Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refilling with selected excavated earth inlayers of not more than 500 mm thick, each layer well rammed and consolidated includingdisposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of vegetation, grass, etc. complete and as directed by the Engineer-in-charge.From 0.00 to 1.50 m depth from average ground level |
| 2 | Lead charges for 1st 1 KM or part thereof, by mechanical transport including loading unloading,stacking / levelling etc.Soil |
| 3 | Supplying, stacking and laying of 230 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, moorum etc. complete all as per specifications and as directed by the Engineer-in-charge with outside material |
| 4 | Providing and laying in position cement concrete (RCC or PCC) of 1:1.5:3 at all levels (1 cement, 1.5 crushed sand, 3 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete as per specifications and drawings but excluding the cost of shuttering, centering and steel reinforcement. |
| 5 | Priming Coat:Providing, and applying single coat of exterior penetrating water-based primer composed of acrylic emulsion polymer primer for superior bonding after thorough cleaning of all laitance, loose material, oil, grease, etc. Allow the primer to cure according its technical instructions |
| 6 | Exterior Waterproof Coating:Providing & Apply one coats of Waterproof Coating composed of high quality emulsion polymer, weather durable pigments, properly selected & graded fine fillers, additives & biocides of approved makes without any dilution Maintain the spreading rate of 4.20 -4.70 Sq.mtr per litre / coat application to achieve about 100-120 microns DFT. Apply second coat of high quality acrylic emulsion polymer of approved make Raincoat Select Top Coat with interval of 6-8 hours without any dilution spreading at rate of 6.0 -6.5 Sq.mtr / per litre / coat to achieve DFT of 60 –70 microns. The material shall have following technical properties: Attains hairline crack bridging up to 2 mm, Elongation of >100 % as per ASTMD 412; Tensile strength 2.50 Mpa per ASTM D 412, Passes Water Resistance as per SS500 standard, Complies to anti carbonation test as per EN 1062 part 6. |
| 7 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications for super structure. |
| 8 | Providing and Laying Solid cement concrete block masonry with M-5 Grade of 190/ 140 mm thick in super structure in cement mortar 1:4 (using crushed sand). The rate shall also including drilling of holes (if any) for fixing of rebar by applying chemical or welding or as directed by EIC including Making the cut out opening in masonary for flush concealing DB/plug point/switch box enclosure including dismantling in floor or walls by cutting masonary and making good the damage to walls, etc. existing surface including disposal of rubbish to the naerest dumping ground at a minimum distance of 50m away from the building. Note:( Reinforcement will be paid under relevant item) |
| 9 | Providing, centering, shuttering Form work using steel plates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels for superstructure |
| 10 | Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Steel supplied by the contractor |
| 11 | Structural Steel Works of MS rolled single / built-up sections conforming to IS 2062 for staircase, edge angles, nosing angles in trench covers, gratings etc., mild steel embedment part for lining supports, sampling blisters, embedded cubicles, SBT line supports, trolleys, MSM EPs, RSW EPs, Electrical Plug EPs, PE door EPs, crane & monorail related EPs, trench pipe supports, various pipe EPs and plate EPs, ACVE related EPs such as duct EP, angle or channel frames for filter banks and closing ducts, supporting arrangement for EPs embedded in concrete, column guards, monorails, railings, handrails, ladders, box column sections, Monorail, built-up sections, crane girders, MS grid work for lining works, crane girders, trolley rails, joists, channels, in M.S Plain Plates and chequered Plates in Trench Covers, gratings, connection plates, supporting arrangement for EPs embedded in concrete etc., including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge |
| 12 | Providing and laying (IPS Flooring) cement concrete flooring 1:2:4, using crushed sand 50 mm thick finished smooth to the required level, finishing with a floating coat of neat cement including cement slurry, curing, cleaning the surface neatly at the time of handing over the area complete as per specifications and drawings as directed by the Engineer in charge |
| 13 | Providing and laying 50 mm thick cement concrete flooring with concrete hardener topping under layer 38 mm thick cement concrete 1:2:4 and top layer 12 mm thick wearing surface with metallic floor hardener, cement being mixed with metallic floor hardener of approved quality in the ratio of 4:1 (4 cement and 1 metallic floor hardener) by weight and this cement hardener compound mixed with 6 mm down graded stone aggregate in the ratio of 1:2 by volume including providing and fixing 30 X 3mm glass strip, This includes cost of cement slurry, finishing to the required finishing and cleaning neatly while handing over the areas etc. complete as per specifications and drawings. |
| 14 | Providing and fixing Glazed VITRIFIED floor/wall tiles in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge .Using Tiles of size 600 X 600 mm |
| 15 | Providing and fixing 1st quality ceramic glazed floor tiles of minimum 300 - 600 mm long and 300 - 600 mm wide and thickness not less than 6 mm conforming to IS 15622 in all colours and shades as approved by Engineer-in-charge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with white cement based Tile grout and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge |
| 16 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge |
| 17 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting, window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-incharge |
| 18 | Extra for nosing in steps of treads Using Kotah stone |
| 19 | Providing and fixing Minimum 16 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Telephone Black colour for kitchen platforms, vanity counters, Wash basin Counters, Door Frames, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete as directed by the Engineer-in-charge at all levels |
| 20 | Drilling suitable holes in reinforced or plain cement concrete with powerdriven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout but excluding the cost of reinforcement,all complete as per direction of Engineer-In-Charge. |
| 21 | Providing and fixing 15 mm thick flooring with acid and alkali resistant tiles of colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineer-in-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 200 X 200 X 15 mm of approved colour including providing required slopes and levels ( this work to be carried out through specialized agency) complete as per specifications and as directed by the Engineer-in-charge |
| 22 | Providing and fixing 10 mm thick skirting / Dadooing with acid and alkali resistant tiles of approved and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineerin-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 300 X 300 X 10 mm of approved colour including providing required slopes and levels (this work to be carried out through approved specialized agency) complete as per specifications and as directed by the Engineer-in-charge |
| 23 | Providing and fixing factory made Single / Double leaf Partially insulated metal fire rated door set of FD 120 Pl classification with 120 minutes integrity and 30 minutes insulation as per lS 3614:2021 consisting of galvanized iron steel frame and Single / Double leaf shutter including necessary hardwareaccessories, conforming to FD 120 Pl classification of lS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick Gl Sheet with minimum 120 GSM Zinc coating as per lS: 277. The entire fire rated door set assembly shall be tested in latched condition as per lS 17518 (Part -l) 2022. The recommended fire doors shall have type test report from NABL certified lab. Proper label confirming the type of door and the hourly rating shall be mandatory. Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self-tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per lS 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonry/concrete wall opening with CSK/Hex/Any other headed fastener of minimum 8 mm dia size and minimum 80mm long with 8mm dia Polyamide sleeves @ 5 numbers at each on vertical sides and 2 numbers on horizontal top side. Door shutter: The double skinned single leaf partially insulated fire rated door shutters shall be consisting of minimum 50 mm thick and having box like structure, slots cut and holes punched, for fixing of hardware’s with stiffeners as per lS: 16074 including resin bonded mineral wool / ceramic wool infill material of minimum density 96 kg/cum. Door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size l3x2 mm to be fixed all around the glass on both the sides/ as per manufacturer arrangement. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaf. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935:2002 or butt hinges as per lS 12817, of minimum size 100x75x3 mm @ 5 numbers hinges up to 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. Hardware Accessories: Mortise / dead lock, a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt / concealed tower bolt etc. One/Two (Single/Double leaf) number heavy duty door closer of size EN 3-5 with standard arm, of desired finish (suitable up to 1250 mm door width) conforming to lS 3564/EN 1154.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per lS:13871 of approved colour and shade all complete as per manufacturer specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled with PCC 1:2:4/ cement grout after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer.Complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 24 | Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer of with necessary accessories and screws etc. in wooden doors /steel doors with necessary bolts & nuts complete as per specifications and as directed by the Engineer-in-charge. |
| 25 | Provding and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable woodenblocks inside at required places for fixing of fittings and polyurethane foam {PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 26 | Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealant etc. (fittings glazing and panelling shall be paid for separately). Anodised Aluminium sections (Minimum anodizing thickness of 15 micron) |
| 27 | Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) With clear float glass panes of 6.0 mm thickness |
| 28 | Providing and fixing of 4 mm thick approved shade Aluminium CompositeMetal Panel cladding at different locations including soffits of over-hangs butexcluding aluminium frame work with grids filled in with weather silicon sealant as per thedrawings. The ACM panel composition shall be of 0.5 mm thick PVDF coated aluminium sheet +3 mm thick low density polyethylene virgin resin core + 0.5 mm thick polyester (PVDF) coated Aluminium sheet all complete as per approved shop drawings and specification (Aluminium frame work will be paid under relevant item)Note : ACMP shall be measured to the actual visible area of the ACP sheet including silicon joints as fixed on site |
| 29 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8 mm dia. G.l plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified (2 mm thick flat) |
| 30 | Providing and fixing stainless steel aldrops of size 300 X 14 mm of approved make withnecessary screws, bolting from rear side complete as per specifications complete. |
| 31 | Providing and fixing 4 Lever Mortice Lock of approved make suitable for aluminium sections |
| 32 | Providing and fixing pair of stainless steel \\"C\\" type door handles 10 mm dia, 250 mm long SS304 grade solid rod , of specified size in steel doors/ wooden doors including screws / bolts etc.all as per drawings and specifications complete |
| 33 | Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m. including injecting cement slurry .This layer will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound @ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofing compound conforming to relevant IS and approved by Engineer-in-charge including mixing 'RECRON 3S' fibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slurry in bottom and all the sides of sunken portion. complete as directed by the Engineer-in-charge. The treatment to be tested for water tightness before filling the sunken areas. |
| 34 | Providing and Laying cement concrete 1:2:4 in super structure (1 cement, 2 crushed sand, 4 brick aggregates 20 mm to 40 mm) for filling sunken floors of toilet bath & kitchen admixed with proprietary water proofing compound as per manufacturer's specifications and approved by Engineer-in-charge including scaffolding, consolidation, finishing curing etc |
| 35 | Providing 15 mm thick plastering using Ready mix internal plastering compound for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding, Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) complete all as per specifications and as directed at site by the Engineer-in-charge |
| 36 | Providing 20 mm thick plastering using Ready mix external plastering compound for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary,including Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) and as directed by the Engineer-in-charge |
| 37 | Extra for Plastering exterior walls of height more than 10 m from ground level for every additionalheight of 3 m or part thereof |
| 38 | Providing 6mm thick plastering using ready mix plaster on cement concrete or Reinforced cement concrete work with white cement based polymer modified self curing mortar as per direction of Engineer-In-charge. |
| 39 | Providing U3 finish for RCC Surfaces rendering smooth top of the suspended floors ,landings and staircases (treads and risers), walls, slab soffits etc. including grinding / carborandum stone for repairing surface defects in areas where forms are removed, ridges at form joints, honey-combed areas, damage resulting from the stripping of forms and bolt holes including chipping / tooling of bulges and ridges, rubbing, cleaning, necessary scaffolding / staging etc. with C.M 1:2 (using Crushed sand) including a floating coat of neat cement and protecting the surface subsequent to cleaning all as per specifications and as directed by the Engineer-in-charge at all levels |
| 40 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives including scaffolding, preparation of the surfaces, etc. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm |
| 41 | Providing and Painting with 1st quality acrylic emulsion paint with Two coats on new work of required shade and colour, including scaffolding, preparation of the surfaces, etc., including a coat of approved cement primer as per manufacturer's specifications and as directed by the Engineer-in-charge. |
| 42 | Providing and applying white cement based wall putty over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge |
| 43 | Providing and Painting with Epoxy paint (two or more coats) using approved finishing coat at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer, preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, filling the holes, joint, cracks if any , scaffolding etc complete as per manufacturers Technical Data and as directed at site to achieve 250 micron Dry film thickness ( 50 Micron Primer coat and 200 micron finishing Coat) (Contractor has to provide Elcometer sampling sheets etc of his cost for testing film thickness) |
| 44 | Providing and Painting with Epoxy paint (two or more coats) ON WALLS & CEILINGS using approved finishing coat at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer , preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water , after first coat Epoxy based trowelling compound if required , including preparation of the surface by scrapping, applying sand paper, filling the holes, joint, cracks if any , scaffolding etc complete. All as per manufacturers Technical Data and as directed at site ( Contractor has to provide Elcometer sampling sheets etc at his cost for testing film thickness) On Concrete surfaces 500 micron total film thickness ( High build epoxy) |
| 45 | Providing and applying two part food grade polyamide cured solvent less epoxy lining in two coats of minimum 400 micron DFT over dry, clean and dust free surafe of water reating structures. This coat shall be applied by airless spray technique or suitable method and as per specifications & drawings. |
| 46 | Providing and fixing Indian water closet (Orissa pan) with 100 mm China ware P or S trap, One no. 10 litre High level or low level white PVC flushing cistern with flush pipe & bend with manually controlled device (handle lever) conforming to IS:7231, PVC 15 mm Inlet connection with all fittings and fixtures complete including all connection, embedding in position commissioning, cleaning etc. all as per drawings and specifications and as directed by the Engineer-in-charge. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm |
| 47 | Providing and fixing E.W.C. pan in White colour with 'P' or 'S' Trap with ISI marked white solid plastic seat and lid , 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, flush bend, fixing EWC with C.P brass screws, 15 mm PVC heavy quality inlet connection of 450 mm long, including testing , commissioning & cleaning etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge E.W.C. pan in White colour with ISI marked white solid plastic seat and lid. |
| 48 | Providing and fixing White vitreous China counter top / counter below wash basin size 560 x 410 mm / 560 x 450 mm with single 15 mm C.P. brass pillar tap (OVAL / ROUND Models) C.I. brackets,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge. |
| 49 | Providing and fixing white vitreous (Single half stall urinal with C.P brass Flush valve). china flat back half stall urinal size 580 x 380 x350 mm / 610 mm , 32mm C.P flush valve with standard flush pipe and C.P. brass spreaders, 32mm urinal waste coupling with dome grating and clamp etc. including making G.I water line connection complete as directed by the Engineer-incharge (Only G.I. pipes will be paid under relevant Item ). Note : For fixing flush valve 32 mm G.I water line provision to be made which will be paid underrelevant Item . |
| 50 | Providing and fixing Heavy quality flexible PVC waste pipe of 32 mm dia flexible (semi-rigid) for sink or wash basin including PVC waste fittings etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 51 | Providing and fixing 6 mm thick mirrors with bevelled edges complete with 6 mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers including providing and fixing mirrors with approved stainless steel 304 grade STUDS (with wall spacers) complete. all as per specifications and as directed by the Engineer-in-charge |
| 52 | Providing and fixing C.P brass towel rail 600 mm long complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-incharge |
| 53 | Providing and fixing 15 mm PVC inlet connection suitable for hot and cold water 600 mm long with nuts and washers complete for wash basins/ Urinals etc. with all necessary accessories complete as directed by the Engineer-in-charg |
| 54 | Providing and fixing heavy quality health faucet with 1.50 metres long flexible hose (hand shower) with wall brackets and type as per specifications and as directed by the Engineer-in-charge |
| 55 | Providing and Fixing CP brass 100 mm dia shower rose with Shower arm as per specifications and as directed by Engineer-in-charge complete |
| 56 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap |
| 57 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 58 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. Pipes with C-Class pipes |
| 59 | 15 mm dia G.I pipe |
| 60 | 20 mm dia G.I pipe |
| 61 | 25 mm dia G.I pipe |
| 62 | 32 mm dia G.I pipe |
| 63 | 40 mm dia G.I pipe |
| 64 | 50 mm dia G.I pipe |
| 65 | Providing and fixing C.P brass concealed stop cock of Heavy Quality of specified / approvedmake as per specifications and as directed by the Engineer-in-charge15 mm dia |
| 66 | Providing and fixing C.P brass bib cock of heavy quality as per specifications and as directed by the Engineer-in-charge 15 mm dia bib cock |
| 67 | 15 mm dia bib cock |
| 68 | 15 mm Dia LONG BODY bib cock |
| 69 | Providing and fixing 15 mm C.P brass 2 in 1 bib cock and Angle cock combinat ion of Heavy Quality of approved make as per specifications and as directe d by the Engineer-in-charge |
| 70 | Providing and fixing C.P brass Angle cock of heavy quality of specified, for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge 15 mm n.b CP brass Angle cock. |
| 71 | Providing and fixing square mouth (150 x 100 mm size gully trap \\"P\\" type) S.W. gully trap complete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design. |
| 72 | Supplying and fixing Cast Iron Man hole or Cast Iron Steps or CI cover and weight as specified in the drawings or as directed by the Engineer in charge |
| 73 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipes including required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilation pipes conforming to IS.3989 including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site |
| 74 | 75 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint |
| 75 | 100 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kg lead / joint |
| 76 | Providing, supplying, fixing in position in walls Rain water down take pipes using Centrifugally cast iron pipes (3.00 metres long) including required specials like bends, shoes etc for Rain water down take pipes Confirming to IS.3989 including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. |
| 77 | 200 mm C.I . rainwater down take pipe with 1.50 Kg lead per joint (pipe as per IS 3989) |
| 78 | 150 mm C.I . rainwater down take pipe with 1.20 Kg lead per joint (pipe as per IS 3989) |
| 79 | 100 mm C.I rain water down take pipe with 1.00 kg lead / joint conforming to relevant IS |
| 80 | Providing and fixing cast iron nahani trap / floor trap of 100 mm inlet and 75 mm outlet, (weighing 5.80 Kg each), jointing with lead with the connection pipes, placing as per the drawings, embedding in cement concrete 1:2: 4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg / sq.cm pressure and fixing 1 No 125 mm dia C. P brass grating , complete all as specifications and drawings and as directed by the Engineer-in-charge |
| 81 | Providing and fixing cast iron grating for rain water down takes at roof including chipping and grouting complete all as directed by the Engineer-in-charge |
| 82 | 150 mm x 150 mm |
| 83 | 200 mm x 200mm |
| 84 | Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge |
| 85 | Extra for cutting of reinforcement in RCC, stacking the same and returning the steel scrap to the departmental stores all as per direction of Engineer-in-charge |
| 86 | Lead charges for 1st 1 KM or part thereof, by mechanical transport including loading unloading, stacking / levelling etc. Debris up to 1 km |
| 87 | Core cutting in RCC up to and including 50 mm Dia |
| 88 | Core cutting in RCC beyond 50 mm up to and including 100 mm Dia |
| 89 | Core cutting in RCC beyond 100 mm up to and including 150 mm Dia |
| 90 | Core cutting in RCC beyond 150 mm up to and including 200 mm Dia |
| 91 | Core cutting in RCC beyond 200 mm up to and including 250 mm Dia |
| 92 | Core cutting in RCC beyond 250 mm up to and including 300mm Dia |
| 93 | Cutting Cores in vertical direction from 300mm dia to 450mm dia |
| 94 | Providing and constructioning Inspection chambers of Internal size clear dimension of 900 x 600 mm in 230 thick brick masonry with cement mortar 1:4 over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed surfaces finished with a floating coat of neat cement, brick corbelling at top to provide opening of 900 X 450 mm, embedding the frame and cover with CC 1:2:4 concrete, and fixing cast iron steps if necessary at 300mm intervals complete . Depth of chamber not exceeding 900 mm. (excavation, soling, cast iron cover and C.I steps will be paid separately under relevant item) |
| 95 | Extra depth over initial depth of 900 mm for chambers of 900 x 600 mm internal size. Including fixing cast iron steps (C.I steps shall be paid under relevant item) |
| 96 | Providing and Fixing Anchor Fastener including drilling in concrete as per requirement for fixing Eps or other structures all as specified by the manufacturer complete all as per specifications and drawings. |
| 97 | 16 mm diameter 75 mm Long |
| 98 | 16 mm diameter 100 mm Long |
| 99 | 16 MM diameter 150 mm Long |
| 100 | 16 MM diameter 200 mm Long |
| 101 | 20 mm diameter 100 mm long |
| 102 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge |
| 103 | 15 mm nb |
| 104 | 20mm nb |
| 105 | 25mm nb |
| 106 | 32mm nb |
| 107 | 40 mm nb |
| 108 | 50 mm nb |
| 109 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms |
| 110 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : |
| 111 | 50 mm nominal bore Horizontal |
| 112 | 50 mm nominal bore vertical |
| 113 | Providing and fixing in position Stainless steel Grade 304 plate-1.0 mmthick as per design for expansion joints upto 300 mm |
| 114 | Note for item 87-89The joint cover assembly system comprises of: (i) Elastomeric joint system : shall be made of extruded polyvinyl chloride or approved equivalent material with shore \\"A\\" hardness of 55+5 with UV stabiliser including provision of multi-cellular profile able to transfer loads to adjacent aluminium extrusions. The profile shall be flexible and exhibit a non-slip exposed surface that remains flat during all phases of movement (ii) Aluminium frame members : shall be made out of extruded aluminium sections conforming to ASTM B221. The alloy shall be 6061-T6 or 6063-T5 or H1200 or approved equivalent. The exposed surface shall be mill finished. (iii) Cover Plates, (iv) Self centering / turn bar arrangement : shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions so as to accommodate multi-directional seismic movement without causing stress to joint components. The centre plate shall remain flush during thermal movement and during seismic movement, the centre plate shall displace temporarily and slide over the floor. (v) Sealants : shall be a one part polysulphide base synthetic rubber / silicon sealant The item shall include for providing secondary seal /visual seal /functional vinyl seal, lubricant adhesive as required at the back for full seismic movement for specific structural gap, fixing to RCC frame work / MS structures / Masonry walls using approved anchor fasteners /sealants on either side of seismic / separation joint. The entire system shall be fully gasketed to eliminate transition rattle, including providing & applying silicone sealant between the joint and abutting the substrate, grouting, scaffolding / staging for all heights, leads & levels etc. all complete as per approved shop drawings, manufacturer's specifications and as directed by the Engineer. The item shall include for repairing & profiling of the existing joint line with the help of approved polymer modified mortar to be fixed in alignment and straight line as per joint design width and joint design complete. The item shall also include for providing and fixing of 1.2mm thick EPDM / PVC water barrier membrane over the joint profile with the help of special adhesive and necessary loop throughout the joint profile before fixing of the joint system to ensure water tight joints etc. complete. The work shall be carried out as per site conditions. |
| 115 | Designing supplying and installing proprietary roof to wall expansion / separation / seismic joint cover assembly system of approved manufacturer & comprising of With Stainless Steel Cover Plate : shall be made out of not less than 1.6 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished for 100 mm wide joint |
| 116 | Designing, supplying and installing vertical wall to wall expansion / separation / seismic joint cover assembly system of approved manufacturer & comprising of With Stainless Steel Cover Plate : shall be made out of 1.6 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished upto 300 mm |
| 117 | Designing, supplying and installing proprietary horizontal floor to floor expansion / separation / seismic joint cover assembly system of approved manufacturer WIth Stainless Steel Cover Plate : shall be made out of not less than 5 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished 300 mm wide joints |
| 118 | Providing and laying in position with 150 mm thick hard murum bedding RCC hume pipe septic tank ~1800 mm diameter x 2.5 m length, excluding excavation but inclusive of placing in position, commissioning etc. complete with all pipes vents etc. with connections on both sides. |
| 119 | Supply and Installation of pregalvanised GI sheet steel enclosure box fabricated out of 1.6 mm thick, suitable for concealed installation in Masonry wall, all sides knockout holes, two no's 10 mm nut holes for earthing, fabrication with grinding and arc spot welding, required number of knock out holes, etc. suitable for following Incomer and Outgoing feeders as per drawing, specifications & as per relevant IS, SLD, Technical specification & as per instructions of Engineer-in-charge. |
| 120 | An Enclosure box suitable for DB having14 way having 1 no. main incomer of 100 A TPN MCB with 3 no. 100 A, DP, RCBO (100mA) as incomer for each phase and 42 nos. outgoing of 16A SPN MCB |
| 121 | Supply |
| 122 | Installation |
| 123 | An Enclosure box suitable for DB having 12 way having 1 no. main incomer of 80 A TPN MCB with 3 no. 80 A, DP, RCBO (100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB |
| 124 | Supply |
| 125 | Installation |
| 126 | An Enclosure box suitable for DB having 12 way having 1 no. main incomer of 40 A TPN MCB with 3 no. 40 A, DP, RCBO (100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB |
| 127 | Supply |
| 128 | Installation |
| 129 | An Enclosure box suitable for DB having 8 way having 1 no. main incomer of 40 A TPN MCB with 3 no. 40 A, DP, RCBO (100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB |
| 130 | Supply |
| 131 | Installation |
| 132 | An Enclosure box suitable for DB having 8 way having 1 no. main incomer of 25 A TPN MCB with 3 no. 25 A, DP, RCBO (100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB |
| 133 | Supply |
| 134 | Installation |
| 135 | An Enclosure box suitable for DB having 6 way having 1 no. main incomer of 40 A TPN MCB with 3 no. 40 A, DP, RCBO (100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB |
| 136 | Supply |
| 137 | Installation |
| 138 | An Enclosure box suitable for DB having 6 way having 1 no. main incomer of 25 A TPN MCB with 3 no. 25 A, DP, RCBO (100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB |
| 139 | Supply |
| 140 | Installation |
| 141 | An Enclosure box suitable for DB having 4 way having 1 no. main incomer of 25 A TPN MCB with 3 no. 25 A, DP, RCBO (100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB |
| 142 | Supply |
| 143 | Installation |
| 144 | Supply and Installation of pregalvanised GI sheet steel enclosure box fabricated out of 1.6 mm thick, suitable for concealed installation in Masonry wall, all sides knockout holes, two no's 10 mm nut holes for earthing, fabrication with grinding and arc spot welding, required number of knock out holes, etc. suitable for following Incomer and Outgoing feeders as per drawing, specifications & as per relevant IS, SLD, Technical specification & as per instructions of Engineer-in-charge. |
| 145 | An Enclosure box suitable for DB having Incomer- 1 No 63A DP MCB & Outgoing- 12 nos 16A SPN MCB DB |
| 146 | An Enclosure box suitable for DB having Incomer- 1 No 25A DP MCB & Outgoing- 12 nos 16A SPN MCB DB |
| 147 | An Enclosure box suitable for DB having Incomer- 1 No 25A DP RCBO & Outgoing- 8 nos 16A SPN MCB DB |
| 148 | An Enclosure box suitable for DB having Incomer- 1 No 25A DP MCB & Outgoing- 8 nos 16A SPN MCB DB |
| 149 | An Enclosure box suitable for DB having Incomer- 1 No 40A DP MCB & Outgoing- 8 nos 16A SPN MCB DB |
| 150 | An Enclosure box suitable for DB having Incomer- 1 No 16A DP MCB & Outgoing- 6 nos 16A SPN MCB DB |
| 151 | An Enclosure box suitable for DB having Incomer- 1 No 25A DP MCB & Outgoing- 4 nos 16A SPN MCB DB |
| 152 | Supply and Installation of following size pre-galvanized GI sheet steel enclosure box for concealed installation of domestic switch/ sockets. The enclosure shall be fabricated out of 1.2 mm thick steel, suitable for concealed installation in Masonry wall, all sides knockout holes of 26mm, one nos of earthing arrangement, provision for installation of standard Polycarbonate face plate on top etc. as per technical specifications & instruction of Engineer-in-charge complete with all accessories. |
| 153 | Supply of 2 Modular enclosure box |
| 154 | Installation of 2 Modular enclosure box |
| 155 | Supply of 3 Modular enclosure box |
| 156 | Installation of 3 Modular enclosure box |
| 157 | Supply of 4 Modular enclosure box |
| 158 | Installation of 4 Modular enclosure box |
| 159 | Supply of 6 Modular enclosure box |
| 160 | Installation of 6 Modular enclosure box |
| 161 | Supply of 12 Modular enclosure box |
| 162 | Installation of 12 Modular enclosure box |
| 163 | Supply and embedment of 16 SWG black enameled heavy duty rigid mild steel (MS) ERW conduit pipe of following sizes along with all accessories such as bends, junction box, socket, check nut etc. including making threads, removing burrs, making chasis in wall, connection of accessories, drawing of fish wire, laying in RCC slab, beam, wall, cutting & laying in brick wall etc. as required under the instruction of engineer- in charge. Deep junction box of min. 75mm deep shall be provided. |
| 164 | 25mm MS conduit pipe |
| 165 | 40mm MS conduit pipe |
| 166 | Supply of ETP grade 14 SWG annealed tinned solid copper conductor confirming IS 8130 along with copper clip as per tender technical specifications. |
| 167 | Laying of 14 SWG tinned solid copper conductor throughout along the conduit including fixing with copper clip at every 600mm for mounting on 25mm conduit, brazing of conductor etc as required. |
| 168 | Supply and embedment of copper earth plate/ pad of size 40mm wide x 6mm thick x 550 mm long having 10nos. Of 10mm dia tapped hole for outgoing connections and 11mm dia rod on back side for brazing of 2nos. 95 Sq.mm copper conductor including brazing, connection with suitable hardwares such as brass bolt, mounting arrangement etc. The pad shall be brazed with 2nos. 95 Sq.mm copper conductor connection with suitable hardwares etc. as required |
| 169 | Supply and Installation of Heavy Duty Class-C GI pipe of following size to be laid in brick wall for laying cables. |
| 170 | 100NB |
| 171 | Electrification Quantity |
| 172 | Supply of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 173 | Supply of 16 way MCB DB having 1 no. main incomer of 63A TPN MCB, Isc=10kA, Type C with 3 nos. of 63A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 174 | Supply of 14 way MCB DB having 1 no. main incomer of 100A TPN MCB, Isc=10kA, Type C with 3 nos. of 100A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 42 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 175 | Supply of 12 way MCB DB having 1 no. main incomer of 80A TPN MCB, Isc=10kA, Type C with 3 nos. of 80A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 176 | Supply of 12 way MCB DB having 1 no. main incomer of 63A TPN MCB, Isc=10kA, Type C with 3 nos. of 63A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 177 | Supply of 12 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. of 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 178 | Supply of 8 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. of 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 179 | Supply of 8 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 180 | Supply of 6 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 181 | Supply of 6 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 182 | Supply of 4 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 183 | Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 184 | Installation, Testing and Commissioning of 16 way MCB DB having 1 no. main incomer of 63A TPN MCB, Isc=10kA, Type C with 3 nos. of 63A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 48 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 185 | Installation, Testing and Commissioning of 14 way MCB DB having 1 no. main incomer of 100A TPN MCB, Isc=10kA, Type C with 3 nos. of 100A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 42 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 186 | Installation, Testing and Commissioning of 12 way MCB DB having 1 no. main incomer of 80A TPN MCB, Isc=10kA, Type C with 3 nos. of 80A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 187 | Installation, Testing and Commissioning of 12 way MCB DB having 1 no. main incomer of 63A TPN MCB, Isc=10kA, Type C with 3 nos. of 63A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 188 | Installation, Testing and Commissioning of 12 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. of 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 36 nos. outgoing of 16A SPN MCB suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 189 | Installation, Testing and Commissioning of 8 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. of 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 190 | Installation, Testing and Commissioning of 8 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 191 | Installation, Testing and Commissioning of 6 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 192 | Installation, Testing and Commissioning of 6 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 193 | Installation, Testing and Commissioning of 4 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 194 | Supply of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 195 | Supply of MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 196 | Supply of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 197 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 198 | Supply of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 199 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 200 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 201 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 4 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 202 | Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 203 | Installation, Testing and Commissioning of MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 204 | Installation, Testing and Commissioning of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, DP MCB Outgoing MCB feeder as per SLD and technical specification. |
| 205 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 206 | Installation, Testing and Commissioning of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 207 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 208 | Installation, Testing and Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 209 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 4 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 210 | Supply of following LED light fittings complete with light fitting accessories, including supply and fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specification. |
| 211 | Supply of LED Circular Recessed downlighter with a nominal system lumen output of 2000lm and a minimum system efficacy of 110lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of pressure die cast Aluminium with high effeciency PC diffuser. The total power consumption should not exceed 18W (including driver). |
| 212 | Supply of LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 4200 lumens and a minimum system efficacy of 120lm/W. The luminaire should have a CCT of 6500K, CRI>80, UGR<22% and SDCM<=5. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of powder coated metallic CRCA with high effeciency PMMA diffuser. The total power consumption should not exceed 35W (including driver). |
| 213 | Supply of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver). |
| 214 | Supply of LED street light fitting of not more than 35W having System Efficacy >120lm/W, system output >=4200 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 5700K, SDCM<5, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Luminaire shall sustain 325V/440V stress voltage protection for 8Hrs, HV cutoff: 325V/440V. Driver shall have 4KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 215 | Supply of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 216 | Supply of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 217 | Supply of LED integral driver Flood light with a nominal system lumen output of 18000 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 150W (including driver). |
| 218 | Supply of LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 3600 lumens and a minimum system efficacy of 120lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of powder coated metallic CRCA with high effeciency PMMA diffuser. The total power consumption should not exceed 30W (including driver). |
| 219 | Supply of 6.5W, 240V, 50Hz, flame proof industrial bulkhead LED luminaire suitable for wall mounting complete with heat resistant glass cover, wire guard, wiring terminals etc. |
| 220 | Supply of 4ft Functional Batten (approx. dim. 140mmx105mmx1219mm) with 2x36W LED Tube (Flameproof) with a nominal system lumen output of 8640 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD<10% and PF>0.95 (including BIS compliant integrated driver) and other requirements shall be as per tender technical specifications. The mounting shall be ceiling suspende with Hot dipped GI rod, SS srew, Anchoe Fastener etc. and including all accessories for complete installation. |
| 221 | Supply of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 222 | Supply of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens per tube and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver). |
| 223 | Installation, Testing and Commissioning of following LED light fittings complete with light fitting accessories, including supply and fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specifiction. |
| 224 | Installation, Testing and Commissioning of LED Circular Recessed downlighter with a nominal system lumen output of 2000lm and a minimum system efficacy of 110lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of pressure die cast Aluminium with high effeciency PC diffuser. The total power consumption should not exceed 18W (including driver). |
| 225 | Installation, Testing and Commissioning of LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 4200 lumens and a minimum system efficacy of 120lm/W. The luminaire should have a CCT of 6500K, CRI>80, UGR<22% and SDCM<=5. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of powder coated metallic CRCA with high effeciency PMMA diffuser. The total power consumption should not exceed 35W (including driver). |
| 226 | Installation, Testing and Commissioning of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver). |
| 227 | Installation, Testing and Commissioning of LED street light fitting of not more than 35W having System Efficacy >120lm/W, system output >=4200 Lumens, THD<10%, Power Factor >=0.95, CRI >70, CCT 5700K, SDCM<5, IP66 protected pressure die cast aluminium housing having PC diffuser with IK08.The luminaire shall be supplied with pipe of suitable dia for mounting of the same. Luminaire shall sustain 325V/440V stress voltage protection for 8Hrs, HV cutoff: 325V/440V. Driver shall have 4KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 228 | Installation, Testing and Commissioning of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 229 | Installation, Testing and Commissioning of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 230 | Installation, Testing and Commissioning of LED integral driver Flood light with a nominal system lumen output of 18000 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 150W (including driver). |
| 231 | Installation, Testing and Commissioning of LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 3600 lumens and a minimum system efficacy of 120lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of powder coated metallic CRCA with high effeciency PMMA diffuser. The total power consumption should not exceed 30W (including driver). |
| 232 | Installation, Testing and Commissioning of 6.5W, 240V, 50Hz, flame proof industrial bulkhead LED luminaire suitable for wall mounting complete with heat resistant glass cover, wire guard, wiring terminals etc. |
| 233 | Installation, Testing and Commissioning of 4ft Functional Batten (approx. dim. 140mmx105mmx1219mm) with 2x36W LED Tube (Flameproof) with a nominal system lumen output of 8640 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD<10% and PF>0.95 (including BIS compliant integrated driver) and other requirements shall be as per tender technical specifications. The mounting shall be ceiling suspende with Hot dipped GI rod, SS srew, Anchoe Fastener etc. and including all accessories for complete installation. |
| 234 | Installation, Testing and Commissioning of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 235 | Installation, Testing and Commissioning of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W per tube. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver). |
| 236 | Supply of the following modular switches and plug sockets in the existing recess mounted GI box as per technical specification. |
