| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , Sch No 15.56 |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm, Sch No 15.23.2 |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In lime mortar with old mughal bricks (Dismentling of Brick work), Sch No 15.7.2 |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area beyond 3 sq. metres , Sch No 15.12.2 |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below (Dismentling of door window, ventilator), Sch No 15.12.1 |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved., Sch No 15.6 |
| 7 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete, Sch No 13.88 |
| 8 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (Scrapping of existing paint), Sch No 13.91 |
| 9 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand), Sch No 14.1.2 |
| 10 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches., Sch No 2.8.1 |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Sch No 4.1.8 |
| 12 | R.C.C. work in lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete), Sch No 5.3 |
| 13 | R.C.C. work in R.C.C. Raft foundation and footing with approved stone ballast.(Using 1:1.5:3 Mix concrete), Sch No 5.1.2 |
| 14 | R.C.C. work in R.C.C. columns in 1:1.5:3 having strength not less than M-20., Sch No 5.2.2 |
| 15 | Thermo-Mechanically Treated bars of grade Fe-500D or more work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage., Sch No 5.22.6 |
| 16 | Class M-150 (Non modular) brick work in 1:6 cement and coarse sand of 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand), Sch No 6.1.2 |
| 17 | Brick work in super-structure above plinth level up to floor two level (up to five level) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand)., Sch No 6.4.2 |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand), Sch No 6.4.1 |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (c.c. moulding ), Sch No 4.1.3 |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundations, footings, bases of columns, etc. for mass concrete, Sch No 5.9.1 |
| 21 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick, Sch No 5.9.21 |
| 22 | (c) Columns, Pillars, Piers, Abutments, Posts and Struts, Sch No 5.9.6 |
| 23 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate, Sch No 11.3.1 |
| 24 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick , Sch No 11.6.1 |
| 25 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (a) 40 mm wide and 4 mm thick, Sch No 11.13.1 |
| 26 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete., Sch No 11.37A |
| 27 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), Sch No 10.15.1 |
| 28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete., Sch No 9.48.1 |
| 29 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (Gate steel work), Sch No 10.25.2 |
| 30 | Fixing of M.S. Chaukhats(a) Door chaukhats , Sch No 14.2.1 |
| 31 | Providing & fixing S.S. Sliding bolts 16 mm dia with nuts and 250 mm long , Sch No SOR-2022 CH-1,MAT-10 (g) |
| 32 | Providing & fixing Stainless steel tower bolt with 10 mm dia & 250 mm long screw, Sch No SOR-2022 CH-1,MAT-10 (d) |
| 33 | Providing & fixing Stainless steel door handles with screws 150 mm long, Sch No SOR-2022 CH-1,MAT-10 (2) |
| 34 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Single leaf., Sch No 9.21.1 |
| 35 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes, Sch No 10.30.2 |
| 36 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading., Sch No 9.7.8 |
| 37 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 12 mm thick outer plaster), Sch No 13.4.2 |
| 38 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (2.25FM) (15 mm thick inner plaster), Sch No DSR.-13.2.2 |
| 39 | 6 mm cement plaster of mix : (ceiling area), Sch No DSR.-13.16.1 |
| 40 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) , Sch No (DSR-13.44.1) |
| 41 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats (Plastic Emultion paint), Sch No D.S.R-(13.51.2) |
| 42 | Finishing wall with acrylic smooth exterior paint of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm), Sch No DSR-13.47.1 |
| 43 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre, Sch No DSR-13.41.1 |
| 44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Sch No DSR-13.80 |
| 45 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding, Sch No DSR-14.72 |
| 46 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture, Sch No D.S.R-(13.48.3) |
| 47 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture , Sch No D.S.R-(13.48.2) |
| 48 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured., Sch No 22.6 |
| 49 | P/F Murga Jali , Sch No SOR-2022 CH-1,MAT-13 (iii) |
| 50 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595 mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600 mm centre to centre in a floor and ceiling channel section of size 50 x 32 mm fixed to the floor and soffit at 600 mm centre using 12 mm dia,50 mm long wedge type expanded zinc alloy dash fastner with 10 mm bolt. This same channel is then to be fixed in (Scaffolding of building) horiziontal direction at 600 mm centre to centre so as to form a grid of 600 mm x 600 mm. Glasswool of 50 mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2 mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50 mm wide (90 m) roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineer in-Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles, Sch No 26.24.1 |
| 51 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work, Sch No SOR ELE-18, 1131 |
| 52 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper ompletionof work., Sch No SOR ELE-18, 1132 |
| 53 | PLUMBING WORK |
| 54 | SUB-HEAD I (SANITARY FIXTURES & ACCESSORIES ) |
| 55 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required : a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, Sch No 17.1.1 |
| 56 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standard pattern including cutting & making good the walls wherever required.a) Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap., Sch No 17.7.4 |
| 57 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 32mm dia, Sch No 17.28.2.1 |
| 58 | Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers., Sch No 17.31 |
| 59 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm Kitchen sink with drain board, Sch No 17.10.1.1 |
| 60 | SUB-HEAD II (SOIL WASTE & VENT PIPES AND FITTINGS ) |
| 61 | Providing & fixing soil, waste and vent pipes.a) 100mm dia centrifugally cast iron S & S pipe., Sch No 17.35.1.2 |
| 62 | b) 75mm dia centrifugally cast iron S & S pipe., Sch No 17.35.2.2 |
| 63 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.a) 100mm, Sch No 17.58.1 |
| 64 | b) 75mm, Sch No 17.58.2 |
| 65 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.a) for 100mm dia pipe., Sch No 17.37.1 |
| 66 | b) for 75mm dia pipe., Sch No 17.37.2 |
| 67 | Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors.a) 100mm inlet & 75mm outlet., Sch No 17.60.2.1 |
| 68 | Providing & fixing cast iron coller.a) 100mm dia., Sch No 17.57.1.2 |
| 69 | b) 75mm dia., Sch No 17.57.2.2 |
| 70 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.a) 110mm diameter, Sch No 12.41.2 |
| 71 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.a) 110mm diameter, Sch No 12.43.2 |
| 72 | SUB-HEAD III (WATER SUPPLY PIPES AND FITTINGS) |
| 73 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work)Exposed on walla) 25mm dia nominal bore (medium duty), Sch No 18.10.3 |
| 74 | b) 32mm dia nominal bore (medium duty), Sch No 18.10.4 |
| 75 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.a) 15mm dia nominal bore, Sch No 18.11.1 |
| 76 | b) 20mm dia nominal bore, Sch No 18.11.2 |
| 77 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.a) 15mm dia nominal bore., Sch No 18.40.1 |
| 78 | b) 20mm dia nominal bore., Sch No 18.40.2 |
| 79 | c) 25mm dia nominal bore., Sch No 18.40.3 |
| 80 | d) 32mm dia nominal bore., Sch No 18.40.4 |
| 81 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15mm nominal bore, Sch No 18.21.2.1 |
| 82 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931a) 15mm nominal bore, Sch No 18.49.1 |
| 83 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931a) 15mm nominal bore, Sch No 18.53.1 |
| 84 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats).a) 25mm. Nominal bore, Sch No 18.18.3 |
| 85 | Providing and fixing gun metal gate valve with wheel of approved quality.a) 25mm dia nominal bore, Sch No 18.17.1 |
| 86 | b) 32mm dia nominal bore, Sch No 18.17.2 |
| 87 | c) 40mm dia nominal bore, Sch No 18.17.3 |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Capacity 11000 litre, Sch No 18.48 |
| 89 | SUB-HEAD IV (SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE SYSTEM) |
| 90 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.a) Pipes 80mm to 300mm diameter., Sch No 2.10.1.2 |
| 91 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 100mm diameter, Sch No 19.1.1 |
| 92 | b) 150mm diameter, Sch No 19.1.2 |
| 93 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.a) 100mm diameter S.W. Pipe, Sch No 19.2.1 |
| 94 | b) 150mm diameter S.W. Pipe, Sch No 19.2.2 |
| 95 | Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with bricks of class M-150 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.a) 150 x 100 mm. size P type, Sch No 19.4.2.2 |
| 96 | Constructing brick masonry manhole with class bricks M-150 in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.a) Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg., Sch No 19.7.1.1 |
| 97 | ELECTRIFICATION WORK |
| 98 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C, Sch No 1.10.3 |
| 99 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required., Sch No 1.12 |
| 100 | Submains : |
| 101 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire, Sch No 1.14.1 |
| 102 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire, Sch No 1.14.3 |
| 103 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire, Sch No 1.14.9 |
| 104 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm, Sch No 1.21.1 |
| 105 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch, Sch No 1.24.1 |
| 106 | 3 pin 5/6 A socket outlet, Sch No 1.24.4 |
| 107 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required., Sch No 1.25 |
| 108 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., Sch No 1.26 |
| 109 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm), Sch No 1.27.1 |
| 110 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required., Sch No 1.31 |
| 111 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep, Sch No 1.50.1 |
| 112 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point), Sch No 1.57 |
| 113 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, Sch No 2.4.1 |
| 114 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole, Sch No 2.10.1 |
| 115 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required., Sch No 2.11 |
| 116 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A, Sch No SOR-1016 |
| 117 | Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A, Sch No SOR-1020 |
| 118 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A, Sch No 2.15.1 |
| 119 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required., Sch No 2.21 |
| 120 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required., Sch No 5.4 |
| 121 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm), Sch No 5.9 |
| 122 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required., Sch No 5.12 |
| 123 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required., Sch No 19.1 |
| 124 | Supply and fixing of Single light Wall Bracket on matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA, Sch No SOR-412 |
| 125 | Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect. CAT. - AAA, Sch No SOR-1413 |
| 126 | Supply and fixing of LED Tube Light fitting suitable for up to 2X22 Watt LED Tube Light on surface complete in all Respect. CAT. - AAA, Sch No SOR-1414 |
| 127 | Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. CAT. - AAA, Sch No SOR-1402 |
| 128 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 25 sq mm x 3-1/2core , Sch No PWD SOR-2024-20A.1.10 |
| 129 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer-incharge. for cable size 25 sq mm x 3-1/2core, Sch No SOR-503 J |
| 130 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 25 sq mm , Sch No SOR-504 |
| 131 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect., Sch No RATE APPROVED BY SE Please Enable Macros to View BoQ information |