Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refilling with selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of vegetation, grass, etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 2 | Lead charges for Lead exceeding 1 KM but not exceeding 2 KM, by mechanical transportincluding loading, unloading, stacking / levelling etc. |
| 3 | Labour charges for murum filling under floors of specified thickness in layers of not exceeding 150 mm thickness including consolidation etc.complete all as per drawings and specifications and as directed by the Engineer-in-charge. (using murrum available at BARC campus with a lead of up to 4 Km)Note: a) Only compacted volume will be measured and paid, b) Selected / approved excavated stuff stored within the DAE premises shall be issued free of cost to the contractor for filling purposes. |
| 4 | Supplying, stacking and laying of 230 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, moorum etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge(230mm With outside material). |
| 5 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge.(Excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.) |
| 6 | Extra over item 5 for RCC M60 grade |
| 7 | Extra for RCC Using Ready Mix Concrete including transporting and pumping from approved batching plants |
| 8 | Providing and laying in cement concrete(RCC/PCC) of 1:1.5:3 at all levels (1 cement, 1.5 crushedsand, 3 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curingetc.. complete as per per drawings, specifications and as directed by the Engineer-in-charges but excluding the cost of shuttering, centering and steel reinforcement. |
| 9 | Providing, centering, shuttering Form work using steel plates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels. |
| 10 | Providing and Laying Solid cement concrete block masonry with M-5 Grade of 190/ 140 mm thick in super structure in cement mortar 1:4 (using crushed sand). The rate shall also including scafolding/ staging, drilling of holes (if any) for fixing of rebar by applying chemical or welding or as directed by EIC including Making the cut out opening in masonary for flush concealing DB/plug point/switch box enclosure including dismantling in floor or walls by cutting masonary and making good the damage to walls, painting, etc. existing surface including disposal of rubbish to the naerest dumping ground at a minimum distance of 50m away from the building. Complete all as per drawings and specifications and as directed by the Engineer-in-charge. Note:( Reinforcement will be paid under relevant item) |
| 11 | Providing and fixing TMT Steel Reinforcement bars of specified grades manufactured using virgin materials confirming to IS 1786 for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge(Steel supplied by contractor). |
| 12 | Providing, supplying and fixing hollow metal flush steel doors 40 mm thick consisting of door frame and shutters and all hardware fittings, frame made out of 14g thick G.I sheets and shutters made of 16g thick sheets, hollow portion filled with puff, including necessary stiffeners in shutters and frame, vision panel of specified size with 4 mm glass and clip on pressed steel frame for vision panels, fixing 4 nos heavy duty stainless steel 304 grade ball bearing, fire tested stainless steel butt hinges of size 100 x 75 x 3.00 mm (heavy weight) with suitable stainless steel screws, mortise / dead lock , a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt, etc. framehollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concrete with anchor fasteners. finished with Polyurethane painting of approved colour complete all as perdrawings and specifications and as directed by the Engineer-in-charge |
| 13 | Providing and fixing factory made Single / Double leaf Partially insulated metal fire rated door set of FD 120 Pl classification with 120 minutes integrity and 30 minutes insulation as per lS 3614:2021 consisting of galvanized iron steel frame and Single / Double leaf shutter including necessary hardwareaccessories, conforming to FD 120 Pl classification of lS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick Gl Sheet with minimum 120 GSM Zinc coating as per lS: 277. The entire fire rated door set assembly shall be tested in latched condition as per lS 17518 (Part -l) 2022. The recommended fire doors shall have type test report from NABL certified lab. Proper label confirming the type of door and the hourly rating shall be mandatory. Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self-tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per lS 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonry/concrete wall opening with CSK/Hex/Any other headed fastener of minimum 8 mm dia size and minimum 80mm long with 8mm dia Polyamide sleeves @ 5 numbers at each on vertical sides and 2 numbers on horizontal top side. Door shutter: The double skinned single leaf partially insulated fire rated door shutters shall be consisting of minimum 50 mm thick and having box like structure, slots cut and holes punched, for fixing of hardware’s with stiffeners as per lS: 16074 including resin bonded mineral wool / ceramic wool infill material of minimum density 96 kg/cum. Door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size l3x2 mm to be fixed all around the glass on both the sides/ as per manufacturer arrangement. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaf. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935:2002 or butt hinges as per lS 12817, of minimum size 100x75x3 mm @ 5 numbers hinges up to 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. Hardware Accessories: Mortise / dead lock, a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt / concealed tower bolt etc. One/Two (Single/Double leaf) number heavy duty door closer of size EN 3-5 with standard arm, of desired finish (suitable up to 1250 mm door width) conforming to lS 3564/EN 1154.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per lS:13871 of approved colour and shade all complete as per manufacturer specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled with PCC 1:2:4/ cement grout after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer.Complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 14 | Providing and fixing fire rated Steel Rim Panic Exit Device of approved brand & quality in single leaf door upto 1000mm wide including all accessories etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 15 | Providing and fixing FRP door shutters flush door / panelled type with plain colour or wooden veneer finish, design & colour. made out of 1.5 mm thick FRP skin moulded over wooden frame work of 40 mm wide and required thickness wooden styles and minimum 100 mm wide lock rails and wooden blocks for door stoppers, tower bolts, baby latch, aldrop, handles etc. wherever required and core filled with Polyurethane Foam and fixing with 4 Nos 100 mm (ISI marked) stainless steel hinges with S.S. wood screws 35 mm thick panelled door type of approved colours including the cost of 100 mm ISI marked heavy quality stainless steel butt hinges with necessary screws.complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 16 | Structural Steel Works of MS rolled single / built-up sections conforming to IS 2062 for staircase, edge angles, nosing angles in trench covers, gratings etc., mild steel embedment part for lining supports, sampling blisters, embedded cubicles, SBT line supports, trolleys, MSM EPs, RSW EPs, Electrical Plug EPs, PE door EPs, crane & monorail related EPs, trench pipe supports, various pipe EPs and plate EPs, ACVE related EPs such as duct EP, angle or channel frames for filter banks and closing ducts, supporting arrangement for EPs embedded in concrete, column guards, monorails, railings, handrails, ladders, box column sections, Monorail, built-up sections, crane girders, MS grid work for lining works, crane girders, trolley rails, joists, channels, in M.S Plain Plates and chequered Plates in Trench Covers, gratings, connection plates, supporting arrangement for EPs embedded in concrete etc., including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc.complete all as per specifications, drawings and as directed by the Engineer in charge |
| 17 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing & staircases railing including applying a priming coat of zinc chromate steel primer etc. complete as per specifications using M.S tubes of ISI marked (Medium) of specified diameter and thickness complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 18 | Supplying and fixing Rolling shutters as per ISI standards made out of required size of MS lathes 18 gauge interlocked together throughout entire length and jointed together at the end by end locks mounted on specially designed pipes shaft with brackets, side guides and arrangements for inside & outside locking with push and pull operation complete including the cost of providing and fixing necessary springs of required size and M. S top cover of required thickness for rolling shutters Rolling shutters (Laths Interlocked) gear operated type with handles including top hood 1.25mm mm thick complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 19 | Extra over the cost of rolling shutters for providing and fixing motorized arrangements( withremote & manual operation) including designing, control panels, limit switches, required wiringand cables from panel to motor and required size of shaft etc all as per standard specifications including commissioning and testing complete all as per drawings and specifications and as directed by the Engineer-in-charge.(only power supply point will be provided) |
| 20 | Extra over the cost of rolling shutters for providing wicket gate of specified size in the M.S rollingshutters including fixing with fixing arrangements, hinges, locking arrangements, frames etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 21 | Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m. including injecting cement slurry .This layer will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound @ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofing compound conforming to relevant IS and approved by Engineer-in-charge including mixing 'RECRON 3S' fibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slurry in bottom and all the sides of sunken portion. complete all as per drawings and specifications and as directed by the Engineer-in-charge. The treatment to be tested for water tightness before filling the sunken areas. |
| 22 | Providing and laying integral cement based water proofing treatment including preparation ofsurface as required for treatment of roofs, balconies, terraces, chajjas etc. consisting of flowingoperations (i) Injecting the top slab as required with cement and approved water proof compound solution to fill up all inherent holes, voids honey combs etc.in the concrete slab, setting \\"autoclaved aerated light weight block bats\\" coba in waterproof mortar with necessary gradient for easy flow of water & continue the treatment along the inner faces of parapet or other adjoining wall up to a height of 300 mm in the shape of vatas, finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using river / crushed sand) admixed with proprietary water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including mixing 'polyester fibre mesh at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 X 300 mm square, 3 mm deep (v) The whole terrace so finished shall be flooded with water for a minimum period of 2 weeks for curing and for final test. All above operations to be done in order and complete all as per drawings and specifications and as directed by the Engineer-in-charge.(120 mm Average thickness for terraces using river sand / crushed sand) |
| 23 | Providing and fixing Minimum 17 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Telephone Black colour for kitchen platforms, vanity counters, Wash basin Counters, Door Frames, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 24 | Providing and laying (IPS Flooring) cement concrete flooring 1:2:4, using crushed sand 50 mm thick finished smooth to the required level, finishing with a floating coat of neat cement including cement slurry, providing and fixing 25 X 3 mm aluminium strip, curing, cleaning the surface neatly at the time of handing over the area complete as per specifications and drawings as directed by the Engineer in charge. |
| 25 | Providing and fixing Glazed VITRIFIED floor/wall tiles using Tiles of size 600 X 600 mm in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge. |
| 26 | Providing and laying 50 mm thick cement concrete flooring with concrete hardener topping under layer 38 mm thick cement concrete 1:2:4 and top layer 12 mm thick wearing surface with metallic floor hardener, cement being mixed with metallic floor hardener of approved quality and make in the ratio of 4:1 (4 cement and 1 metallic floor hardener) by weight and this cement hardener compound mixed with 6 mm down graded stone aggregate in the ratio of 1:2 by volume including providing and fixing 25 X 3 mm aluminium strip, This includes cost of cement slurry, finishing to the required finishing and cleaning neatly while handing over the areas etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 27 | Providing and laying minimum 25 mm thick uniform shade Kotah stone flooring over 20 mm thick(Average) base laid over and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing in minimum three levels to obtain mirror polishcomplete with base cement mortar 1:4 (using crushed sand) complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 28 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting, window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-incharge |
| 29 | Extra for nosing in steps of treads Using Kotah stone |
| 30 | Providing and fixing 15 mm thick flooring with acid and alkali resistant tiles and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineer-in-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 200 X 200 X 15 mm of approved colour including providing required slopes and levels ( this work to be carried out through approved specialized agency) complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 31 | Providing and fixing 10 mm thick skirting / Dadooing with acid and alkali resistant tiles and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineerin-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 300 X 300 X 10 mm of approved colour including providing required slopes and levels (this work to be carried out through approved specialized agency) complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 32 | Providing and fixing 1st quality ceramic glazed floor tiles of minimum 300 - 600 mm long and 300 - 600 mm wide and thickness not less than 6 mm conforming to IS 15622 in all colours and shades as approved by Engineer-in-charge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with white cement based Tile grout and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge |
| 33 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622. shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. |
| 34 | Providing 15 mm thick plastering using Ready mix internal plastering compound for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding, Providing and fixing G.I. chicken mesh/GPVC Fiber mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 35 | Providing 20 mm thick plastering using Ready mix external plastering compound for external faces of brickwork / concrete surfaces including water proofing compound @ 2% by weight of cemen, preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary,including Providing and fixing G.I. chicken mesh/GPVC Fiber mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) and complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 36 | Providing 6mm thick plastering using ready mix plaster on cement concrete or Reinforced cement concrete work with white cement based polymer modified self curing mortar, complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 37 | Extra for Plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof |
| 38 | Above 10 metres but up to a height of 13 metres |
| 39 | Above 13 metres but up to a height of 16 metres |
| 40 | Above 16 metres but up to a height of 19 metres |
| 41 | Above 19 metres but up to a height of 22 metres |
| 42 | Above 22 metres but up to a height of 25 metres |
| 43 | Above 25 metres but up to a height of 28 metres |
| 44 | Above 28 metres but up to a height of 31 metres |
| 45 | Above 31 metres but up to a height of 34 metres |
| 46 | Above 34 metres but up to a height of 37 metres |
| 47 | Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 48 | Extra for cutting of reinforcement in RCC, stacking the same and returning the steel scrap to the departmental stores complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 49 | Making the opening in brick masonry for door / window / clear story opening including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface including disposal of mulba/ rubbish to the nearest dumping ground complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 50 | Lead charges for 1st 1 KM or part thereof, by mechanical transport including loading unloading, stacking / levelling etc. Debris up to 1 km |
| 51 | Core cutting in RCC up to and including 50 mm Dia |
| 52 | Core cutting in RCC beyond 50 mm up to and including 100 mm Dia |
| 53 | Core cutting in RCC beyond 100 mm up to and including 150 mm Dia |
| 54 | Core cutting in RCC beyond 150 mm up to and including 200 mm Dia |
| 55 | Manufacture, supply and installation of louvers made of 4 mm thick aluminium composite panels in the external vertical face and flush with the facade system for inlet of fresh air as per the design / details including all necessary aluminium (with minimum 25 micron thick anodisation) frames, sub frames, peripheral flashings to avoid any ingress of water inside the building with stainless steel bird wire mesh on the inside etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 56 | Providing and laying in position with 150 mm thick hard murum bedding RCC hume pipe septic tank ~1800 mm diameter x 2.5 m length, excluding excavation but inclusive of placing in position, commissioning etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge with all pipes vents etc. with connections on both sides. |
| 57 | Providing U3 finish for RCC Surfaces rendering smooth top of the suspended floors ,landings and staircases (treads and risers), walls, slab soffits etc. including grinding / carborandum stone for repairing surface defects in areas where forms are removed, ridges at form joints, honey-combed areas, damage resulting from the stripping of forms and bolt holes including chipping / tooling of bulges and ridges, rubbing, cleaning, necessary scaffolding / staging etc. with C.M 1:2 (using Crushed sand) including a floating coat of neat cement and protecting the surface subsequent to cleaning complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 58 | Providing and applying two part food grade polyamide cured solvent less epoxy lining in two coats of minimum 400 micron DFT over dry, clean and dust free surafe of water reating structures. This coat shall be applied by airless spray technique or suitable method and complete all as per drawings and specifications and as directed by the Engineer-in-charges. |
| 59 | Providing and painting two (or) more coats with Epoxy paint on steel surfaces prepared and appliedas per manufacturer' specifications including a priming coat if specified by the manufacturer,preparation of surface by cleaning with wire brush and rubbing with sand paper to remove dust,dirt etc, after first coat Epoxy based trowelling compound if required, including preparation of thesurface by scrapping, applying sand paper, by cleaning with wire brush and rubbing, making freeof rust, dirt etc. filling the holes, joints, cracks if any etc. complete all as per manufacturers Technical Data, drawings and specifications and as directed by the Engineer-in-charge at site to achieve 200 micron film thickness (50 micron primer coat + 150 micron finishing coat). |
| 60 | Providing and Painting with Epoxy paint (two or more coats) using approved finishing coat at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer, preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, filling the holes, joint, cracks if any , etc complete as per manufacturers Technical Data and as per drawings and specifications and as directed by the Engineer-in-charge to achieve 250 micron Dry film thickness ( 50 Micron Primer coat and 200 micron finishing Coat) (Contractor has to provide Elcometer sampling sheets etc of his cost for testing film thickness) On Concrete surfaces |
| 61 | Providing and Painting with Epoxy paint (two or more coats) ON WALLS & CEILINGS using approved finishing coat at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer , preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water , after first coat Epoxy based trowelling compound if required , including preparation of the surface by scrapping, applying sand paper, filling the holes, joint, cracks if any , complete as per manufacturers Technical Data and as per drawings and specifications and as directed by the Engineer-in-charge ( Contractor has to provide Elcometer sampling sheets etc at his cost for testing film thickness) On Concrete surfaces.(500 micron total film thickness ( High build epoxy)). |
| 62 | Providing and applying white cement based wall putty over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 63 | Providing and Painting two coats of synthetic enamel paint on Steel Surfaces of approved brand and manufacture to give an even shade without primer coat. Including preparation of the surfaces, scaffolding complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 64 | Providing, painting, finishing walls with two coats of anti-algae, weather proof acrylic smooth emulsion paint with silicon additives on sand face plaster/ plain plaster & concrete surfaces of required shade over new work over a base coat of exterior cement primer including preparation of the surfaces, scaffolding complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 65 | Providing and Painting with 1st quality acrylic emulsion paint with Two coats on new work and manufacturer and of required shade and colour, including scaffolding, preparation of the surfaces, etc., including a coat of approved cement primer as per manufacturer's specifications and complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 66 | Providing and fixing double tubular scaffolding system using H- frames / cup lock type on the exterior / interior side made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. The painting area above 6m shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding and this item will be operated for epoxy painting beyond 6m height. |
| 67 | Note for Item No. 58.1 to Item No. 58.4 below:Designing, supplying and installing proprietary separation / expansion / seismic joints in RCC framed structure including columns, beams, slab, roof, pavements, walls, floors or any other location comprising of the following as per detailed specification, warranty and as directed by Engineer.The joint cover assembly system comprises of:(i) Elastomeric joint system : shall be made of extruded polyvinyl chloride or approved equivalent material with shore \\"A\\" hardness of 55+5 with UV stabiliser including provision of multi-cellular profile able to transfer loads to adjacent aluminium extrusions. The profile shall be flexible and exhibit a non-slip exposed surface that remains flat during all phases of movement (ii) Aluminium frame members : shall be made out of extruded aluminium sections conforming to ASTM B221. The alloy shall be 6061-T6 or 6063-T5 or H1200 or approved equivalent. The exposed surface shall be mill finished. (iii) Cover Plates, (iv) Self centering / turn bar arrangement : shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions so as to accommodate multi-directional seismic movement without causing stress to joint components. The centre plate shall remain flush during thermal movement and during seismic movement, the centre plate shall displace temporarily and slide over the floor. (v) Sealants : shall be a one part polysulphide base synthetic rubber / silicon sealant. The item shall include for providing secondary seal /visual seal /functional vinyl seal, lubricant adhesive as required at the back for full seismic movement for specific structural gap, fixing to RCC frame work / MS structures / Masonry walls using approved anchor fasteners /sealants on either side of seismic / separation joint. The entire system shall be fully gasketed to eliminate transition rattle, including providing & applying silicone sealant between the joint and abutting the substrate, grouting, scaffolding / staging for all heights, leads & levels etc. all complete as per approved shop drawings, manufacturer's specifications and as directed by the Engineer. The item shall include for repairing & profiling of the existing joint line with the help of approved polymer modified mortar to be fixed in alignment and straight line as per joint design width and joint design complete. The item shall also include for providing and fixing of 1.2mm thick EPDM / PVC water barrier membrane over the joint profile with the help of special adhesive and necessary loop throughout the joint profile before fixing of the joint system to ensure water tight joints etc. complete |
| 68 | Designing, supplying and installing proprietary horizontal floor to floor expansion / separation / seismic joint cover assembly system of approved manufacturer.WIth Stainless Steel Cover Plate : shall be made out of not less than 5 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approvedself centering arrangement. The exposed surface shall be mill finished complete all as per drawings and specifications and as directed by the Engineer-in-charge. (Refer Note for Item No. 58).For 250 mm to 300mm wide joints |
| 69 | Designing, supplying and installing horizontal floor to wall expansion / separation / seismic joint cover assembly system of approved manufacturer & comprising ofWIth Stainless Steel Cover Plate : shall be made out of not less than 2 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished complete all as per drawings and specifications and as directed by the Engineer-in-charge. (Refer Note for Item No. 58).For 250 mm to 300mm wide joints |
| 70 | Designing, supplying and installing vertical wall to wall expansion / separation / seismic joint cover assembly system of approved manufacturer & comprising ofWith Stainless Steel Cover Plate : shall be made out of 1.6 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished complete all as per drawings and specifications and as directed by the Engineer-in-charge. (Refer Note for Item No. 58).For 250 mm to 300mm wide joints. |
| 71 | Designing, supplying and installing horizontal ceiling to ceiling expansion / separation / seismic joint cover assembly system of approved manufacturer & comprising ofWith Stainless Steel Cover Plate : shall be made out of 1.6 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished complete all as per drawings and specifications and as directed by the Engineer-in-charge.(Refer Note for Item No. 58).For 250 mm to 300mm wide joints. |
| 72 | Providing and inserting 12 mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20 mm to 30 mm) up to depth from 30 mm to 80 mm at required spacing and making the hole and cracks dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical and allow it to cure complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 73 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. (The payment shall be made on the basis of actual weight of approved grout injected. Epoxy injection grout in concrete/RCC work. |
| 74 | Providing and fixing Indian water closet (Orissa pan) of approved make with 100 mm China wareP or S trap, One no. 10 litre High level or low level white PVC flushing cistern with flush pipe &bend with manually controlled device (handle lever) conforming to IS:7231, PVC 15 mm Inletconnection with all fittings and fixtures complete including all connection, embedding in positioncommissioning, cleaning etc. all as per drawings and specifications and as directed by theEngineer-in-charge(White Vitreous china Orissa pattern W.C. pan of size 580x440 mm). |
| 75 | Providing and fixing E.W.C. pan in White colour with 'P' or 'S' Trap with ISI marked white solid plastic seat and lid, 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, flush bend, fixing EWC with C.P brass screws, 15 mm PVC heavy quality inlet connection of 450 mm long, including testing , commissioning & cleaning etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge .E.W.C. pan in White colour with ISI marked white solid plastic seat and lid. |
| 76 | Providing and fixing white vitreous (Single half stall urinal with C.P brass Flush valve). china flat back half stall urinal size 580 x 380 x350 mm / 610 mm Aquaseal model with 32mm C.P flush valve with standard flush pipe and C.P. brass spreaders, 32mm urinal waste coupling with dome grating and clamp etc. including making G.I water line connection complete all as per drawings and specifications and as directed by the Engineer-in-charge (Only G.I. pipes will be paid under relevant Item ). |
| 77 | Providing and fixing vitreous China wash basin and colour with C.I. brackets,15 m C.P. brass pillar tap,15 mm x 600mm long PVC Inlet connection, 32 mmheavy quality C.P. brass waste coupling of standard pattern, including painting of fittings andbrackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge. |
| 78 | White vitreous China counter top / counter below wash basin size 560 x 410 mm / 560 x 450 mmwith single 15 mm C.P. brass pillar tap (OVAL / ROUND Models) |
| 79 | Providing and fixing Heavy quality Flexible PVC waste pipe (Semi rigid or Flexible) for sink or wash basin including PVC waste fittings etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge (40 mm dia flexible PVC (semi-rigid) waste pipe) |
| 80 | Providing and fixing 6 mm thick mirrors of with bevelled edges complete with 6 mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers including providing and fixing mirrors with approved stainless steel 304 grade STUDS (with wall spacers) complete. all as per specifications and as directed by the Engineer-in-charge |
| 81 | Providing and fixing C.P. Brass toilet paper holder Recessed type with Brass C.P screws etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 82 | Providing and fixing Heavy Quality C.P .Brass waste coupling of following dia for wash basin and sink, size and quality all as directed complete |
| 83 | C.P Brass Waste coupling 32 mm Dia and minimum 79 mm length Half threaded or Full threaded as per requirement, complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 84 | Providing and fixing Heavy Quality CP Brass Bottle trap 31 / 32 mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal for wash basins / urinal etc complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 85 | Providing and fixing C.P brass towel rail of 600 mm long complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 86 | Providing and fixing 15 mm C.P Brass Urinal spreader size with 1/2\\" BSP thread and shapes , weighing not less than 60 gms, complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 87 | Providing and fixing Brass C.P 15 mm Presstomatic seriesAuto shut Urinal Flush cock, complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 88 | Providing and fixing 15 mm PVC inlet connection suitable for hot and cold water 600 mm long with nuts and washers complete for wash basins/ Urinals etc. with all necessary acessories complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 89 | Providing, supplying and fixing JET spray with 1.00 metre long flexible tube connection inEuropean / Anglo Indian closet under seat cover fixtures complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 90 | Providing and fixing 150 X150 mm soap dish of white vitreous Chinaware, of including chasing walls making good the same after fixing the China Soap dish etc. complete all as per specifications and as directed by the Engineer-in-charge . |
| 91 | Providing , Laying , jointing, fixing and testing for OPEN plumping lines (No Concealed) Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples,reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydralic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, Fixing in walls / trenches using clamps etc . including 2 coats of Syn enamal paint over a coat of primer , making good by filling with concrete 1:3:6 and complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 92 | 15 mm n/b G.I pipe |
| 93 | 20 mm n/b G.I pipe |
| 94 | 25 mm n/b G.I pipe |
| 95 | 32 mm n/b G.I pipe |
| 96 | 40 mm n/b G.I pipe |
| 97 | 50 mm n/b G.I pipe |
| 98 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as per drawings and specifications and as directed by the Engineer-in-charge . Concealed work, including cutting chases and making good the walls etc. |
| 99 | 15 mm dia niminal pipes |
| 100 | 20 mm dia niminal pipes |
| 101 | 25 mm dia niminal pipes |
| 102 | 32 mm dia niminal pipes |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as per drawings and specifications and as directed by the Engineer-in-charge. Internal work - Exposed on wall |
| 104 | 40 mm dia niminal pipes |
| 105 | 50 mm dia niminal pipes |
| 106 | Providing and Fixing 3 layer PP-R ( Poly proplylene Random co Polymer) Pipes ( as per I.S 15801/2008 ) of specified Grade and size , U.V stabilised & anti- microbial fusion welded, having thermal stability for Hot & Cold water supply including all PP-R Plain & Brass Cp threaded PP-R fittings including chasing the walls , Concealing the Pipes with fixing arrangements . This includes testing of joints & pipelines complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 107 | PP-R pipes PN-16 / SDR 7.4 - 16 mm O/D ( Concealed) |
| 108 | PP-R pipes PN-16 / SDR 7.4 - 20 mm O/D ( Concealed) |
| 109 | PP-R pipes PN-16 / SDR 7.4 - 25 mm O/D ( Concealed) |
| 110 | Making connection of distribution branch with G.I Main of 25 to 40 mm nominal bore by providing and fixing tee including cutting and threading the pipes etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 111 | Providing and fixing GM Gate valves with handle wheels as per IS: 778, complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 112 | 15 mm n.b |
| 113 | 20 mm n.b |
| 114 | 25 mm n.b |
| 115 | 32 mm n.b |
| 116 | 40 mm n.b |
| 117 | 50 mm n.b |
| 118 | Providing and fixing brass ball cock(50mm dia) of heavy quality of following sizes with arm rod and Plastic Ball floats complete all as per drawings and specifications and as directed by the Engineer-in-charge . |
| 119 | Providing and fixing G.M Non-return valve (50 mm dia non-Return Valve (Vertical) of approved quality of following sizes in water lines vertical / horizontal complete all as per drawings and specifications and as directed by the Engineer-in-charge |
| 120 | Providing and fixing C.P Brass Bib cock of Heavy Quality complete all as per drawings and specifications and as directed by the Engineer-in-charge. (Samples to be got approved by the Engineer-in-charge) |
| 121 | 15 mm dia Bib cock. |
| 122 | 15 mm Dia LONG BODY Bib cock. |
| 123 | Providing and fixing C.P Brass Angle cock of Heavy Quality , for wash basin inlet / flush cistern etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. (Samples to be got approved by the Engineer-in-charge). |
| 124 | 15 mm n.b CP Brass Angle cock. |
| 125 | Providing and fixing PVC inlet connection pipes heavy quality suitable for hot and cold including CP brass unions and nuts 15 mm dia 450 mm long etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 126 | Providing and fixing 15 mm C.P brass 2 in 1 bib cock and Angle cock combination of Heavy Quality complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 127 | Providing, supplying, Fabricating and fixing 500mm long G.I pipe sleeves using \\"C\\" class pipes with puddle flange of specified size made of 6 mm thick M.S plate and pipes threaded at one end / both end as specified embedding in the concrete for Water tanks, etc . complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 128 | Heavy Quality 'C' Class 40 mm n/b G.I pipe with Puddle flange of 150x 150 mm. |
| 129 | Heavy Quality 'C' Class 50 mm n/b G.I pipe with Puddle flange of 150x 150 mm |
| 130 | Heavy Quality 'C' Class 80 mm n/b G.I pipe with 200mmx200mm Puddle flange |
| 131 | Providing, laying to the slope specified and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the order of 1:1 (1 cement : 1 fine sand) including testing of joints etc.complete all as per drawings and specifications and as directed by the Engineer-in-charge.(complete excluding excavation and refilling which will be paid under relevant Item). |
| 132 | 150 mm diameter Grade \\"A\\" Stoneware Pipe |
| 133 | Providing and fixing square mouth S.W. gully trap grade 'A' complete with CI grating brick masonry chamber with water tight CI cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design, complete all as per drawings and specifications and as directed by the Engineer-in-charge |
| 134 | 150x100 mm size Gully Trap \\"P\\" type |
| 135 | Providing and laying non pressure NP2 class RCC Hume pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2, laying to the levels, slopes and as per the drawings and specifications and as directed by the Engineer-in-charge including testing of joints etc. complete. |
| 136 | 150 mm Dia RCC Hume pipe class Np2 |
| 137 | 300 mm Dia RCC Hume pipe class Np2 |
| 138 | Providing and constructioning Inspection chambers of Internal size clear dimention of 900x600 mm in 230 thick brick masonry with Cement mortat 1:4 over a bed of 150 mm thick 1:4:8 cement concrete foundation, Plastering with cement mortar 1:4 20 mm thick on inside , out side and all exposed sufaces finished with a floating coat of neat cement, brick corbelling at top to provide opening of 900 X 450mm, embedding the Frame and cover with CC 1:2:4 concrete , and fixing Cast Iron Steps if necessary at 300mm intervals complete . Depth of Chamber not exceeding 900 mm.complete all as per drawings and specifications and as directed by the Engineer-in-charge. ( Excavation, Soling,Cast Iron Cover and C.I steps will be paid separately under relevant item) |
| 139 | Supplying and fixing Cast Iron Man hole cover or Cast Iron Steps cover as specified in the drawings,specifications or as directed by the Engineer in charge |
| 140 | Supplying and fixing CI cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg, complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 141 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix cement plastered on both sides with cement mortar 1:3 finished with a floating coat of neat cement and making necessary channels for the drain etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 142 | For pipes 100 to 230 mm diameter |
| 143 | Providing, supplying, fixing in position, under floors or in walls Centrifugally cast iron pipes including required specials like bends, tees, 'Y' collers, cowl etc for Soil, waste and ventilation pipes Confirming to IS.3989 including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes,painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 144 | 100 mm dia Centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kg lead / joint |
| 145 | 75 mm dia Centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint |
| 146 | Providing, supplying, fixing in position in walls Rain water down take pipes using Centrifugally cast iron pipes 3.00 metres long) including required specials like bends, shoes etc for Rain water down take pipes Confirming to IS.3989 including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes,painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 147 | 200 mm C.I Rain water down take Pipe with 1.5 kg lead / joint as per IS 3989 |
| 148 | 150 mm C.I Rain water down take Pipe with 1.20 kg lead / joint as per IS 3989 |
| 149 | 100 mm C.I Rain water down take Pipe with 1.00 kg lead / joint IS 3989 |
| 150 | Providing and fixing Cast Iron Nahani Trap / Floor Trap of 100 mm inlet and 75 mm outlet, ( weighing 5.80Kgs each), jointing with Lead with the connection pipes, placing as per the drawings, embedding in Cement concrete 1:2: 4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kgs/sq.cm pressure and fixing 1 No 125 mm dia C. P Brass Grating , complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 151 | Providing and fixing heavy quality stainless steel / C.P brass grating for floor traps / nahani traps all as to complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 152 | SS Grating 150 mm Square with Frame |
| 153 | Providing and fixing 150 mm x 150mm Cast Iron grating for rain water down takes at roof including chipping and grouting complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 154 | Providing and fixing 200 mm x 200mm Cast Iron grating for rain water down takes at roof including chipping and grouting complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 155 | Providing and fixing 300 mm x 300mm Cast Iron grating for rain water down takes at roof including chipping and grouting complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 156 | Crack Filling:Opening non structural hairline cracks in plaster surface and fill the cracks up to 5mm with high quality weather durable acrylic emulsion polymer paste in following steps.Apply primer coat prepared with high quality weather durable acrylic emulsion polymer Paste and water in 1:1 proportion over the crack.Fill high quality weather durable acrylic emulsion polymer Paste when the surface is tacky and not dried completely with a spatula. Allow it set for 24 hours and then apply another coat of high quality weather durable acrylic emulsion polymer Paste. Large and separation cracks should be filled with Polymer Modified Mortar in SSD condition |
| 157 | Priming Coat:Providing, and applying single coat of exterior penetrating water-based primer composed of acrylic emulsion polymer primer for superior bonding after thorough cleaning of all laitance, loose material, oil, grease, etc. Allow the primer to cure according its technical instructions. |
| 158 | Exterior Waterproof Coating:Providing & Apply one coats of Waterproof Coating composed of high quality emulsion polymer, weather durable pigments, properly selected & graded fine fillers, additives & biocides of approved makes without any dilution Maintain the spreading rate of 4.20 -4.70 Sq.mtr per litre / coat application to achieve about 100-120 microns DFT. Apply second coat of high quality acrylic emulsion polymer of approved make Raincoat Select Top Coat with interval of 6-8 hours without any dilution spreading at rate of 6.0 -6.5 Sq.mtr / per litre / coat to achieve DFT of 60 –70 microns. The material shall have following technical properties: Attains hairline crack bridging up to 2 mm, Elongation of >100 % as per ASTMD 412; Tensile strength 2.50 Mpa per ASTM D 412, Passes Water Resistance as per SS500 standard, Complies to anti carbonation test as per EN 1062 part 6. |
| 159 | Providing and fixing in position 50 mm thick Joint filler board of Approved make in expansion joints to the required size and shape, placing and keeping in position complete as per specifications and drawings and as directed by the Engineer in charge. |
| 160 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12 mm dia. |
| 161 | Providing and laying in position bitumen hot sealing compound for expansion joints using standard make |
| 162 | Supply and erection of GI enclosure fabricated out of 1.6mm thick pre galvanised GI sheet steel with required cutting, welding, bending, stiffners as per drawings and embed in concrete or brick wall, cutting brick wall to suit size, etc as required under the instruction of Engineer-In-Charge. |
| 163 | Supply of enclosure |
| 164 | Installation of enclosure |
| 165 | Supply and embedment of heavy duty hot dipped GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Surfacr mounted Junction box of suitable size as required suit at site shall be provided. |
| 166 | Supply of 25mm GI conduit |
| 167 | Installation of 25mm GI conduit |
| 168 | Supply and embedment of 16 SWG black enameled heavy duty rigid mild steel (MS) ERW conduit pipe of following sizes along with all accessories such as bends, junction box, socket, check nut etc. including making threads, removing burrs, making chasis in wall, connection of accessories, drawing of fish wire, laying in RCC slab, beam, wall, cutting & laying in brick wall etc. as required under the instruction of engineer- in charge. Deep junction box of min. 75mm deep shall be provided. |
| 169 | 25mm MS conduit |
| 170 | 40 mm MS conduit |
| 171 | Supply of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 172 | Supply of flexible GI conduit pipe of size 26 MM |
| 173 | Installation of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 174 | Installation of flexible GI conduit pipe of size 26 MM |
| 175 | Supply and Laying of 14 SWG Cu-ETP grade bare solid tinned copper conductor. |
| 176 | Supply of 14 SWG conductor |
| 177 | Installation of 14 SWG conductor |
| 178 | Supply and Installation of Heavy Duty Class-C GI pipe of following size to be laid in brick wall for laying cables. |
| 179 | 100NB |
| 180 | Supply of required material and making of exothermic braze joints of copper conductor with other conductor or copper earthing pad including removal of burrs and debris as per technical specification and instruction of engineer in charge. |
| 181 | Supply of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 182 | Supply of 12 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 36 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 183 | Supply of 4 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 184 | Supply of 6 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 185 | Supply of 8 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 24 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 186 | Supply of 6 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 187 | Supply of 4 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 188 | Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 189 | Installation, Testing and Commissioning of 12 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 36 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 190 | Installation, Testing and Commissioning of 4 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 191 | Installation, Testing and Commissioning of 6 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 192 | Installation, Testing and Commissioning of 8 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 24 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 193 | Installation, Testing and Commissioning of 6 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 194 | Installation, Testing and Commissioning of 4 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 195 | Supply of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 196 | Supply of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 197 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 198 | Supply of MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 199 | Supply of MCB DB with Incomer of 50A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 200 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 201 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 4 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 202 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 203 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 204 | Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 205 | Installation, Testing and Commissioning of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 206 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 207 | Installation, Testing and Commissioning of MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 208 | Installation, Testing and Commissioning of MCB DB with Incomer of 50A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 209 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 210 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 4 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 211 | Installation, Testing and Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 212 | Installation, Testing and Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 213 | Supply of following LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specification. |
| 214 | Supply of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 215 | Supply of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 216 | Supply of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 217 | Supply of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W per tube. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver). |
| 218 | Supply of LED integral driver Flood light with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 6500K and a CRI>70. The luminaire shall meet IP65 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 35W (including driver). |
| 219 | Supply of 4ft Functional Batten (approx dim.140mm x 105mm x 1219mm)with 40W LED Tubelight (acid & corrossion proof) with a nominal system lumen output of 4800 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 40W(including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 220 | Supply of LED street light fitting of not more than 35W having System Efficacy >120lm/W, system output >=4200 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 5700K, SDCM<5, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Luminaire shall sustain 325V/440V stress voltage protection for 8Hrs, HV cutoff: 325V/440V. Driver shall have 4KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 221 | Supply of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver). |
| 222 | Supply of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED Highbay with a nominal system lumen output of 18000 lumens and a minimum system efficacy of not less than 140 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a CCT of 5700K and CRI > 70 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 130W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 223 | Supply of 4ft Functional Batten (approx. dim. 140mmx105mmx1219mm) with 2x36W LED Tube (Flameproof) with a nominal system lumen output of 8640 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD<10% and PF>0.95 (including BIS compliant integrated driver) and other requirements shall be as per tender technical specifications. The mounting shall be ceiling suspende with Hot dipped GI rod, SS srew, Anchoe Fastener etc. and including all accessories for complete installation. |
| 224 | Installation, Testing and Commissioning of following LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specifiction. |
| 225 | Installation, Testing and Commissioning of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 226 | Installation, Testing and Commissioning of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 227 | Installation, Testing and Commissioning of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 228 | Installation, Testing and Commissioning of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W per tube. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver). |
| 229 | Installation, Testing and Commissioning of LED integral driver Flood light with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 6500K and a CRI>70. The luminaire shall meet IP65 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 35W (including driver). |
| 230 | Installation, Testing and Commissioning of 4ft Functional Batten (approx dim.140mm x 105mm x 1219mm)with 40W LED Tubelight (acid & corrossion proof) with a nominal system lumen output of 4800 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 40W(including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 231 | Installation, Testing and Commissioning of LED street light fitting of not more than 35W having System Efficacy >120lm/W, system output >=4200 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 5700K, SDCM<5, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Luminaire shall sustain 325V/440V stress voltage protection for 8Hrs, HV cutoff: 325V/440V. Driver shall have 4KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 232 | Installation, Testing and Commissioning of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver). |
| 233 | Installation, Testing and Commissioning of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED Highbay with a nominal system lumen output of 18000 lumens and a minimum system efficacy of not less than 140 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a CCT of 5700K and CRI > 70 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 130W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 234 | Installation, Testing and Commissioning of 4ft Functional Batten (approx. dim. 140mmx105mmx1219mm) with 2x36W LED Tube (Flameproof) with a nominal system lumen output of 8640 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD<10% and PF>0.95 (including BIS compliant integrated driver) and other requirements shall be as per tender technical specifications. The mounting shall be ceiling suspende with Hot dipped GI rod, SS srew, Anchoe Fastener etc. and including all accessories for complete installation. |
| 235 | Supply of the following Modular surface mounted type switch as per Technical specifications. |
| 236 | Supply of switch box set consisting of 1 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 237 | Supply of switch box set consisting of 2 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 238 | Supply of switch box set consisting of 3 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 239 | Supply of switch box set consisting of 4 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 240 | Installation of the following Modular surface mounted type switch as per Technical specifications. |
| 241 | Installation, Testing and Commissioning of switch box set consisting of 1 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 242 | Installation, Testing and Commissioning of switch box set consisting of 2 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 243 | Installation, Testing and Commissioning of switch box set consisting of 3 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 244 | Installation, Testing and Commissioning of switch box set consisting of 4 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 245 | Supply of the following modular switches and plug sockets as per technical specification. |
| 246 | Supply of 2 nos. of 6/16A (compatible with both 6A and 16A with shutter), Single phase Modular Decorative Type Socket with Polycarbonate box as required, 16A Switch and heavy duty polycarbonate Face Plate, 2 nos. of 16A plug tops and suitable mounting arrangements as per technical specification |
| 247 | Supply of 1 nos. of 6A Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. The whole set shall be mounted inside a IP66 enclsoure. |
| 248 | Installation of the following modular switches and plug sockets as per technical specification. |
| 249 | Installation, Testing and Commissioning of 2 nos. of 6/16A (compatible with both 6A and 16A), Single phase Modular Decorative Type Socket with Polycarbonate/GI box as required, 16A Switch and heavy duty polycarbonate Face Plate, 2 nos. of 16A plug tops and suitable mounting arrangements as per technical specification |
| 250 | Installation, Testing and Commissioning of 1 nos. of 6A Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. The whole set shall be mounted inside a IP66 enclsoure. |
| 251 | Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification |
| 252 | Supply of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 253 | Supply of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 254 | Installation/drawing through concealed/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 as per conductor class 2 of IS:8130/1984 as per technical specification. |
| 255 | Installation/drawing of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 256 | Installation/drawing of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 257 | Supply, Fabrication and Installation of Standard steel sections as per IS 2062 Grade BR for light frame, base frame, wall frames, brackets for supporting equipments etc. including all accessories, SS screw, bolts etc. Fabrication shall include drilling, entiling, welding by qualified welder, wire brush cleaning, testing DPT etc., supply of all consumables like gas, approved welding rods as per EIC and tender tech spec. After fabrication two coats of epoxy based primer and two coats of finish epoxy paints shall be applied. |
| 258 | Supply and laying of 95 sq. mm Class-2 stranded bare tinned copper conductor underground upto depth of 1 meter, including excavation, connection with earth pit at one end and connection with test link box at other end, including clamping, connection through brazing/ bolting , refilling the trench etc. as per instructions by Engineer-In-Charge. |
| 259 | Supply of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 260 | Installation of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 261 | Supply and surface/concealed laying including making chasing on wall of 10 sq. mm stranded tinned coper conductor, connection with earth pad at one end and DBs/ sockets/ motor at other end including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 262 | Supply of 10 sq. mm stranded tinned coper conductor |
| 263 | Installation of 10 sq. mm stranded tinned coper conductor |
| 264 | Supply and surface/concealed laying of 2 x 10 sq. mm Cu PVC insulated earthing conductor in 25mm HDPE pipe including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 265 | Supply |
| 266 | Installation |
| 267 | Supply and installation of 25 mm HDPE pipe as per tender specifications. |
| 268 | Supply and installation of tinned Cu Lugs and Brass bolt suitable to following sizes of earthing conductors as per attached technical specification |
| 269 | Copper lug suitable for 10 Sq.mm stranded tinned copper conductor |
| 270 | Supply and installation of M10 brass nut bolt, 3/4\\" long suitable for 10mm threaded hole for making connection to earth pad. |
| 271 | Copper lug suitable for 95 Sq.mm stranded tinned copper conductor |
| 272 | Supply of Busbar Insulator of size M8 x 40mm, MOC: Epoxy as per tender specification. |
| 273 | Installation of Busbar Insulator of size M8 x 40mm for fixing of downcomer conductor from lightening arrestor as per tender specification. |
| 274 | Supply and Installation of 25 mm X 3 mm thick tinned copper strip including connection/ terminating with nut, bolt, spring, washer etc. as required. |
| 275 | Supply of 25 mm X 3 mm thick copper strip |
| 276 | Installation & Testing of 25 mm X 3 mm thick copper strip |
| 277 | Supply and fixing vertical air termination made up of 20mm dia, 1mtr long copper rod attached to 145mm dia Copper sphere having drilled and tapped holes for fixing 5nos. of 390mm long spikes and square copper base plate of 150mm length and 10mm thickness as per technical specification and approved drawing. |
| 278 | Supply of vertical air termination |
| 279 | Installation of vertical air termination |
| 280 | Supply, Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor with inbuilt or external power pack and auxiliary relay having min 15 mtr sensing range in 180 deg orientation and time delay ranges from 30sec to 30min and should have output relay capacity of 1000W (for LED lighting fixtures). |
| 281 | Supply of Ceiling mounted dual type occupency sensor |
| 282 | Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor |
| 283 | Supply, Installation, Testing and Commissioning of Occupancy sensor bypass switch box having 3pole rotary switch fixed on GI enclosure with cover. |
| 284 | Supply of Occupancy sensor bypass switch box |
| 285 | Installation, Testing and Commissioning of Occupancy sensor bypass switch box |
| 286 | Supply and Installation of GI Anchor Fastner of size M8x80 MM by drilling through concrete block as per site requirement for fixing plate Eps or other structures as per the tender specification. |
| 287 | Supply of GI Anchor Fastner of size M8x80 MM |
| 288 | Installation of GI Anchor Fastner of size M8x80 MM |
| 289 | Supply and Installation of 1.2 mm thick pre-galvanized GI sheet cover plates including marking, cutting (as per site requirement) and fixing on top of JB openings in wall and slab bottom/ ceiling at approx height of 5mtrs as per tender specifications. |
| 290 | Supply, Fabrication and Installation of Pre-Galvanized Powder Coated dome shaped cover of 1.6mm sheet thickness, 1220mm long for LED Tube light fittings as per specifications and instructions of Engineer-in-charge. |
| 291 | Supply of 2-way Face plate with 2 RJ11 Socket as per technical specification |
| 292 | Installation of 2-way Face plate with 2 RJ11 Socket as per technical specification |
| 293 | Supply of 4 way 4 Terminal Junction Box for PA System as per Tender specification. |
| 294 | Installation of 4 way 4 Terminal Junction Box for PA System as per Tender specification. |
| 295 | Supply of 50 Terminal Junction Box for PA System as per Tender specification. |
| 296 | Installation of 50 Terminal Junction Box for PA System as per Tender specification. |
| 297 | Supply of 20 Terminal Junction Box for PA System as per Tender specification. |
| 298 | Installation of 20 Terminal Junction Box for PA System as per Tender specification. |
| 299 | Supply of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 400+400 pairs of Telephone cable as per the technical specification. |
| 300 | Installation, Testing and Commissioning of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 400+400 pairs of Telephone cable as per the technical specification. |
| 301 | Supply of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 100+100 pairs of Telephone cable as per the technical specification. |
| 302 | Installation, Testing and Commissioning of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 100+100 pairs of Telephone cable as per the technical specification. |
| 303 | Supply of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 50+50 pairs of Telephone cable as per the technical specification. |
| 304 | Installation, Testing and Commissioning of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 50+50 pairs of Telephone cable as per the technical specification. |
| 305 | Supply of 1 Pair x 1.5 Sq.mm twisted pair unarmoured PVC insulated, FRLS PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 306 | Laying of 1 Pair x 1.5 Sq.mm twisted pair unarmoured PVC insulated, FRLS PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 307 | Supply of 2 Pair 0.6mm copper conductor Telephone cable as per tender specifications. |
| 308 | Installation of 2 Pair 0.6mm copper conductor Telephone cable as per tender specifications. |
| 309 | Supply of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor, armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 310 | Laying of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor,armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 311 | Supply of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 312 | Laying of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail