| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 2 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/ Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)18-22 Watt |
| 3 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).200 watt |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wallsurface as required.Upto 35 sq. mm |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.Upto 35 sq. mm |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 kV grade as required.4 x 25 sq.mm (28mm) |
| 8 | 4 x 35 sq.mm (32mm) |
| 9 | Supplying of Following Items for Routine Operation and Maintenance of Electrical Panels situated at Pump House of FFC complex.3 pole MCCB, 100A, 16kA Ics= 100% Icu and operational voltage 690 V |
| 10 | 4 pole MCCB, 250A, 36kA Ics= 100% Icu and operational voltage 690 V |
| 11 | 40 A, 2 Pole Isolator |
| 12 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 13 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 14 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 15 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. 16.13.1 bituminous portion (18 mtrx0.25mtrx0.30 mtr) |
| 16 | Brick work with common burnt clay bricks of class designation 7.5 in mud mortar for Tank open entrace . |
| 17 | 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand) or Tank open entrace . |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:13.99.1 One or more coats on old work for exising panels and cable tray etc. |
| 19 | Electrician for Operation of Pump sets all days including Sundays & Holidays by providing services of qualified & experienced skilled staff as reqd. at site or as per the direction of Engineer-In-Charge. |
| 20 | Operator for Operation of Goods Lift all days including Sundays & Holidays by providing services of qualified & experienced skilled staff as reqd. at site or as per the direction of Engineer-In-Charge. |
| 21 | Supply,Installation,Testing and commissioning of 50 mm G.I.pipes with double layer FRP quoting of following size Heavy \\"C\\" class along with necessories clamps, foundation,bends ,etc as required complete in all respect. |
| 22 | Supply of Heavy duty exhaust fan 1400 RPM, 450mm, 230 Volt,50 Hz |
| 23 | Supply of PVC Tape 1.80CMX6 M. |
| 24 | Supply of 4 core X 25 Sq.mm XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 Complete with all respect |
| 25 | Supply of 4 core X 35 Sq.mm XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 Complete with all respect |
| 26 | Supply of Two Core 0.75 Sq.mm, 24/0.2 No./dia mm PVC FRLS Insulated unsheathed industrial flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts (1 Roll=100 metre) |
| 27 | Supply of PVC Wire clip 5,6,8 mm 100 pieces/packet |
| 28 | Supply of GI saddles 25mm( 100 pieces/packet) |
| 29 | Supply of 25mm PVC Flexible Conduit pipe (25 mtr) |
| 30 | Supply of electric clear bulb 100 watt, 230 Volts |
| 31 | Supply of Copper lugs for 25 sq. mm cable |
| 32 | Supply of Copper lugs for 35 sq. mm cable |
| 33 | Supply of Copper lugs lugs for 50 sq. mm cable |
| 34 | Supply of Aluminium line connectors for 35 sq. mm cable |
| 35 | Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable (1 Roll=90 metre) |
| 36 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable (1 Roll=90 metre) |
| 37 | Supply and fixing of Panel lock (M.S.) with key ,round pin type for existing Electrical panels |
| 38 | Supply and fixing of Digital VAF meter CL-1 in existing Panel |
| 39 | Supply and fixing of R Y B Indicating Lamps 230VAC for existing Panel |
| 40 | Supply of Safety Gloves For Electric Work Insulated Hand Rubber 15 KVA Electrical Hand Gloves Shockproof- complete as required at site. |
| 41 | Supply of Auto Digital Clamp Meter. Power Source-Battery Power complete as required at site. |
| 42 | Supply of TAPARIA Combination Spanner Set 12pc Wrench Chrome Vanadium, Orientation:-Double Sided, Size:-6,7,8,9,10,11,12,13,14,17,19,22 complete as required at site. |
| 43 | Supply of TAPARIA steel (165 mm) combination Electrical Plier with joint cutter complete in all respect. |
| 44 | Supply of TAPARIA Screw Driver set with bulb complete in all respect |
| 45 | Supply of Electrician Hammer with wooden handle for day to day electrical work complete in all respect |
| 46 | Supply andd fixing of Ceiling MountedABC Powder based Fire Extinguisher 5 Kg |
| 47 | Refilling and Testing of Fire Extinguisher Co2 Type Fire Extinguisher (4.5 KG Capacity) as per IS Code:2190 complete as required at site. |
| 48 | Refilling and Testing of existing ABC Type Fire Extinguisher (5 KG capacity) as per IS Code:2190 complete as required at site. |
| 49 | Cleaning of Water Tank from inside and out side surface ,tree roots,mud,dry leaves etc. . |
| 50 | Lowering and un lowering deep well Pump set in water tank as per required at site with tripod chain pulley set and cartage from site to work shop etc. rating up to 1.0/10.0 HP complete in all respect |
| 51 | Repairing & rewinding of deep well Pump set , GI pipe, GI socket three core copper cable, i/c Varnishing, Baking cutting and dismantling old brunt winding wire & Terminal plate,reassembling, re-installation, testing, commissioning, loading unloading and cartage from site to work shop etc. rating up to 1.0/10.0 HP complete in all respect |
| 52 | Dismantling and buyback item of existing old defective as above items as per schedule i.e. flood lights, cable ,M.S cable trays and three phase motors 3 nos. Please Enable Macros to View BoQ information |