Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (with out taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed. |
| 2 | Taking down chowkhats or frames with shutters (with out taking off shutters from the frame) exc 1.5 sqm but n.exc 4.00 sqm each complete all as specified and directed. |
| 3 | Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each complete all as specified and directed. |
| 4 | Taking down and refixing shutters of any description exc 1 sqm and n exc 2 sqm each in the same opening after taking down, easing and adjusting including refixing builders hardware as required and renewal of unserviceable screws complete all as specified and directed. |
| 5 | S&F for solid PVC door frame of size 50mm x 47mm made out of 5mm prelam colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications & drawings complete all as specified and directed. |
| 6 | S&F in repair for framed work as in door frames or gates chowkats of angle or other section with braces, etc., complete, drilled or welded for ms hinges for fixing of gate or doors other covering and also fastening and fixing complete all as specified and directed. |
| 7 | S&F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel designed with 2 mm thick moulded PVC sheet on front face and 4mm plain colour PVC sheet on back face as per specification and drawing complete all as specified and directed. |
| 8 | M&L for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, kiln seasoned and chemically pressed treated complete all as specified and directed by Engineer- in -Charge. |
| 9 | S&F aluminium ventilator powder coated (requried colour to match window colour), louvers type, frame top & bottom of size 31x42x1.50 mm (rectangular tub of size 40x20x2mm (and middle vertical of size 42x46.20x1.50 mm Section and clip for fixing wire mesh and glass of size 19x17.30x0.90 mm thick including stainless steel wire cloth 0.36mm nomonal dia of wire and 1.40 mm average width of aperture and fixed with stainless steel wire staples and supply and fixing 4 mm thick glass louvers with blades of 100mm heavy duty with necessary rubber beading, gasket etc complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium frame for doors, windows, ventilators & partition etc., with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 11 | S&F Powder coated (thickness of powder coating minimum 50 micron) Anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, 3 Nos hinges, tower bolts 2 Nos in each door anodised aluminum snap beading screws with fixing of glass/jalli etc. complete all as specified complete all as specified and directed.Note :- Wire cloth & Glass pane shall be measured and paid for separately. |
| 12 | S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium window and ventilator shutters, side hung without sash bars, aluminium sections weighing 0.55 kg/m & including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 No.), suitable handle (1 No), with fixing of glass/wire cloth complete all as specified and directed.Note :- Wire cloth & Glass pane shall be measured and paid for separately. |
| 13 | Supply, fabricated & fixing Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 14 | S&F in repair Aluminium (die cast ) body , Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 15 | S&F in repair Aluminium Mortice lock 4 levers, vertical type, size 100 mm for Aluminium doors complete all as specified and directed. |
| 16 | S&F 100 mm long SS butt hinges and fixed to frame with scrwewd or welding / gas welding complete all as specified and directed. |
| 17 | S&F for 150mm long aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 18 | S&F aluminium alloy anodized sliding door bolt with haps and staple (bolt type) and fixing clip of sheet cast or extruted section or cast aluminium alloy and fixed length of bolt 250 mm complete all as specified and directed by Engineer -in -Charge. |
| 19 | S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F 150mm long Floor door stopper of alunium body and tongue, with hard drawn steel spring, fixed to bottom of door shutter complete all as specified and directed. |
| 21 | Supply only 4 mm thick sheet glass ordinary quality, cut to size as required at site, complete all as specified and directed. (Cost of fixing of glass shall be deemed included in the unit rates under respective items.) |
| 22 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or teak wood beading for wooden doors etc complete all as specified and directed. |
| 23 | S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or teak wood beading for wooden doors etc complete all as specified and directed. |
| 24 | S&F Aluminium composit panel sheets as in cladding , aluminium doors and partitions etc complete all as specified and directed |
| 25 | M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 26 | M&L for painting at old wooden painted surface of any description over 10cm width or grith not otherwise described including preparation , of surface and two coats of synthetic enamel paint complete all as specified and directed. |
| 27 | Dismantling plain or corrugated steel sheeting, any gauge, any thickness incl hooks and ridge as retrieved from site complete all as specified and directed. |
| 28 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/plain steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed. |
| 29 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 30 | M&L for anodised aluminium snap grid frame work of size (605mm X 605mm ) using T grid/Cross-T/Wall angle/level clip & suspenders for false ceiling and similar works including hangers 6mm dia. G.I. wire (upto 1200 mm length) size of grid (605 mm X 605 mm ) adjusting level fixed to roof slabs/trusses by means of ceiling cleats made out of G.I.flat 40 x 3 mm size 60 mm long and expansion hold fastener 12.5mm dia 40mm long complete and supply and fix 12 mm thick gypsum tiles (600mm x 600 mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film fixed complete all as specified and as directed by Engineer-in-Charge. |
| 31 | S&F in repair false ceiling sheet size of 595*595*12 mm mineral fibre ceiling tiles complete all as specified and directed. |
| 32 | S&F Soild PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 33 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 34 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc.laid and bedded on pointed on any mortar complete all as specified and directed. |
| 35 | M&L for green marble slab 15-18 mm thick machine cut, beded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of Marble slab including moulding,cutting and polishing and nosing and polishing of the free or front edge of the slab window cills etc and including 15mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer -in -Charge. |
| 36 | Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the permises complete all as specified and directed. |
| 37 | M&L for 15 mm thick screed bed or bedding layer of morter for laying floor finishes CM 1:6 complete all as specified and directed. |
| 38 | M&L for non skid ceramic light coloured tiles 7-8mm thick (square/Rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 39 | M&L for non skid ceramic light coloured tiles 7-8mm thick (square/Rectangular) area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 40 | M&L for non- skid ceramic coloured joint free tiles 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 41 | M&L glazed ceramic coloured digital tiles 450x300mm x 7mm thick in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat of CM 1:4 10mm thick etc complete all as specified and directed. |
| 42 | M&L for machine cut kota stone slab flooring 20 - 25mm thick over cement mortar 15mm (1:6) screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including backing coat complete all as specified and directed. |
| 43 | M&L for cutting/grinding of the existing Terrazo/Marble/Kota stone flooring by mechnical process using carborundum stone of appropriate grit,cleaning and finally mirror polishing by applying wax polish complete all as specified and directed. |
| 44 | M&L for linolium, plain coloured covering 2 mm thick laid in floors, sealed down with approved adhesive incl stretching, cutting and fitting complete all as specified and directed |
| 45 | Demolition of wall of brick and stone wall built in cement mortor incl all quoins, archs, pillars,etc complete all as specified and directed. |
| 46 | M&L for Half brick work sub class B bricks, straight or curved on plan to any radius built in half brick thick walls CM 1:4 complete all as specified and directed. |
| 47 | M&L for brick work sub class B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 48 | Demolition of cement concrete (reinforced) of roofs (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for mild steel TMT bars 8mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) n less than 0.9mm dia or securing with clips complete all as specified and directed |
| 50 | M&L for providing RCC nominal mix type B0 1:2:4 using 12.5 mm graded agggregate as in chajjas , parapets , fascias etc complete all as specified and directed |
| 51 | M&L for Formwork to chullah hoods , chajjas , troughs , parapets , fascias and similar items including edges to achieve fair finished surfaces of concrete complete all as specified and directed. |
| 52 | M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc complete all as specified and directed. (Reinforcement shall be measured and paid for separately). |
| 53 | Taking down cement or cement lime plaster any description on brick or stone wall/ celling including raking out joint , haking for key scrubing with water etc complete all as specified and directed |
| 54 | M&L for rendering 10 mm thick on fair faces of concrete or brick masonary CM 1:6 finished even and smooth (without using extra cement) complete all as specified and directed |
| 55 | M&L for rendering 10 mm thick on fair faces of concrete or brick masonary CM 1:6 finished even and smooth (without using extra cement) complete all as specified and directed |
| 56 | M&L for rendering 10 mm thick CM 1:6 and setting coat 5 mm thick CM 1:4 with WPC finished even and smooth (without using extra cement) in wall including scaffolding complete all as specified and directed.Note : WPC shall be measured and paid seprately. |
| 57 | M&L for rendering 5 mm thick in ceiling surfaces.CM 1:4 finished even and smooth (without using extra cement) complete all as specified and directed |
| 58 | Taking out existing unserviceable plaster, loose unsound weaken cement concrete of any description and in any position from existing surface of RCC roof slab/ RCC facia/ beams/ columns/ RCC chajja, average depth 20 mm (approximate 6.5 mtrs height from natural GL) with chiesel and removal of debries upto a distence 500 mtrs out side MD land including saw cutting of all edges, making square shoulders of cavaties and roughening of smooth surface, scraping out and removing corrosion and all loose scales, rust etc. from the visible reinforcement and cleaning the steel reinforecement properly providing Zinc primer on visible reinforcement surface to form a contineous film and preparing the surface to recive concrete of epoxy grouting mortar etc. including providing necessary scaffolding complete all as specified and as directed. |
| 59 | M&L for applying bonding coat of modified styrene butadene emulsion in proportion 1 part (bonding agent) : 1 part (water) : 3 part (OP cement) by volume with the brushes etc. to bind new cement plaster/ polymer modified plaster/ concrete/ screed concrete with old surface including removal of loose/ distengrated old concrete/ plaster including preparation of surface etc.complete all as specified and as directed. |
| 60 | S&F of wire netting of galvanised steel wire 1.40mm dia with 20mm size of mess fixed with tinned tacks of wire staples complete all as specified and directed. |
| 61 | M&L for complete removal of existing treatment of wall surface and applying two coat of distemper oil emulsion over a coat of primer and 1 mm thick coat of wall care putty complete all as specified and directed. |
| 62 | M&L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of primer and 1 mm thick coat of wall care putty complete all as specified and directed. |
| 63 | M&L for preparation of new plastered surface of wall and applying three coats of whitewash complete all as specified and directed. |
| 64 | M&L for preparation of new plastered surface of wall and applying two coats of weather proof acrylic paint over a coat of primer complete all as specified and directed. |
| 65 | M&L for complete removal of existing treatment of wall surface and applyiong two coat of weather proof acralic paint over acoat of primer in old surface of wall and filling cracks with white cement etc complete all as specified and directed. |
| 66 | M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 67 | M&L for preparation of old surface of ceiling and applying two coats of white wash complete all as specified and directed. |
| 68 | Demolition of cement concrete(unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above G.L) complete all as specified and directed. |
| 69 | M&L for 75mm thick Cement concrete type C-2, 1:3:6 (20mm graded aggregate) as in plinth protection and Finishing cement concrete surface even and fair with brooming and every 2mtr constrction joint to be provided and filled with bitumen with saw dust complete all as secified and directed. |
| 70 | Taking up or down 15mm dia steel tubing and connection including cleaning for refixing or removal to store complete all as specified and directed. |
| 71 | Taking up or down 20mm dia steel tubing and connection including cleaning for refixing or removal to store complete all as specified and directed. |
| 72 | S&F of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on WALLS / CEILING complete all as specified. supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as specified and directed. |
| 73 | S&F of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on WALLS / CEILING complete all as specified. supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as specified and directed. |
| 74 | Labour for cutting chases,in brick walls pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of andings steps, cills sunshades, shelves lintels etc and cutting chases for concealed water tubing and making good cutting not exc 10 cm grith complete all as specified and directed. |
| 75 | S&F in repair CP bib taps15 mm dia ,chromium plated cast copper alloy with half turn type capstan heads, screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 76 | S&F in repair CP stop/angular cock 15mm dia cast copper alloy, chromium plated fency type screwed down high pressure with half turn type capstan heads, screwed both end for iron pipe or for unions and fixed complete all as specified and directed. |
| 77 | S&F in repair 20mm bore stop valve/gate valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. |
| 78 | S&F in repair 75 mm dia outlet CI nahani trap plain with S/S grating including jointing with solvent cement complete all as specified and directed. |
| 79 | S&F in repairs vitreous china wash hand basin oval type over /under counter wash basin 560x470x 190mm of Ivory colour complete all as specified and directed. |
| 80 | S&F in repairs 15 mm dia pillar tapes Fancy swan neck type of Chromium Plated brass with capstan heads screwed down high pressure, with or without lettered hot and cold with long shank, screwed shanks and fly nuts, screwed for iron pipes or for WHB complete all as specified and directed. |
| 81 | S&F in repairs Viterous China urinals, half stall type (back to corner wall type), complete including providing and fixing plus, beding urinal agianst wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing aroiund urinal back in cement complete all as specified and directed. |
| 82 | S&F in repair PVC waste pipe of 32 mm dia for wash basin/sink complete all as specified and directed |
| 83 | S&F waste coupling of 32 mm dia brass CP for sink/ basins/Urinals, etc with long screwed shanks and fly nuts fanges end bedded in red lead cement and other end fixed. complete all as specified and directed |
| 84 | S&F 6.00 mm thick 600 x 450 mm beveled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 85 | S&F in repairs vitreous china wash down water closet pan pedestal pattern ,white excluding fixing cistern and flush pipe trap front or back inlet including seat cover of any pattern and health faucet (ABS) with rubit cleaning system 1.25 m long, PVC flexible tube and ABS wall hook complete all as specified and directed. |
| 86 | S&F in repair PVC valveless, syphonic action type flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including bracket, complete all as specified and directed. |
| 87 | S&F in repair brass chromium plated tubular towel rail 20 mm dia 'D' type 60 cm long including brackets/flanges completed all as specified and directed. |
| 88 | S&F PVC water connection 450 mm long to wash basin of 15mm dia including CP nuts and washers complete all as specified and directed by Engineer-in-Charge.. |
| 89 | S & F mild steel chromium plated grating doom 100mm dia with or without hole complete all as specified and directed. |
| 90 | S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed. |
| 91 | S&F in repairs for solid PVC kitchen cabinets/cupboards frame/shutters made with 16-18 mm thick Wooden plastic composit (WPC) boards (make - Sintex , rajshri etc) one side laminated and other side white complete all as specified and as directed by Engineer-in-Charge. |
| 92 | Removing of existing unserviceable water proofing treatment including PCC tiles (except PCC padding) taking down cement plaster etc, of any description and cleaning of top surface of cement concrete flushing out junction of parapet walls & washing down with water to remove all dirt etc including preparation of surfaces to receive new treatment and removing the rubbish off premises out side MD land complete all as specified and directed. |
| 93 | Dismantling of un-reinforcement lime concrete/cement concrete in padding to roof slab and removing the rubbish off premisesout side MD land complete all as specified and directed. |
| 94 | M&L for providing cement concrete type B-0, 1:2:4 using 12.50mm graded aggregate laid to slope in padding for WPT over roof slab complete all as specified and directed by Engineer-in-Charge. |
| 95 | M&L for rendering 10mm thick in CM 1:4, mixed with WPC @3% by weight of cement on fair faces of concrete surfaces without using extra cement as in roof complete all as specified and directed.Note:- WPC shall be measured & paid separately. |
| 96 | M&L for preparing clean and dried plastered surface and applying a coat of oil based bitumen primer conforming to IS 3384-1986 @ 0.30 litrs/sqm and then laying APP polymer modified membrane 3 mm thick with non woven polyster reinforced membrane (min 3.00 kg/sqm) having thermal insulation with white mineral gravel finish on upper side of membrane and laid by torch application method to the entire surface complete all as specified and directed by Engineer in Charge. |
| 97 | Supply only intergral water proofing compound. |
| 98 | Dismantling water tanks and exc. 500 but n. exc. 1000 litre capacity complete all as specified and as directed. |
| 99 | M&L for removing the tank over roof and re-fixing in the same position including cleaning complete all as specified and directed. |
| 100 | S&F rotational moulded water storage tank 750 ltr capacity white colour double layer (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 101 | S&F 20mm dia (min weight 210 gms) PVC ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 102 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, frame work for cooler stands , water tank cagings , angle iron frame works , steel ladders , vertical posts , balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 103 | S&F Welded steel wire fabric supplied and fixed complete to steel members of weight not exceeding 4 kg per sqm complete all as specified and directed. |
| 104 | M&L painting to new steel surface of any description over 10cm width or grith not otherwise described including preparation, priming with zinc chromate and two coats of synthetic enamel paint complete all as specified and directed. |
| 105 | M&L painting to old steel surface of any description over 10cm width or grith not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 106 | Taking down PVC pipe (SWR) 110mm dia bore and connection complete all as specified and directed. |
| 107 | S&F 110 mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall. or laid in floors etc complete all as specified and directed |
| 108 | S&F 110mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 109 | S & F Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof for 110 mm bore pipes complete all as specified and directed. |
| 110 | Taking down old/existing MCB DB SPN /TPN with MCB's complete by disconnecting complete all as specified and directed. |
| 111 | Taking down old sub main wiring with 2runs/4runs of 4/6/10 sqmm aluminium/copper cables including making good disturbed surface complete all as specified and directed. |
| 112 | M & L including taking down for concealed point wiring complete with FRLS PVC insulated /unsheathed stranded copper conductor of wire 1.5 Sqmm , 1100 volt grade , alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly, drawn through in PVC conduit pipe fixed in concealed surface of wall/ceilling/false ceilling including cutting /chasing in wall as required with powder coated sheet metal terminal boxes of required sizes and thickness (factory made) sunk in wall only with 3.0 mm thick laminated sheet where as required and accessories complete suitable for the following :- (a) One light/fan point controlled by one, one way switch |
| 113 | All as per item No 112 here in before but one light/fan point controlled by one, 2 way switch. |
| 114 | All as per item No 112 here in before but one socket outlet 05 Amps on the same board |
| 115 | All as per item No 112 here in before but one socket outlet 05 Amps on independent board |
| 116 | All as per item No 112 here in before but One bell/buzzer point controlled by on bell push |
| 117 | All as per item No 112 here in before but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket complete all as specified and directed. |
| 118 | M&L including taking down for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing and capping and its accessories, cadmium screws and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing complete all as specified and directed for the following :- (a) One light/fan point controlled by one on way switch |
| 119 | All as per item No 118 here in before but one socket outlet 05 Amps on the same board |
| 120 | All as per item No 118 here in before but One socket outlet 05 Amps on independent board |
| 121 | All as per item No 118 here in before but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket complete all as specified and directed. |
| 122 | S&F in replacement switch modular 10 amps one way flush type 1 module complete all as specified and directed. |
| 123 | S&F in replacement switch modular 10 amps Two way flush type 1 module complete all as specified and directed. |
| 124 | S&F in replacement switch modular 6 amps bell push flush type 1 module complete all as specified and directed. |
| 125 | S&F in replacement switch modular 16 amps one way flush type 1 module complete all as specified and directed. |
| 126 | S&F in replacement socket modular 2/3 pin 10 amps flush type 2 module complete all as specified and directed. |
| 127 | S&F in replacement socket modular 2/3 pin 25 amps flush type 2 module complete all as specified and directed. |
| 128 | S&F in replacement electronic modular fan regulator 120w step type 2 modular complete all as specified and directed. |
| 129 | S&F in replacement modular white cover plate with frame 1 module complete all as specified and directed. |
| 130 | S&F in replacement modular white cover plate with frame 3 module complete all as specified and directed. |
| 131 | S&F in replacement modular white cover plate with frame 4 module complete all as specified and directed. |
| 132 | S&F in replacement modular white cover plate with frame 6 module complete all as specified and directed. |
| 133 | S&F in replacement modular white cover plate with frame 8 module complete all as specified and directed. |
| 134 | S&F in replacement Modular Metal flush box 1/2 Module complete all as specified and directed. |
| 135 | S&F in replacement of Modular Metal flush box 3 Module complete all as specified and directed. |
| 136 | S&F in replacement of Modular Metal flush box 4 Module complete all as specified and directed. |
| 137 | S&F in replacement of Modular Metal flush box 6/8 Module complete all as specified and directed. |
| 138 | S&F in replacement for sub main wiring with 2 runs of 2.5 sqmm PVC insulated stranded copper conductor FRLS cable and 1 run of 2.5 sqmm copper FRLS cable as earth lead in suitable PVC conduit 20/25mm Dia concealed complete all as specified and directed. |
| 139 | S&F in replacement for sub main wiring with 2 runs of 4 sqmm PVC insulated stranded copper conductor FRLS cable and 1 run of 4 sqmm copper FRLS cable as earth lead in suitable PVC conduit complete all as specified and directed. |
| 140 | S&F in replacement ceiling rose 3 terminals PVC / Polycarbonate, isolated body complete all as specified and as directed. |
| 141 | S&F in replacement Bell, AC, 230 Volts, single pole, Multi music type complete all as specified and as directed. |
| 142 | S&F in replacement Double Door Vertical TPN Distribution Box 4 way complete in SS enclosure with 200 amps rated busbar complete all as specified and directed. |
| 143 | S&F in replacement MCCB 415 Volts, 16 KA breaking capacity, 63 Amp, 4 pole complete all as specified and directed by Engineer in Charge. |
| 144 | S&F in replacement MCB DB SPN 12 way complete in SS enclosure double door type with 200 amps rated busbar complete all as specified and directed. |
| 145 | S&F in replacement MCB DB SPN 8 way complete in SS enclosure double door type with 200 amps rated busbar complete all as specified and directed. |
| 146 | Supply and fixing 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN current carrying capacity 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 147 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 148 | S&F in replacement LED light fitting 4feet, 1x20w, a trendy wall mounted battern,with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 149 | S&F in replacement LED light fitting 2 feet,1x10w,230v,a trendy wall mounted battern,with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 150 | Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type complete all as specified and directed. |
| 151 | S&F in replacement Angle type lamp holder ,PVC /Polycarbonate type With LED bulb 9 Watt complete all as specified and directed by Engineer in Charge. |
| 152 | S&F in replacement of single pole and neutral encloser with a two pin and earth plug and socket complete with one single pole MCB 240V, 20Amps complete all as specified and as directed by Engr-in-Charge. |
| 153 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 154 | S&F exhaust fan, made of sturdy Engineering plastic body complete with louvers shutter, voltage AC single Phase. 230V, 50 Hz of size 300m sweep with,RPM 1200, copper winding, complete all as specified and as directed by Engr-in-Charge |
| 155 | S&F exhaust fan, steel body AC single Phase 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy