| 1 | Supplying, installation, testing & commisioning of following capacity Plug In/Plug off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as required intier carriag of material in all leads,lifts, hight and cost of all other incidentals. Make:- Havells/ Legrand/ Helonix/ L & T. |
| 2 | 400 A |
| 3 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required intier carriag of material in all leads,lifts, hight and cost of all other incidentals.Make:- Havells/ Legrand/ Helonix/ L & T. |
| 4 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)intier carriag of material in all leads,lifts, hight and cost of all other incidentals. Make:- Havells/ Legrand/ Helonix/ L & T. |
| 5 | 16 Way, double door |
| 6 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Make:- Havells/ Legrand/ Helonix/ L & T. |
| 7 | 8 way (4+24), double door |
| 8 | Providing and fixing following rating and breaking capacity & Pole with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make:- Havells/ Legrand/ Helonix/ L & T. |
| 9 | 400 A, 50 KA, FP MCCB |
| 10 | 250 A ,50 KA, FP MCCB |
| 11 | 125 A, 36 KA, FP MCCB |
| 12 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required intier carriag of material in all leads,lifts, hight and cost of all other incidentals. Make:- Havells/ Legrand/ Helonix/ L & T. |
| 13 | 100 A |
| 14 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required intier carriag of material in all leads,lifts, hight and cost of all other incidentals.Make:- Havells/ Legrand/ Helonix/ L & T. |
| 15 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required intier carriag of material in all leads,lifts, hight and cost of all other incidentals. Make:- Havells/ Legrand/ Helonix/ L & T. |
| 16 | Single pole (5 amps to 32 amps) |
| 17 | Providing & fixing Iron Platefrom near electrical sub distribution panel intier carriag of material in all leads,lifts, hight and cost of all other incidentals. Please Enable Macros to View BoQ information |