| 1 | Removing old loose bottom or side cover of RCC slab beam columns etc. rubbing surface of concrete steel using wire brush and applying 2 coats of Alkaline rust converting primer (Feovert) after a waiting time of 6 hrs between coats and then applying another anti corrosive protective coating system ) for reinforcement bars (IPNet-RB) Conforms to IS-2770 Part-1 (Pull out Test) ASTM-3963-86 (Adhesion Test) and then applying concrete penetrating corrosion inhibitor (EPCO-KP100) and applying bonding new to old concrete (Epibond) Conforms to ASTM-C-882-87 and plastering on the fresh bond coat with Polymer Modified Mortar (Monobond) with 20mm C.M 1:3 and finishing coat of 6mm C.P 1:3 (1 Cement : 3 Sand ) incl. cost of transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent. |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mts. lead. |
| 3 | 20mm cement plaster 1: 4 (1 cement : 4 fine sand) |
| 4 | Removing white or colour wash by scrapping sand papering and preparing surface smooth including necessary repairs to scratches etc. complete. |
| 5 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. |
| 6 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 7 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 8 | Wall painting (one or more coats) with plastic emulsion paint of approved brand and manufacture on old work to give an even shade. |
| 9 | Painting one or more coats of acryllic exterior paint of approved brand and manufacture(Such as Dulex/ Asian Paints/ Sherwin Willians) on old work including cleaning the surface with water etc. complete. |
| 10 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 11 | Painting one or more coats with superior quality ready mixed paint of steel work of approved brand & manufacture in all shades on old work to give an even shade. |
| 12 | Painting one or more coats with superior quality ready mixed paint of wood work of approved brand & manufacture in all shades on old work to give an even shade. |
| 13 | Cleaning of interlocking pavers by pressure washing |
| 14 | Drycleaning of door/ window curtains |
| 15 | Supply of labour |
| 16 | Supply and installation of Prestige Schott Glass Top gas stove with 3 burner |
| 17 | Providing one-time deep cleaning of entire building/premises including floors, walls, ceilings, doors, windows, grills, glass surfaces, toilets, wash basins, kitchen areas, utility spaces, and furniture (where applicable) using approved cleaning agents, disinfectants, mechanized equipment (scrubbers, vacuum cleaners, etc.) and skilled labour, complete in all respects as per the direction of Engineer-in-Charge. |
| 18 | Providing and making King Size Bed with headboard and storage, made from 30mm thick marine blockboard for the bed frame, headboard, and front panel finished with 4mm thick decorative veneer on visible surfaces, storage compartment provided below the bed with lift-up or hinged shutter including nut bolts, hinges and hydraulic fittings all complete as directed by EIC. |
| 19 | Supply of Poppy double bed Mattress 72x78x6, Sleep grad Foam + HR Foam Covered with quilted Fabric ,foam With Quilted Mattress Both Side |
| 20 | Supplying king size bedsheet with pillow cover |
| 21 | Providing and fixing in position 2mm thick one side embossed clear polycarbonate sheet in same profile to match the roofing sheets including self tapping screws. |
| 22 | Removing and refixing of door/ window shutters paneled or paneled and glazed including replacing of existing hionges chiseling etc complete as directed by Engineer - in - charge, Above 1 Sq.m area |
| 23 | Providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section.;Plain glass Please Enable Macros to View BoQ information |