Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" |
| 2 | SCHEDULE \\"A\\" PART-I (Building / Structures) (To be quoted by the contractor)Bbuilding works mentioned at item NO 1(A), Item No 1(B) & item NO 1(C) is in ENGINEERING PROCUREMENT CONSTRUCTION (EPC) Mode. Contractors has to carry out the detailed engineering design of these building, procure all the equipments and materials necessary and then construct to deliver a fully functional facility to the MES department. |
| 3 | Item No 1 (A) : Designing (Structurally & Aesthetically) and construction of block of Single Men Barracks For Agniveers permanent specification for (G+3) Storey RCC Framed Structure all as per design basis report, detailed in scope of work and other documents of the tender complete all specified and directed. |
| 4 | Item No 1 (B) : Designing (Structurally & Aesthetically) and construction of block of Dining Hall & Anti Room For Agniveers with permanent specification for Storey RCC Framed Structure all as per design basis report, detailed in scope of work and other documents of the tender complete all specified and directed. |
| 5 | Item No 1 (C) : Designing (Structurally & Aesthetically) and construction of block of Cook House For Agniveers permanent specification for Storey RCC Framed Structure complete all as per design basis report, detailed in scope of work and other documents of the tender complete all specified and directed. |
| 6 | Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 7 | Sch 'A' Part-II(A) (Internal Water Supply) Lump sum price worked out by the contractor for (Internal Water Supply) as listed in Schedule 'A' Part-II(A) against the lump sum price inserted by the MES. |
| 8 | Sch 'A' Part-II(B) (Internal Electric Supply) Lump sum price worked out by the contractor for (Internal Electric Supply) as listed in Schedule 'A' Part-II(B) against the lump sum price inserted by the MES. |
| 9 | Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for 'External Water supply' as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-IV (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for 'Area Drainage' as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-VII (Summer & cooling Applinces) Lump sum price worked out by the contractor for (Summer & cooling Applinces) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 14 | Sch 'A' Part-VIII (Arboriculture) Lump sum price worked out by the contractor for (Arboriculture) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 15 | Sch 'A' Part-IX (FIRE FIGHTING SYSTEM) Lump sum price worked out by the contractor for (FIRE FIGHTING SYSTEM) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 16 | Sch 'A' Part-X (Lightning Protection System) Lump sum price worked out by the contractor for (Lightning Protection System) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 17 | Sch 'A' Part-XI (Demolition) Lump sum price worked out by the contractor for (Demolition) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 18 | Sch 'A' Part-XII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 19 | Note for Srl No 2 to 18The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 18 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 20 | Schedule 'A' Part-XIII (Miscellaneous items of works) |
| 21 | External Electric Supply |
| 22 | Item No 02 : Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 160 KVA (Level-3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 160 KVA & cable box on LT side. |
| 23 | The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, |
| 24 | exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transformer shall also includes connected accessories all as specifed and directed. |
| 25 | Item No 03 : Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. |
| 26 | Item No 04 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 27 | Item No 05 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 28 | Item No 06 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 29 | BUSBAR :- (i) 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 30 | INCOMING :- |
| 31 | (a) MCCB 4 Pole 350 Amps, 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) |
| 32 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 33 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 34 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 35 | (f) Copper wound with CTR 600/5 - 03 Nos |
| 36 | OUT GOING |
| 37 | (i) MCCB 4 Pole 250 Amps, 36 KA at 415 volts - 02 No.(SM Bldg) |
| 38 | (ii) MCCB 3 P 100 Amps 25 KA, 415 volts - 01 Nos (Centralised Cooler) |
| 39 | (ii) MCB 4 P 40 Amps, 415 volts - 02 Nos (Post top lantern Light & LED bollard light) |
| 40 | (iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 41 | (iv) Auto control time switch, timer control for different 24 hours adjustable type including power contractor of capacity 20 amps complete - 01 Nos (1 x Garden Light) |
| 42 | Item No 07 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts including junction box with 6-32 A MCB of size complete as all specified and as directed. |
| 43 | Item No 08 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 44 | Item No 09 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 45 | Item No 10 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 46 | Item No 11 : S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 47 | Item No 12 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed. |
| 48 | Item No 13 : Material and labour for LT 1100 volts (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-120 sqmm complete all as specified and as directed. |
| 49 | Item No 14 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying one coats of black bituminous paint complete all as specified and as directed. |
| 50 | Raod Path Culvert |