| 237 | Supply of 4 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 4nos. Of plug tops and suitable mounting arrangements as per technical specification. |
| 238 | Supply of 2 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 2nos. Of plug tops and suitable mounting arrangements as per technical specification. |
| 239 | Supply of 1 nos. of 6A, Single phase Modular socket with 6A switch for socket and heavy duty Polycarbonate face plate, 1no. Of plug top and suitable mounting arrangements as per technical specification. |
| 240 | Installation, Testing and Commissioning of the following modular switches and plug sockets in the existing recess mounted GI box as per technical specification. |
| 241 | Installation, Testing and Commissioning of 4 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 4nos. Of plug tops and suitable mounting arrangements as per technical specification. |
| 242 | Installation, Testing and Commissioning of 2 nos. of 6A/16A (compatible with both 6A and 16A), Single phase Modular type socket with 16A switch for each socket and heavy duty Polycarbonate face plate, 2nos. Of plug tops and suitable mounting arrangements as per technical specification. |
| 243 | Installation, Testing and Commissioning of 1 nos. of 6A, Single phase Modular socket with 6A switch for socket and heavy duty Polycarbonate face plate, 1no. Of plug top and suitable mounting arrangements as per technical specification. |
| 244 | Supply of the following Modular switches in the existing recess mounted GI box as per Technical specifications. |
| 245 | Supply of 2 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 246 | Supply of 4 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 247 | Installation, Testing and Commissioning of the following Modular switches in the existing recess mounted GI box as per Technical specifications. |
| 248 | Installation, Testing and Commissioning of 2 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 249 | Installation, Testing and Commissioning of 4 nos. of 6A, Single Pole, Modular Switch with heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. |
| 250 | Supply of switch box set consisting of 2nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 251 | Installation, Testing and Commissioning of switch box set consistingof 2nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 252 | Supply of switch box set consisting of 4nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 253 | Installation, Testing and Commissioning of switch box set consisting of 4nos. of 6A, Single Pole, Modular switch with polycarbonate box, heavy duty polycarbonate face plate suitable for surface mounting provided with mounting arrangements as per Technical specification. |
| 254 | Supply of 4nos. of 6A/16A single phase Modular socket (compatible with both 6A and 16A) with polycarbonate box, 16A switch for each socket and heavy duty polycarbonate face plate, plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 255 | Installation, Testing and Commissioning of 4nos. of 6A/16A single phase Modular socket (compatible with both 6A and 16A) with polycarbonate box, 16A switch for each socket and heavy duty polycarbonate face plate, plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 256 | Supply of 2nos. of 6A/ 16A (compatible with both 6A and 16A) single phase Modular socket with polycarbonate/GI box as required, 16A switch for each socket and heavy duty polycarbonate face plate, 2 nos of 16A plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 257 | Installation, Testing and Commissioning of 2nos. of 6A/ 16A (compatible with both 6A and 16A) single phase Modular socket with polycarbonate/GI box as required, 16A switch for each socket and heavy duty polycarbonate face plate, 2 nos of 16A plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 258 | Supply of 1nos. of 6A , single phase Modular socket with polycarbonate box, 6A switch for socket and heavy duty polycarbonate face plate, plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 259 | Installation, Testing and Commissioning of 1nos. of 6A, single phase Modular socket with polycarbonate box, 6A and switch for socket and heavy duty polycarbonate face plate, plug tops, suitable for surface mounting, provided with mounting arrangement as per technical specification. |
| 260 | Supply and embedment of heavy duty hot dipped GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Surfacr mounted Junction box of suitable size as required suit at site shall be provided. |
| 261 | Supply of 25mm GI conduit |
| 262 | Supply of 40mm GI conduit |
| 263 | Fixing by surface conduiting of 16SWG heavy duty Class-B Galvanised steel (G.I.) ERW conduit pipe of following sizes along with all accessories such as inspection bends, junction box, socket, check nut, etc. including making threads, removing burrs, connection of accessories, cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structural, etc. as required under the instruction of Engineer-in-incharge. Surface type junction box shall be provided. |
| 264 | Installation of 25mm GI conduit |
| 265 | Installation of 40mm GI conduit |
| 266 | Supply of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 267 | Supply of flexible GI conduit pipe of size 26 MM |
| 268 | Supply of flexible GI conduit pipe of size 50 MM |
| 269 | Installation of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 270 | Installation of flexible GI conduit pipe of size 26 MM |
| 271 | Installation of flexible GI conduit pipe of size 50 MM |
| 272 | Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification |
| 273 | Supply of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 274 | Supply of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 275 | Installation/drawing through concealed/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 as per conductor class 2 of IS:8130/1984 as per technical specification. |
| 276 | Installation/drawing of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 277 | Installation/drawing of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 278 | Junction box/Cable pull box of size 100mm x 100mm x 50mm fabricated out of 2mm thick GI sheet, cable gland plate at the bottom, punched hole for conduit entry on all sides, suitable to terminate 2nos. of 3 core x 2.5 Sq.mm Cu conductor, 8 nos. of terminals, etc. as required. |
| 279 | Supply of Junction box/Cable pull box of size 100mm x 100mm x 50mm |
| 280 | Installation of Junction box/Cable pull box of size 100mm x 100mm x 50mm |
| 281 | Supply, Fabrication and Installation of Standard steel sections as per IS 2062 Grade BR for light frame, base frame, wall frames, brackets for supporting equipments and cable tray supports, clamps for GI rods etc. including all accessoriessuch as 8/12mm anchor fastner, SS screw, bolts etc. Fabrication shall include drilling, entiling, welding by qualified welder, wire brush cleaning, testing DPT etc., supply of all consumables like gas, approved welding rods as per EIC and tender tech spec. After fabrication two coats of epoxy based primer and two coats of finish paints shall be applied. |
| 282 | Supply and laying of 95 sq. mm Class-2 stranded bare tinned copper conductor underground upto depth of 1 meter, including excavation, connection with earth pit at one end and connection with test link box at other end, including clamping, connection through brazing/ bolting , refilling the trench etc. as per instructions by Engineer-In-Charge. Brazing is considered as separate item in this tender. |
| 283 | Supply of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 284 | Installation of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 285 | Supply and surface/concealed laying of 95 sq. mm stranded tinned coper conductor, including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. Brazing is considered as separate item in this tender. |
| 286 | Supply of 95 sq. mm stranded tinned coper conductor |
| 287 | Installation of 95 sq. mm stranded tinned coper conductor |
| 288 | Supply and surface/concealed laying including making chasing on wall of 10 sq. mm stranded tinned coper conductor, connection with earth pad at one end and DBs/ sockets/ motor at other end including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 289 | Supply of 10 sq. mm stranded tinned coper conductor |
| 290 | Installation of 10 sq. mm stranded tinned coper conductor |
| 291 | Supply and surface/concealed laying of 2 x 10 sq. mm Cu PVC insulated earthing conductor in 25mm HDPE pipe including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 292 | Supply |
| 293 | Installation |
| 294 | Supply of 25mm HDPE pipe as per tender specifications. |
| 295 | Supply and installation of tinned Cu Lugs and Brass bolt suitable to following sizes of earthing conductors as per attached technical specification |
| 296 | 95 Sq.mm stranded tinned copper conductor |
| 297 | 10 Sq.mm stranded tinned copper conductor |
| 298 | Supply and installation of M10 brass bolt, 3/4\\" long suitable for 10mm threaded hole for making connection to earth pad. |
| 299 | Supply and installation of test link box for earth pit connection and interconnection of down conductor from lightning protection system to lightning earth pit and should consist of 2mm thick powder coated pre-galvanised G.I. weather proof sheet enclosure with cover, having 50mm x 4mm copper strip link, teflon sealing after connection, earthing stud, etc as required. |
| 300 | Supply of test link box |
| 301 | Installation & Testing of test link box |
| 302 | Supply and installation of test link box for earth pit connection and interconnection of down conductor from lightning protection system to lightning earth pit and should consist of 2mm thick powder coated pre-galvanised G.I. weather proof sheet enclosure with cover, having 25mm x 3mm copper strip link, teflon sealing after connection, earthing stud, etc as required. |
| 303 | Supply of test link box |
| 304 | Installation & Testing of test link box |
| 305 | Supply of Busbar Insulator of size M8 x 40mm, MOC: Epoxy as per tender specification. |
| 306 | Installation of Busbar Insulator of size M8 x 40mm for fixing of downcomer conductor from lightening arrestor as per tender specification. |
| 307 | Supply and Installation of 25 mm X 3 mm thick copper strip including connection/ terminating with nut, bolt, spring, washer etc. as required. |
| 308 | Supply of 25 mm X 3 mm thick copper strip |
| 309 | Installation & Testing of 25 mm X 3 mm thick copper strip |
| 310 | Supply and fixing vertical air termination made up of 20mm dia, 1mtr long copper rod attached to 145mm dia Copper sphere having drilled and tapped holes for fixing 5nos. Of 390mm long spikes and square copper base plate of 150mm length and 10mm thickness as per technical specification and approved drawing. |
| 311 | Supply of vertical air termination |
| 312 | Installation of vertical air termination |
| 313 | Prefabricted GI box to accomodate modular type 2 Nos. of RJ11 socket unit suitable for concealing or surface mounting. |
| 314 | Supply of Prefabricted GI box |
| 315 | Installation of Prefabricted GI box |
| 316 | Front plate of modular type (M.O.C: Polycarbonate) to accommodate 2 Nos. of RJ11 socket unit. |
| 317 | Supply of Front plate |
| 318 | Installation of Front plate |
| 319 | Supply, Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor with inbuilt or external power pack and auxiliary relay having min 15mtr sensing range in 180deg orientation and time delay ranges from 30sec to 30min and should have output relay capacity of 1000W (for LED lighting fixtures). |
| 320 | Supply of Ceiling mounted dual type occupency sensor |
| 321 | Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor |
| 322 | Supply, Installation, Testing and Commissioning of Occupancy sensor bypass switch box having 3pole rotary switch fixed on GI enclosure with cover. |
| 323 | Supply of Occupancy sensor bypass switch box |
| 324 | Installation, Testing and Commissioning of Occupancy sensor bypass switch box |
| 325 | Supply and installation of following exothermal welding joints including all accessories such as Graphite Mould, Mould handle clamp, steel metal disk, exothermal weld powder, ignite powder, flint gun, brush, sealing compound, flame torch, safety equipments and all required tools to complete the job as per instructions by Engineer-In-charge and tender specifications. |
| 326 | Supply of required material and making of straight exothermic braze joints of copper conductors (95 sqmm) as per technical specification. |
| 327 | Supply of required material and making of 'T' type exothermic braze joints of copper conductors (95 sqmm) as per technical specification. |
| 328 | Supply and Installation of GI Anchor Fastner of size M8x80 MM by drilling through concrete block as per site requirement for fixing plate Eps or other structures as per the tender specification. |
| 329 | Supply of GI Anchor Fastner of size M8x80 MM |
| 330 | Installation of GI Anchor Fastner of size M8x80 MM |
| 331 | Supply and Installation of Copper earth pads of size 500 x 40 x 6mm including clamps suitable for surface/concealed mounting as per instructions by Engineer-In-charge and tender specifications. |
| 332 | Supply and Installation of 1.2 mm thick pre-galvanized GI sheet cover plates including marking, cutting (as per site requirement) and fixing on top of JB openings in wall and slab bottom/ ceiling at approx height of 5mtrs as per tender specifications. |
| 333 | Supply, Fabrication and Installation of Pre-Galvanized Powder Coated dome shaped cover of 1.6mm sheet thickness, 1220mm long for LED Tube light fittings as per specifications and instructions of Engineer-in-charge. |
| 334 | Supply of 1 nos. of 6A Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. The whole set shall be mounted inside a IP66 enclsoure. |
| 335 | Installation, Testing and Commissioning of 1 nos. of 6A Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. The whole set shall be mounted inside a IP66 enclsoure. |
| 336 | 2 Pair 0.6mm copper conductor Telephone cable as per tender specifications. |
| 337 | Supply |
| 338 | Installation |
| 339 | Supply of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 340 | Laying of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 341 | Supply of 1 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 342 | Laying of 1 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 343 | Supply of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor, armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 344 | Laying of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor,armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 345 | Supply of Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 100+100 pairs of Telephone cable as per the technical specification. |
| 346 | Installation, Testing and Commissioning of Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 100+100 pairs of Telephone cable as per the technical specification. |
| 347 | 50 Terminal Junction Box for PA System as per Tender specification. |
| 348 | Supply |
| 349 | Installation |
| 350 | 4 Terminal Junction Box for PA System as per Tender specification. |
| 351 | Supply |
| 352 | Installation Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail