| 1 | Dismentalling of PCC ( Unreinforced) concrete of any description and in any position otherwise specifically provided for and disposal off debries where directed complete all as specified and directed. |
| 2 | Pumping Out Water from the Static Water tank of any capacity and removal of water and mud from the base of SWT including solid material etc upto 50 m distence complete all as specified and directed. |
| 3 | Use and Waste of Formwork to circular on Plan with rough finished surfaces of concrete complete all as specified and directed. |
| 4 | M & L 10 mm dia and over mild steel TMT bars cut to length bent to shape required including cranking, bending binding with MS wire not less than 0.9 mm dia complete all as specified and directed. |
| 5 | M & L for RCC M-30 design mix (20mm graded aggregate) in walls, retaining walls and the like ; any thickness ; above top of footing ; including attached plasters and butresses complete all as specified and directed |
| 6 | M/L for RCC M-30 design-mix (20mm graded aggregate) in beams etc complete all as specified and directed. |
| 7 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and any other treatment like tarfelt etc., complete all as specified and directed. |
| 8 | M&L 10 mm thick cement plaster in CM 1:4 mixed with WPC as per manufacturers instructions finished even and smooth without using extra cement on fair faces of beams, columns, walls etc., complete all as specified and directed.(Note : WPC shall be measured and paid for separately under relevant item as supplying only). |
| 9 | Supply only water prooofing material as per manufactures's instruction complete all as specified and directed. |
| 10 | M&L for two coats of cment base paint on new plastered wall surfaces after applying a coat of alkili resistent primer including preparation of surfaces complete all as specified and directed. |
| 11 | M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggreegate as in foundations filling , sub base and mass concrete finishing the surface even and rough and including demolition of exsiting PCC and removing the debries not exceeding 50 mtr etc complete all as specified and directed. |
| 12 | 100MM thick Plain Cement Concrete 1:2:4 type B-2(using 40mm graded stone aggregate)as in hardstanding , plinth including finishing the surface even and smooth without using extra cement including demolition of exsiting PCC and removing the debries not exceeding 50 mtr etc complete all as specified and directed. |
| 13 | M&L Brick work with burnt clay bricks in cement mortar 1:6 , with subclass 'B' bricks, straight or curved in plan exceeding 6 m mean radius. Incl demolition of old brickwork of any type complete all as specified and directed. |
| 14 | S&F Structural steel, rolled section such as joist, beam, channel, angle, tee,sections independently without connecting plates etc ( Cut to ordinary lenths i.e within 20mm of the length indicated ) conforming to FE290GDE E-165 complete all as specified and directed. |
| 15 | Expended metal n exc 4 kg per Sqm , cut to length , bent to shape required and tying with and including annealed mild steel not less then 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members incl dismantalling of mild steel work of any description incl metal wire fabric of any thickness of mess fixed with steel frame weight n exc 4 kg /Sqm mild steel work etc complete all as specified and dirwected |
| 16 | M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 17 | Excavating in post holes each not exc 0.5 Cum in soft/loose of soil, getting out, returning fillimg in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm thick watering and well ramming and removing surplus soil to a distance n, exc 50m and making good surface complete all as specified and directed |
| 18 | M&L for PCC (1:2:4) type B-2 (40mm graded aggregate) as in foundation and mass concrerte for embedding post complete all as specified and directed |
| 19 | M&L mild steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1978 grade St -240 complete all as specified and directed. |
| 20 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde?E- 250) quality A etc complete all as specified and as directed. |
| 21 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified. etc complete all as specified and as directed. |
| 22 | Material and labour for applying two coats of synthetic enemel paint over and including a coat of red oxide primer on new steel and iron surfaces of any description exceeding 10 cm in width or girth including preparation of surface, complete all as specified and directed. |
| 23 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 24 | Material and labour for hardcore of broken stone of gauge not exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 25 | M&L for cement concrete type D2 ,1:4:8 100mm thick (40mm graded stone aggregate ) as in sub floors , sub bases complete all as specified and directed. |
| 26 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns , drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compavting and proper embedding /laying or inter locking paver blocks into the snad bedding layer through vibratory size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 27 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. Please Enable Macros to View BoQ information |