| 1 | Taking down existing water proofing treatment of any description incl PCC padding,/ or cement plastering work any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment incl make good necessary dubbing out wherever required and removing rubbish from site complete all as specified and directed. |
| 2 | Material and Labour for Brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and as directed. |
| 3 | Matrial and Labour for Cement Concrete 1:2:4 Type B-0 (12.50 mm Graded Stone aggregate in padding, finishing surface concrete topping even and fair (without using extra cement) of average thickness 40 mm in slope as required over roof complete all as specified and as directed. |
| 4 | Material and Labour for 10 mm thick Plastering in CM 1:4 on concrete roof surfaces using water proofing compound @ 3% by weight of cement and finishing the surface even and fair complete all as specified and directed.WPC will be measured separately. |
| 5 | Supply only liquid waterproofing compound ISI Marked all as specified and as directed. |
| 6 | Material and Labour for Applying evenly two coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m incl cleaning surface complete all as specified and as directed. |
| 7 | Material and Labour for APP based polymeric membrane( plain /gravel) minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application ,The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer complete all as specified and directed. |
| 8 | Material and labour for one coat of aluminium paint at the rate of 100 gm/Sqm as per manufacturer's instructions over bituminous layer, complete all as specified & directed at site. |
| 9 | Supply and Fix in repair Galvanized Steel Tubes of bore 15/20 mm, Medium grade' galvanised, with all necessary fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge |
| 10 | Supply and Fix in repair Galvanized Steel Tubes of bore 20 mm, Medium grade' galvanised, with all necessary fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge |
| 11 | Supply and Fix in Repairs PVC (SWR) pipes of 110 mm Dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls incl all necessary fittings complete all as specified and as directed by Engnr-in-Charge |
| 12 | Supply and Fix in Repairs PVC (SWR) pipes of 75 mm Dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls incl all necessary fittings complete all as specified and as directed by Engnr-in-Charge |
| 13 | Supply and Fix for Bands Straps Supports or stays for Rainwater Ventilating Pipes Including Bolts if required Hooks stay heavy for large complete all as specified and as directed. |
| 14 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed. |
| 15 | Material and Labour for 15 mm thick rendering in cement plaster 1:4 on fair face of brick/concrete/stone masonry surfaces including finishing the surfaces even and smooth (without using extra cement) incl mixing with integral water proofing compound complete incl Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water and appllying two coats of cement base paint over a coat of primer and putty where required on wall including preparation of surfaces complete all as specified and directed.etc complete all as specified and directed. Note:- Integral water proofing compound will be measured and paid separately. |
| 16 | Material and labour for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement & preparing new plastered surface of wall and applying three coats of white wash complete all as specified and directed. |
| 17 | Supply and Fix in repairs vitreous china squatting pan, ‘Orissa’ pattern', size 580 mm x 440 mm, white with integral foot rests, embedded and set in PCC 1:5:10 type E-2 incl flush pipe, traps etc complete fittings and making good to floor including removing rubbish all as specified and directed. |
| 18 | Supply and Fix in repair 10 ltrs capacity PVC low level flushing cistern, of make specified with inlet, float valve and handle including bracket with 32 mm dia PVC flush pipe complete all as specified and as directed. |
| 19 | Demolition of brick work, built in Cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 20 | Material and Labour for brick work with fly ash bricks (modular size bricks), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 21 | Material and Labour for sunken floor treatment as in following precedence (i) The treatment of existing sunken floor is to be dismantled upto full depth of Sunken RCC Slab and the surfaces both vertical and horizontal shall be cleaned by removing all loose mortar, dirt, dust etc. by chisel, hammer, wire brush/Jute Brush and Air Blower machine than apply two coats of elastomeric compound viz back bond WPC-30 over one coat on neat primer i.e. Super latex be applied on clean surface.(ii) Provide 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base and provide 40mm dia GI pipe med gde as in (spout) of 600mm long as in sunken portion. (iii) Then rendering 15mm thick in CM 1:3 using liquid water proofing compound @ rate 200 ml per 50 Kg bag of cement on horizontal and vertical surfaces of sunken portion. Note: Water proofing compound shall be measured and paid separately. (iv) The sunken floor tested for leakage/seepage by ponding it with water for minimum 72 hrs.(v) Then fill the remaining sunken portion with PCC 1:5:10 using brick aggregates including fixing sanitary items requiring embedding in cement concrete. To ensure that there shall not be any seepage/dampness in the slab as seen underneath and side. |
| 22 | Material and Labour PVC (SWR) floor trap plain with grating incl jointing with solvent cement 75 mm bore complete all as specified and direcetd. |
| 23 | Supply and Fix in repairs 15 mm bore stop cock,(angle valve) cast copper alloy, fancy type, chromium plated, screwed down, high pre-ssure screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 24 | Supply and Fix in repairs 15 mm bore Bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferulle and fixed complete all as specified and directed. |
| 25 | NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 5835.00/- ] Please Enable Macros to View BoQ information |