| 51 | Item No 15 : M & L for laying bituminous premix asphaltic semi dense concrete avaraging 40mm consolidated thickness with 5.5% binder content by weight of total mix using asphalt mechanical mixer plant & consolidated with 8to 10 ton power road roller to reqd level gradient camber and super elevation. |
| 52 | Item No 16 : S&F Traffic convex minor of size 800 mm dia unbreakable having clear and definite mirror image with upper class collar provided with suitable clamps & nut bolts. The complete set shall be fixed on MS pipe 65mm NB 2.0 meter long from Ground level duly powder coted/painted white/blue color etc complete all as specified and directed. |
| 53 | External Electric Supply (Supply DG Set) |
| 54 | Item No 17 : Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set not less than 20 KVA or nearest standard size, 415 volts, 3 phase 4 wire, 1500 rpm, 50 Hz power supply with power factor 0.8 couple directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. |
| 55 | The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV + Emmission compliant) latest norms/regulation Noise level 75dB(A) at a distance of one meter with fuel tank, battery and standard accessories as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications of :- |
| 56 | ENGINE - 3 cylinders, inline, 4 stroke cycle, Water cooled, developing Matching 25.5 BHP at 1500 RPM under NTP conditions of BS:5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output 20 KVA/ 16 KW at 0.8 power factor, 415 Volts at the alternator terminalALTERNATOR: single bearing alternator suitable for continuous operation generating 20 KVA at 1500 RPM, 415Volts , 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000/ IS 4722. The alternator is brushless type, screen protected, revolving field, self excited alternator confirming ti IS/IEC 60034-1, self regulated through an AVR. The alternator has the following features: a) ± 0.50% voltage regulation (max.) in static conditions |
| 57 | (b) IP: 23 protection with insulation class H. (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) 3 phase reconnectable winding with 12 terminal brought out for connection. (e) dedicated winding speecially designed for 1 phase operation (f) double layer lap startor winding (g) PCC foundation complete as per manufacturer's design including anti vibration pads, necessary excavation & earth work in soft/loose, sand cushioning, grouting foundation etc. |
| 58 | Features, Functions, Protections(a) 16 character x 2 line alphanumeric LCD display with LED backlight (b) Operator interface (c) Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory (d) Provide Alternator data fequency Control includes provision for Service adjustment and calibration of DG control functions(a)Voltage, frequency selection(b)Meter calibration(c)Configurable input and output set up PowerStart operates on 12 V DC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. |
| 59 | Engine Starting – The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency.Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal.Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working.Engine Protective Functions includes - Configurable alarm outputEmergency stop: Annunciated whenever an emergency stop signal is received by the control(a).Low Lube oil pressure warning and shutdown(b)High engine water temperature warning/ shutdown |
| 60 | (c) Low coolant temp warning (d) Sensor failure indication(e)Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine(j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods.Alternator Protective functions includes : (l) High and Low AC voltage shut down (m) Under and over frequency shutdown / warning (n) Loss of sensing voltage input shut down (o) Battery charger alternatorFuel tank: Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity to operate 8 to 12 hrs on 100% load. (b) Base Rail: Base Rail with integral fuel tank is provided.Batteries: For electrical control circuit ,12 Volts/88 AH battery for electrical starting of DG set |
| 61 | AMF ELECTRICAL CONTROL PANEL : Inbuilt AMF Panel is manufactured with 14/16 guage fabricated out of 2mm thick CRCA sheet, floor mounting type, powder coated for weather-proof and long lasting finish, totally enclosed, front higed cover, instrument swithches and panel complete alla as specified and required. |
| 62 | One set of accessories (As per manufacture's instruction) :- |
| 63 | (aa) Fuel tank with locking arrangement for 08 hours running on full load |
| 64 | (ab) Level indicator on fuel tank |
| 65 | (ac) Drain plug |
| 66 | (ad) MS class \\"C\\" piping , suitable dia and length for fuel inlet from tank to engine as per manufactures instruction. |
| 67 | (ae) Fuel strainer and fuel tank with air vent. |
| 68 | (af) Batteries heavy duty 12 Volts 88 AH lead acid type fully charged, indication of high flow charing changed : - 01 Nos |
| 69 | (ag) Cable connection from alternator to DG set control panel as directed |
| 70 | Tools (As per manufactures instructions):- |
| 71 | (aa) 'D' spanners - 01 Set |
| 72 | (ab) Ring spanners - 01 Set |
| 73 | (ac) Screw diver 5\\" to 12 \\" - 01 Set |
| 74 | (ad) Cutting plier 9 \\" - 01 No |
| 75 | (ae) Hammer 2 LBS - 01 No |
| 76 | Base frame arrangements . The engine and alternator would be coupled by means of specially diesigned flexible coupling and both the units including the radiator would be mounted on a rigid fabricated base to form a compact arrangement. The steel shall be Tisco / SAIL or equivalent make. |
| 77 | Sound acoustic enclosure : CPCB approved sound acoustic enclosure sutable for above genrator set with complete set installed within canopy. |
| 78 | Item No 18 : M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor/hard standing. |
| 79 | Item No 19 : Earthing complete for various equipments with galvanised steel earth plate electrode 600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as directed. |
| 80 | Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate. |
| 81 | Item No 20 : S & F earth continuity conductor for main earthing lead 32 X 6 mm strip burried in ground or fix in walls with bolts all as specified and directed by engineer in charge. |
| 82 | Summer & cooling Applinces |
| 83 | Item No 21 : Supply and fixing of ducted cooler top/down discharge - 03 Nos/Floor nominal air delivery of 25000 CMH ,1.5 KW Motor power,cooling capacity upto 1600 sq ft UV Stablized High Grade Plastic of Tank capacity 70 litres Fan Dia 620 mm with Honeycomb pads of thickness 100 mm with 80 % minimum cooling efficiency,with 3 phase starter ,hanger hook and L shaped bracket including supply ,Installation ,commissioning and balancing of site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. Duct with 1:3 Ratio of 22G 0.7 mm and 24G 0.6 mm sheet from machine to ceiling height and ceiling to the alumium grills should rectangular shape ducting complete with neoprene rubber gaskets,nitrile rubber acoustic insulation of size 19 mm (inside), thermal insulation of size 6 mm (outside ), elbows,splitter damper |
| 84 | vanes,hangars,supports.Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Powder coated alumium Grill and Volume control damper should be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve .The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. |
| 85 | All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets.Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The fabrication of ducts shall be carried out as per approved drawings and specifications of following sheet thickness complete all as specifed and as directed.Note: (i) The duct work shall be as per IS 655.(ii) The GSS sheets for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per ISS-277 all as specified and directed |
| 86 | Item No 22 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 87 | BUSBAR :- (i) 150 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 88 | INCOMING :- |
| 89 | (a) MCCB 4 Pole 100 Amps, 25 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) |
| 90 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 91 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 92 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 93 | (e) Copper wound with CTR 200/5 - 03 Nos |
| 94 | OUT GOING |
| 95 | (i) MCB 4 P 'C' Series 32 Amps, 415 volts - 03 Nos |
| 96 | (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 97 | Item No 23 : Supply, installation, commissioning Auto Clean Kitchen Chimney, Baffle Filters, Touch Control with Motion Sensor 60/90cm 1200 m3/h - Silver (6078 MS AC) and all as specified and directed. |
| 98 | Item No 24 : Supply, installation, commissioning refrigerator, electric driven (single phase), capacity more than 195 Litres upto to 310 Litres.BEE 5 star rated all as specified and directed. |
| 99 | Arboliculture |
| 100 | Item No 25 : Plantation of tree of fruits/Herbal nature and taking care for three year after complition of work including watering providing manure/fertilizer etc complete all as directed. |
| 101 | Rain Water Harvesting |
| 102 | Item No 26 : M & L for composite rain water harvesting system of 5000 litre capacity include of the following (i) under ground water storage tank of 5000 litre capacity 01 No(ii) First flush system 01 No(iii) Gravity Filter 01 No(iv) Delivery pipe 25 mm size UPVC (SCH- 40) 15 RM(v) Down take pipe 100 mm size UPVC (SCH- 40) 15 Rm |
| 103 | SEWAGE |
| 104 | Item No 27 : Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) conforning to IS-16098:2013 part -I with and incl jointing materials complete |
| 105 | Item No 28 : M&L RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. |
| 106 | Item No 29 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M x 3.0 M depth complete |
| 107 | External Water supply |
| 108 | Item No 30 : Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,100 mm (4”) dia and all as directed. |
| 109 | Item No 31 : M&L for tapping in existing DI pipe lines 150 mm dia and inserting tee of 150x 100 mm and all as directed. |
| 110 | Item No 32 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm |
| 111 | angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 112 | Item No 33 : Supply, installation, testing and commissioning LT , 415 Volt, 4 wire AC 50 Hz, cubical panel (Feeder Pillar Box) factory made, out door, pedestral type, feeder pillar box, hutted roof, weather & vermin proof fabricated of 3.0mm thick MS black sheet, front & back double shutter opening type, spray two earth terminal suitable cable glands for all incoming and outgoing cable including grounting of feeder pillar box 60cm above ground level by providing 90 cm long angle iron of size 50 x 50 x 6mm welded on all the fours corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm, complete all as specified and directed by Engr-in-Charge including the following accessories /components. |
| 113 | (a) Aluminium bus bar - 200 amps rating - 03 Nos. ( for phases and 100 Amps for neutral 01 No insulated with proper colour coding phase wise ). Qty -04 (b) Incoming MCCB 4 pole 100 Amp, 415 volt, 16 KA Thermal setting 70% to 100% - 01 No (Incoming) (Qty 02 no.) (c) Outgoing (i) MCB TPN 20 to 63 Amps - 02 Nos (d) Automatic star-Delta starter for borewell as suitable after pump lowering(ii) MCB SPN 6 to 10 Amps - 02 No (e) MPCB for borewell as require and suitable for borewell (f) Require neceesarry wiring/cable (size of cable depnd upon the pump installed in the borewell) for connection of panel to a near by Electric line |
| 114 | Item No 34 : M&L for fabrication, transportation, erection & testing for Hot compressed molded SMC (sheet molding compound) panel tanks of 12000 gallon capacity , erected at ground level using steel structure of of Brand SINTEX, AMITEX, DEVI POLYMERS as per BIS: 14399 Part-I & Part-II. ISI Marked SMC Panel tanks of approved brands. Roof & Base of SMC Panel tanks having panels of size 1.00 m x 1.00 m, 1.00 m x 0.5 m . Side Walls of tanks shall be constructed using SMC panels of size 1.00 m x 1.00 m panel as per site requirement or as per OEM standards. One manhole of diameter 600mm lockable lid of hot pressed moulded made out of SMC should be provided on the roof of tank with lockable lid and aluminium ladder above 1mtr height inside & outside the tank for access. Tanks must have vertical iron posts lied firmly with Tie rods. |
| 115 | The panel should withstand Hydrostatic pressure of atleast 4 times the working load and should be provided with HDG bolts, nuts, washers, food grade foam gasket, cleats, including PVC pipe support of 110mm dia for the roof of top panels. Tank shall be erected on steel base at site as per manufacurer's specifications & design. Provision of holes for inlet and outlet, overflow should be made as per direction of Engineer-in- Charge and including connecting with 9\\" long thread end Nipple complete all as specified & directed by Engr in Charge. The Tank installation work will be carried out at roof of building/ ground level. Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 116 | The panel should withstand Hydrostatic pressure of atleast 4 times the working load and should be provided with HDG bolts, nuts, washers, food grade foam gasket, cleats, including PVC pipe support of 110mm dia for the roof of top panels. Tank shall be erected on steel base at site as per manufacurer's specifications & design. Provision of holes for inlet and outlet, overflow should be made as per direction of Engineer-in- Charge and including connecting with 9\\" long thread end Nipple complete all as specified & directed by Engr in Charge. The Tank installation work will be carried out at roof of building/ ground level. Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 117 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 120 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed.Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately. |
| 118 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed etc of the under mentioned type and sizes :- |
| 119 | (a) 3.5 core x 120 sqmm |
| 120 | (b) 2 core x 6 sqmm (Garden lighting & Post top Lantern) |
| 121 | (c) 4 Core X 25 Sqmm (Centralised Cooler) |
| 122 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 123 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 124 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 125 | Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid. |
| 126 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 127 | Supplying and laying unreinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 128 | Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminium paints over a coat of red oxide primer, including painting white & red alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint and writing numbering of poles with black paint on yellow background complete all as specified and as directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items) |
| 129 | M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted. |
| 130 | M&L for GI tube light grade with all fitting laid in trenches of fixed to pole of size:- |
| 131 | (a) 50 mm Dia |
| 132 | (b) 80 mm Dia |
| 133 | M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 134 | M&L for Precast Reinforced Cement Concrete(RCC) 1:4:8 type D2 using 40 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. ( Note :Reinforcement shall be measured and paid for separately.) |
| 135 | M&L for 40 to 80mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. |
| 136 | S&F for lightning arrestor Expulsion type complete with all fittings, transmision/ distribution class , current rating 65 kA suitable for 11 KV system, discharge capacity 65 kilo amps and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed.Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE. |
| 137 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. |
| 138 | Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. |
| 139 | Supply and fixing HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 -185 sqmm complete all as specified and as directed. |
| 140 | Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed. |
| 141 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. |
| 142 | Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 143 | S & F drop out fuse unit explusion type for out door air break gang oprated switch single pole mounted on and including two numbers insulators for 11 KV working pressure fixed to MS channel with nuts, bolts and washer etc and current carry capacity above 50 Amp upto and 100 Amp complete all as specified and as directed. |
| 144 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 145 | Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed. |
| 146 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 147 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed . Total carried over to BOQ Rs. 9814019.87 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part II(A) (Internal Water Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 148 | S&F 15 mm bore galvanized steel tubing, medium grade galvanised with all fittings, complete all as specified and directed. fixed to walls and ceilings or laid in floors incl cutting chasing and making good complete all as specified and as directed. |
| 149 | S&F 20 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 150 | S&F 25 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 151 | S&F 40 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 152 | S&F in 20mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing nines on both ends complete all as specified and directed |
| 153 | in S&F in 25mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to Charge. existing pipes on both ends complete all as specified and directed |
| 154 | S&F in 40 mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed |
| 155 | S&F in 15mm dia pillar taps, cast copper alloy with capstan heads chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron nine complete all as specified |
| 156 | S & F in for long body Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm, fancy type chromium plated fixed complete. |
| 157 | S & Fix for Angle cock/Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed 15 mm fixed complete |
| 158 | S&F in PVC connections 15 mm size with brass nuts both side of length 450 mm complete all as specified and directed |
| 159 | S & F in Brass chromium plated wall Mixer (2/3 hole) for mixing hot & Cold water arrangement, long shank suitable 15mm bore of pipe of approved quality screwed down for iron pine and fixed |
| 160 | S&F in chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed Total carried over to BOQ Rs. 864057.44 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part II(B) (Internal Electric Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 161 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area). two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories, after chasing in wall/ceiling etc, heavy duty Isi marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following:- (a) One light point controlled by one, one way switch 5 Amps Point 992.75 790.0 784272.5 (b) One fan point/ exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator Point 992.75 276.0 273999.0 (c) One light point controlled by, two way switch 5 Amps Point 1397.96 12.0 16775.52 (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. Point 284.1 60.0 17046.0 (e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. Point 1070.4 252.0 269740.8 |
| 162 | Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded Point flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary the common eath dolly. running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 163 | Description all as per item No. 1 here in before but using 4.0 sq mm single core copper conductor two nos FRLSH cable of Point multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary connecting to the common eath dolly. running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 164 | S&F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed. |
| 165 | S&F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 166 | S&F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 167 | S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified |
| 168 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed. |
| 169 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and dircted. |
| 170 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded RM copper conductor of size 1.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC cond of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 1.5 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 1.5 sqmm cable,one run of 1.5 sqmm cable and one run of PVC conduit will be measured as one unit |
| 171 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 172 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSHH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 173 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSh cable with stranded F copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Four runs of 10 sqmm cable(03 phase and 01 Neutral), two runs of 10 sqmm cable for earth and one run of PVC conduit will be measured as one unit |
| 174 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded F copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 10 sqmm cable,one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit |
| 175 | S & F for sheet metal enclosure MCCB DB VTPN 04 way Vertical type with min 100 Amps rated copper bus bar 415 volts for incoming MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnetic locking system including blanking plate and necessary provision for inserting the DBS in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. |
| 176 | S & F for sheet metal enclosure MCCB DB VTPN 04 way Vertical type with min 150 Amps rated bus bar 415 volts for incomming Eas MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnitic locking system including including blanking plate necessary provision for inserting the DBS in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.(Ground floor) |
| 177 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door including blanking Eac plate for dummy space with magnitic locking system including necessary provision for inserting the DBS in wall by cutting the and as directed. brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified |
| 178 | S&F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate Each for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone directed. masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 179 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door including blanking plate Each for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone directed. masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 180 | S & F for MCCB four pole rated capacity 63 Amps,( nearest standard size) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed |
| 181 | S & F for MCCB four pole rated capacity 40 Amps, ( nearest standard size) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed. |
| 182 | S & F for MCB DP rated capacity 32 Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all as I specified and as directed. |
| 183 | S & F for MCB DP rated capacity 25-16 Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all E as specified and as directed. |
| 184 | S & F for MCB DP rated capacity 63 Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all as E specified and as directed. |
| 185 | S & F for MCB Single pole rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as E directed. |
| 186 | S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed . |
| 187 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 V, 1200 Ea mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 188 | S & F for energy efficient exhaust fan of 300 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt, embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 189 | S & F for energy efficient exhaust fan of 450 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt, embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 190 | S&F surface/recess mounted ceiling light of capacity 36 watt, approx size of 2x2 ft, 230 volts with CRCA housing luminous efficacy not less than 120 lumen/W with and intregrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed. |
| 191 | S & F surface mounted mirror light of capacity 10 watt, 2 feet,, 230 volts with CRCA housing with and intregrated electronic driver with luminous efficacy not less than 120 lumen/watt connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed. |
| 192 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/watt 230 volts and intregrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 193 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light E fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts, luminous efficacy not less than 110 lumen/watt LED Chip, Driver and housing should be of same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia Gl pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer-in- charge. Total carried over to BOQ Rs. 4566901.69 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (External Water supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 194 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 50 mm and all as directed. |
| 195 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 40 mm and all as directed. |
| 196 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 25 mm and all as directed. |
| 197 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 20 mm and all as directed. |
| 198 | S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed. (a) 50mm bore Each 979.08 3.0 2937.24 (b) 25mm bore Each 587.24 2.0 1174.48 (c ) 20mm bore Each 540.11 2.0 1080.22 |
| 199 | Supply and fix Valves, Sluice, flanged of class 1.6 PN,100 mm dia and all as directed. |
| 200 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 201 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 202 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. Total carried over to BOQ Rs. 126492.34 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IV (ROAD PATH CULVERT) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 203 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil |
| 204 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil |
| 205 | Add to (or deduct from) last item for every 3 cm or part thereof above or below 15 cm average depth in soft /loose soil |
| 206 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 207 | M & L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete. |
| 208 | M&L for soling (sub base) with broken boulders or quarried stones 200 mm thick spread interstices filled surface formed rolled and consolidated to required gradient and camber all as spfd. |
| 209 | M & L for Laying and compacting 150 mm thick (compacted thickness ) WMM laid in two layers of 75 mm each Wet Mix Macadam (WMM) grading as pe table 400-13 of MaRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge works 2013 complete all as specified. |
| 210 | Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 2 - 0.30 kg/sqm on surface of bitumen including preparation of bitumen surfaces as specified in Table 500-5 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of bitumen surfaces all as specified and directed . |
| 211 | M&L premixed bituminous macadam laid/rolled and compacted to required gradient and camber with using 20 mm graded stone agg and paving bitumen 4% by the weight of total mix (consolidate thickness 75 mm or less as required ) complete all as specified and as directed. |
| 212 | Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface of WMM/WBM including preparation of WBM/WMM surfaces as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of WBM/WMM surfaces all as specified and directed . |
| 213 | Continuous edging with roughly squared sand stones of size 30 cm x 5 cm (30cm deep & 5 cm thickness), length of each patti not less than 60 cm Complete of using sand stone/Katni sone all as specified and directed. |
| 214 | M&L preparation of road surface and applying thermoplastic relflective paint in white or any tint marking of min 2 mm thick single coat as in center line and edge line road marking of 150/100 mm width using ''HOT MARK\\" thermoplastic modern propelled road marking machine as directed incl all ingredients such as blinder, glass beads, Titaniumdioxide calcium carabonate inter fillers thermroplastic requirement for glass beads shell be the Table No 650.4 of MOT specifications incl spraying of glass beads etc all as per manufactures instrustions and as directed |
| 215 | M&L for Cement concrete type D-2 1:4:8 (using 20 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed. |
| 216 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. |
| 217 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified. |
| 218 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 219 | Supply and fixing in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. |
| 220 | Supply and fixing in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed |
| 221 | S&F Traffic convex minor of size 800 mm dia unbreakable having clear and definite mirror image with upper class collar provided with suitable clamps & nut bolts. The complete set shall be fixed on MS pipe 65mm NB 2.0 meter long from Ground level duly powder coted/painted white/blue color etc complete all as specified and directed. |
| 222 | S&F 600 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 223 | M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 600 mm bore complete all as specified and directed. |
| 224 | S&F 450 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 225 | M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 450 mm bore complete all as specified and directed. |
| 226 | Returning filling in including spreading levlling ,watering and well ramming in layers nexc 25cm thick complete all as specified and directed. Total carried over to BOQ Rs. 5609345.24 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part V (Sewage Disposal) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 227 | Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed. |
| 228 | Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed |
| 229 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 230 | Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 231 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 complete |
| 232 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. |
| 233 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed. |
| 234 | M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed. |
| 235 | M&L for 15 mm thick rendering in cement mortar (1:3) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction , finished even and smooth using extra cement complete all as specified and as directed. |
| 236 | Supply only water proofing compound. |
| 237 | M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete |
| 238 | M&L for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete |
| 239 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 240 | S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed |
| 241 | S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders. |
| 242 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 243 | M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete Total carried over to BOQ Rs. 1724201.01 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 244 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 245 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 246 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed. |
| 247 | M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 248 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in footing etc complete all as specified and as directed. |
| 249 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in walls, retaining walls, basement walls, and the like , of any thickness including attached pilaster and butresses, footing etc complete all as specified and as directed. |
| 250 | Use & wate formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batte complete all as specified and as directed. |
| 251 | Use & waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and as directed. |
| 252 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 253 | M & L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 254 | Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 255 | Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 1369647.18 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VII (Summer & cooling Applinces) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 256 | Supply and Installation of Solar water heating system ,Evacuated Tube Collector based on direct transfering heat for 1500 litre per day capacity ,with electrical heating back up and all as directed. (For SM Barrack) |
| 257 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 258 | Supply and install hi wall split units capacity 2.0 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity complete all as specified. |
| 259 | Deep freezer hard top more than 320 litre and up to 400 Litre capacity having double door |
| 260 | Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 120 litres and nominal cooling capacity 60 Litres per hour . |
| 261 | Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 80 litres and nominal cooling capacity 40 Litres per hour . |
| 262 | Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134a refrigerant. Total carried over to BOQ Rs. 1478692.58 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VIII (Arboliculture) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 263 | Excavation in post holes (or similar holes) each n.exc. 0.50 Cum in self/loose soil getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 CM, watering and removing surplus soil, to a distance n.exc. 50 M. and making good surplus complete all as specified and directed. |
| 264 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 265 | S&F framed work as in door or gates of angle or other section with gusset places, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including hooks, hinges complete all as specified and directed by Engineer-in-Charge. (for tree guard) |
| 266 | S&F Welded steel wire fabric n. exc 4kg per sqm in weight, complete to wood or steel members complete all as directed. |
| 267 | Preparation of two coats of synthetic enamel paint on new steel surfaces of any description, over 10cm in width or girth,not otherwise described including preparation over a coat of red oxide Zinc chrome prime complete all as specified and directed complete all as specified and directed. Total carried over to BOQ Rs. 343184.5 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IX (FIRE FIGHTING SYSTEM) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 268 | S & F for MS ERW pipe 50 mm dia as per IS 1239 including cutting /threading/welding etc for providing connections and including all types of reqd fittings , clamps, nout & bolts etc for laid on wall/ceiling/ floor/ all as specified and directed. |
| 269 | S & F for MS ERW pipe 25 mm dia as per IS 1239 including cutting /threading/welding etc for providing connections and including all types of reqd fittings , clamps, nout & bolts etc for laid on wall/ceiling/ floor/ all as specified and directed. |
| 270 | S & F Valve,gate/ball, screwed,15 mm, brass with iron wheel head, screwed both ends for iron/MS pipe and complete all as directed. |
| 271 | S & F Valve,gate/stop, screwed,50 mm , brass with iron wheel head, screwed both ends for iron pipe and complete all as directed. |
| 272 | M & L for RRL hose reel of 20 mm dia 30 mtr long including hose box conforming to IS - 5132 complete all as specified and as directed. |
| 273 | S & F for booster(pressure) pumps / Terrace pump for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 450 LPM discharge including suitable size automatic pressure maintained pump starter complete all as specified and as directed. Rates are incl of reqd foundation wk, hur type shed for pump set made of GI sheet & angle iron, all electrical and water connection etc complete all as specified and as directed. |
| 274 | M&L for painting over steel/ iron Surfaces of any description, over 10cm in width or girth,not otherwise described incl preparation of surfaces, appying red oxide primer 01 coat, and 02 coat of synthetic enamel paint complete all as specified and as directed. Total carried over to BOQ Rs. 229782.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part X (Lightning Protection System) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 275 | Supply & fix aluminium strips 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed by Engr - in - Charge . |
| 276 | S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete as directed . |
| 277 | Supply and fix air termination rod single pointed aluminium rod length 12 mm dia & 300 mm long . |
| 278 | M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor. |
| 279 | Supply and errect vertically Galvanised, medium grade pipe 20 mm diameter complete with fittings for raising height for air termination rods all as specified and directed. |
| 280 | M & L for demolition of road/ path/ concrete in ground floors and pavings PCC 1:2:4 type B1 n exc 15 cm thickness (blow or above ground level) complete all as specified and directed. Total carried over to BOQ Rs. 278639.18 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XI (Demolition) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 281 | Taking down chowkhat with shutter not exc 1.5 sqm each complete all as directed. |
| 282 | All as per above but exc 1.5 sqm but nexc 4.0 sqm each complete all as directed. |
| 283 | Demolition of RCC of any description any any position not otherwise provided for complete all as directed. |
| 284 | Demolition of concrete ground floors and pavings n.exc 15cm thickness (below or above ground level) unreinforced complete all as directed. |
| 285 | Demolition of brickwork or stone/boulders masonry built in cement mortar or cement lime morter incl all quoins, arches, pillars etc but not excluding ashlar facing dressed stone work and precast concrete articles complete all as directed. Total carried over to BOQ Rs. 262950.9 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XII (Site Clearance) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 286 | Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil. |
| 287 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil |
| 288 | Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc |
| 289 | Removing excavated material to a distance exc 500m but n exc 1.5km, depositing where directed at a level n exc 1.5 M above the starting point. |
| 290 | M & L for Grubbing up tree trunk (exc 30 cm but n exc 100 cm) including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site |
| 291 | M & L for Grubbing up tree trunk (exc 100 cm but n exc 150 cm) including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site Total carried over to BOQ Rs. 1029525.9 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer SCHEDULE OF CREDIT Srl No. Item Description Unit Quantity Rate Amount |
| 292 | Old brick work/stone work |
| 293 | Old iron scrap+10:15 |
| 294 | Old steel shutter with frame exc 1.5 sqm but nexc 4.0 sqm including |
| 295 | Old iron scrap Total Amount 237900.0 NOTES:-1. The quantities shown in column (4) are approximate and are inserted as guide only. The actual quantities obtained from ismantling/demolition/takingdown under schedule shall be considered for credit.2. The rate given under Column (5) is firm and no variation in the rate will be allowed. The credit worthiness of the materials for which the credit is to beoffered by the contractor shall be deemed to have been ascertained by him before quoting his tender No claim onthis account shall be entertained. 3. Credit amount as indicated below shall be recovered from the contractor's dues inrelevant RAR's but in any case before removal of the demolished materials from work site. 4. The demolished materials shall be removed from site from time to time as directed by GE. However, the contractor shall be permitted to remove the demolished materials becoming his property only after the amount is deposited by the contractor. 5. No separate payment for removal of the old material including disposal of debrisshall bemade & the same shall bedeemed accounted for in the credit. Signature of Contactor DY Dir (Contracts) Date: For Accepting Office |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail