| 1 | Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including casing capping, conduit, sunken boxes etc for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L for point wiring One ligh point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 3 | All as per items srl No 2 above but for One Fan point |
| 4 | All as per items srl No 2 above but for One bell point |
| 5 | All as per items srl No 2 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 6 | All as per items srl No 2 above but for One socket out let 5 Amps 5 pin on independent board |
| 7 | All as per items srl No 2 above but for One light point controlled by two switch two way |
| 8 | All as per item No 2 here in before but with single core multistranded cable of size 4.0 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge. |
| 9 | M&L for point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty casing capping on wall with accessories like elbow, tees etc fixed on wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 10 | All as per items srl No 9 above but for One Fan point |
| 11 | All as per items srl No 9 above but for One bell point |
| 12 | All as per items srl No 9 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 13 | All as per items srl No 9 above but for One socket out let 5 Amps 5 pin on independent board |
| 14 | All as per items srl No 9 above but for One light point controlled by two switch two way |
| 15 | All as per item No 9 here in before but with FRLSH multistranded cable of size 4.0 Sqmm and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge for:- One socket outlet 15 Amp power point on Independent board. |
| 16 | M&L for modular point wiring One light point controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete with making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 17 | All as per items srl No 16 above but for One Fan point |
| 18 | All as per items srl No 16 above but for One Bell Point |
| 19 | All as per items srl No 16 above but for One socket out let 5 Amps 5 Pin on same board with other switch |
| 20 | All as per items srl No 16 above but for One socket out let 5 Amps 5 pin on independent board |
| 21 | All as per items srl No 16 above but for One light point controlled by two switch two way |
| 22 | All as per item No 16 here in before but with FRLSH multistranded cable of size 4.0 Sqmm and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge for:- One socket outlet 15 Amp power point on Independent board. |
| 23 | Material and labour for Elect bell AC 230 Volts single phase musical type complete all as specified and as directed. |
| 24 | Material and labour for bell push flush type 5 Amps complete all as specified and as directed. |
| 25 | Supply and fixing switch piano flush type 5 Amps single pole one way complete all as specified and as directed. |
| 26 | Supply and fixing switch piano flush type 5 Amps single pole two way complete all as specified and as directed. |
| 27 | Supply and fixing socket out let 2 in 1 multi pin 5 Amps flush type complete all as specified and as directed.universal |
| 28 | Supply and fixing switch piano15/16 Amps one way 240 volts complete all as specified and as directed. |
| 29 | Supply and fixing socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts complete all as specified and as directed. |
| 30 | S&F modular bell push 6 Amps single module complete all as specified and as directed. |
| 31 | Supply and fixing modular switch 6 Amps single module one way complete all as specified and as directed. |
| 32 | Supply and fixing modular switch 6 Amps single module two way complete all as specified and as directed. |
| 33 | Supply and fixing modular socket 6 Amps 5 pin double module complete all as specified and as directed. |
| 34 | S&F modular switch 16 Amps single module complete all as specified and as directed. |
| 35 | Supply and fixing modular socket 6&16 Amps 5 pin double module complete all as specified and as directed. |
| 36 | Supply and fixing modular Fan step regulator 120W, two module complete all as specified and as directed. |
| 37 | Supply and fixing on off push 25A, two module with plate complete set complete all as specified and as directed. |
| 38 | Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed |
| 39 | Supply and fixing Ceiling rose on PVC FRLSH board size 65 X 50 mm three terminal complete all as specified and as directed |
| 40 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps B curve type ,230 volts, 10 KA complete all as specified and as directed |
| 41 | Material and labour in replacement for bell push flush type 5 Amps complete all as specified and as directed. |
| 42 | Supply and fixing in replacement switch piano flush type 5 Amps single pole one way complete all as specified and as directed. |
| 43 | Supply and fixing in replacement switch piano flush type 5 Amps single pole two way complete all as specified and as directed. |
| 44 | Supply and fixing in replacement socket out let 2 in 1 multi pin 5 Amps flush type complete all as specified and as directed.universal |
| 45 | Supply and fixing switch piano15/16 Amps one way 240 volts complete all as specified and as directed. |
| 46 | Supply and fixing in replacement socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts complete all as specified and as directed. |
| 47 | S&F modular bell push 6 Amps single module complete all as specified and as directed. |
| 48 | Supply and fixing in replacement modular switch 6 Amps single module one way complete all as specified and as directed. |
| 49 | Supply and fixing in replacement modular switch 6 Amps single module two way complete all as specified and as directed. |
| 50 | Supply and fixing in replacement modular socket 6 Amps 5 pin double module complete all as specified and as directed. |
| 51 | S&F in replacement modular switch 16 Amps single module complete all as specified and as directed. |
| 52 | Supply and fixing in replacement modular socket 6&16 Amps 5 pin double module complete all as specified and as directed. |
| 53 | Supply and fixing in replacement modular Fan step regulator 120W, two module complete all as specified and as directed. |
| 54 | Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed |
| 55 | Supply and fixing in replacement Ceiling rose on PVC FRLSH board size 65 X 50 mm three terminal complete all as specified and as directed |
| 56 | Supply and fixing in replacement Lamp Holder, PVC FRLSH/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 57 | S&F of old unsv LED Tube light1 X 20 watt (04 feet), decorative ultra slim type, with integral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. |
| 58 | S&F of old unsv LED Tube light1 X 10 watt (02 feet), decorative ultra slim type, with integral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed |
| 59 | Supply and fixing LED clear white Bulb of 12 watt, 240 Volt type . |
| 60 | Taking down old unsv sub main and M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSHH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC casing capping of size 25 mm (external) with wall thickness not less than 1.8 mm, ISI marked on wall including accessories like elbow, tees, etc fixed on wall or ceiling etc. complete including taking down old existing submainwiring as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC casing caping shall be measured & paid for as one length. |
| 61 | Taking down old unsv sub main and M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC casing capping of size 25 mm (external) with wall thickness not less than 1.8 mm, ISI marked on wall including accessories like elbow, tees, etc fixed on wall or ceiling etc. complete including taking down old existing submainwiring as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC casing caping shall be measured & paid for as one length. |
| 62 | M&L for in repair/replacement sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10 Sqmm and one run of 10Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC casing capping of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked casing capping in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC casing capping shall be measured & paid for as one length. |
| 63 | Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down complete including taking down old existing as directed by Engineer-in-Charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 64 | Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing complete including taking down old existing as directed by Engineer-in-Charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 65 | S&F in replacement of Vertical Distribution Board (Concealed flush to wall), double Door, suitable for 'A' Frame FP MCCB 125 A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 4 way, 415 volts with bus bar rating 250 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete including taking down old existing as directed by Engineer-in-Charge. . |
| 66 | S&F of MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 125 Amp, 4 Pole MCCB with over load and short circuit protection, complete including taking down old existing as directed by Engineer-in-Charge. |
| 67 | Supply, fixing, connecting & testing sheet metal enclosures double door, TPN 04 way DBs,415 V, DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down complete including taking down old existing as directed by Engineer-in-Charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. |
| 68 | Supply and fixing 415V, 16 KA 'C' curve miniature circuit breaker (MCB) of triple poles and neutral current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old existing as directed by Engineer-in-Charge. |
| 69 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old existing as directed by Engineer-in-Charge. |
| 70 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old existing as directed by Engineer-in-Charge. |
| 71 | M&L for Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground,connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts,bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh,20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges,necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion.Note - The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |