| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: REPAIR ROOFING, CEILING, ROOF TREATMENT AND OTHER ALLIED WORKS IN VARIOUS UNIT AT GULPUR, SEKHLU AND NATU UNDER AGE B/R-II OF GE 881 EWS. Contract No : GE/PNH-123/2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down existing tarfelt including tiles and demolition of concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same to a distance exc. 1.50 Km and n exc. 5.0 Km including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc and , complete all as specified and as directed. |
| 3 | Water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification including ponding test as specified :- |
| 4 | Applying a coat of cement slurry @ 3Kg cement/sqm on cleaned surface of RCC roof slab complete all as specified and directed. |
| 5 | PCC type B-0, 1:2:4 (using12.50mm graded crushed stone aggregate ) as in padding to roof slab and finishing surface smooth and even to maintain levelling on existing slab complete all as specified and directed. |
| 6 | 10mm thick screed bed or bedding layers in cement mortar 1:4 on roof slab including parapet and including mixing of liquid water proofing compound @ 200ml per 50 Kg of cement bag complete all as specified and as directed. NOTE : Supply only liquid water proofing compound shall be measured and paid separately. |
| 7 | Applying bitumenous primer conforming to IS-3384 @ 0.3 ltrs per Sqm over plastered surfaces of roof including parapet surface. |
| 8 | Applying a coat of hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-3384 @ 1.20Kg per Sqm over primer surfaces of roof slab including parapet surface. |
| 9 | Providing a layer of polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen with torch application method including end overlaps not less than 150mm and side lap 75mm, membrane shall be five layered with centre core as 90 microns high density polyethylene film, minimum weight of membrane shall be 3.60Kg/ Sqm, overlaps shall be sealed with suitable adhesive as per manufacturer,s instructions, polymeric membrane shall be taken to a height of 60cm (min) and inserted inside the groove of parapet wall and shall be finished by a membrane flashing complete all as specified and directed.Note:- Bitumen coat shall be measured and paid for separately |
| 10 | Applying a coat of hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-3384 @ 1.20Kg per Sqm over APP membrane and blinded with dry fine sand @0.50Kg/sqm dusted over bitumen coat complete all as specified and directed. |
| 11 | Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed. |
| 12 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically described complete all as specified and directed by Engineer-in-Charge. |
| 13 | Plain cement Concrete 1:2:4 type-B1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed. |
| 14 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed. |
| 15 | Dismantling of timber scantling 40sqcm and over in section framed work,as in any position, complete all as specified and directed. |
| 16 | Dismantling of timber scantling under 40sqcm in section framed work as in fillets, rails, posts, rafters, purlins etc , complete all as specified and directed. |
| 17 | Second class hard wood in scantlings, clean sawn timber framed and fixed, all as specified and directed. |
| 18 | Dismantling or wall/ceiling board (fibre, pulp, insulation, etc) or insulation board slabs/blankets, of any thickness, including cover fillets complete all as specified and directed. |
| 19 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 20 | Demolition of brick or stone masonry, build in cement mortar including all quoins, arches, pillar etc complete all as specified and directed. |
| 21 | Walling of random rubble stone masonry, uncoursed , well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed. |
| 22 | Description all as per item No. 20 above, but except stone. |
| 23 | Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed. |
| 24 | Rendering 15mm thick in cement mortar (1:4) on fair faces of brick work mixed with liquid water proofing compound as per manufacturer instructions, finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note: Supply only WPC shall be measured and paid for separately. |
| 25 | Preparation of newly plastered or unplastered surface of wall and applying two coat of cement base paint in camouflage pattern, complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge. |
| 26 | Preparation of newly plastered or unplastered surface of wall and applying two coats of Oil Bound Distemper (any tint),complete all as specified and directed |
| 27 | Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as specified and directed. |
| 28 | Exposed metal frame ceiling 600x600mm with 6.00mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in and including 605 mm x 605mm GI grid and including 4mm dia GI wire hanger of required length fixed in RCC Roof/Truss etc with 40x3mm size 60mm long GI flat and expansion hold fastern of minimum 12.50mm dia complete all as specified and directed. |
| 29 | 5-6mm thick hollow insulated PVC coloured wall panelling including lining and necessary cleats, screws, bedding etc complete fixed to wall complete all as specified and directed. |
| 30 | 5-6mm thick hollow PVC sheeting as in false ceiling with GI grid system Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm and including thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 31 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed by Engineer- in Charge. |
| 32 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed by Engineer- in Charge. |
| 33 | 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap,fixed with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed. |
| 34 | 0.63mm Plain, black, mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings fixed with L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 35 | Preparation of new or untreated steel surface of any description exc.10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 36 | Preparation of old or undecorated steel surface of any description exc.10 cm in width or girth and applying one coat of synthetic enamel pain complete all as specified and directed. |
| 37 | Preparation of new/old wood surfaces of any description and girth, not other wise, described and treated with creosote oil, complete all as specified and directed. |
| 38 | Mild steel work as in wind ties for roof including securing bolts, flat iron fillets including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-410 or Fe-310 all as specified and directed. |
| 39 | Taking up or down steel tubing of 20 mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 40 | Refixing old steel water tubing of 20 mm bore and connections in new or old position fixed to walls, ceilings and floors etc. including fittings as requiered, complete all as specified and directed. |
| 41 | Steel water tubing 20mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified and directed. |
| 42 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of exc 250 & n exc 500 ltr capacity.including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc, complete all as specified and directed. |
| 43 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of exc 500 & n exc 1000 ltr capacity.including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc, complete all as specified and directed. |
| 44 | Dismantling water tanks of any description, exc 500 & n exc 1000 litre capacity and removing from site. |
| 45 | Dismantling water tanks and removing to store of capacity exc 250 & n.exc 500 ltrs. |
| 46 | 500 ltr capacity rotational moulded polyethylene water storage tanks, double layer(Cylindrical vertical with threaded close top), ISI marked and fixed in position, all as specified in SSR Part-I, , complete all as specified and directed. |
| 47 | 1000 ltr capacity rotational moulded polyethylene water storage tanks, double layer(Cylindrical vertical with threaded close top), ISI marked and fixed in position, all as specified in SSR Part-I, complete all as specified and directed. |
| 48 | Ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule, 20mm bore fixed in repair, complete all as specified and directed. |
| 49 | Ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule,15 mm bore fixed in repair, complete all as specified and directed. |
| 50 | Supply only liquid water proofing compound. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |