) using 40mm size hard granite metal on bed of the trenches and all round concrete encashing with C:C (1:4:8) using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering, ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C. Laying of 100 mm dia S.W Pipe line Haunch top |
| 193 | Supplying all materials, labour, T&P and Fitting and Fixing of PVC water storage tank including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1000 Ltr capacity Sintex tank |
| 194 | Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1000 Ltr capacit |
| 195 | SINKING OF TW Labour for drilling a perfectly vertical bore hole at specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination rigs as required to suit the site condition as per the direction of the Engineer-in-charge including use of own rigs with its accessories, tools and plants and consumables etc for lowering of 200 mm dia P.V.C/G.I/MS pipes for housing fitted socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/P.V.C/M.S casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tubewell) Drilling of 125mm dia bore- |
| 196 | Drilling of 100mmdia bore- 100 Mtr to 150 Mtr |
| 197 | Lowering of the following size G.I/P.V.C pipes with or without slotted pipes as per the necessary from ground level upto 30 mtrs depth and fitted and fixed up in perfectly vertical position including cutting and threading pipes and slotted pipe and supplying and fixing all jointing materials, tools and plants complete and keeping the top of the casing pipe threaded including plugging tubewell to prevent entry of foreign materials from above. a) Lowering of 125mm dia PVC pipe (Labour) |
| 198 | Cost of 125mm dia PVC pipe (Sch-80-ISI mark) |
| 199 | Cleaning and developing the tube well using their own compressor continuously worked till clean and adequate discharge is obtained from the tubewell including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge. |
| 200 | Installation of pump setSupply of ISI mark 1.00 HP single phase vertical submersible pump set with discharge of 1800-2200 ltr/hour and a head of 45-60 Mtr of reputed make like KSB/TEXMO and equivlant including all cost conveyance and taxes etc all complete as per the direction of E.I.C. |
| 201 | Supplying all labour, T&P and fitting abnd fixing of 1.00 HP single phase vertical submersible pump set with commissioning and testing etc all complete as per the direction of E.I.C. |
| 202 | Supplying all labour, T&P and fitting abnd fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00 HP single phase submersible pump including all cost, conveyance of all taxes etc all complete as per the direction of E.I.C. |
| 203 | Supplying all labour, T&P and fitting abnd fixing of three core flat cable (1.5 mm2) of ISI mark of reputed make like BCH/Finolex or equivalent and connecting the pump and starter including all cost, conveyance and taxes etc all complete as per as per the direction of E.I.C. |
| 204 | Supplying all labour, T&P and fitting abnd fixing of plastic rope MS well cover, MS clamp, stainless steel short piece, bend and socket including all cost, taxes etc all complete as per as per the direction of E.I.C. |
| 205 | Supplying all labour, T&P and fitting abnd fixing of HDPE pipe and fitting with making connection to pump set including all cost, taxes etc all complete as per as per the direction of E.I.C. A) 25mm dia HDPE pipe |
| 206 | BORE PROTECTION Supplying all materials, labour, T&P for construction of bore protection wall with providing sand filling, cement concrete (1:4:8) with HG metal & KB brick work in cement mortar (1:6) of 1.15 height, 16mm thick CP over the brick work, RCC slab of size 0.95 x 0.95 x 0.75 mtr avairage length in C 1:1.5:3, centering shutering including watering curing conveyance of all materials to work site with all cost, taxes etc all complete as per as per the direction of E.I.C. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail